• Title/Summary/Keyword: neck tilt angle

Search Result 21, Processing Time 0.025 seconds

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

An Convergence Analysis of Muscle Characteristics, Muscle Activity and Posture in Patients with Cervicogenic Headache (경추성 두통 환자의 근육 특성과 자세 및 근활성도의 융복합적 분석)

  • Yoon, Jong-Hyuk
    • Journal of Digital Convergence
    • /
    • v.19 no.6
    • /
    • pp.265-271
    • /
    • 2021
  • This study aimed to define the diagnostic criteria for cervicogenic headache and propose an efficient method of clinical evaluation and physical therapy. Fifteen patients with cervicogenic headache and 15 healthy individuals were recruited and categorized into the test group and the control group, respectively. The groups were compared in terms of muscle characteristics, muscle activity and posture, and the intervariable correlations were analyzed for the test group. A significant between-group difference was found in the stiffness of the suboccipital muscle and the tone and stiffness of the upper trapezius muscle (p<.001). In posture comparison, a significant difference was noted in neck tilt angle and the T1 slope angle (p<.05). The activity of the sternocleidomastoid muscle was also significantly different between the groups (p<.001). When the correlations among the muscle characteristics, the posture, and the activity of the sternocleidomastoid muscle were analyzed for the test group, a positive correlation was found between the tone and the stiffness of the suboccipital muscle (p<.001) and between the tone and the stiffness of the upper trapezius muscle (p<.001). The findings of this study suggest a more efficient approach for the assessment and treatment of cervicogenic headache patients. It is considered that, further studies including more subjects of various job categories and comparing the outcomes.

Reliability and Convergent Validity of Standing Posture Measurement Using a Mobile Application in Forward Head Posture (전방머리자세 성인을 대상으로 모바일 어플리케이션을 이용한 자세정렬 측정의 신뢰도 및 수렴 타당도 연구)

  • Kang, Hyojeong;Kim, Minkyu;Yang, Hoesong;Lee, Wanhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • Purpose : The aim of this study was to assess the intra- and inter-rater reliability and validity of measurements of head, neck, and pelvis posture using a mobile application in subjects with forward head posture. Methods : Forty-eight volunteers (22 men, 26 women) participated in this study. Two raters independently examined whole body picture images in a lateral standing posture with arms crossed using a CA-Smart Posture Reminder (CA-SPR), and a rater took and calculated posture images twice to assess reliability. We measured five parameters: craniovertebral angle 1 (CVA1), anterior shoulder translation (AST), pelvic tilt (PT), knee angle (KA), and ankle angle (AA) in the subject's sagittal plane using CA-SPR. We examined whole spine X-ray images in the same position to assess validity. We measured four variables in the subjects: CVA2, translation distance (AHT), anterior pelvic plane (APP), and sacral slope (SS). The intra- and inter-rater reliability were calculated using the intraclass correlation coefficient (ICC). Convergent validity was calculated using Pearson's correlation coefficient. Results : The intra-rater reliability (ICC=.889 -.989) and inter-rater reliability (ICC=.800 -.980) were excellent for all variables measured using CA-SPR. The variables measured using CA-SPR and X-ray were significantly positively correlated (r=.623, p<.01). However, the correlation of the variables in the pelvis was not statistically significant. Conclusion : This study shows that a mobile application (CA-SPR) is a useful tool for measuring head and neck posture in subjects with forward head posture. However, further study is needed to measure pelvic variables when using a mobile application.

Effects of Neck and Shoulder Exercise Program on Spino-Pelvic Alignment in Subject with Forward Head Posture (목과 어깨근육 운동프로그램이 전방머리자세의 척추-골반 정렬 변화에 미치는 영향)

  • Kang, Hyojeong;Yang, Hoesong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose : Excessive computer use frequently results in musculoskeletal disorders of the neck and shoulder such as forward head posture (FHP). The purpose of this study was to investigate effects of neck and shoulder exercise program on spino-pelvic alignment and the correlation between change in head and neck posture and spino-pelvic alignment in FHP. Methods : The study included 44 participants with FHP. The participants performed the exercise for correction of FHP 2-3 times a week for 4 weeks. We examined whole spine X-ray images in the lateral standing position with both arms crossed. We measured anterior head translation distance (AHT), craniovertebral angle (CVA), cervical lordosis (CL), thoracic kyphosis (TK), lumbosacral lordosis (LSL), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI) of the subjects. The association between change in AHT and each spino-pelvic parameter was also subjected to Pearson's correlation coefficient analysis. Results : There were statistically significant differences before and after exercise in the parameters of AHT, CVA, and SS (p<.05). Significant negative correlation was observed between the change in AHT and CVA (r=-.768, p<.001), and CL (r=-.388, p<.05). There was significant positive correlation between the change in AHT and SS (r=.328, p<.05), and PI (r=.333, p<.05). However, no significant correlation was observed in change in AHT with that of TK, LSL, and PT. Conclusion : Based on the above results, we conclude that there is a relationship between change in AHT, which is a parameter associated with forward displacement of the head, and that of CVA, CL, SS, and PI after exercise in cases of FHP.

T1 Slope and Cervical Sagittal Alignment on Cervical CT Radiographs of Asymptomatic Persons

  • Park, Ji Hoon;Cho, Chul Bum;Song, Jun Ho;Kim, Seok Woo;Ha, Yoon;Oh, Jae Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.356-369
    • /
    • 2013
  • Objective : We performed a retrospective analysis of medical records and radiographic images of patients who never underwent spinal treatment including diagnosis. The objective of this study is to explain the biomechanical and physiologic characteristics of cervical alignment related to thoracic inlet angle including T1 slope changes in each individual. Methods : We reviewed the cervical CT radiographs of 80 patients who visited ENT outpatient clinic without any symptom, diagnosis and treatment of cervical spine from January 2011 to September 2012. All targeted people were randomized without any prejudice. We assessed the data-T1 slope, Cobb's angle C2-7, neck tilt, sagittal vertical axis (SVA) C2-7 and thoracic inlet angle by the CT radiographs. Results : The relationships between each value were analyzed and we concluded that Cobb's angle C2-7 gets higher as the T1 slope gets higher, while the SVA C2-7 value decreases. Conclusion : We propose that the T1 slope is background information in deciding how much angle can be made in the cervical spinal angle of surgical lordotic curvature, especially severe cervical deformity.

A Therapeutic Approach Based on Motor Development in Congenital Muscular Torticollis: A Case Report (선천성 근육 사경 환아에 대한 운동 발달적 치료 접근: 증례보고)

  • Ryu, Je-Yong;Kim, Yu-Jin;Sung, Ju-Yeon;Shim, Jae-Hun;Lee, Gyu-Wan;Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.77-84
    • /
    • 2006
  • Although conservative management of congenital muscular torticollis (CMT) has been well documented, relatively little is known about the response to the treatment. The purposes of this case report were to describe the use of a therapeutic approach based on motor development in physical therapy intervention for an infant with CMT and to report the result of the treatment. The patient was a 20-day-old baby boy with left CMT presenting muscular mass in the left sternocleidomastoid muscle. The angle of the lateral head tilt was 20 degrees. The size of muscular mass was 5.3 mm in ultrasonography. Intervention included ultrasonic therapy, soft tissue massage, passive and active range of motion exercises, motor developmental therapy, and parent instruction. The procedures of motor developmental therapy and changes in the amount of lateral head tilt were documented using photography. The size of the mass was decreased to .3 mm before the 5-month follow-up. The patient also maintained a midline head position in the supine position and a midline head alignment during all functional activities. A therapeutic approach based on motor development is a beneficial method for reducing an asymmetrical head and neck position, and facilitating normal development as a component of physical therapy intervention.

  • PDF

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.12 no.4
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF

Preservation of Motion at the Surgical Level after Minimally Invasive Posterior Cervical Foraminotomy

  • Lee, Young-Seok;Kim, Young-Baeg;Park, Seung-Won;Kang, Dong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.433-440
    • /
    • 2017
  • Objective : Although minimally invasive posterior cervical foraminotomy (MI-PCF) is an established approach for motion preservation, the outcomes are variable among patients. The objective of this study was to identify significant factors that influence motion preservation after MI-PCF. Methods : Forty-eight patients who had undergone MI-PCF between 2004 and 2012 on a total of 70 levels were studied. Cervical parameters measured using plain radiography included C2-7 plumb line, C2-7 Cobb angle, T1 slope, thoracic outlet angle, neck tilt, and disc height before and 24 months after surgery. The ratios of the remaining facet joints after MI-PCF were calculated postoperatively using computed tomography. Changes in the distance between interspinous processes (DISP) and the segmental angle (SA) before and after surgery were also measured. We determined successful motion preservation with changes in DISP of ${\leq}3mm$ and in SA of ${\leq}2^{\circ}$. Results : The differences in preoperative and postoperative DISP and SA after MI-PCF were $0.03{\pm}3.95mm$ and $0.34{\pm}4.46^{\circ}$, respectively, fulfilling the criteria for successful motion preservation. However, the appropriate level of motion preservation is achieved in cases in which changes in preoperative and postoperative DISP and SA motions are 55.7 and 57.1%, respectively. Based on preoperative and postoperative DISP, patients were divided into three groups, and the characteristics of each group were compared. Among these, the only statistically significant factor in motion preservation was preoperative disc height (Pearson's correlation coefficient=0.658, p<0.001). The optimal disc height for motion preservation in regard to DISP ranges from 4.18 to 7.08 mm. Conclusion : MI-PCF is a widely accepted approach for motion preservation, although desirable radiographic outcomes were only achieved in approximately half of the patients who had undergone the procedure. Since disc height appears to be a significant factor in motion preservation, surgeons should consider disc height before performing MI-PCF.

Adult Patients with Congenital Muscular Torticollis Treated with Bipolar Release : Report of 31 Cases

  • Lee, Gun Sang;Lee, Myung Ki;Kim, Woo Jae;Kim, Ho Sang;Kim, Jeong Ho;Kim, Yun-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Objective : We assessed the surgical results of bipolar release in 31 adult patients with uncorrected congenital muscular torticollis (CMT) and more than 12 months of follow-up. Methods : Thirty-one patients underwent a bipolar release of the sternocleidomastoid muscle (SCM) and were retrospectively analyzed. The mean follow-up period was 14.9 months (range, 12-30). The mean age at time of surgery was 30.3 years (range, 20-54). Patients were evaluated with a modified Lee's scoring system, cervicomandibular angle (CMA) measurement, and a global satisfaction rating scale using patient self-reporting. Results : The modified Lee's scoring system indicated excellent results in 4 (12.9%) patients, good in 18 (58.1%), and fair in 9 (29.0%) at the last follow-up after surgery. The improvements in neck movement and head tilt were statistically significant (p<0.05). The preoperative mean CMA was $15.4^{\circ}$ (range, 5.4-29.0), which was reduced to a mean of CMA of $6.3^{\circ}$ (range, 0-25) after surgery (p<0.05). The global satisfaction rating scale was 93.7% (range, 90-100). A transient sensory deficit on the ipsilateral lower ear lobe was noted in three cases. No significant permanent complications occurred. Conclusion : Bipolar release of the SCM is a safe and reliable technique for the treatment of CMT in adults.

Posture Correction Guidance System using Arduino (아두이노를 활용한 자세교정 유도 시스템)

  • Kim, Donghyun;Kim, Jeongmin;Bae, Woojin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.369-372
    • /
    • 2021
  • These days, people spend more time sitting at a desk for studies or work. Also, because people continue to use computers, smartphones, and tablet PCs often during break times, their posture is getting worse. Maintaining a position of bad posture for an extended period of time causes problems with the musculoskeletal system related to the neck, shoulders, and spine. Additionally, problems such as physical fatigue and posture deformation are predicted to expand to a wide range of age groups. Therefore, the core function of the system we are developing is to ensure correct sitting posture and to receive alert notifications via the created mobile application. To create the system, a flex sensor, pressure sensor, and tilt sensor are attached to a chair and utilized. The flex sensor detects and compares the amount of bending in the chair's posture and transmits this value to an Arduino Uno R3 board. Additionally, information such as body balance and incline angle are collected to determine whether or not the current sitting posture is correct. When the posture is incorrect, a notification is sent through the mobile application to indicate to the user and the monitoring app that their posture is not correct. The system proposed in this study is expected to be of great help in future posture-related research.

  • PDF