• 제목/요약/키워드: near- and far-fault earthquakes

검색결과 50건 처리시간 0.023초

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

퍼지관리제어기법을 이용한 스마트 면진 벤치마크 건물의 제어 (Control of Smart Base-isolated Benchmark Building using Fuzzy Supervisory Control)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권4호
    • /
    • pp.55-66
    • /
    • 2005
  • 본 논문에서는 스마트 면진장치를 효과적으로 제어하기 위하여 퍼지관리제어기를 개발하였고 그 효율성을 검토하였다. 이를 위하여 1세대 스마트 면진 벤치마크 건물을 이용하여 수치해석을 수행하였다. 대상 벤치마크 구조물은 부정형의 평면을 가지고 있는 8층 건물이고 탄성베어링과 MR 감쇠기로 이루어진 스마트 면진장치가 설치되어 있다. 본 논문에서는 다목적 유전자 알고리즘을 이용하여 원거리 지진과 근거리 지진에 대하여 각각 면진구조물을 효과적으로 제어할 수 있는 하위 퍼지제어기를 개발한다. 최적화과정에서는 구조물의 최대 및 RMS 가속도와 면진층 변위의 저감이 목적으로 사용된다. 벤지마크 건물에 지진하중이 가해지면 두 개의 하위 퍼지제어기에서는 각각 다른 명령전압이 제공되는데 이 명령전압들은 퍼지관리제어기의 추론과정에 기반하여 실시간으로 참여율이 조절되어 하나의 명령전압으로 조합된다. 수치해석을 통하여 제안된 퍼지관리제어기법을 사용함으로써 상부구조물의 응답과 면진층의 변위를 효과적으로 줄일 수 있음을 확인할 수 있다.

교각의 노후도 영향에 따른 강합성 상자형 거더교의 지진응답 평가 (Seismic Response Evaluation of Composite Steel-Concrete Box Girder Bridge according to Aging Effect of Piers)

  • 신수봉;홍이영;문이호;송종걸
    • 한국전산구조공학회논문집
    • /
    • 제33권5호
    • /
    • pp.319-329
    • /
    • 2020
  • 현재 우리나라에서 운영 중인 교량 중 30년 이상 된 교량이 전체의 약 11%를 차지할 정도로 노후교량의 수가 증가하고 있다. 따라서 교량의 노후화에 따른 영향을 고려한 내진성능 평가방법의 개발이 필요하다고 볼 수 있다. 예제 교량으로는 포트받침, 탄성고무받침과 납-고무받침을 가진 3가지의 강합성 상자형 거더교를 선정하고, opensees 프로그램을 사용하여 구조해석모델을 작성하였다. 본 연구에서는 교량의 노후도를 교각의 주철근과 띠철근의 부식에 의한 면적의 감소로 반영하였다. 교각의 노후화 정도로는 5%, 10%, 25%, 50%의 4가지 조건을 사용하였다. 입력지진으로는 근거리 지진과 원거리 지진을 각각 40개씩 사용하였으며, 노후화 정도에 따른 예제교량의 교각에 대한 최대변위와 최대 전단력 응답을 구하여 비교하였다. 노후도가 증가할수록 힘-변위 관계에서 교각의 강도 저하가 발생함을 알 수 있으며, 이로 인하여 교각의 변위응답이 증가함을 알 수 있다. 교각의 노후도에 따른 변위응답과 전단저항능력의 영향을 분석하기 위하여 변위비(Dratio)와 전단력비(Fratio)를 정의하여 평가하였다. 예제교량의 고유주기가 길어질수록 노후도에 따른 변위비(Dratio)의 증가가 크게 나타남을 알 수 있으며, 전단력비(Fratio)의 감소 경향은 작게 나타남을 알 수 있다.

전력설비의 내진설계를 위한 변전소 구조형식에 따른 가속도 증폭계수의 평가 (Evaluation of Acceleration Amplification Factors Based on the Structural Type of Substation for the Seismic Design of Power Facilities)

  • 박성제;전낙현;황경민;문지호;송종걸
    • 한국전산구조공학회논문집
    • /
    • 제33권3호
    • /
    • pp.159-169
    • /
    • 2020
  • 변전소 구조물 내부에 설치되는 전력설비의 내진설계 시 사용되는 변수인 가속도 증폭계수는 미국, 일본과 국내의 변전소 내진설계기준에서 제시되어 있다. 국내 설계기준에 제시된 가속도 증폭계수는 미국, 일본의 설계기준에서 제시된 계수와는 달리 변전소 구조물의 층수가 4층 이상일 경우에는 동적해석을 수행하여 가속도 증폭계수를 구하게 되어 있다. 국내의 변전소 구조물은 대부분 층수가 4~5층이므로 기존의 가속도 증폭계수는 실제 변전소 구조물에 적용하기에 미흡한 상황이다. 국내 변전소 구조물 형식에 적합한 가속도 증폭계수를 제시하기 위하여 대표적인 7가지 구조형식의 변전소 구조물에 대하여 가속도 증폭계수를 평가하였다. 가속도증폭계수는 변전소 구조물에 대하여 원거리 지진과 근거리 지진을 사용하여 내부-구조물 응답스펙트럼을 작성하여 이로부터 평가하였다. 미국, 일본 전력설비 내진설계 기준에 따른 각각의 가속도 증폭계수 αJ, αA는 근거리 및 원거리 지진을 사용한 동적 해석으로 구한 가속도 증폭계수에 비하여 다소 과대평가하는 경향이 있다.

Piezoelectric friction dampers for earthquake mitigation of buildings: design, fabrication, and characterization

  • Chen, Genda;Garrett, Gabriel T.;Chen, Chaoqiang;Cheng, Franklin Y.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.539-556
    • /
    • 2004
  • In this paper, the design, fabrication and characterization of a piezoelectric friction damper are presented. It was sized with the proposed practical procedure to minimize the story drift and floor acceleration of an existing 1/4-scale, three-story frame structure under both near-fault and far-field earthquakes. The design operation friction force in kip was numerically determined to range from 2.2 to 3.3 times the value of the peak ground acceleration in g (gravitational acceleration). Experimental results indicated that the load-displacement loop of the damper is nearly rectangular in shape and independent of the excitation frequency. The coefficient of friction of the damper is approximately 0.85 when the clamping force on the damper is above 400 lbs. It was found that the friction force variation of the damper generated by piezoelectric actuators with 1000 Volts is approximately 90% of the expected value. The properties of the damper are insensitive to its ambient temperature and remain almost the same after being tested for more than 12,000 cycles.

완만한 이력거동 시스템에 대한 비탄성 변위비의 평가 (Evaluation of Inelastic Displacement Ratios for Smooth Hysteretic Behavior Systems)

  • 송종걸
    • 한국지진공학회논문집
    • /
    • 제15권3호
    • /
    • pp.11-26
    • /
    • 2011
  • 비탄성 변위비는 최대 선형 탄성변위에 대한 최대 비탄성 변위의 비로서 정의된다. 비탄성 변위비는 비탄성 응답의 계산을 하지 않고도 최대 탄성변위로부터 최대 비탄성변위를 직접적으로 평가 가능하게 한다. 비탄성 변위비에 대한 기존의 연구는 이선형 또는 강성저하시스템과 같은 분할선형시스템에 국한되었다. 본 논문에서는 근거리 및 원거리 지진을 받는 완만한 곡선형 이력거동 시스템의 비탄성 변위비에 대하여 연구하였다. 두 단계의 회귀분석 과정을 통하여 비탄성 변위비에 대한 간편식을 제안하였다.

PSC-Box 교량에 적용된 탄성고무 받침과 납-고무 받침의 노후화 효과를 고려한 지진응답의 평가 (Evaluation of Seismic Response Considering the Ageing Effect of Rubber and Lead-Rubber Bearings Applied to PSC Box Bridge)

  • 정연희;송종걸;신수봉
    • 한국지진공학회논문집
    • /
    • 제23권6호
    • /
    • pp.311-319
    • /
    • 2019
  • The number of aged bridges is increasing so that bridges over 30 years old account for about 11% of all bridges. Consequently, the development of a seismic performance evaluation method that considers the effects of ageing is essential for a seismic retrofitting process for improvement of the seismic safety of existing old bridges. Assessment of the damage situation of bridges after the recent earthquakes in Korea has been limited to the bearings, anchor, and concrete mortar on piers. The purpose of this study is to evaluate the seismic responses of PSC box girder bridges by considering the ageing effect of rubber bearings (RBs) and lead-rubber bearings (LRBs). The modification factor proposed by AASHTO is used to take into account the ageing effect in the bearings. PSC box girder bridges with RBs and LRBs were 3D modeled and analyzed with the OpenSEES program. In order to evaluate the ageing effect of RBs and LRBs, 40 near fault and 40 far field records were used as the input earthquakes. When considering the effect of ageing, the displacement responses and shear forces of bridge bearings (RBs and LRBs) were found to increase mostly under the analytical conditions. It was shown that the effect of ageing is greater in the case of RBs than in the case of LRBs.

Collapse Vulnerability and Fragility Analysis of Substandard RC Bridges Rehabilitated with Different Repair Jackets Under Post-mainshock Cascading Events

  • Fakharifar, Mostafa;Chen, Genda;Dalvand, Ahmad;Shamsabadi, Anoosh
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.345-367
    • /
    • 2015
  • Past earthquakes have signaled the increased collapse vulnerability of mainshock-damaged bridge piers and urgent need of repair interventions prior to subsequent cascading hazard events, such as aftershocks, triggered by the mainshock (MS). The overarching goal of this study is to quantify the collapse vulnerability of mainshock-damaged substandard RC bridge piers rehabilitated with different repair jackets (FRP, conventional thick steel and hybrid jacket) under aftershock (AS) attacks of various intensities. The efficacy of repair jackets on post-MS resilience of repaired bridges is quantified for a prototype two-span single-column bridge bent with lap-splice deficiency at column-footing interface. Extensive number of incremental dynamic time history analyses on numerical finite element bridge models with deteriorating properties under back-to-back MS-AS sequences were utilized to evaluate the efficacy of different repair jackets on the post-repair behavior of RC bridges subjected to AS attacks. Results indicate the dramatic impact of repair jacket application on post-MS resilience of damaged bridge piers-up to 45.5 % increase of structural collapse capacity-subjected to aftershocks of multiple intensities. Besides, the efficacy of repair jackets is found to be proportionate to the intensity of AS attacks. Moreover, the steel jacket exhibited to be the most vulnerable repair intervention compared to CFRP, irrespective of the seismic sequence (severe MS-severe or moderate AS) or earthquake type (near-fault or far-fault).

Study of using the loss rate of bolt pretension as a damage predictor for steel connections

  • Chui-Hsin Chen;Chi-Ming Lai;Ker-Chun Lin;Sheng-Jhih Jhuang;Heui-Yung Chang
    • Earthquakes and Structures
    • /
    • 제24권2호
    • /
    • pp.81-90
    • /
    • 2023
  • The maximum drifts are important to the seismic evaluation of steel buildings and connections, but the information can hardly be obtained from the post-earthquake field investigation. This research studies the feasibility of using the loss rate of bolt pretension as an earthquake damage predictor. Full-scale tests were made on four steel connections using bolted-web-welded-flange details. One connection was unreinforced (UN), another was reinforced with double shear plates (DS), and the other two used reduced beam sections (RBS). The preinstalled strain gauges were used to control the pretensions and monitor the losses of the high-strength bolts. The results showed that the loss rate of bolt pretension was highly related to the damage of the connections. The pretensions lost up to 10% in all the connections at the yield drifts of 0.5% to 1%. After yielding of the connections, the pretensions lost significantly until fracture occurred. The UN and DS connections failed with a maximum drift of 4 %, and the two RBS connections showed better ductility and failed with a maximum drift of 6%. Under the far-field-type loading protocol, the loss rate grew to 60%. On the contrary, the rate for the specimen under near-fault-type loading protocol was about 40%. The loss rate of bolt pretension is therefore recommended to use as an earthquake damage predictor. Additionally, the 10% and 40% loss rates are recommended to predict the limit states of connection yielding and maximum strength, respectively, and to define the performance levels of serviceability and life-safety for the buildings.

MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 퍼지제어 (Fuzzy control of hybrid base-isolator with magnetorheological damper and friction pendulum system)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권1호통권41호
    • /
    • pp.61-70
    • /
    • 2005
  • 본 연구에서는 하이브리드 면진장치가 설치된 단자유도 구조물에 대하여 진동대 실험을 수행하였다. 본 연구에서 사용된 하이브리드 면진장치는 네 개의 FPS와 한 개의 MR 감쇠기로 구성하였다. 다양한 크기 및 특성을 가진 지진하중을 하이브리드 면진장치가 설치된 구조물에 가하여 진동제어 성능을 평가하였다. 본 연구에는 준능동 MR 감쇠기의 저항력을 효과적으로 조절하기 위하여 퍼지제어기를 사용하였고 구조물에 부착된 계측기를 통하여 변위 및 가속도를 피드백으로 이용한다. 수동 및 준능동 제어기법을 사용하여 얻은 구조물의 응답을 서로 비교하였고 그 결과 FPS와 MR 감쇠기의 조합으로 다양한 특성의 하중을 받는 구조물의 진동제어를 효과적으로 수행할 수 있음을 알 수 있다.