• Title/Summary/Keyword: near power

Search Result 1,797, Processing Time 0.033 seconds

Computational Flow Analysis of a Cross-Flow Fan by LES (LES에 의한 관류홴의 전산유동해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.20-28
    • /
    • 2010
  • The computational flow analysis using LES technique was carried out to investigate the flow characteristics of a RAC chassis consisting of a rear-guider, a stabilizer and a cross-flow fan. The commercial SC/Tetra software was used in this analysis. In view of the results so far achieved, the distribution trends of static pressure and velocity vector of central region except the edges of a CFFan are similar regardless of the number of revolution, and an eccentric vortex exists around the bottom blade of a CFFan. Also, a reverse flow is found in the region between stabilizer and CFFan. Moreover, near the edges of a CFFan, an eccentric vortex is separated to two vortexes. Also these vortexes increase the velocity near a rear-guider, and guide the flow near a rear-guider into stabilizer inlet. Therefore, the reverse flow region is formed in the bottom of a CFFan.

A Study for the Change and Distribution of Far Sighted and Near Sighted Astigmatism Power according to Age (연령에 따른 원·근거리 난시의 굴절력 변화에 대한 연구)

  • Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.25-36
    • /
    • 2007
  • We researched the change of astigmatism power when the fixation point moved from far distance to near distance. Astigmatism power was measured by using both eyes open-view auto-refractometer. We divided the ages between 5 and 67 years old into 12 groups with 1,598 healthy eyes(male-698 eyes and female-900 eyes) without eyes problems and experiences of eyes operations. The mean power in far astigmatism showed that with-the-rule of the total astigmatism: -0.79D, with-the-rule of the corneal astigmatism: -1.07D and against-the-rule of the residual astigmatism : -0.79D were found most respectively. The correlation between cornea astigmatism and total astigmatism was y=0.7493 x + 0.5661 r=0.6510, residual astigmatism and total astigmatism was y=0.248 x - 0.5926 r=0.2598 and corneal astigmatism and residual astigmatism was y=-0.4439 x - 0.1813 r=-0.5551 in the far distance. The mean power in near astigmatism showed that with-the-rule of total astigmatism : -0.92D, with-the-rule of corneal astigmatism : -1.12D, against-the-rule of residual astigmatism : -0.87D were found most respectively. In the near distance, The correlation between corneal astigmatism and total astigmatism was y=0.6872 x + 0.5934 r=0.6204, residual astigmatism and total astigmatism was y=0.303 x - 0.6066 r=0.3165, corneal astigmatism and residual astigmatism was y=-0.46 x - 0.0626 r=-0.5322. When the fixation point moved far distance to near distance, the differences of power according to the type of astigmatism were total astigmatism: $-0.07D{\pm}0.44D$, corneal astigmatism: $-0.04D{\pm}0.54D$ residual astigmatism:$0.01D{\pm}0.53D$. Most of astigmatism refractive power was increased except for oblique-the -astigmatism. When the fixation point moved far distance to near distance, the change of astigmatism refractive power showed total astigmatism: 540 eyes(33.7%), corneal astigmatism: 638 eyes(39.9%), residual: 841 eyes(52.6%).

  • PDF

Near-ground wind and its characterization for engineering applications

  • Crandell, Jay H.;Farkas, William;Lyons, James M.;Freeborne, William
    • Wind and Structures
    • /
    • v.3 no.3
    • /
    • pp.143-158
    • /
    • 2000
  • This report presents the findings of a one-year monitoring effort to empirically characterize and evaluate the nature of near-ground winds for structural engineering purposes. The current wind engineering practice in the United States does not explicitly consider certain important near-ground wind characteristics in typical rough terrain conditions and the possible effect on efficient design of low-rise structures, such as homes and other light-frame buildings that comprise most of the building population. Therefore, near ground wind data was collected for the purpose of comparing actual near-ground wind characteristics to the current U.S. wind engineering practice. The study provides data depicting variability of wind speeds, wind velocity profiles for a major thunderstorm event and a northeaster, and the influence of thunderstorms on annual extreme wind speeds at various heights above ground in a typical rough environment. Data showing the decrease in the power law exponent with increasing wind speed is also presented. It is demonstrated that near-ground wind speeds (i.e., less than 10 m above ground) are likely to be over-estimated in the current design practice by as much as 20 percent which may result in wind load over-estimate of about 50% for low-rise buildings in typical rough terrain. The importance of thunderstorm wind profiles on determination of design wind speeds and building loads (particularly for buildings substantially taller than 10 m) is also discussed. Recommendations are given for possible improvements to the current design practice in the United States with respect to low-rise buildings in rough terrain and for the need to study the impact of thunderstorm gust profile shapes on extreme value wind speed estimates and building loads.

Development of a Dynamic Downscaling Method for Use in Short-Range Atmospheric Dispersion Modeling Near Nuclear Power Plants

  • Sang-Hyun Lee;Su-Bin Oh;Chun-Ji Kim;Chun-Sil Jin;Hyun-Ha Lee
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.28-43
    • /
    • 2023
  • Background: High-fidelity meteorological data is a prerequisite for the realistic simulation of atmospheric dispersion of radioactive materials near nuclear power plants (NPPs). However, many meteorological models frequently overestimate near-surface wind speeds, failing to represent local meteorological conditions near NPPs. This study presents a new high-resolution (approximately 1 km) meteorological downscaling method for modeling short-range (< 100 km) atmospheric dispersion of accidental NPP plumes. Materials and Methods: Six considerations from literature reviews have been suggested for a new dynamic downscaling method. The dynamic downscaling method is developed based on the Weather Research and Forecasting (WRF) model version 3.6.1, applying high-resolution land-use and topography data. In addition, a new subgrid-scale topographic drag parameterization has been implemented for a realistic representation of the atmospheric surface-layer momentum transfer. Finally, a year-long simulation for the Kori and Wolsong NPPs, located in southeastern coastal areas, has been made for 2016 and evaluated against operational surface meteorological measurements and the NPPs' on-site weather stations. Results and Discussion: The new dynamic downscaling method can represent multiscale atmospheric motions from the synoptic to the boundary-layer scales and produce three-dimensional local meteorological fields near the NPPs with a 1.2 km grid resolution. Comparing the year-long simulation against the measurements showed a salient improvement in simulating near-surface wind fields by reducing the root mean square error of approximately 1 m/s. Furthermore, the improved wind field simulation led to a better agreement in the Eulerian estimate of the local atmospheric dispersion. The new subgrid-scale topographic drag parameterization was essential for improved performance, suggesting the importance of the subgrid-scale momentum interactions in the atmospheric surface layer. Conclusion: A new dynamic downscaling method has been developed to produce high-resolution local meteorological fields around the Kori and Wolsong NPPs, which can be used in short-range atmospheric dispersion modeling near the NPPs.

A Technique for Fast Sampling Measurement of Digital Frequency Relay (디지털주파수계전기의 고속 샘플링추정기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.185-190
    • /
    • 2006
  • Frequency and phasor are the most important quantities in power system operation because they can reflect the whole power system situation. Frequency reflects the dynamic energy balance between load and generating power, while operators use phasor to constitute the state of system and, moreover, phasor based line relays are currently used in most power systems. So frequency and phasor are regarded as indices for the operating power systems in practice. The proposed technique is suitable for estimation near-nominal, nomina), and off-nominal frequencies. It is useful in designing microprocessor-based relays and meters that need to measure power system frequency. Performance test results, using signals from EMTP source and Excel program, indicate that the proposed technique can provide accurate estimates within 16ms. Maximum estimation errors observed during testing are of the order of 0.006Hz for nominal, near-nominal, and off-nominal frequencies. The proposed technique provides accurate estimates in presence of noise and harmonics and in case ground fault. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Design of UHF CMOS Front-ends for Near-field Communications

  • Hamedi-Hagh, Sotoudeh;Tabesh, Maryam;Oh, Soo-Seok;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.817-823
    • /
    • 2011
  • This paper introduces an efficient voltage multiplier circuit for improved voltage gain and power efficiency of radio frequency identification (RFID) tags. The multiplier is fully integratable and takes advantage of both passive and active circuits to reduce the required input power while yielding the desired DC voltage. A six-stage voltage multiplier and an ultralow power voltage regulator are designed in a 0.13 ${\mu}m$ complementary metal-oxide semiconductor process for 2.45 GHz RFID applications. The minimum required input power for a 1.2 V supply voltage in the case of a 50 ${\Omega}$ antenna is -20.45 dBm. The efficiency is 15.95% for a 1 $M{\Omega}$ load. The regulator consumes 129 nW DC power and maintains the reference voltage in a 1.1% range with $V_{dd}$ varying from 0.8 to 2 V. The power supply noise rejection of the regulator is 42 dB near a 2.45 GHz frequency and performs better than -32 dB from 100 Hz to 10 GHz frequencies.

A Study on Review of the Current Noise Impact Assessment for the Power Plant (발전소 플랜트 소음영향평가 현황 및 민원사례를 통한 개선방향 연구)

  • Choung, Tae-Ryang;Park, Young-Min;Son, Jin-Hee;Cho, Man-Hee;Hong, Woong-Ki;Song, Jeong-Un
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.941-949
    • /
    • 2012
  • The various plants including power plants have been increased near downtown in accordance with the policy objective of rising the power feed rate and development projects. As a result of these various plants near residential area, noise damage complaints has been raised very often. The power plant is included with the range of environmental impact assessment project. Nevertheless, environmental noise issues regarding construction of these power plants have arisen. Accordingly it is time to consider the environmental and social issues of plants noise in accordance with the government's policy objectives of increased power production. In this study, we reviewed the current noise impact assessment and we also sought solutions to these issues. In order to minimize the problem of noise impact on neighborhood and residents, we intended to propose alternative method of 3D simulation in dealing with these issues.

Power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal

  • Cao, Xiaoling;Yan, Liangjun
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.251-261
    • /
    • 2018
  • With the urbanization in recent years, the power line interference noise in electromagnetic signal is increasing day by day, and has gradually become an unavoidable component of noises in magnetotelluric signal detection. Therefore, a kind of power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal is put forward in this paper. The method first uses wavelet decomposition to change single-channel signal into multi-channel signal, and then takes advantage of blind source separation principle of independent component analysis to eliminate power line interference noise. There is no need to choose the layer number of wavelet decomposition and the wavelet base of wavelet decomposition according to the observed signal. On the treatment effect, it is better than the previous power line interference removal method based on independent component analysis. Through the de-noising processing to actual magnetotelluric measuring data, it is shown that this method makes both the apparent resistivity curve near 50 Hz and the phase curve near 50 Hz become smoother and steadier than before processing, i.e., it effectively eliminates the power line interference noise.