• Title/Summary/Keyword: needle characteristics

Search Result 564, Processing Time 0.019 seconds

Needle Characteristics and Genetic Variation of Pinus pumila Natural Population in Mt. Seorak (설악산 눈잣나무 천연집단의 침엽특성과 유전변이)

  • Song, Jeong-Ho;Lim, Hyo-In;Jang, Kyung-Hwan
    • Korean Journal of Plant Resources
    • /
    • v.25 no.5
    • /
    • pp.517-522
    • /
    • 2012
  • This study was conducted to investigate the morphological and anatomical characteristics of needle and the genetic diversity of Pinus pumila Regel which is a unique and the southern peripheral population in South Korea. ANOVA test showed that there were significant differences among individuals within population in all 8 needle characteristics. Average characteristics of 66 individuals were 53.59 mm in needle length, 0.78 mm in needle width, 68.98 in needle index, 0.65 mm in needle thickness, 4.56 ea. in maximum stomata row, 3.80 ea. in minimum stomata row, 8.36 ea. in total stomata row and 1.71 ea. in resin canals, respectively. Resin canal per needle of this species ranged from one to three, depending on external type. Especially, arrangement types were 69.47% in two resin canals and 30.45% in a single resin canal. A total of 78 bands was generated from 9 selected I-SSR primers. The estimates of genetic variation were 61.5% in proportion of polymorphic bands (P), 1.698 in effective number of alleles ($A_e$), 0.388 in expected heterozygosity ($H_e$) and 0.567 in Shannon's information index (S.I.), respectively.

A Study on the Characteristics of Manufacturing and the Electromagnetic Correlations of Traditional Acupuncture Needle (전통침의 제법(製法) 특성과 전자기적 상관성 연구)

  • Hong, Do Hyun
    • Journal of Acupuncture Research
    • /
    • v.30 no.5
    • /
    • pp.95-105
    • /
    • 2013
  • Objectives : The purpose of this study is to examine the preparing methods of the traditional acupuncture needle and to interpret the electromagnetic meaning intervened in them. Methods : The overall manufacturing processes of the acupuncture needles in ancient books were surveyed. And the facts that special functional activities were carried out in common in the preparing processes were detected. The reproduction tests for the detected former functional activities were followed. Results : According to the ancient medical books, the traditional acupuncture needles were treated with the magnet through the preparing processes. The reproduction tests provided the fact that the ferromagnetic iron needles treated with the magnet were enhanced their magnetisms. And major techniques of the ancient supplementation and draining can be interpreted as magnetic or induced electromagnetic actions. Conclusions : Considering the electromagnetic characteristics of human body, the magnet treated ferromagnetic iron needles of ancient era and magnetic or induced electromagnetic interpretable manipulation techniques are the historical evidences of magnetic activities of acupuncture. So modern acupuncture therapy should be understood, studied, and reinterpreted as an electromagnetic viewpoint.

Electrohydrodynamic Pumping Characteristics of the Needle-Centered Nozzle Electrode (침심 노즐전극의 전기유체역학적 펌핑 특성)

  • Jung, Hoi-Won;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1812-1817
    • /
    • 2008
  • A cooling system for microelectronics is becoming more important as its surface heat density is projected to reach that of the sun surface. The existing technologies using natural and forced convection are limited to solve the problems. Recently, an electrohydrodynamic driven flow is studied as one of the means to cope with this problems. A new method, utilizing a needle-centered nozzle electrode, has been proposed and investigated. The I-V characteristics of the nozzle electrode for deionized water and silicone oil were significantly different from that of without liquid, which might be due to the liquid drop covered on the nozzle tip by the EHD force acting near the needle tip. Results showed that the liquid pumping rate and flow efficiency of the nozzle electrode were very high, especially for the silicone oil. Theoretical analysis also showed the effectiveness of the needle electrode centered in the ceramic nozzle, which, however, can be a means as a liquid pump.

A numerical study on the characteristics of internal flows in a gasoline direct swirl injector (직접분사식 가솔린 선회 분사기에서의 내부 유동특성에 관한 수치 해석)

  • Bae, S.H.;Moon, S.Y.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.6 no.2
    • /
    • pp.9-15
    • /
    • 2001
  • The internal flow characteristics of a gasoline direct injector have been studied to improve fuel economy and reduce exhaust emissions. Computational Fluid Dynamics (CFD) is used to examine the internal flow of the GDI with the purpose of designing the optimum geometry of the injector. This study tests orifice length, cone angle, swirl angle, orifice diameter and needle lift. The results show that optimum sizes of the orifice length, cone angle, swirl angle, orifice diameter and needle lift are 0.8mm, $140^{\circ},\;120^{\circ},\;80mm\;and\;70{\mu}m$, respectively. The size of the lift does not affect the formation of the air core signficantly near the tip of the needle compared to the ball-type needle. The vena contracta phenomenon near the orifice inlet can be released by smoothing the edge.

  • PDF

Effect of Radius of Curvature of a Corona Needle on Ionic Wind Generation (방전 침전극의 곡률반경이 이온풍 발생에 미치는 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.604-608
    • /
    • 2010
  • An electric fan for cooling high density electronic devices is limited and operated in very low efficiency. The corona discharge is utilized as the driving mechanism for an ionic gas pump, which allows for air flow control and generation with low noise and no moving parts. These ideal characteristics of ionic pump give rise to variety applications. However, all of these applications would benefit from maximizing the flow velocities and yields of the ionic pump. In this study, a needle-mesh type ionic pump has been investigated by focusing on the radius of curvature of corona needle points elevating the ionic wind velocity and efficiency. It is found that the radius of curvature of the corona discharge needle point influences significantly to produce the ionic wind and efficiency. As a result, an elevated ionic wind velocity and increased ionic wind generation yield can be obtained by optimized the radius of curvature of the corona needle electrode.

Antioxidant Activity and Quality Characteristics of Pine Needle Cookies (솔잎 쿠키의 항산화활성 및 품질특성)

  • Choi, Hae-Yeon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.10
    • /
    • pp.1414-1421
    • /
    • 2009
  • Pine needle powder has medical and functional uses. In this study, cookies were prepared using different 0.5%, 1%, 3%, 5% of pine needle powder. The total phenolic content was measured by the Folin-Ciocalteu method, and antioxidant activity was evaluated by DPPH assay. The antioxidant activity was highly correlated with the total phenolic composition of pine needle cookies (r=0.989). In addition, the quality characteristics of the pine needle cookies were estimated based on the bulk density and pH of the dough, spread factor, loss rate, leavening rate, color, texture profile analysis, and sensory evaluations. The bulk density of the dough and the hardness, total polyphenol contents and DPPH free radical scavenging activity of cookies significantly increased with increasing pine needle powder, while the pH of the dough, spread factor and L values of the cookies decreased with increasing pine needle powder content (p<0.05). Additionally, the consumer acceptability scores for the 3% pine needle cookie groups ranked significantly (p<0.05) higher than those of the other groups in appearance, taste, flavor, texture and overall preference. Taken together, the results of this study suggest that pine needle powder is a good ingredient for increasing the consumer acceptability and the functionality of cookies.

The Characteristics of Temperature Variation in Electronic Warm Acupuncture Device (전기식 온침기의 온도 변화 특성에 관한 연구)

  • Ja-Ha Lee;Jeong-Hyun Moon;U-Ryeong Chung;Soo-Hwa Hong;Gyoungeun Park;Byung Wook Lee;Won-Suk Sung;Jong-Hwa Yoon;Eun-Jung Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.184-193
    • /
    • 2023
  • Objectives : The purpose of this study is to understand the temperature characteristics depending on the thickness and material of the needle used with the Electronic Warm Acupuncture Device (EWAD). Methods : We controlled experimental environment and measured temperature changes of a silicon phantom in which K-type thermocouples were inserted at depths of 2, 7 mm. EWAD perfomed with acupuncture needles of various thicknesses (0.25×60 mm, 0.40×60 mm, and 0.50×60 mm) and materials (Gold 0.40×50 mm). We set non-needle (only heated with EWAD skin heater) group as a control group. Results : The maximum temperature and temperature changes of 0.40 mm, 0.50 mm needle group were significantly higher than the non-needle group. The highest temperature range in all needle groups was 0.50 mm needle group (41.44±0.31℃). However, the 0.25 mm needle group was not significantly different from the non-needle group. Maximum temperature of gold needle group was significantly higher than stainless steel needle group. Temperature changes of gold needle group were higher than stainless steel group at the depth of 7 mm. Conclusions : It was found that needle thickness and material of acupuncture had an effect on the temperature of the EWAD. When performing EWAD treatment, consideration of thickness and material of acupuncture is needed. Future research is needed using phantoms that can reflect actual clinical situations and better mimic the human body.

Investigation of Micromorphological Characteristics of Acupuncture Needle Tip Using SEM in Korea(2) (주사전자현미경(SEM)을 이용한 일회용침 끝의 미세 형태에 대한 관찰(2))

  • Jang, In-soo;Park, Jong-bae;Song, Beom-yong;Lee, Chang-hyun;Kim, Hyun-soo
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.151-158
    • /
    • 2003
  • Objective: There have not been so many study about the quality of acupuncture needle tip. In order to ensure safe acupuncture treatment, the quality of needle tip is essential. Therefore we investigated the current condition of the tip of the acupuncture needles in Korea. Methods: We have selected the needles that made by 8 companies in Korea, and selected 50 pieces from 1000 pieces each company by randomized methods. and observed the tip of each needle using a scanning electron microscope at ${\times}800$ magnification. Results & Discussion: We found that needles had several defects such as scratch marks on the surface, metallic scuff, lumps and irregularities of the needle tips, stubbed or malformed tips, tips of point off-center, peeled off coated tips. There was much difference on the quality of needle among the manufacturer, and some needles seem to need to do- thorough quality control. It is necessary to intensify quality management and a concentrated control on manufacturing process of acupuncture needles.

  • PDF

Effects of Needle Response on Spray Characteristics In High Pressure Injector Driven by Piezo Actuator for Common-Rail Injection System

  • Lee Jin Wook;Min Kyoung Doug
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1194-1205
    • /
    • 2005
  • The common-rail injection systems, as a new diesel injection system for passenger car, have more degrees of freedom in controlling both the injection timing and injection rate with the high pressure. In this study, a piezo-driven injector was applied to a high pressure common-rail type fuel injection system for the control capability of the high pressure injector's needle and firstly examined the piezo-electric characteristics of a piezo-driven injector. Also in order to analyze the effect of injector's needle response driven by different driving method on the injection, we investigated the diesel spray characteristics in a constant volume chamber pressurized by nitrogen gas for two injectors, a solenoid-driven injector and a piezo-driven injector, both equipped with the same injection nozzle with sac type and 5-injection hole. The experimental method for spray visualization was based on back-light photography technique by utilizing a high speed framing camera. The macroscopic spray propagation was geometrically measured and characterized in term of the spray tip penetration, spray cone angle and spray tip speed. For the evaluation of the needle response of the above two injectors, we indirectly estimated the needle's behavior with an accelerometer and injection rate measurement employing Bosch's method was conducted. The experimental results show that the spray tip penetrations of piezo­driven injector were longer, on the whole, than that of the solenoid-driven injector. Besides we found that the piezo-driven injector have a higher injection flow rate by a fast needle response and it was possible to control the injection rate slope in piezo-driven injector by altering the induced current.

Physical, chemical, mechanical, and micromorphological characterization of dental needles

  • de Oliveira Monteiro, Marco Antonio;Antunes, Alberto Nogueira da Gama;Basting, Roberta Tarkany
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.2
    • /
    • pp.139-153
    • /
    • 2021
  • Background: In anesthetic techniques, touching bones can cause needle bending. Theoretically, a needle should support such deflection without fracturing. However, it is possible that a needle may fracture depending on the quality and type of needle used. This study evaluated the physical, chemical, and micromorphological characteristics of long and short dental anesthetic needles, as well as the mechanical properties of flexural load and bending resistance when needles are subjected to different bending angles. Methods: Long and short needles (30G, Jets, Misawa, Selekto, Terumo, Unoject and 27G, Dencojet, Injex, Jets, Misawa, Procare, Setoject XL, Terumo) were evaluated. Scanning electron microscopy was used to evaluate the needle bevels and energy-dispersive X-ray spectroscopy was used for the chemical analysis of needle compositions. Flexural loading and bending strength assessments were performed using a universal testing machine by bending the needles (n = 5) to angles of 30°, 60°, or 90°, or until fracture occurred. Results: The Injex 27G, Jets 27G, and Septoject XL 27G needles were all less than 30 mm in length. There were small percentage variations in the chemical compositions of the needles. Superior smoothness was observed for the Unoject 30G needle, which exhibited the highest fracture resistance at 60°. The Jets 30G needle exhibited greater resistance to fractures at 90°. The Procare 27G needle exhibited the highest load resistance to bending, followed by the Septoject XL 27G needle, and both needles were tied for the lowest fracture resistance. No needle fractured when bent to 30° or at less than three bends to 60° or 90°. Conclusions: Greater needle resistance to bending increases the probability of early fracturing. Thinner and shorter needles are more resistant than longer and thicker needles. Performing a single bend does not result in any significant risk of fracture or obliterate the lumen, allowing for the continued passage of anesthetic liquid.