• Title/Summary/Keyword: neck area

Search Result 745, Processing Time 0.024 seconds

A Study on the Forming Process Development off Long-neck Flange Using a Long Pipe (긴 관을 이용한 롱넥플랜지 성형공정 개발에 관한 연구)

  • 최간대;강우진;배원병;조종래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.699-704
    • /
    • 2002
  • The pipe with a long-neck flange is widely used in power plants, chemical plants, and shipbuilding companies. New the pipe with a long-neck flange is manufactured by welding a thick flange to a pipe. But this long-neck flange pipe has some deflects in the welding region such as unfitting and local thermal fatigue, which weaken the strength around the neck of the flange. Moreover, after welding the flange, the contacting surfaces of the flange have to be machined flat. So, that is uneconomical. Therefore, to solve the above problems of the long-neck flange pipe, a new process, which has no defects around the flange neck, is required. In this study, three forming processes are suggested to get an enhanced long-neck flange. First suggested process consists of conical terming and flange forming. Second and third suggested processes consist of the bulging of a long pipe locally heated by induction coils and the flange forming. The differences between second and third suggestions are the thickness and local heating area of the pipe. That is, the thickness of the initial pipe of third suggestion is larger than that of the final product, and the local heating area is smaller than that of second suggestion. These three suggestions fur forming a long-neck flange are simulated by FE analyses with a commercial cede DEFORM 2D. Especially, the theoretical result of FE analysis on the first suggestion fur forming a long-neck flange is verified by the experiment with aluminum 6063 pipes. From the theoretical and experimental results, it is concluded that three suggested processes are very useful in order to manufacture the pipe with a long-neck flange without any deflects.

  • PDF

A Study on the Forming Process Development of a Long-neck Flange Using a Long Pipe (긴 관을 이용한 롱넥플랜지 성형공정 개발에 관한 연구)

  • Choe, Gan-Dae;Gang, U-Jin;Bae, Won-Byeong;Jo, Jong-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.8
    • /
    • pp.212-219
    • /
    • 2002
  • The pipe with a long-neck flange is widely used in power plants, chemical plants, and shipbuilding companies. Now the pipe with a long-neck flange is manufactured by welding a thick flange to a pipe. But this long-neck flange pipe has some defects in the welding region such as unfitting and local thermal fatigue, which weaken the strength around the neck of the flange. Moreover, after welding the flange, the contacting surfaces of the flange have to be machined flat. So, that is uneconomical. Therefore, to solve the above problems of the long-neck flange pipe, a new process, which has no defects around the flange neck, is required. In this study, three forming processes are suggested to get an enhanced long-neck flange. First suggested process consists of conical forming and flange forming. Second and third suggested processes consist of the bulging of a long pipe locally heated by induction coils and the flange forming. The differences between second and third suggestions are the thickness and local heating area of the pipe. That is, the thickness of the initial pipe of third suggestion is larger than that of the final product, and the local heating area is smaller than that of second suggestion. These three suggestions for forming a long-neck flange are simulated by FE analyses with a commercial code DEFORM 2D. Especially, the theoretical result of FE analysis on the first suggestion for forming a long-neck flange is verified by the experiment with aluminum 6063 pipes. From the theoretical and experimental results, it is concluded that three suggested processes are very useful in order to manufacture the pipe with a long-neck flange without any defects.

Non Functioning Parathyroid Cyst : A Case Report (비기능성 부갑상선 낭종 1예)

  • Choi, Dong-Il;Yim, Sang-Ho;Moon, Seung-Young;Hong, Ki-Hwan
    • Korean Journal of Head & Neck Oncology
    • /
    • v.25 no.2
    • /
    • pp.174-177
    • /
    • 2009
  • Parathyroid cyst are rare lesion of the neck and superior mediastinum. They are classified as either functional or nonfunctional based on the presence or absence of hyperparathyroidism. They typically present as a palpable neck mass, or as an incidental finding during neck surgery. So, it must be included within the differential diagnosis of a neck lump. A 48-year old woman was admitted to our hospital for evaluation of left anterior neck mass. Physical finding showed soft, movable, non-tender mass on the lower left third of the neck. Laboratory findings revealed normal thyroid function and normal serum calcium level. On previous history, patient underwent two times sono-guided fine needle aspiration at local clinic, and about 10cc clear watery aspirate was noted. Computerized tomography findings showed non-enhancing hypodense cystic lesion on left thyroid area with tracheal deviation to right side. Preoperative diagnosis was thyroid cyst, and thyroidectomy was planed. Intra-operative finding showed huge cystic mass occupying the left thyroid area and smooth, shiny, semitransparent thin cyst wall was noted, which was loosely attached to the thyroid. The cyst was easily dissected free from the thyroid and surrounding tissues. After cyst removal, pathological study confirmed as a parathyroid cyst.

A Case of Liposarcoma Arising in the Neck (경부에 발생한 지방육종 1예)

  • Park, Chang Ho;Ji, Yong Bae;Kim, Kyung Rae;Tae, Kyung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.28 no.2
    • /
    • pp.139-142
    • /
    • 2012
  • Liposarcoma is the second most common soft tissue sarcoma in adult. The incidence of liposarcoma in the head and neck area is very uncommon. Liposarcoma of the neck usually express non-tender palpable mass. The main treatment of cervical liposarcoma is surgical excision and adjuvant radiation therapy. Herein, we report a case of cervical liposarcoma with the review of literature.

A Case of Ectopic Thyroid with Clinical Evaluation of Fifteen Cases (이소성 갑상선 1례 및 국내 증례의 임상적 고찰)

  • 고중화;안성윤;송정환;박승구
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.1
    • /
    • pp.55-61
    • /
    • 1999
  • The authors recently experienced a case of ectopic thyroid. A 15-year-old female patient visited to ENT department with the complaint of the submental neck mass. On physical examination, the mass was relatively firm, non tender and 3$\times$2cm in size. Oral cavity examination revealed 0.5$\times$0.5cm sized pink colored mass near the foramen cecum area. Suspecting ectopic thyroid, thyroid function test, thyroid scan, neck computed tomogram scan were performed. Thyroid scan revealed a functioning thyroid on the lingual and submental area without normal uptake in the anterior neck area. Thyroid (unction test was normal. Pre-contrast computed tomogram scan revealed an ectopic thyroid in the lingual and submental area. A review of literature concerning ectopic thyroid was discussed.

  • PDF

Effects of Aroma Neck and Shoulder Massage and Red LED irradiation on cutaneous microcirculation in the neck area (아로마 목·어깨 마사지와 Red LED 조사가 목 피부 미세혈류에 미치는 영향)

  • Yang Yang;Seunghee Bae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.393-405
    • /
    • 2024
  • This study investigates the effects of aroma neck and shoulder massage and Red LED irradiation on cutaneous microcirculation in the neck area. In this study, 30 women aged 20 to 60 were randomly assigned to three experimental groups. Group A (n=10) received Red LED irradiation after aroma neck and shoulder massage, while Group B (n=10) rested for 15 minutes after aroma neck and shoulder massage. Group C (n=10) only received Red LED irradiation. The results showed significant main effects of time between the baseline and post-treatment measurements in Groups A and B (F = 29.883, p < 0.001, 𝜂2 = 0.624), however, the main effects of the groups were not significant (F = 0.202, p = 0.659, 𝜂2 = 0.011), but there was a significant interaction between group and time (F = 8.452, p = 0.001, 𝜂2 = 0.320). There were no significant statistical differences in cutaneous microcirculation in the neck area after treatment in Group C (p > 0.05, Cohen's d = 0.202). In conclusion, Red LED treatment demonstrates limited effects on cutaneous microcirculation in the neck area, differentiating with the results of Groups A and B. Specifically, the combined effect of aroma neck and shoulder massage and Red LED treatment in Group A was not significant.

Robotic Lateral Compartment Selective Neck Dissection in Well-Differentiated Thyroid Carcinoma (갑상선 분화암에서 로봇을 이용한 측경부 림프절 절제술)

  • Tae, Kyung
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2011
  • Robotic thyroidectomy has been developed to minimize neck scarring, and several authors have described its feasibility and safety, and have reported surgical outcomes comparable with conventional open thyroidectomy. The da Vinci surgical system robot provides a three-dimensional $10-12{\times}$magnified view of the surgical area. It also provides hand-tremor filtration, fine motion scaling, and precise and multi-articulated hand-like motions. Recently, robotic technology has also been applied to lateral compartment neck dissection in thyroid cancer. We have developed a new novel selective neck dissection procedure by a gasless unilateral axillo-breast (GUAB) approach with a da Vinci Surgical System for well-differentiated thyroid carcinoma to avoid a long visible neck scar. Based on our early experience, robotic selective neck dissection by GUAB approach is a safe, feasible and cosmetically excellent procedure. It can be an alternative to conventional open surgery in the highly selected patients with well-differentiated thyroid carcinoma. The oncologic safety of robotic selective neck dissection should be verified with long-term follow-up data.

  • PDF

Estimation of Volume and Surface Area for Reconstruction of Tongue (혀의 재건을 위한 부피 및 표면적의 측정)

  • Park, Ha-Na-Ro;Kim, Hee-Jin;Jeong, Woo-Jin;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.1
    • /
    • pp.27-31
    • /
    • 2011
  • Purpose : Anterolateral thigh and radial forearm flap is the most important fasciocutaneous flap widely used for reconstruction of tongue. One important purpose of flap is replacing the volume of tongue but still there is no data about the surface area and volume to be reconstructed after glossectomy. In this paper, surface area and volume is estimated from the 3-dimensionally reconstructed MRI images to see which flap is more ideal and to give the reference value for reconstruction. Materials and Methods : With coronal MRI image, tongue including only the intrinsic muscle is delineated in every section and reconstructed 3-dimensionally and calculated the volume and surface area to be reconstructed according to the degree of glossectomy. This volume and surface area was compared with the volume of anterolateral thigh and radial forearm flap. Results : The volume and surface area to be reconstructed in hemiglossectomy was $39.0{\pm}4.0cm^3$ and $31.8{\pm}2.7cm^2$ respectively. The average thickness of anterolateral thigh flap is $9.4{\pm}2.8mm$ and that of radial forearm is $3.8{\pm}1.0mm$. Comparing the curve of tongue surface area and volume with the volume of flap, the anterolateral thigh flap has more ideal volume to replace the defect. Conclusions : The surface area and volume requested for reconstruction could be suggested and the anterolateral thigh flap has more ideal volume for reconstruction of glossectomy defect.

Two Cases of Progressive Transformation of Germinal Centers(PTGC) in Head and Neck Area (두경부에 발생한 Progressive Transformation of Germinal Centers(PTGC) 환자 2예)

  • Han, Won Gue;Kim, Tae Min;Yoon, Hee chul;Yum, Gun hwee;Oh, Kyoung Ho;Kwon, Soon Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.34-38
    • /
    • 2015
  • Progressive transformation of germinal centers(PTGC) is a rare benign lymph node enlargement characterized by chronic lymphadenopathy and the presence of germinal centers with fused and expanded mantles within a lymph node that are 3-5 times the size of a typical reactive follicle. Although PTGC is reported in 3.5-10% of chronic lymphadenopathy, head and neck surgeons do not often experience this condition and its clinical implications. Althoug PTGC is benign disease, it could not be excluded the association with other malignant lymphoid diseases. Therefore, periodic follow up of PTGC patient could be required. We report two cases at this study ; a 16 years old man who visited out-patient clinic due to palpable mass of right cervical area, several months ago, and a 35 years old man who visited out-patient clinic for evaluating right cervical mass. Both of two patients were diagnosed with PTGC. In this study, we focus on the clinic-pathologic features of this uncommon disease along with other literature reviews.

  • PDF

The Correlation between Cross-sectional Area of Lumbar Paraspinal Muscles and Walking Ability in the Patients with Lumbar Spinal Stenosis (척추관 협착증 환자의 보행능력과 요추 주변 근육 단면적의 상관관계 연구)

  • Kim, Min Chul;Seo, Young Hoon;Lee, Sang Min;Kim, Yu Jong;Hong, Je Rak;Yoo, Do Hyun;Kim, Ji Su;Kim, Tae Gyu;Choi, Jae Young;Kim, Tae-Hun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.3
    • /
    • pp.109-117
    • /
    • 2016
  • Objectives The purpose of this study was to investigate the correlation between walking ability of lumbar spinal stenosis patients and the cross-sectional area (CSA) of lumbar paraspinal muscles. Methods This study was carried out on 62 lumbar spinal stenosis patients who had limited walking abilities because of neurogenic claudication (NC). All patients received more than 2 weeks of complex treatment at Mokhuri Neck&Back Hospital. CSA of lumbar paraspinal muscles was measured from axial T2-weighted MRI and divided by CSA of adjacent vertebral body to avoid influence of body statues (RCSA-Relative CSA). Pain Free Walking Distance and Numerical Rating Scale (NRS) was measured before and after treatment. Results The Pain Free Walking Distance had significantly increased in patients who had bigger RCSA of psoas muscle (r=0.313, p<0.05). Conclusions The psoas muscle can be a predictive factor for restoring walking ability of lumbar spinal stenosis patients who have limitations walking.