Needle 코팅을 이용한 미세 PEDOT:PSS 스트라이프 제작 (Fabrication of Fine PEDOT:PSS Stripes Using Needle Coating)

  • 이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.100-104
    • /
    • 2019
  • We have investigated the feasibility of fabricating fine stripes using needle coating for potential applications in solution-processed organic light-emitting diodes (OLEDs). To this end, we have employed an aqueous poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) solution that has been widely used as a hole injection layer (HIL) of OLEDs and performed needle coatings by varying the process parameters such as the coating gap and coating speed. As expected, the stripe width is reduced with increasing coating speed. However, the central thickness of the stripe is rather increased as the coating speed increases, which is different from other coating processes such as slot-die and blade coatings. It is due to the fact that the meniscus formed between the needle tip and the substrate varies depending sensitively on the coating speed. It is also found that the stripe width and thickness are reduced with increasing coating gap. To demonstrate its applicability to OLEDs, we have fabricated a red OLED stripe and obtained light emission with the width of about 90㎛.

한방침의 단열효과를 위한 $Al_2O_3$를 이용한 코팅연구 (Coating of heat-acupuncture needle using an $Al_2O_3$ material to improve a heat insulation)

  • 정헙제;이경엽
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.114-119
    • /
    • 2009
  • In this research, heat-acupuncture needle was coated with $Al_2O_3$ by applying a plasma spray coating method to prevent a skin burn. $Al_2O_3$, which is one of the representative bioceramics, does not have an influence on the chemical change in the body system. The ceramic coating thickness was about $100{\mu}m$. The experiments of heat conduction were performed for uncoated needle and coated needle. The results showed that the surface temperature of needle decreased as the needle was coated with $Al_2O_3$. The surface temperature of uncoated needle was about $48^{\circ}C$, while that of needle coated with $Al_2O_3$ was about $39^{\circ}C$.

소수성 Needle을 이용한 미세 유기 박막 Stripe 제작 (Fabrication of Fine Organic Thin-Film Stripes Using a Hydrophobic Needle)

  • 김종명;이진영;신동균;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제19권1호
    • /
    • pp.73-78
    • /
    • 2020
  • There appears lateral capillary force in a hydrophilic flat needle employed for the fabrication of fine organic thin-film stripes, bringing in an increase of the stripe width. It also causes the stripe thickness to increase with increasing coating speed, which is hardly observed in a normal coating process. Through computational fluid dynamics (CFD) simulations, we demonstrate that the lateral capillary flow can be substantially suppressed by increasing the contact angle of the needle end. Based on the simulation results, we have coated the outer surface of the flat needle with a hydrophobic material (polytetrafluoroethylene (PTFE) with the water contact angle of 104°). Using such a hydrophobic needle, we can suppress the lateral capillary flow of an aqueous poly(3,4-ethylenedioxythiophene): poly(4-styrenesulfonate) (PEDOT:PSS) to a great extent, rendering the stripe narrow (63 ㎛ at 30 mm/s). Consequently, the stripe thickness is decreased as the coating speed increases. To demonstrate its applicability to solution-processable organic light-emitting diodes (OLEDs), we have also fabricated OLED with the fine PEDOT: PSS stripe and observed the strong light-emitting stripe with the width of about 68 ㎛.

니들 코팅을 이용한 OLED 광 추출용 구형 마이크로렌즈 어레이 제작 (Fabrication of Spherical Microlens Array Using Needle Coating for Light Extraction of OLEDs)

  • 김주안;신영균;김기은;홍송은;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.25-31
    • /
    • 2022
  • By an aid of needle coating, we have fabricated a spherical microlens array using poly(methyl methacrylate) for potential applications in light extraction of organic light-emitting diodes. With an attempt to achieve high-density and high-aspect-ratio microlens arrays, we have investigated the coating behaviors by varying the material parameters such as the solute concentration and wettability of the poly(methyl methacrylate) solution and process parameters such as the dwell time of needle near the substrate, retract distance of needle from the substrate, and coating gap between the needle and substrate. Under the optimized coating conditions, it is demonstrated that high-aspect-ratio microlens arrays can be obtained using a coating solution with high solute concentration and a small amount of a hydrophobic solvent. It is found that the diameter and height of microlens array are decreased with increasing poly(methyl methacrylate) concentration, yet the overall aspect ratio is rather enhanced. By the addition of 5 wt% hexylamine in 35 wt% poly(methyl methacrylate) solution, we have achieved a spherical microlens with the height of 7.7 ㎛ and the width of 94.24 ㎛ (the aspect ratio of 0.082). To estimate the capability of light extraction by the microlens array, we have performed ray tracing simulations and demonstrated that the light extraction efficiency of organic light-emitting diode is expected to be enhanced up to 24%.

Fabrication of In-needle Microextraction Device Using Nichrome Wire Coated with Poly(ethylene glycol) and Poly(dimethylsiloxane) for Determination of Volatile Compounds in Lavender Oils

  • Lee, Eun Ji;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.211-217
    • /
    • 2014
  • A new needle-based device for headspace wire coated in-needle microextraction (HS-WC-INME) was fabricated using a nichrome wire coated with poly(ethylene glycol) (PEG) and poly(dimethylsiloxane) (PDMS) mixture. The proposed needle device was applied for the determination of volatile compounds in lavender and lavandin essential oils by gas chromatography. Fundamental parameters such as needle design, conditions of extraction and desorption were optimized along with the validation of the extraction and desorption efficiency. The optimal conditions were 30 min extraction at $50^{\circ}C$ and 2 min desorption at $240^{\circ}C$. The calibration curves showed good linearity with the suitable values of the coefficients of determination ($r^2$) greater than 0.99. The limits of detection for linalyl acetate, ${\beta}$-caryophyllene, linalool and (+)-limonene were 7.15, 9.04, 10.79 and 22.26 ng, respectively. Analytical recoveries were acceptable in the test samples, varying from 86.7% to 108.0%. The values of relative standard deviations for run to run showed range less than 0.9% while 3.9% through 7.2% for needle to needle. The proposed PEG-PDMS coating could be more suitable than PDMS coating to extract particular polar groups such as alcohols.

고종횡비를 갖는 용액기반 원통형 마이크로렌즈 제조 (Fabrication of Solution-Based Cylindrical Microlens with High Aspect Ratio)

  • 전경준;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.70-76
    • /
    • 2021
  • A cylindrical microlens (CML) has been widely used as an optical element for organic light-emitting diodes (OLEDs), light diffusers, image sensors, 3D imaging, etc. To fabricate high-performance optoelectronic devices, the CML with high aspect ratio is demanded. In this work, we report on facile solution-based processes (i.e., slot-die and needle coatings) to fabricate the CML using poly(methyl methacrylate) (PMMA). It is found that compared with needle coating, slot-die coating provides the CML with lower aspect ratio due to the wide spread of solution along the hydrophilic head lip. Although needle coating provides the CML with high aspect ratio, it requires a high precision needle array module. To demonstrate that the aspect ratio of CML can be enhanced using slot-die coating, we have varied the molecular weight of PMMA. We can achieve the CML with higher aspect ratio using PMMA with lower molecular weight at a fixed viscosity because of the higher concentration of PMMA solute in the solution. We have also shown that the aspect ratio of CML can be further boosted by coating it repeatedly. With this scheme, we have fabricated the CML with the width of 252 ㎛ and the thickness of 5.95 ㎛ (aspect ratio=0.024). To visualize its light diffusion property, we have irradiated a laser beam to the CML and observed that the laser beam spreads widely in the vertical direction of the CML.

조직생검용 Needle의 세라믹 코팅에 관한 연구 (A Study on the Ceramic Coating of Biopsy Needle)

  • 조성만;정협재;김만태;이경업
    • 한국정밀공학회지
    • /
    • 제26권9호
    • /
    • pp.121-126
    • /
    • 2009
  • Stainless steel 316L (STS 316L) is widely used as a material of biopsy needle. However it has a side effect that tissue can be damaged by electrochemical operation between tissue and STS 316L. Many studies have been made on the ceramic coating of biopsy needle to reduce the side effect. In this study, STS 316L was coated with three bioceramics, $Al_2O_3$, $SiO_2$ and $ZrO_2$ using a RF magnetron sputtering method. The effects of ceramic coating on the electrical conductivity and coating strength of ceramic-coated STS 316L were investigated. The results showed that the electrical conductivity of ceramic-coated STS 316L was much lower than that of uncoated STS 316L. The coating strength of $ZrO_2$-coated STS 316L was 30% and 70% higher, respectively than those of $Al_2O_3$-coated STS 316L and $SiO_2_3$-coated STS 316L.

A study on the TiN coating applied to a rolling wire probe

  • Song, Young-Sik;S. K. Yang;Kim, J.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 추계학술발표회초록집
    • /
    • pp.118-118
    • /
    • 2003
  • In a rolling wire probe, a key component of an inspection apparatus for PDP electrode patterns, the electric performance of it is known to be strongly dependent on the surface condition of a collet pin, a needle pin, and a wire. However, the collet and needle pins rotate very rapidly in contact with each other, which results in the degradation of the surface by the heat and friction and finally the formation of black wear marks on the surface after a several hundred hours test. Once the black wear marks appear on the surface, the electric resistance of the probe increases sharply and so the integrity of the probe is severely damaged. In this experiment, TiN coating, which has excellent electric conductances and good wear-resistance, has been applied on the surface of collect and needle pins for preventing the surface damages. In order to achieve the homogeneous coating with a good adhesion property, special coating substrate stages and jigs were designed and applied during coating. TiN has been deposited using 99.999% Titanium target by a DC reactive sputtering method. According to the components and jigs, processing parameters, such as DC power, RF bias and the flow rate ratio of Ar and N$_2$ used as reactive gases, has been controlled to obtain good TiN films. Detailed problems and solutions for applying the new substrate stages and jigs will be discussed.

  • PDF

졸겔법을 이용한 바륨페라이트 박막 제조 (Preparation of Barium Ferrite Thin Film by Sol-Gel Method)

  • 변태봉;조원덕;김태옥
    • 한국세라믹학회지
    • /
    • 제34권1호
    • /
    • pp.37-44
    • /
    • 1997
  • 졸겔법중 딥코팅법을 이용하여 조성비 2Fe/Ba=5.25 졸로부터 바륨페라이트 박막을 제조하였다. 졸의 겔화과정은 4단계로 구분할 수 있으며, 8$0^{\circ}C$에서 90분간 반응시켜 제조한 졸이 코팅용 졸로서 가장 적합한 특성을 나타내었다. 박막층에 형성된 침상 형태의 입자들은 기판에 수평 하게 위치하고 있었으며, 박막 두께가 증가함에 따라 그 경향은 증가하였다. 침상형 입자의 자화용이축 방향은 장축 방향이었다.

  • PDF

규산질미분말혼합시멘트계도포방수재료가 습윤환경하의 콘크리트의 미세조직에 미치는 영향 (Effect of Siliceous Slury Coating on Microstructure of Concrete under Damp Environment)

  • 오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.1-4
    • /
    • 1992
  • This paper deals with the effect of siliceous slurry coating on concrete microstructure under damp environment. This material is mixed inorganic powder consisted of silica, cement and fine sand and water. Water pressure was given on the coated surface of concrete. for estimation on effect of siliceous slurry coating, microstructure of coated concrete was observed through SEM, and chemical components of crystals were analyzed with X-ray diffraction and EDX. A number of needle and fibrous crystals were produced in microstructure. And based on X-ray diffraction and EDX, needle crystal mainly consist of Al, Si, and Ca, and it is concluded to be ettringite. Fibrous crystals consist of Ca and Si, and it to be calcium silicate hydrate.