A study on the ventilation characteristics and design of transverse ventilation system for road tunnel (도로터널 횡류환기방식의 환기특성 및 시스템 설계 관한 연구)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.305-315
    • /
    • 2018
  • In this study, the ventilation characteristics and the relationships between the required ventilation flow rate and the ventilation system flow rate was investigated by numerical method for the optimum design of the transverse ventilation and semi-transverse ventilation system in road tunnels. The following results were obtained. In supply exhaust transverse ventilation system, the system supply-exhaust air flow rate is theoretically equal to the difference between the required ventilation flow rate and natural ventilation flow rate. However, it is shown that it increases by about 10% in the analysis results. And, in the case of the longitudinal air flow rate is increased by installed jet fans, ventilation system air flow rate is reduced. However, as the longitudinal air flow rate increases, the concentration of pollutants in the tunnel decreases, so the exhaust effect of pollutants decreases, and the effect of reducing the system air flow rate is decreased. In case of semi-transverse with only air supply, ventilation system air flow rate is equal to required ventilation air flow rate when tunnel inlet velocity is negative, but results is shown it is increased within about 13.3%. Also, it was found that ventilation effect can not be expected even if the jet fans are increased when the tunnel inlet velocity is negative.

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

A Study on Subway ventilation improve a program (지하철 환기구 개선 방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1970-1974
    • /
    • 2010
  • This paper is how to improve contaminated air by the pollutant from vehicles through ventilators and entrance at the underground station. We are looking for the environment management to take care of customers. There is two ventilation systems. One is natural ventilation system, the other is forced ventilation system. Usually, subway ventilators were installed low on the sidewalk. There are lots of craps on the ventilators, so these things interrupt influx of outside air. But the gas from the vehicles comes into the station through entrance. There is lots of noise while ventilations run. So we install the supply air vents away from the road for the customers. If it's difficult, we cover around the ventilator with clear plastic plates more than 2M heights. We also install silencer on the ventilators. We install the air curtains on the entrances to prevent dust from outside. Seoul Metropolitan has a plan to make 60M deep underground road. To improve underground road air quality, ventilators should be installed that consider the above information.

  • PDF

Estimation of Mean Air Exchange Rate and Generation Rate of Nitrogen Dioxide Using Box Model in Residence (주택에서 Box Model을 이용한 평균 환기율 및 이산화질소 발생량 추정)

  • Bae, Hyeon Ju;Yang, Won Ho;Son, Bu Sun;Kim, Dae Won
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.645-653
    • /
    • 2004
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate these factors by application of multiple measurements. For the total duration of 30 days, daily indoor and outdoor $NO_2$ concentrations were measured in 30 houses in Brisbane, Australia, and for 21 days in 40 houses in Seoul, Korea, respectively. Using a box model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated, Sub-sequently, the ventilation and source strength were estimated. In Brisbane, the penetration factors were $0.59\pm0.14$ and they were unaffected by the presence of a gas range. During sampling period, geometric mean of natural ventilation was estimated to be $l.l0\pm1.5l$ ACH, assuming a residential $NO_2$ decay rate of 0.8 hr^{-1}$ in Brisbane. In Seoul, natural ventilation was $1.15\pm1.73$ ACH with residential $NO_2$ decay rate of 0.94 hr^{-1}$ Source strength of $NO_2$ in the houses with gas range $(12.7\pm9.8$ ppb/hr) were significantly higher than those in houses with an electric range $(2.8\pm2,6$ ppb/hr) in Brisbane. In Seoul, source strength in the houses with gas range were $l6.8\pm8.2$ ppb/hr. Conclusively, indoor air quality using box model by mass balance was effectively characterized.

A Study on Behavior Characteristics of Volatile Organic Compound Caused by Ventilation in a Room (통풍에 의한 휘발성 유기화합물의 실내 거동 특성에 대한 연구)

  • Kim, Jang-Woo;Chung, Jin-Do
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1011-1016
    • /
    • 2006
  • Recently, volatile organic compound(VOC) has been noted as a main cause of air pollution. VOC, with its toxic and offensive odor, is hazardous to health. Furthermore indoor, underground and hish-rise buildings are preferable living spaces. People spend more than 80% of the day indoor, so indoor air pollution is a matter of importance. In Korea, from 2004, 10 types of indoor pollutants in public facilities have been identified. However, there is no standard for individual VOC, so the regulation has not yet effectively been carried out. In this study, we have studied on the diffusion of Benzene in a room using a numerical analysis for various air-controlled conditions consisted of door, window and ventilation system. This study investigates spatial concentration distribution and time-history of room-averaged benzene concentration for several cases. The results of this study show that when the room is ventilated by a small fan only for 30 minutes, the average concentration of benzene is decreased a very little, thus the impact to human body would be serious compared to the case of natural ventilation by window and door, In the case of natural ventilation by window and door, if the wind speed is higher than 0.5m/s, it takes small than 4 minutes for benzene to spread to the target concentration of $1.2mg/m^3$.

Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed (옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가)

  • Jo, Hyun-Joung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.334-342
    • /
    • 2022
  • The stringent air environment conservation act forced to build an indoor dome for coal storage. However, it causes some problems due to accumulation of fly ash and harmful substances inside. To solve this problem, this study analyzed the pattern of internal airflow and the amount of ventilation for an indoor coal yard. Overall, the airflow inside the indoor coal yard tended to move to the southwest facing the mountain. In addition, sea-breeze was blowing from the northern louver window facing the sea, where airflow was flowing in. The total flow rate flowing into the indoor coal yard was 918,691 m3/h, and the number of natural ventilation per hour was 0.6 times. Therefore, it is proposed to install a forced ventilation device at the location where internal air flow is concentrated.

Investigations and Analyses of Duck Breeding Facilities in Jeollanam-do Province, Korea (전남지역 오리 사육시설 실태 조사 및 분석)

  • Kwon, Kyeong-seok;Yang, Kayoung;Kim, Jong-bok;Kim, Jung-kon;Jang, Donghwa;Choi, Sungmin;Lee, Sang-yeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Number of duck and its breeding facilities have been steadily decreasing for financial and social issues in Korea. Therefore, the 'turning point' for duck industry is strongly demanded. In this study, the questionary survey was carried out to provide backgrounds for developing policy and technology for duck breeding farms. The questionary survey aimed to investigate the information of operation strategy of farm, ventilation, cooling and heating. The total number of survey respondents was 74. In case of facility type, 55.4% of respondents stated they used greenhouse type, 31.3% for winch-curtain type, and 2.7% for windowless type (mechanically ventilated facility). More than 85% of the facilities were using 'natural ventilation', it meant that these situation can restrict the not only environmental control but also the supply policy for 'smart farm' of the Government. 44.6% used the combination of the cross-ventilation method and roof-ventilation method for ventilation operation in summer season, and 31.1% followed only the cross-ventilation method. In case of winter season, 36.5% used the cross-ventilation method, and 33.3% used the combination of cross and roof-ventilation, method. For the ventilation strategy, about 86.5% depended on farmer's experience. In case of heating and cooling, 79.7% were using kerosene heater for winter season, and 43.2% were using mist-spray for summer season, respectively. More than 75% stated that cooling and heating strategies were based on farmer's experience. From the analyses of the survey results, a few proposals for developing policy and technology for duck breeding farm was suggested.

Case studies related to the installation of tunnel ventilation towers (터널 환기탑 국내·외 설치사례연구)

  • Park, Jun Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.3
    • /
    • pp.293-304
    • /
    • 2022
  • Recently, the frequency of installation of ventilation towers is increasing due to the planning and construction of underground roads and long tunnel. In this study, implications and points for improvement were considered through investigation and analysis of the installation standards related to ventilation towers in tunnels and analysis of ventilation tower installation cases in domestic and overseas tunnel case study. As a result of this study, when selecting the location and height of the ventilation tower, it is recommended to determine the final ventilation tower type through a consultation process with residents, considering the environmental impact caused by the emission of pollutants, the harmonious arrangement with the surrounding landscape, and the efficient use of the above-ground site nearby ventilation tower. In addition, from the design stage, it is judged that a detailed review of reducing the height of the ventilation tower through air quality simulation is necessary for natural harmony with the surrounding topography and to prevent civil complaints.

A Study on the elementary school design based on ecological approach - Focused on the shared space of the elementary school of in Osaka Japan and Busan Korea - (Ecoloy개념을 적용한 초등학교 공간디자인에 관한 연구 - 일본 오사카시 초등학교와 부산시 초등학교 사례분석 -)

  • Yun, Ji-Young;Song, Ju-Eun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2004.05a
    • /
    • pp.136-140
    • /
    • 2004
  • This study starts from the premise that future elementary school should be designed based on ecological approach. In order to restore the emotionality of children, school should provide and protect our natural environment by greening and energy saving. The research was conducted in Osaka and Busan to analyze the present condition of elementary schools in terms of ecology. The shared spaces such as halls, corridors, stairs and rest areas of fourteen schools were chosen and analyzed by the design analysis list. The list included the guidelines including greening, lighting, heating and cooling, ventilation and use of materials. The results showed that Korean schools require void space for more natural lighting, ventilation and insulation, while Japanese schools have problems in use of environmentally friendly materials, natural lighting and interior greening. This study reveals that ecological approach including greening and natural lighting should be considered in future elementary school design to make the school environment more agreeable and economical.