검색결과 82건 처리시간 0.024초

고빈도 경피신경전기자극의 자극강도에 따른 정상 성인여성 교감신경성 반응의 변화 (Changes in Sympathetic Nervous System Responses of Healthy Adult Women with Changes in the Stimulus Intensity of High Frequency Transcutaneous Electrical Nerve Stimulation)

  • 최유림;이정우
    • The Journal of Korean Physical Therapy
    • /
    • 제22권1호
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change in sympathetic nervous system responses of healthy adult women with changes in stimulus intensity of high frequency transcutaneous electrical nerve stimulation. Methods: Twenty-four healthy subjects (women) received high frequency electrical stimulation of the forearm. The subjects were randomly assigned to one of two groups; a low intensity stimulation group (n=12) and a high intensity stimulation group (n=12). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was 20 minutes. Measured items included skin conductance, pulse rate, skin temperature, and respiration rate. Each was measured at 4 times. Results: Skin conductance and skin temperature showed significant group by time interactions, though there were no significant group and time effects. There were no significant differences according to time, group effect, and a group by time interaction in pulse and respiration rates. Conclusion: High frequency and high intensity electrical stimulation may be helpful for the improvement of sudomotor function through the activation of the sympathetic nervous system. Also, high frequency and low intensity electrical stimulation may be helpful for the reduction of sudomotor function via inhibition of the sympathetic nervous system.

방사선 구개상을 이용한 제3 후두 신경 고주파신경절개술의 시행 -증례보고- (Third Occipital Nerve Radiofrequency Neurotomy with Radiologic Open Mouth View -A case report-)

  • 박정주;정미애;심재철
    • The Korean Journal of Pain
    • /
    • 제19권2호
    • /
    • pp.244-248
    • /
    • 2006
  • Radiofrequency lesioning is a valuable tool for third occipital headache. Relative to most neural targets, a radiofrequency lesion is very small. Reliable pre-operative diagnosis of the nociceptive source is critical, as inappropriately placed lesions will not modulate pain. Knowledge of the anatomical courses of nerves and extremely precise electrode placement are required for accurate lesioning. This report describes our experience with RF lesioning in the treatment of chronic pain in two patients who suffered from third occipital headaches. In one patient, satisfactory improvement of the pain was observed after 10 months of follow up.

평판형 반도체 미세전극 어레이 제작 및 이를 이용한 무척추 동물의 말초신경다발 신호기록 (Fabrication of Planar-type Semiconductor Microelectrode Array and Its Application to Peripheral Nerve of Invertebrates)

  • 황은정;윤태환;김성준
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.145-146
    • /
    • 1998
  • A planar-type silicon microelectrode array has been fabricated and used successfully in obtaining simultaneous multichannel recordings from peripheral nerve of invertebrates. This paper demonstrates that planar-type semiconductor electrode arrays are useful for studying traveling wave properties of action potential.

  • PDF

PAN계 활성탄소섬유의 미세기공 구조가 신경작용제 유사가스(DMMP) 감응 특성에 미치는 영향 (Influence of the Micropore Structures of PAN-based Activated Carbon Fibers on Nerve Agent Simulant Gas (DMMP) Sensing Property)

  • 강다희;김민지;조한주;최예지;이영석
    • 공업화학
    • /
    • 제29권2호
    • /
    • pp.191-195
    • /
    • 2018
  • 본 실험에서는 활성탄소섬유의 미세기공구조가 신경작용제 유사가스인 dimethyl methylphosphonate (DMMP) 감응 특성에 미치는 영향을 고찰하였다. 탄소섬유에 화학적 활성화법을 이용하여 기공구조를 부여하였고, 이를 이용하여 가스센서용 전극을 제조하였다. N형 반도체인 polyacrylonitrile (PAN)계 활성탄소섬유 기반 전극은 환원성 가스인 DMMP로부터 전자를 받아 정공의 밀도 감소로 인하여 전기저항이 감소하게 되었다. DMMP 가스센서의 민감도는 미세기공 부피가 증가함에 따라 1.7%에서 5.1%까지 증가하였다. 이는 분자 크기가 0.57 nm인 DMMP를 흡착하기에 적합한 미세기공이 형성됨에 따라, DMMP와 활성탄소섬유간의 전자 이동이 용이해졌기 때문이라 사료된다. 결론적으로, 높은 감도의 DMMP 가스센서를 제조하기 위해서는 적절한 기공구조 조절이 중요한 역할을 한다고 판단된다.

가토반규관신경자극(家兎半規管神經刺戟)에 대(對)한 외안근(外眼筋)의 반응(反應)에 관(關)하여 (Reflex Responses of the Extraocular Muscles upon Ampullary Nerve Stimulation in Rabbits)

  • 김사원
    • The Korean Journal of Physiology
    • /
    • 제4권1호
    • /
    • pp.59-67
    • /
    • 1970
  • In recent observations on vestibular eye movements in mammals, reported by several different workers, it was indicated that the pattern of reflex eye movement from semicircular canal nerve stimulation in rabbits was different from that observed in the other species such as cats and dogs. Observing the different anatomical features of the extraocular muscles of rabbits, Kim ascribed the different pattern of eye movement of rabbits to the functional difference of inferior and superior oblique muscles from those of other species. Present experiment was carried out to elucidate a physiological mechanism underlying in such particular pattern of reflex eye movement in rabbits. An individual canal nerve was selectively stimulated, under a dissecting microscope, by a fine electrode induced into an ampulla through a hole provided on the wall of corresponding osseous canal, and responses of the extraocular muscles were checked by recording the isotonic changes of muscle length. Following results were obtained. 1. Direct stimulation of the superior or inferior oblique muscles Produced upward or downward movement of the eye turning toward medial side respectively. 2. Stimulation of the unilateral canal nerve Produced a marked contraction of a main contracting ocular muscle and simultaneous relaxation of an antagonistic muscle in both eyes. Less potent contraction of an additional ocular muscle was observed and it appeared to augment the function of the main contracting muscle in the ipsilateral eye. 3. Stimulation of superior semicircular canal nerve caused a primary contraction of superior rectus, synergic contraction of superior oblique and relaxation of inferior rectus in ipsilateral eye. Contraction of inferior oblique and relaxation of superior oblique were observed in the contralateral eye. 4. Stimulation of lateral semicircular canal nerve produced a primary contraction of medial rectus, synergic contraction of superior oblique and relaxation of lateral rectus in the ipsilateral eye. Contraction of lateral rectus and relaxation of medial rectus were observed in the contralateral eye. 5. Stimulation of inferior semicircular canal nerve produced a primary contraction of superior oblique, synergic contraction of superior rectus and relaxation of inferior oblique in the ipsilateral eye. Contraction of. inferior rectus and relaxation of superior rectus were observed in the contralateral eye. 6. Upon stimulation of individual canal nerve, the pattern of eye movement in rabbits is different from those of cats, however, the responses of the extraocular muscles appear to be similar in two species. Therefore, it is concluded that the different Pattern of eye movement in both species are not due to the possible difference of vestibule-ocular reflex pathways but to the functional difference of superior and inferior oblique muslces.

  • PDF

New insight into the mandibular nerve at the foramen ovale level for percutaneous radiofrequency thermocoagulation

  • Peng-Bo Zhu;Yeon-Dong Kim;Ha Yeong Jeong;Miyoung Yang;Hyung-Sun Won
    • The Korean Journal of Pain
    • /
    • 제36권4호
    • /
    • pp.465-472
    • /
    • 2023
  • Background: Percutaneous radiofrequency thermocoagulation (RFTC) has been widely utilized in the management of trigeminal neuralgia. Despite using image guidance, accurate needle positioning into the target area still remains a critical element for achieving a successful outcome. This study was performed to precisely clarify the anatomical information required to ensure that the electrode tip is placed on the sensory component of the mandibular nerve (MN) at the foramen ovale (FO) level. Methods: The study used 50 hemi-half heads from 26 South Korean adult cadavers. Results: The cross-sectioned anterior and posterior divisions of the MN at the FO level could be distinguished based on an irregular boundary and color difference. The anterior division was clearly brighter than the posterior one. The anterior division of the MN at the FO level was located at the whole anterior (38.0%), anteromedial (6.0%), anterior center (8.0%), and anterolateral (22.0%) parts. The posterior division was often located at the whole posterior or posterolateral parts of the MN at the FO level. The anterior divisions covered the whole MN except for the medial half of the posterolateral part in the overwrapped images of the cross-sectional areas of the MN at the FO level. The cross-sectional areas of the anterior divisions were similar in males and females, whereas those of the posterior divisions were significantly larger in males (P = 0.004). Conclusions: The obtained anatomical information is expected to help physicians reduce unwanted side effects after percutaneous RFTC within the FO for the MN.

Comparison of Temporal Bone Parameters before Cochlear Implantation in Patients with and without Facial Nerve Stimulation

  • Kasetty, Venkatkrish Manohar;Zimmerman, Zachary;King, Sarah;Seyyedi, Mohammad
    • Journal of Audiology & Otology
    • /
    • 제23권4호
    • /
    • pp.193-196
    • /
    • 2019
  • Background and Objectives: Facial nerve stimulation (FNS) is a complication of cochlear implantation (CI). This study compared the thickness and density of the bone separating the upper basal turn of the cochlea (UBTC) and the labyrinthine segment of the facial nerve (LSFN) on preoperative computed tomography (CT) in patients with and without FNS after CI. Subjects and Methods: Adult patients who underwent CI from January 2011 to February 2017 with preoperative CT at a tertiary referral hospital were considered for this retrospective case-control study. Patients were divided into two groups: with FNS (n=4) and without FNS (n=53). The density and thickness of the bone between the LSFN and UBTC were measured on preoperative CT. Charts were reviewed for other parameters. Results: A statistically significant difference was seen in the thickness (p=0.007) but not in the density (p=0.125) of the bone between the UBTC and LSFN. Four patients had FNS at the mid-range electrode arrays, and one of them additionally had FNS at the basal arrays. Conclusions: Decreased thickness of the bone between the UBTC and LSFN can explain postoperative FNS, confirming the histologic and radiologic findings in previous studies, which indicated that the thickness of the temporal bone between the LSFN and UBTC is less in patients who experience FNS. While the density in this region was also less, it was not statistically significant.

Comparison of Temporal Bone Parameters before Cochlear Implantation in Patients with and without Facial Nerve Stimulation

  • Kasetty, Venkatkrish Manohar;Zimmerman, Zachary;King, Sarah;Seyyedi, Mohammad
    • 대한청각학회지
    • /
    • 제23권4호
    • /
    • pp.193-196
    • /
    • 2019
  • Background and Objectives: Facial nerve stimulation (FNS) is a complication of cochlear implantation (CI). This study compared the thickness and density of the bone separating the upper basal turn of the cochlea (UBTC) and the labyrinthine segment of the facial nerve (LSFN) on preoperative computed tomography (CT) in patients with and without FNS after CI. Subjects and Methods: Adult patients who underwent CI from January 2011 to February 2017 with preoperative CT at a tertiary referral hospital were considered for this retrospective case-control study. Patients were divided into two groups: with FNS (n=4) and without FNS (n=53). The density and thickness of the bone between the LSFN and UBTC were measured on preoperative CT. Charts were reviewed for other parameters. Results: A statistically significant difference was seen in the thickness (p=0.007) but not in the density (p=0.125) of the bone between the UBTC and LSFN. Four patients had FNS at the mid-range electrode arrays, and one of them additionally had FNS at the basal arrays. Conclusions: Decreased thickness of the bone between the UBTC and LSFN can explain postoperative FNS, confirming the histologic and radiologic findings in previous studies, which indicated that the thickness of the temporal bone between the LSFN and UBTC is less in patients who experience FNS. While the density in this region was also less, it was not statistically significant.

전기자극 수준이 정상 성인의 자율신경계에 미치는 영향 (The Effect of Electrical Stimulation Level on Autonomic Nerve System in Normal Adults)

  • 진희경;조성현
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2029-2037
    • /
    • 2015
  • 본 연구의 목적은 척수분절레벨에 적용한 간섭전류의 자극수준에 따른 정상성인의 자율신경계에 미치는 영향을 알아보고자 하였다. 간섭전류는 T1-T4 분절에 접착식 패드전극을 2극 배치 후 20분간 전기자극하여, 전기자극 전과 후, 30분 후의 변화를 확인하였다. 연구대상은 광주시에 소재한 N대학교에 다니는 건강한 성인남녀 45명을 대상으로 감각자극수준은 100 bps, 10~12 mA, 운동자극수준은 5 bps, 45~50 mA, 유해자극수준은 100 bps, 80~90 mA으로 각각 15명씩 무작위 배치하여 연구를 수행하였으며 연구 결과는 다음과 같다. 각 집단의 교감신경활성도의 변화는 시간과 집단 간의 상호작용에 유의한 차이가 없었으나, 시간에 따라 유의한 변화를 보여주었다(p<.05). 사후 분석결과 전기자극 직후와 전기자극 후 30분에서 유의한 차이를 보여주었다(p<.05). 각 집단의 부교감신경활성도의 변화는 시간과 집단 간의 상호작용에 유의한 차이가 없었으나, 시간에 따라 유의한 변화를 보여주었다(p<.05). 사후 분석결과 전기자극 직후와 전기자극 후 30분에서 유의한 차이를 보여주었다(p<.05). 이상의 결과로 전기자극 수준은 특정목적과 상황에 따라 다양하게 적용되어야 할 것으로 생각된다.

슬관절 자극이 횡격신경 및 흡식중추신경에 미치는 영향 (Effect of Knee Joint Stimulation on the Activity of Phrenic Nerve and Inspiratory Nuron in the Cat)

  • 조동일;한희철;남숙현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권6호
    • /
    • pp.683-693
    • /
    • 1993
  • 연구배경 : 생체의 운동은 움직임 자체를 수행하기 위한 근육, 관절 및 이를 관장하는 신경계와 운동중 적절한 산소를 공급하기 위한 심혈관계 및 호흡계의 조절이 동반되는 매우 복잡한 기전에 의하여 유지되고 있다. 이들의 상호관련성을 밝히기 위하여 많은 연구들이 진행중이나 특히 관절과 호흡중추의 연계성에 대하여는 아직도 연구가 미진한 편이다. 이에 본 연구는 관절의 정상적인 움직임이 호흡계에 어떠한 영향을 미치는지를 규명하고자 $\alpha$-chloralose로 마취한 고양이의 분당 호흡수, 횡격신경과 흡식신경섬유의 변화를 관찰하였다. 방법 : 26마리의 성숙한 숫고양이에서 슬관절 자극중 횡격신경 및 흡식중추신경의 활동성을 기록하기 위하여 쌍극백금전극과 탄소섬유전극을 이용하여 세포외에서 기록하였다. 슬관절을 자극하기 위하여 슬관절의 굴곡-신전운동, 슬관절 동맥을 통한 화학적인 자극 및 슬관절 신경의 전기적인 자극법 등을 사용하였다. 결과 : 슬관절의 정상 운동각도내에서 120 Hz.의 빠른 운동을 1분간 시킨 경우에는 분당호흡수와 분당호흡신경활동이 유의하게 증가하였으며 3분간 운동을 시킨 경우에는 호흡수, 일회호흡신경활동 및 분당호흡신경활동이 모두 유의하게 증가하였다. 그러나 60Hz.의 운동에 대하여는 전체적인 호흡활동에 뚜렸한 변화가 없었다. 과격한 운동중에 형성되는 젖산의 혈중농도와 같은 농도의 젖산을 슬관절내에 주입한 결과 주입후 30초 동안에 호흡수 이외의 일회호흡신경활동과 분당 호흡신경 활동이 유의한 증가를 보였다. 또한 potassium chloride에 대하여는 젖산의 경우와 유사한 반응을 보였으나 반응기간이 짧았다. 구심성 신경중 I, II군만을 선택적으로 흥분시킬 수 있는 강도인 1V로 슬관적 신경을 자극한 경우 자극기간에 한하여 호흡수를 제외한 일회호흡신경활동 및 분당호흡신경활동이 유의한 증가를 보였다. 또한 구심성 신경을 모두 흥분시키는 강도인 20V 자극에 대하여는 호흡계의 전체적인 항진효과가 있었으며 1V 자극에 비하여 매우 큰 반응을 나타내었다. 흡식중추의 신경세포에서 기록한 결과 횡격신경에서 나타난 반응과 유사한 결과를 얻었다. 결론 : 슬관절 구심성 신경중 제 I, II 군 신경의 흥분에 의하여 호흡중추는 직접적으로 활성화될 수 있으며 이러한 효과는 운동중의 슬관절로부터 중추로 유입되는 정보의 양에 비례하여 증가하는 것으로 생각된다. 따라서 이러한 사실은 슬관절의 정상적인 움직임에 의해서도 생체의 호흡기능이 항진될 수 있다는 것을 시사하고 있다.

  • PDF