• 제목/요약/키워드: natural tracer

검색결과 70건 처리시간 0.022초

추적자조사기법을 활용한 사용종료매립장 연직차수벽 성능평가 (Performance Evaluation of Close Waste Landfill Vertical Slurry Wall(SCW) by Tracer Method)

  • 이동건;오영인;김관호;조숙희;박은숙
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1245-1252
    • /
    • 2010
  • Many industrialized countries are confronted with a difficulty about reuse of closed waste landfill. facilities. Especially, the demand of closed waste landfill maintenance and reuse nearby urban area has been increased, because of the shortage of usable land and extend of urban area. For the safe reuse of closed waste landfill, the most important check point is the effect of waste landfill on environment abound them. However, the non-sanitary closed waste landfill generally have no leachate lining system, therefore, the in-situ lining system such as sheet-pile, and vertical slurry wall etc. was needed to prevent the leachate outgoing from the waste landfill. In this paper present the case history of performance evaluation of vertical slurry wall by tracer tests.

  • PDF

방사성 동위원소를 이용한 자연하천의 2차원 추적자 실험 (Two-dimensional Tracer Tests in Natural Rivers Using Radioisotope)

  • 서일원;백경오;전태명
    • 대한토목학회논문집
    • /
    • 제26권2B호
    • /
    • pp.161-170
    • /
    • 2006
  • 본 연구에서는 하천에서 오염물의 혼합 특성 연구를 위한 실험 방법으로서 방사성 동위 원소를 이용한 추적자 실험 방법을 제시하였다. 현장 실험시 추적자로서 방사성 동위원소를 사용할 경우 장점은 미량의 주입으로도 추적자의 감지가 용이하며 감지할 수 있는 범위 또한 넓다. 그리고 하상에 흡 탈착되는 추적자의 양이 비교적 작아 정확하면서 효율적으로 실험을 수행할 수 있다. 본 연구에서는 국내 자연하천 중 다양한 사행형태를 갖는 만곡구간을 선정하여 현장조사 및 추적자 실험을 7회 수행하였다. 실험에서 수집된 수리량 및 농도자료로부터 추적자의 2차원적 거동을 분석하고, 다양한 산정법을 통해 종횡 분산계수를 산출하였다. 그 결과 만곡이 심한 구간에서는 추적운의 중심이 만곡의 외측에 치우쳐 이동함을 확인하였고, 종분산계수 및 횡분산계수가 직선구간에 비해 증가함을 확인하였다.

사행수로에서의 유속 및 분산특성에 관한 실험적 연구 (An Experimental Study of Flow and Dispersion Characteristics in Meandering Channel)

  • 박성원;서일원
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.799-802
    • /
    • 2008
  • General behaviors based on hydraulic characteristics of natural streams and channels have been recently analyzed and developed via various numerical models. However in the states of natural hydraulics, an experimental research must be performed simultaneously with the mathematical analysis due to effects of hydraulic properties such as meander, sediment, and so on. In this study based on 2-D advection-dispersion equation, flow and tracer experiments were performed in the S-curved meandering laboratory channel with a rectangular cross-section. The channel was equipped with instrument carriages which was equipped with an auto-traversing system to be used with velocity measuring sensors throughout the depth and breadth of the flow field. To measure concentration distribution of the salt solution was adjusted to that of the flume water by adding methanol and a red dye (KMnO4) was added to aid the visualization of the tracer cloud, the tracer was instantaneously injected into the flow as a full-depth vertical line source by the instantaneous injector and the initial concentration of the tracer was 100,000 mg/l. The secondary current as well as the primary flow pattern was analyzed to investigate the flow distribution in the meandering channels. The velocity distribution of the primary flow for all cases skewed toward the inner bank at the first bend, and was almost symmetric at the crossovers, and then shifted toward the inner bank again at the next alternating bend. Thus, one can clearly notice that the maximum velocity occurs taking the shortest course along the channel, irrespective of the flow conditions. The result of the tracer tests shows that pollutant clouds are spreading following the maximum velocity lines in each cases with various mixing patterns like superposition, separation, and stagnation of pollutant clouds. Flow characteristics in each cases performed in this study can be compared with tracer dispersion characteristics with using evaluation of longitudinal and transverse dispersion coefficients(LDC, TDC). As expected, LDC and TDC in meandering parts have been evaluated with increasing distribution and straight parts have effected to evaluate minimum of LDC and TDC due to symmetric flow patterns and attenuations of secondary flow.

  • PDF

공동주택 지하주차장의 풍력환기 성능에 관한 연구 - 환기구 면적 및 주변건물의 영향 - (A Study on Ventilation Performance driven by Wind Force in Underground Parking Lots of Apartment - Influence of Opening Size and Surrounding Building -)

  • 노지웅
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.29-34
    • /
    • 2012
  • As a series of studies about natural ventilation driven by wind in basement parking lots of apartment, the influence of opening size and surrounding buildings on ventilation rate was analyzed. Natural ventilation in underground parking lots almost rely on wind than temperature difference. To investigate natural ventilation driven by wind, wind tunnel tests by using scale model and tracer gas method were conducted. $CO_2$-gas concentration was measured, natural ventilation rates were calculated. The experimental results showed that the natural ventilation rate is more reliable to wind direction and surrounding building than opening size and distance between buildings. It was verified that surrounding buildings play a principal role in increasing air flow rate by accelerating wind speed, and growing turbulence intensity. And it showed that ventilation performance is able to be increased by oblique wind to entrance ramp than head on wind in underground parking lots with surrounding buildings.

공장창호의 환기특성에 관한 연구 (A Study on Ventilation Characteristics of Industrial Windows)

  • 박승욱;김태형;하현철;허영빈
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.581-587
    • /
    • 2011
  • Industrial natural ventilation systems consist of gravity ventilator, the high/low windows and doors. Especially, the high windows play an important role in the industrial natural ventilation systems. Generally speaking, industrial high windows are divided into 3 types; louver type, $45^{\circ}$ open type and $90^{\circ}$ open type. This study was numerically and experimentally conducted. Three types of windows were tested to know the ventilation characteristics and estimate the ventilation efficiencies. Numerically, computational fluid dynamics software (AIR PAK Ver. 2.0) was used to observe the flow characteristics inside the industrial building and the concentration contours generated by the tracer gas method. Experimentally, the flow visualization technique and the tracer gas method were applied with the model building to characterize the flow pattern inside the model building and to estimate the ventilation efficiencies with the different windows. It was found that $90^{\circ}$ open type window was most effective for the discharge of pollutants from the industrial building. On the other hand, the louver type window was found to be less effective than any other windows.

Modelling the dispersion of a tracer gas in the wake of an isolated low-rise building

  • Quinn, A.D.;Wilson, M.;Reynolds, A.M.;Couling, S.B.;Hoxey, R.P.
    • Wind and Structures
    • /
    • 제4권1호
    • /
    • pp.31-44
    • /
    • 2001
  • Mean concentrations of ammonia gas released as a tracer from an isolated low-rise building have been measured and predicted. Predictions were calculated using computational fluid dynamics (CFD) and two dispersion models: a diffusion model and a Lagrangian particle tracking technique. Explicit account was taken of the natural variation of wind direction by a technique based on the weighted summation of individual steady state wind direction results according to the probability density function of the wind direction. The results indicated that at distances >3 building heights downstream the weighted predictions from either model are satisfactory but that in the near wake the diffusion model is less successful. Weighted solutions give significantly improved predictions over unweighted results. Lack of plume spread is identified as the main cause of inaccuracies in predictions and this is linked to inadequate resolution of flow features and mixing in the CFD model. Further work on non-steady state simulation of wake flows for dispersion studies is recommended.

라돈 추적자를 이용한 유류오염에 대한 연구 (Investigation on the petroleum contamination by using Rn-222 tracer)

  • 윤윤열;고동찬;이길용;조수영;고경석
    • 분석과학
    • /
    • 제25권1호
    • /
    • pp.14-18
    • /
    • 2012
  • 신속한 유류오염 조사를 위해 자연 방사성 동위원소인 Rn-222를 추적자로 활용하였다. 디젤유로 오염된 화강암 토양시료중의 Rn-222를 액체섬광계수기를 사용하여 분석한 결과 라돈 농도는 유류의 함량에 비례하여 감소하였으며 13%까지 오염시킨 경우 Rn-222의 함량은 30% 까지 감소하였다. TCE로 오염된 지하수의 오염범위를 알기위해 Rn-222를 물과 유류간의 분배계수차이를 활용한 추적자로 사용하였다. 원주의TCE 오염 지하수에 대한 오염범위를 예측하기 위해 Rn-222 분석을 수행하였다.

추적자시험에 의한 폐기물매립장 침출수 누출조사 (Investigation of Leachate Leakage in Waste Landfill by Tracer Test)

  • 이광열;이영준;장삼식
    • 한국지반공학회논문집
    • /
    • 제20권4호
    • /
    • pp.49-56
    • /
    • 2004
  • 본 연구에서는 추적자시험을 이용하여 매립종료된 폐기물매립장에서 꿰뚫림하중에 의해 파손된 차수재를 통한 침출수의 누출 여부를 조사하였다. 추적자시험은 자연구배형식을 채택하였으며, 추적자로는 iodide and Rhodamine WT를 사용하였다. 이 두 추적자는 침출수의 화학적 성분과 반응성을 충분히 고려하여 선정하였다 시험에서는 매립장 전체를 통하여 5개의 주입정과 14개의 관측공을 설치하여 운영하였다. 본 연구의 결과에 의하면, Iodide and Rhodamine WT 추적자는 매립장 침출수 누출조사에 적용 가능하며 효과적임을 확인하였으며, 다량의 침출수가 우수 관로와 우수관로의 외측 벽면을 통하여 누출되었던 것으로 추정된다.

추적가스법을 적용한 국내 석회석 광산의 환기성능 평가 연구 (Ventilation Efficiency Evaluation of Domestic Limestone Mine Using Tracer Gas Method)

  • 김영수;노장훈;김진
    • 터널과지하공간
    • /
    • 제26권4호
    • /
    • pp.274-282
    • /
    • 2016
  • 현재 국내에서 가행 중인 석회석 광산은 자연환기력을 주된 환기방법으로 사용하고 있고, 대단면 굴착으로 매우 저속의 공기유동현상이 나타나고 있다. 이로 인하여 작업구간의 공기질이 매우 저하되어 있는 실정이다. 이러한 문제점들을 개선하기 위해서는 먼저 환기성능을 면밀하게 평가할 필요가 있다. 본 연구에서는 이러한 환기성능평가를 위해서 추적가스법을 적용하여 평가를 실시하였다. 연구 결과, 추적가스법을 통해 매우 저속의 공기유동, 공기재순환현상, 작업장 공기교환율 등을 정량적으로 평가함에 따라서 연구광산의 환기문제점들을 정밀하게 확인할 수 있었다. 이러한 추적가스법을 활용한 환기성능 평가방법은 광산의 작업환경 개선을 위하여 매우 정밀한 도구로 사용될 수 있음을 확인하였다.

부산시 좌천동 단열암반층에서 자연구배 추적자시험을 이용한 수리분산특성 연구 (Characteristics of Hydrodynamic Dispersion Using a Natural Gradient Tracer Test in a Fractured Rock at the Jwacheon-dong, Busan City)

  • 정상용;강동환;김병우
    • 지질공학
    • /
    • 제16권3호
    • /
    • pp.245-254
    • /
    • 2006
  • 부산시 좌천동의 단열암반층에서 자연구배 추적자시험으로 브롬이온농도를 관측하여 심도별 단열발달 상태에 따른 수리분산특성을 비교하였으며, 단열암반층의 유효공극율과 종분산지수를 추정하였다. 수직적인 수리분산특성의 차이는 브롬이온의 농도이력곡선, 관측심도별 브롬이온농도와 시간에 대한 선형회귀분석 및 관측지점별 수리단열특성을 이용하여 규명되었다. 관측공 내 지표면하 18 m(RQD 13%, 평균절리간격 2 cm, TCR 100%) 지점이 주입지점에서의 이격거리가 짧고 단열이 더욱 발달되어 있었기 때문에 25 m(RQD 41%, 평균절리간격 7 cm, TCR 100%) 지점보다 추적자가 빨리 도달하였으며, 초기농도와 최고농도가 더 높게 나타났다. 최고농도도달 전후의 농도변화에 의하면 추적자가 최고농도도달시까지는 주로 1차 단열을 통해 이송되었고, 최고농도도달 이후에는 2차 단열을 통해 이송되거나 기질확산에 의한 수리 분산이 진행되었다. 선형회귀분석에 의한 지표면하 18 m 지점에서 브롬이온농도의 증가/감소 기울기는 3.46/-1.57이며 지표면하 25 m 지점에서는 3.19/-0.47로서 파쇄가 더 심한 지표면하 18 m 지점에서의 용질이송이 빠르게 진행됨을 알 수 있었다. 농도이력곡선에서 브롬이온의 농도증가 형태는 가우시안함수로 나타나고, 농도감소 형태는 기질확산에 의한 꼬리효과(tailing effect)로 인해 지수함수로 나타났다. CATTI 코드를 이용하여 추정한 단열암반층의 유효공극율은 10.5%, 종분산지수는 0.85 m이었다.