• Title/Summary/Keyword: needle technique

Search Result 299, Processing Time 0.074 seconds

부침 이해를 위한 문헌 비교: 경근, 근막동통이론, 완과침 그리고 부침 (Comparative Literature Review of Floating Acupuncture: Compared to Meridian Muscle, Myofascial Pain Syndrome and Wrist-Ankle Acupuncture)

  • 김청수;남연경;;양승범;김재효;권오상
    • Korean Journal of Acupuncture
    • /
    • 제40권2호
    • /
    • pp.33-43
    • /
    • 2023
  • Objectives : Floating acupuncture (FA) is a kind of newly developed acupuncture technique that contains its own apparatus. The technique has unique points that the body of the acupuncture needle stays intradermal space and manipulation is performed by shaking the needle horizontally; after manipulation, part of the needle remained in the intradermal space for 2~3 days. FA is not a common acupuncture methodology while various clinical study claims its efficacy on musculoskeletal disorders. In this study, the authors aimed to enhance the use of FA by comparing related theories. Methods : The authors reviewed classics, books, and articles related to FA, Meridian Muscle (MM), Myofascial Pain Syndrome (MPS), and Wrist-Ankle Acupuncture (WAA), and compared its characteristics by related theory, related symptoms, apparatus, and performing procedures. Results : FA was related and had various common parts with MM, MPS, and WAA, however, there were unique parts in the manipulation, apparatus, and stimulation location. FA is based on MM and MPS which pointing 'ashi points' or 'trigger points' as a treating target while FA does not stimulate the points directly. FA also targets subcutaneous space by inserting the needle horizontally as WAA does, while FA remains the needle handle part in the subcutaneous area for 2~3 days for more stimulation. Conclusions : FA has a unique manipulation procedure and potential benefit for musculoskeletal disorders despite the crude theological base written by Fu himself. Thus, developing a new explanation and patient-friendly methodology/apparatus is required for further down-to-earth studies.

Urea-SCR용 스월 인젝터의 니들 리프트 형상에 따른 유동특성에 대한 연구 (Study on the Flow Characteristics of Urea-SCR Swirl Injector according to the Needle Lift Profile)

  • 곽은조;박성영
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.650-655
    • /
    • 2016
  • 본 논문에서는 요소수를 적용하는 SCR 인젝터의 내부유동에 대한 전산 유동해석을 수행하였다. 유동해석에 적용된 인젝터는 경사진 노즐과 스월디스크를 갖는 스월타입의 단홀 인젝터이다. 인젝터 니들의 최대 리프트 및 열림 속도를 인젝터의 설계 변수로 선정하였다. 비정상 상태로 작동하는 노즐 내부의 유동 특성을 해석하기 위하여, 움직이는 물체에 적용이 가능한 Moving Grid 기법을 적용하여 정밀한 인젝터 니들의 움직임을 모사하였다. 유동해석 결과, 인젝터 니들의 속도가 증가할수록 출구를 통한 요소수 유량은 감소하는 것으로 나타났다. 이는 인젝터 니들의 속도가 빨라질수록, 인젝터 니들 하부의 빈 공간을 채우려는 유량이 증가하고, 이러한 요소수 유량의 증가가 노즐 출구로 방출되는 유량의 감소를 유발하게 된다. 요소수 유동이 인젝터 노즐에서 출구 쪽으로 진행할수록, 스월 유동은 감소하였다. 이는 유동과 노즐 벽면과의 마찰에 기인한 것으로 사료된다. 또한, 최대 리프트 유지기간에서, 니들 리프트가 높을수록 스월 계수와 평균 스월 계수가 증가하는 경향을 보였다. 본 연구의 결과는 관련된 Urea-SCR 인젝터의 기본 설계 자료로 활용될 수 있을 것이다.

마이크로 EDM공정을 이용한 마이크로 바늘의 제조 (Manufacturing of Micro-needle Using Micro-EDM Process)

  • 리춘미;권원태
    • 한국생산제조학회지
    • /
    • 제26권3호
    • /
    • pp.285-291
    • /
    • 2017
  • Micro-needles are used as transferring devices for sampling of tiny constitute substances from biological bodies. Typically, nickel is used as a coating to improve the rigidity of micro-needles. This study introduces the methodology to manufacture a WC needle with very high hardness and toughness. Micro-EDM technology was used to manufacture micro-needles with holes $130{\mu}m$ in diameter and $2300{\mu}m$ in length. A micro-needle was aligned to the micro-EDM electrode using a custom two degree-of-freedom alignment system. A three-step manufacturing technique was developed to drill a micro-hole using a WC electrode. In the first process, an electrode $105{\mu}m$ in diameter was used to make a hole. Electrodes of 90 and $105{\mu}m$ diameters were used in the second and third process, respectively. Consequently, a WC micro-needle with an inner hole of $135{\mu}m$ diameter, length of $2300{\mu}m$, and outer diameter of $300{\mu}m$ was developed.

측두하악관절 추나요법과 청궁혈 온침으로 호전된 만성 이명 환자 1례 보고 (The Effect of Temporomandibular Joint Chuna Manipulation and Warm Needle Acupuncture at SI19 on Chronic Tinnitus; a Case Report)

  • 황의형;설재욱;신병철;신미숙;조현우
    • 한방재활의학과학회지
    • /
    • 제21권3호
    • /
    • pp.71-78
    • /
    • 2011
  • Objectives : The purpose of this study is to report the combination effect of Chuna manipulation and warm needle acupuncture for a case of obstinate chronic tinnitus. Methods : We applied Danmuji Anchu Tracton technique, lateral pterygoid Chuna and warm needle acupuncture at SI19 once a day for 2 weeks. Visual analogue scale(VAS) was used for the intensity of tinnitus and tinnitus handicap inventory(THI) was evaluated. Results : VAS was improved from 6 to 2 in right ear, 4 to 1 in left ear after the treatment. THI was also improved from 54 to 34 after the treatmemt. Conclusions : The combined therapy of Chuna manipulation and warm needle acupuncture can be used for chronic tinnitus.

Study on the Characteristics of PP/PET Blended Nonwovens Produced by Needle-punched Methods

  • Gwon O-Hyeok;Lee Rae-Yeon;Ju Chang-Hwan
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1998년도 가을 학술발표회논문집
    • /
    • pp.402-405
    • /
    • 1998
  • Among the production technologies of nonwoven fabrics, a needle punching technique has one of the long history aid holds still important place. At the present time, it is used not only for scrimming with woven or knitted fabrics and other nonwoven fabrics, but also for applying the special fibers blending nonwovens at the web forming process in ender to manufacture economical and high value added-Products such as home furnishing industrial and technical purpose. (omitted)

  • PDF

연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가 (Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images)

  • 이소희;김종운;이수열;류정원;최동혁;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권5호
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

GDI 인젝터의 동적 거동과 분사 특성에 대한 모델링 (Modeling Dynamic Behavior and Injection Characteristic of a GDI Injector)

  • 이계은;김나영;조영준;이동률;박성욱
    • 한국분무공학회지
    • /
    • 제22권4호
    • /
    • pp.210-217
    • /
    • 2017
  • A gasoline direct injection engine has an intake air temperature can be lowered by the fuel vaporization in the combustion chamber increase the volume efficiency is high compression ratio. Therefore, study for injection rate and characteristics which influence mixture formation in combustion chamber is important. Movement of the injector needle has a direct effect on the injection of the fuel, such as formation of cavitation, the fuel injection rate, etc. Therefore, recent studies on the dynamic characteristics of the injector considering the movement of the needle have been reported, but it takes a lot of time and cost to experimentally confirm the movement of the needle inside the injector. In this study, AMESim, a commercial 1-D code, and Star-CCM+, a 3-D CFD code, were used to predict the dynamic performance of the injector with needle motion. In order to predict the movement of the needle under the high pressure, the result of the surface pressure distribution according to the movement of the needle was derived by using the morphing technique of flow analysis. In addition, we predicted the injection rate of the injector considering the movement of the needle in conjunction with the 1-D code. The injection rate of the injector was measured by the BOSCH's method and the results were similar to those of the simulation results. This method can predict the injection rate and injection characteristics and this result is expected to be used to predict the performance of gasoline direct injection engines with low cost and time in the future.

Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention

  • Lee, Jae-Heon;Jeon, Gye-Rok;Ro, Jung-Hoon;Byoen, Gyeong-Jo;Kim, Tae-Kyun;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • 제25권2호
    • /
    • pp.81-88
    • /
    • 2012
  • Background: In discography performed during percutaneous endoscopic lumbar discectomy (PELD) via the posterolateral approach, it is difficult to create a fluoroscopic tunnel view because a long needle is required for discography and the guide-wire used for consecutive PELD interrupts rotation of fluoroscope. A stereotactic system was designed to facilitate the determination of the needle entry point, and the feasibility of this system was evaluated during interventional spine procedures. Methods: A newly designed stereotactic guidance system underwent a field test application for PELD. Sixty patients who underwent single-level PELD at L4-L5 were randomly divided into conventional or stereotactic groups. PELD was performed via the posterolateral approach using the entry point on the skin determined by premeasured distance from the midline and angles according to preoperative magnetic resonance imaging (MRI) findings. Needle entry accuracy provided by the two groups was determined by comparing the distance and angle measured by postoperative computed tomography with those measured by preoperative MRI. The duration and radiation exposure for determining the entry point were measured in the groups. Results: The new stereotactic guidance system and the conventional method provided similarly accurate entry points for discography and consecutive PELD. However, the new stereotactic guidance system lowered the duration and radiation exposure for determining the entry point. Conclusions: The new stereotactic guidance system under fluoroscopy provided a reliable needle entry point for discography and consecutive PELD. Furthermore, it reduced the duration and radiation exposure associated with determining needle entry.

Development of spherical crystallization technique and its application to pharmaceutical systems

  • Kawashima, Yoshiaki
    • Archives of Pharmacal Research
    • /
    • 제7권2호
    • /
    • pp.145-151
    • /
    • 1984
  • A novel agglomeration technique, termed "Spherical Crystallization Process", which can transform directly the fine crystals produced in the crystallization or the reaction process into a spherical shape was developed. By this technique, needle like crystals such as salicylic acid were transformed into free flowing and directly compressible agglomerates. Sphericaly agglomerated aminophyline crystals were obtained directly from the reaction system, which could reduce the preparation processes, e. g. synthesis, crystallization and agglomeration, into only one step. Sodium theophyline monohydrate agglomerates were prepared by salting out, the rate process of which was described by a first order kinetics. Agglomerated crystals of ndw complex of indo-methacin-mepirizole were prepare with this technique; an improved therapeutic effect of the resultant crystals was expected. expected.

  • PDF

CT감시하의 경대동맥 접근법에 의한 복강 신경총 차단 (CT Guided Transaortic Celiac Plexus Neurolysis)

  • 정미영;이해규;이철우
    • The Korean Journal of Pain
    • /
    • 제4권1호
    • /
    • pp.37-41
    • /
    • 1991
  • Celiac Plexus neurolysis (C. P. N) has been commonly used to treat malignant pain of the abdominal area that is intractable. It relieves the pain effectively instead of using massive systemic narcotic analgesics. C. P. N. with modified transaortic technique was performed under C-T guidance, in which a single needle was advanced from a left posterior paramedian approach through the aorta in order to inject anesthetic agents directly into the celiac plexus. There was marked pain relief without any hemorrhagic and neurological or other complications. We found this modified transaortic method of C. P. N. to be very effective, safe and easy to perform compared with the classic two needle technique.

  • PDF