• 제목/요약/키워드: near-infrared

검색결과 1,682건 처리시간 0.035초

Investigation of a series of near-infrared absorbing heptamethine cyanine dyes

  • 윤혜수;박수열;신승림;신종일;안경룡;이상오;오성근;전근
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2009년도 제41차 학술발표회
    • /
    • pp.115-116
    • /
    • 2009
  • In this study, near-infrared absorbing dyes, namely, new rigidified heptamethine cyanine dyes were synthesized and investigated their properties. The cyanine dyes have been synthesized by a condensation reaction between a quanternary salt containing as activated methyl group and an unsaturated bisaldehyde or its equivalent. We were investigated the synthesis of new rigidified heptamethine cyanine and related the compounds with near infrared absorption. The full spectroscopic characterization of all cyanine were described. Absorption properties in the near-infrared region may cause these dyes to the potential used in bio-probe, optical recording media materials.

  • PDF

근적외선 분광분석법을 이용한 유량종자의 원산지 판별 (Discrimination of Oil Seeds According to Geographical Origin Using Near Infrared Reflectance Spectroscopy)

  • 권혜순
    • 한국응용과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.21-24
    • /
    • 1999
  • Sesame seed (Sesamum indicum L.) is an important seasoning in Korea and most korean consumer tend to eat the korean sesame seed as the best than other ones produced in oriental countries such as China and Japan. Near infrared reflectance spectroscopy (NIRS) was applied for discrimination according to geographical origin (Korea, China and so on) of sesame seeds. Near-infrared spectroscopy among the many kinds of techniques could provide a rapid screening, low cost solution to discriminate geographical origin of sesame seed. The objective of this study is to determine if NIR technique could be used to discriminate between the korean sesame seed and non-korean sesame seed by using the new method. Rapid, precise and nondestructive analysis method for determination of the geographic origin of sesame seeds were discriminated relative accurately according to geographical origin using PLS regression method.

태양전지 실리콘 웨이퍼를 위한 실험계획법 기반 근적외선 광학계의 최적조건 선정 (Optimal Parameter Selection of Near-Infrared Optics Based Design of Experiment for Silicon Wafer in Solar Cell)

  • 서형준;김경범
    • 반도체디스플레이기술학회지
    • /
    • 제12권3호
    • /
    • pp.29-34
    • /
    • 2013
  • Solar cell has been considered as renewable green energy. Its silicon wafer thickness is thinner due to manufacturing cost and accordingly micro cracks is often generated in the process. Micro cracks result in bad quality of solar cell, and so their accurate and reliable detection is required. In this paper, near-infrared optics system is newly designed based on the analysis of near-infrared transmittance characteristics and its important parameters are optimally selected using the design of experiment for micro crack detection in solar cell wafer. The performance of the proposed method is verified using several experiments.

근적외분광분석법을 이용한 인도메타신의 정량분석 (Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제47권5호
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

근적외분광분석법을 이용한 생쥐꼬리에서의 비침습 혈당 정량시 장기간 측정에 따른 변이 요인의 보정 (Compensation of Variation from Long-Term Spectral Measurement for Non-invasive Blood Glucose in Mouse by Near-Infrared Spectroscopy)

  • 백주현;강나루;우영아;김효진
    • 약학회지
    • /
    • 제48권3호
    • /
    • pp.177-181
    • /
    • 2004
  • Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.

850 nm 파장대 근적외선과 갈바닉 전류기반의 눈가 주름 치료기 개발 및 영상 분석을 통한 치료성능 검증 (Design of 850 nm Near Infrared and Galvanic Current Based Eyeglass-Type Device for Periorbital Wrinkle Treatment and Verification of Treatment Performance through Image Analysis)

  • 안성수;권기진
    • 한국멀티미디어학회논문지
    • /
    • 제21권12호
    • /
    • pp.1379-1386
    • /
    • 2018
  • In this paper, we proposed eyeglass type periorbital wrinkle treatment device for reducing and improving periorbital wrinkles using near infrared LED of 850nm wavelength and galvanic current. The proposed periorbital wrinkle treatment device is equipped with a control system based on F-PCB. It consists of eight near-infrared LEDs and four indicator LEDs for treatment of right and left periorbital wrinkles. The eyeglass frame is coated with conductive material, so galvanic current can flow to the skin of periorbital wrinkle contacted to it. One male adult in the mid-40s was allowed to use the device for 10 minutes every day for 4 weeks. After 4 weeks, image analysis using optical equipment for measuring wrinkles indicated that wrinkle indexes were reduced.

Effects of Wearable Near-Infrared Rays on Knee Pain in Korean Elderly Adults

  • Lee, Jin-Min;Kim, Kye-Ha
    • 통합자연과학논문집
    • /
    • 제13권4호
    • /
    • pp.121-127
    • /
    • 2020
  • To investigate the effects of wearable near-infrared ray-emitting knee pads on knee pain among elderly adults in Korea. Randomized controlled trial evaluating the effects of near-infrared rays (NIR) on knee pain in Korean elderly adults. Five community-based research facilities (two welfare centers, a senior citizen center, and two churches). Forty-seven participants aged 65 years and older who had experienced knee pain. The experimental group (n = 25) wore NIR-emitting knee pads for one month at nighttime while sleeping. The control group (n = 22) wore knee pads without NIR. Demographic characteristics, intensity and duration of knee pain, amount of analgesic medication used, range of motion, gait speed, and health-related quality of life were collected using questionnaires. The experimental group showed decreased intensity (t = -6.17, p < 0.001) and duration (t = -3.34, p = 0.002) of knee pain and reduced analgesic use (t = -2.30, p = 0.026) compared to the control group. NIR may be an effective non-pharmacological option for relieving knee pain in elderly adults.

식품 산업에서의 근적외선 분광법을 이용한 비파괴 분석법 동향 (Trends in non- destructive analysis using near infrared spectroscopy in food industry)

  • 박종락
    • 식품과학과 산업
    • /
    • 제55권1호
    • /
    • pp.2-22
    • /
    • 2022
  • Near-infrared spectroscopy (NIRS) is one of the representative non-destructive and eco-friendly analysis methods used for rapid analysis of various ingredients in the food industry. To develop analysis model with NIRS, Chemometrics are applied after pre-treatment of spectrum. Many studies have been reviewed on the analysis of general and functional components for agricultural and livestock products. In the case of livestock products, some studies have been conducted for on-line analysis. This study investigated results on various samples and component applying near-infrared spectroscopy. Furthermore, the results according to sample condition were compared. It was confirmed that NIRS is applied to various fields in the food industry.

DEEP INFRARED SURVEYS OF STAR FORMING REGIONS IN THE MWG AND LMC

  • NAKAJIMA YASUSHI
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.173-174
    • /
    • 2005
  • On behalf of the IRSF/SIRIUS group, I introduce some recent results from our deep near-infrared surveys (J, Hand Ks bands, limiting magnitude of Ks=17) toward star forming regions in the Milky Way Galaxy (MWG) and Large Magellanic Cloud (LMC) with the near-infrared camera SIRIUS. We discovered a rich population of low-mass young stellar objects associated with the W3 and NGC 7538 regions in the MWG based on the near-infrared colors arid magnitudes. The high sensitivity of our survey enables us to detect intermediate-mass pre-main sequence stars, i.e. HAEBE stars, even in the LMC. We detected many HAEBE candidate stars in the N159/N160 complex star forming region in the LMC with the IRSF 1.4-m telescope. Spatial distributions of the young stellar objects indicate the sequential cluster formation in each star forming region in the complex and large scale (a few ${\times}$ 100 pc) sequential cluster formation over the entire complex.