• Title/Summary/Keyword: negative stretching

Search Result 23, Processing Time 0.031 seconds

Electrostatic Interaction Between Oligopeptides and Phosphate Residues by Determination of Absolute Raman Intensities

  • Kye-Taek Lim
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.286-289
    • /
    • 1991
  • The changed isotropic absolute Raman intensities of the phosphate residue in the complexes of positive charge oligopeptides, lys-lys, arg-arg, lys-aromat-lys, negative charge diethyl phosphoric acid (DEP) and polyriboadenylic acid{poly(rA)} were reported and discussed. Our measurements showed that the absolute intensities of phosphate stretch vibration in complexes were different according to the reaction partners. Due to the partial electrical charge and molecular structure of oligopeptides for the complex formation lysine can interact more strongly than arginine when the reaction partners have short chain and no steric hindrance. Owing to these reasons the intensity of phosphate stretching vibration is very sensitive according to the circumstance of reaction. From our results we could suggest that we can discriminate any one of the the lysine and arginine in the complicated biological molecule during interaction between nucleotides and proteins. The activity of reaction of two basical oligopeptides is not quite similar for complex formation in aqueous solution. The activity of dipeptides depends upon the structure of molecule and environment for complex formation. Aromatic ring contributes to electrostatic interaction in complexes. The amount of the absolute intensity for pure stacking interaction is smaller than electrostatic interaction in macromolecular complexes.

Fabrication and Assessment of Flexible Nanostructured Film for Antibacterial Properties (항균 특성을 위한 나노구조 유연 필름의 제작 및 평가)

  • Park, Hyun-Ha
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.105-109
    • /
    • 2022
  • In the field of medical and marine industries, antibacterial surfaces have been emerged as one of the most important issues. Recently, many researchers have been studying antibacterial surfaces to kill bacteria or prevent the adhesion of bacteria. In their researches, various materials and structures are suggested to inhibit the adhesion of bacteria or kill the attached bacteria. However, chemical materials such as antibiotics or metal could be toxic. Moreover, frequent use of antibiotics causes super bacteria having resistance to antibiotics. In this study, nano-pillar structured surface was fabricated using polyurethane acrylate (PUA) and the mechanically induced antibacterial function was confirmed based on the fabricated nanostructures. Nanostructures can damage the bacterial membrane of Gram-negative bacteria through stretching of bacterial membrane via interaction with the nanostructures and the bacterial membrane. Consequently, the proposed transparent, flexible and nanostructured PUA films can be one of promising candidates for antifouling and antibacterial surfaces which can be applied in various industries.

Robustness of Face Recognition to Variations of Illumination on Mobile Devices Based on SVM

  • Nam, Gi-Pyo;Kang, Byung-Jun;Park, Kang-Ryoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.1
    • /
    • pp.25-44
    • /
    • 2010
  • With the increasing popularity of mobile devices, it has become necessary to protect private information and content in these devices. Face recognition has been favored over conventional passwords or security keys, because it can be easily implemented using a built-in camera, while providing user convenience. However, because mobile devices can be used both indoors and outdoors, there can be many illumination changes, which can reduce the accuracy of face recognition. Therefore, we propose a new face recognition method on a mobile device robust to illumination variations. This research makes the following four original contributions. First, we compared the performance of face recognition with illumination variations on mobile devices for several illumination normalization procedures suitable for mobile devices with low processing power. These include the Retinex filter, histogram equalization and histogram stretching. Second, we compared the performance for global and local methods of face recognition such as PCA (Principal Component Analysis), LNMF (Local Non-negative Matrix Factorization) and LBP (Local Binary Pattern) using an integer-based kernel suitable for mobile devices having low processing power. Third, the characteristics of each method according to the illumination va iations are analyzed. Fourth, we use two matching scores for several methods of illumination normalization, Retinex and histogram stretching, which show the best and $2^{nd}$ best performances, respectively. These are used as the inputs of an SVM (Support Vector Machine) classifier, which can increase the accuracy of face recognition. Experimental results with two databases (data collected by a mobile device and the AR database) showed that the accuracy of face recognition achieved by the proposed method was superior to that of other methods.

Torticollis Management Using the Customized Soft Neck Collar in CATCH 22 Syndrome Combined with Klippel-Feil Anomaly: A Case Report

  • Moon, Myung-Hoon;Kim, Soo-Yeon
    • Journal of Interdisciplinary Genomics
    • /
    • v.1 no.2
    • /
    • pp.19-22
    • /
    • 2019
  • CATCH 22 syndrome is rare genetic disease that has various manifestations. Cervical vertebral anomaly, such as Klippel-Feil anomaly, is frequently observed in the patients with CATCH22 syndrome. We present the case of an 11-year-old female patient with CATCH22 syndrome and Klippel-Feil anomaly who had been treated torticollis using the customized soft neck collar. During the patient's first visit to our clinic, she presented with low ear set, skull deformity, intellectual disability, and tilting of the head to the left by approximately 25 degrees. Imaging studies revealed multisegmental fusion and C3 hemivertebrae of the cervical spine and left thoracic scoliosis at T4 with 50 degrees of Cobb's angle. We instructed passive stretching and applied the customized soft neck collar we invented. The ipsilateral aspect of the neck collar is designed to provide vertical support between the clavicle and mandibular angle and is adjustable in height. The Velcro was attached to the neck collar at the point of contact with the ipsilesional mandibular angle, which provides negative sensory feedback, inducing her to tilt neck to the contralesional side. We applied the neck collar for 2 hours a day. After 1 year of treatment, her neck inclination angle improved from 25 to 10 degrees. Providing negative sensory feedback using the customized soft neck collar can be one of the treatment options of postural management in patients with torticollis in cases of CATCH 22 syndrome combined with Klippel-Feil anomaly.

Injection of a Denser Fluid into a Rotating Cylindrical Container Filled with Homogeneous Lighter Fluid (균질의 회전유체에 고밀도유체 주입실험)

  • 나정열;황병준
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.355-364
    • /
    • 1995
  • A heavy fluid is injected to a rotating cylindrical container of flat or inclined bottom filled with homogeneous lighter fluid. Continuous flow-in and spreading patterns over the bottom of the container are observed and at the same time upper-layer motions induced by the movement of the heavy fluid are traced by thymol blue solution. Regardless of bottom geometry, the injected denser fluid is deflected toward "western wall" and continuous its path along the boundary with radial spreading which occurs in the bottom boundary layer to make a quite asymmetric flow. When the bottom contains a slope(${\beta}$-plane), increased pressure gradient causes the fluid move faster to produce a stronger Coriolis force. This makes the width of the flow narrower than that of f-plane. But, when the denser flow reaches the southern part of the container, a local-depth of denser fluid increases (much greater than the Ekman-layer depth) such that the spreading velocity along the wall is reduced and the interfacial slope increases to make the upper-layer adjust geographically to have oppositely directed upper-layer motion along the interfacial boundary. The role of the denser fluid in terms of vorticity generation in the upper-layer is such that it produces local topographic effect over the western half of the container and also induces vortex-tube stretching which is especially dominant in the f-plane.

  • PDF

Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson's Disease: A Prospective Preliminary Study

  • Lu Yin;Lijuan Du;Yuanzi Li;Yang Xiao;Shiquan Zhang;Huizi Ma;Wen He
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1841-1849
    • /
    • 2021
  • Objective: To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson's disease (PD). Materials and Methods: SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD): 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD: 59.3 ± 6.4 years) during passive ankle rotation. A Young's modulus-ankle angle curve was constructed. The GM slack angle and baseline Young's modulus (E0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. Results: The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of -29.13° ± 3.79° and -25.65° ± 3.39°, respectively, vs. -21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = -0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. Conclusion: The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.

Conformations, Chemical Reactivities and Spectroscopic Characteristics of Some Di-substituted Ketenes: An ab initio Study

  • Gupta, V.P.;Sharma, Archna;Agrawal, S.G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1297-1304
    • /
    • 2006
  • A systematic study of the structure, energetics and spectral characteristics of substituted aminoketenes $R(NH_2)$C=C=O (R = H, $CH_3$, $NH_2$, OH, $OCH_3$, CH=$CH_2$, C$\equiv$CH, CN, CHO, NO, $NO_2$) which are highly reactive and transient intermediates in synthesis has been conducted by ab initio calculations at the MP2/6- 31G*//MP2/6-31G* level. Twenty four stable isomers of the eleven substituted aminoketenes having dihedral angles $\phi NH_2\sim120{^{\circ}}$ and $60^{\circ}$ have been identified and their optimized geometries and energies obtained. Electrostatic and steric effects on the molecular geometries have been analyzed. While the $\pi$-acceptor groups lead to planar conformations, the electron-donor groups give rise to non-planar conformations. Isodesmic substituent stabilization energies relative to alkenes have been calculated and correlation with group electronegativities established. Role of induction effect by the substituent groups and resonance effects in charge distribution in the molecules has been analyzed. An analysis of the asymmetric stretching frequencies and intensities of the C=C=O group shows that affect of non-$\pi$ acceptor substituents on the frequency is determined by the field effect (F) and resonance effect (R) parameters, the calculated intensities I (km/mol.) are correlated to group electronegativities $x$ of the substituents by the relationship I = 640.2–100.1 $x$ (r = 0.92). The $\pi$-acceptor substituents increase the intensity which may be explained in terms of their delocalizing effect on the negative charge at the $C_{\beta}$ atom.

A STUDY ON THE BIOMECHANICAL PROPERTIES OF ORTHODONTIC RUBBER ELASTIC MATERIALS (교정용 고무탄성재료의 생역학적 성질에 관한 연구)

  • Song, Hyun-Sup;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.563-580
    • /
    • 1991
  • The purpose of this study was to investigate and compare the biomechanical properties of orthodontic rubber elastic materials. Latex bands, nylon-covered elastic threads and polyurethane-based elastic modules, delivering $205{\pm}10$ grams force at 30mm stretching state were selected and stored separately in 3 environments-air ($22{\pm}3^{\circ}C$), distilled water ($37{\pm}1^{\circ}C$), or natural saliva ($37{\pm}1^{\circ}C$). And, the amount of remaining force and permanent elongation of each sample were measured on Instron at interval of 1 hour, 6 hours, 12 hours, 24 hours, 1 week, and 2 weeks. So the data derived were analyzed statistically. The results were as follows: 1. Force decay and permanent elongation of all materials increased with time lapsed; elastic module, latex band and nylon-covered elastic thread in that order of the amount of force decay; elastic module, elastic thread, latex band in that order of the amount of permanent elongation. 2. Among environmental conditions, force decay and permanent elongation in natural saliva, most increased, and those in air, least increased. 3. There was a negative correlation between force decay and permanent elongation. 4. Force decay and permanent elongation were most affected by the material itself, time and environments in that order. 5. After 24 hours in saliva, the percentage of remaining force in elastic module was 51.9% (107.37grams); in latex band, 83.2%(172.62grams); in elastic thread, 85.0%(179.25grams). After 2 weeks in saliva, the percentage of remaining force in elastic module was 42.9%(88.75grams); in latex band, 74.5%(154.50grams); in elastic thread, 77.6%(163.75grams).

  • PDF

A Study on the Shrinkage of Silk Fabric by $Ca(NO_3){_2}$ Solution

  • Choi, Se-Min;Shin, Yu-Ju;Kim, Jong-Jun;Jeon, Dong-Won
    • Journal of Fashion Business
    • /
    • v.13 no.3
    • /
    • pp.136-148
    • /
    • 2009
  • The phenomenon of the shrinkage of silk fibers induced by inorganic salts including LiBr, $Ca(NO_3){_2}$, and $CaCl_2$, has been studied up to the present as one of the finishing methods of silk. It is expected that the shrinkage phenomenon may greatly contribute to the realization of the high sensibility of silk fibers. Especially the shrinkage enables the expression of three-dimensional appearance of silk fabrics along with the improvements in dimensional stability, resilience in stretching, and comfort. Numerous theoretical studies on the contraction phenomenon by $Ca(NO_3){_2}$ have been conducted so far. These studies have focused mostly on the silk fibers. It is difficult to find studies on silk fabrics. The negative aspects of the finishing are such as strength drop, yellowish discoloration, and fiber damage. These should also be considered as well as the positive aspects. In this study, the phenomenon of salt shrinkage is diversely reviewed by applying $Ca(NO_3){_2}$ solution for the silk fabrics as objects. The changes in the air permeability, thickness, and color were investigated with focus on the shrinkage of the silk fabrics according to the changes in treatment conditions. Some findings from this study are as follows: Within short period of time at the initiation of salt shrinkage, the salt shrinkage proceeds effectively. In the case of concentration of 47.4%, or 46.3% of $Ca(NO_3){_2}$ solution, appropriate treatment time seems to be 20seconds, or $2{\sim}8$minutes, respectively. Excessive shrinkage is obtained when lower liquor ratio is adopted. As a result, the condition is acting extremely disadvantageously against the thickness and yellow discoloration aspects.

Effects of Dental Hygienist's Musculoskeletal Pain Resolution and Self-Efficacy on Musculoskeletal Disorders (치과위생사의 근골격계 통증 해결 방법과 자기효능감이 근골격계 질환에 미치는 영향)

  • Moon, Ae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.329-338
    • /
    • 2018
  • This study was conducted to examine musculoskeletal disorder and analyze the effects of musculoskeletal pain control and self-efficacy on musculoskeletal disorders in dental hygienists. Material and Methods; 483 dental hygienists residing in Gwangju were collected by the convenience sampling method and the self-administered questionnaire survey was conducted. Frequency analysis, crosstab analysis, t-test, and multiple logistic regression analysis were used for analysis. Results: the prevalence of musculoskeletal pain among subjects was 83.9% for the prior year, with 29.8% of patients being afflicted by musculoskeletal disorders. The factors influencing musculoskeletal disorders were musculoskeletal pain resolution. For pain resolution, the odds ratio of musculoskeletal disorders of the group who answered treatment in a hospital, an Oriental medicine clinic, or a pharmacy was 0.22 (95% confidence interval, 0.14-0.34) compared with the group who answered sick leave or task change, suggesting a negative relationship. These findings indicate that people with musculoskeletal disorders were not treated in the hospital, Oriental medicine clinic, or pharmacy. Therefore, it is necessary to improve medical management (oriental medicine, intravenous injection or medication, heat therapy or cryotherapy, steroid treatment, counseling, endovascular treatment using spinal cord stimulation, physical therapy, stretching, rehabilitation, and manual therapy) and job environment and to make a good approach to the prevention of musculoskeletal disorders to control dental hygienists' musculoskeletal pain.