• Title/Summary/Keyword: natural frequencies

Search Result 2,582, Processing Time 0.026 seconds

Laboratory Validation of Bridge Finite Model Updating Approach By Static Load Input/Deflection Output Measurements (정적하중입력/변위출력관계를 이용한 단경간 교량의 유한요소모델개선기법: 실내실험검증)

  • Kim, Sehoon;Koo, Ki Young;Lee, Jong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.10-17
    • /
    • 2016
  • This paper presents a laboratory validation of a new approach for Finite Element Model Updating(FEMU) on short-span bridges by combining ambient vibration measurements with static load input-deflection output measurements. The conventional FEMU approach based on modal parameters requires the assumption on the system mass matrix for the eigen-value analysis. The proposed approach doesn't require the assumption and even provides a way to update the mass matrix. The proposed approach consists of two steps: 1) updating the stiffness matrix using the static input-deflection output measurements, and 2) updating the mass matrix using a few lower natural frequencies. For a validation of the proposed approach, Young's modulus of the laboratory model was updated by the proposed approach and compared with the value obtained from strain-stress tests in a Universal Testing Machine. Result of the conventional FEMU was also compared with the result of the proposed approach. It was found that proposed approach successfully estimated the Young's modulus and the mass density reasonably while the conventional FEMU showed a large error when used with higher-modes. In addition, the FE modeling error was discussed.

The effect of hypersonic wave sound for EEG (초음파가 뇌파에 미치는 영향)

  • Jang, Seok Woo;Park, In Gil;Kim, Dae Kyeum;Choi, Hyun
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.101-110
    • /
    • 2014
  • High-frequency is sound produced in non-audible area, which couldn't be heard in daily life. The frequency range above 22Khz is called 'high-frequency' and its components are called 'HFC(High-Frequency Components)'. It is known that ocean wave sound is rich in HFC, because it brings serenity and causes ${\alpha}$-waves in human mind. When this natural sound is combined with high-frequency, it seems to give a pleasurable feeling, indicated by an ${\alpha}$-wave increase and a ${\beta}$-wave decrease. We call this phenomena "the hypersonic effects". In this experiment, subjects listened to the ocean wave sound simultaneously with corresponding frequencies similar to ocean wave frequency components created artificially in a electric circuit. Brain waves were measured by an EEG system with 8 channels using 8 electrodes on Fp1, Fp2, F3, F4, T3, T4, O1, and O2. The results showed that ${\alpha}$-wave increase and ${\beta}$-wave decrease were statistically significant while subjects were listening to the ocean wave sound along with the high frequency components, reflecting the hypersonic effect.

Lightweight Design of a Vertical Articulated Robot Using Topology Optimization (위상최적화를 이용한 수직 다관절 로봇의 경량 설계)

  • Hong, Seong Ki;Hong, Jung Ki;Kim, Tae Hyun;Park, Jin Kyun;Kim, Sang Hyun;Jang, Gang-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1683-1688
    • /
    • 2012
  • Topology optimization is applied for the lightweight design of three main parts of a vertical articulated robot: a base frame, a lower and a upper frame. Design domains for optimization are set as large solid regions that completely embrace the original parts, which are discretized by using three-dimensional solid elements. Design variables are parameterized one-to-one to the material properties of each element by using the SIMP method. The objective of optimization is set as the multi-objective form combining the natural frequencies and mean compliances of a structure for which load steps of interest are selected from the multibody dynamics analysis of a robot. The obtained results of topology optimization are post-processed to designs favorable to manufacturability for casting process. The final optimized results are 11.0% (base frame), 12.0% (lower frame) and 10.0% (upper frame) lighter with similar or even higher static and dynamic stiffnesses than the original models.

Vibration and Dynamic Sensitivity Analysis of a Timoshenko Beam-Column with Ends Elastically Restrained and Intermediate Constraints (중간구속조건을 갖는 양단탄성구속 Timoshenko 보-기동의 진동 및 동특성감도 해석)

  • J.H. Chung;W.H. Joo;K.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.1
    • /
    • pp.125-133
    • /
    • 1993
  • Most studies on the vibration analysis of a beam-column with ends elastically restrained and various intermediate constraints have been based on the Euler beam theory, which is inadequate for beam-columns of low slenderness ratios. In this paper, analytical methods for vibration and dynamic sensitivity of a Timoshenko beam-column with ends elastically restrained and various intermediate constraints are presented. Firstly, an exact solution method is shown. Since the exact method requires considerable computational effort, a Rayleigh-Ritz analysis is also investigated. In the latter two kinds of trial functions are examined for comparisions : eigenfunctions of the base system(the system without intermediate constraints) and polynomials having properties corresponding to the eigenfunctions of the base system. The results of some numerical Investigations show that the Rayleigh-Ritz analysis using the characteristic polynomials is competitive with the exact solutions in accuracy, and that it is much more efficient in computations than using the eigenfunctions of the base system, especially in the dynamic sensitivity analysis. In addition, the prediction of the changes of natural frequencies due to the changes of design variables based on the first order sensitivity is in good agreements with that by the ordinary reanalysis as long as the changes of design variables are moderate.

  • PDF

Novel influenza A (H1N1) 2009 infection in the pediatric patients with hematologic and oncologic diseases in the Yeungnam region in Korea

  • Kang, Seok-Jeong;Lee, Jae-Min;Hah, Jeong-Ok;Shim, Ye-Jee;Lee, Kun-Soo;Shin, Hyun-Jung;Kim, Heung-Sik;Choi, Eun-Jin;Jeon, So-Eun;Lim, Young-Tak;Park, Ji-Kyeong;Park, Eun-Sil
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.3
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: Natural history and consequences of the novel 2009 influenza A H1N1(2009 H1N1) infection in immunocompromised pediatric patients are not yet fully understood. In this study, we investigated the clinical features and outcomes of the 2009 H1N1 infection in pediatric patients with hematological and oncological diseases. Methods: We retrospectively reviewed the medical records of 528 patients who had hematological and oncological diseases and who were treated at 7 referral centers located in the Yeungnam region. Among the 528 patients, 27 with definite diagnosis of 2009 H1N1 infection were the subjects of this study. All patients were divided into the following 3 groups: patients who were receiving chemotherapy (group 1), patients who were immunosuppressed due to a nonmalignant hematological disease (group 2), and patients who were off chemotherapy and had undergone their last chemotherapy course within 2 years from the influenza A pandemic (group 3). Results: All 28 episodes of 2009 H1N1 infection were treated with the antiviral agent oseltamivir ($Tamiflu^{(R)}$), and 20 episodes were treated after hospitalization. Group 1 patients had higher frequencies of lower respiratory tract infection and longer durations of fever and hospitalization as compared to those in group 2. Ultimately, all episodes resolved completely with no complications. Conclusion: These results suggest that early antiviral therapy did not influence the morbidity or mortality of pediatric patients with hematological and oncological diseases in the Yeungnam region of Korea after the 2009 H1N1 infection. However, no definite conclusions can be drawn because of the small sample size.

Effective Range Evaluation of Wireless Monitoring System for Monopile (모노파일용 원거리 무선 모니터링 시스템의 유효거리 평가)

  • Park, Kiwon;Lee, Jong-Sub;Choi, Changho;Byun, Yong-Hoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.6
    • /
    • pp.91-100
    • /
    • 2012
  • Wireless monitoring system for the structural health evaluation has a limit to the reliability of measured response. The objective of this study is to evaluate an effective measurement range of the wireless monitoring system on the analyzed data. For the wireless monitoring system, Bluetooth and Wi-Fi are applied to datalogger-receiver and receiver-personal computer, respectively. For the model of the monopile structure response, a laboratory-scale monopile is manufactured with Mono Cast Nylon and a lateral loading is applied by hammer impacting. Strain gauges attached on the model monopile are connected with the datalogger. The distances of datalogger-receiver and receiver-personal computer are changed for the evaluation of the measurement range. Experimental results show that the receiving rates of the response remain almost constant within limited distance, while the receiving rates dramatically decrease out of effective range. In addition, the receiving rates affect on the measured natural frequencies of the model monopile. This study suggests that the effective range evaluation of the wireless monitoring system may be used for the determination of a monitoring distance to the monopile installed in the offshore wind farm.

Clinical Finding of MDR Tuberculosis and Frequency of MOTT (다제내성결핵의 임상적 특성과 비결핵항산균증의 빈도)

  • Bae, Mi-Hee;Kim, Hwa-Jung;Kwon, Eun-Soo;Kim, Cheol-Min;Kim, Cheon-Tae;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1123-1142
    • /
    • 1998
  • Background : The frequency of MOTT has risen as the prevalence of tuberculosis has been declining. Our country has been also. The most of MOTT was resistant to the major anti-tuberculous drugs. Method : To compare clinical characteristics and frequencies of MDR tuberculosis with MOTT, the author studied 65 patients showing AFB culture positive with sputum. The data were collected from 176 patients who had been admitted at the National Masan Tuberculosis Hospital from May to June, 1997 to April, 1998. Result : The frequency of MDR tuberculosis was 43.1% and that of MOTT was 9.2%. Among 65 isolated mycobacteria, 3 cases were M. intracellulare. 2 cases were M. fortuitum, and 1 case was unidentified MOTT. The most frequent age group in 65 culture positive patients was 4th decade and the mean age was 44. The mean age was 61 in MOTT and 42 in M. tuberculosis and had significant difference(p<0.01). The numbers with past history of treatment were 2.3 in MDR tuberculosis and 1.7 in non-MDR tuberculosis and had significant difference(p<0.05). At the time of admission, the most frequent regimen for the treatment of MDR tuberculosis was 24 months regimen(85.7%) with the 2nd line anti-tuberculosis drugs. For non-MDR tuberculosis, 9 or 12 months regimen (72.9%) with the 1st line anti-tuberculosis drugs and had significant difference (p<0.01). At the time of admission, the symptom of weight loss was shown in 84.7% of M. tuberculosis and 50.0% in MOTT and there was significant difference(p<0.05) between them. All of the MOTT were identified to be resistant against INH and PAS. Drug resistance rates to INH, OFX(p<0.01) and PAS(p<0.05) in MOTT were higher than in MDR. All of three M. intracellulare strains were resistant to INH, RFP, PAS and OFX. All of two M. fortuitum strains were resistant to most anti-tuberculosis drugs. And the other MOTT was resistant to INH, EMB and PAS. Conclusion : MOTT was more common in elderly patients than M. tuberculosis. MOTT cases should be considered to be the probability of multiple drug resistance and treatment failure during the 1st treatment because they showed more resistance to anti-tuberculosis drugs than M. tuberculosis cases. Therefore, there should be more careful investigations for clinical characteristics, natural history of disease, and efficient management for MOTT.

  • PDF

Measurement System of Dynamic Liquid Motion using a Laser Doppler Vibrometer and Galvanometer Scanner (액체거동의 비접촉 다점측정을 위한 레이저진동계와 갈바노미터스캐너 계측시스템)

  • Kim, Junhee;Shin, Yoon-Soo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.227-234
    • /
    • 2018
  • Researches regarding measurement and control of the dynamic behavior of liquid such as sloshing have been actively on undertaken in various engineering fields. Liquid vibration is being measured in the study of tuned liquid dampers(TLDs), which attenuates wind motion of buildings even in building structures. To overcome the limitations of existing wave height measurement sensors, a method of measuring liquid vibration in a TLD using a laser Doppler vibrometer(LDV) and galvanometer scanner is proposed in this paper: the principle of measuring speed and displacement is discussed; a system of multi-point measurement with a single point of LDV according to the operating principles of the galvanometer scanner is established. 4-point liquid vibration on the TLD is measured, and the time domain data of each point is compared with the conventional video sensing data. It was confirmed that the waveform is transformed into the traveling wave and the standing wave. In addition, the data with measurement delay are cross-correlated to perform singular value decomposition. The natural frequencies and mode shapes are compared using theoretical and video sensing results.

Characteristics of Low-frequency Ambient Seismic Noise in South Korea (국내 저주파수 무작위 지진잡음의 특성 연구)

  • Park, Iseul;Kim, Ki Young;Byu, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.67-75
    • /
    • 2016
  • To investigate spatial and temporal variations of low-frequency (${\leq}5Hz$) ambient seismic noise, we analyzed the noise data recorded for one whole year of 2014 at surface accelerometer stations in South Korea. After decomposed into low-frequency (LF; < 1 Hz) and high-frequency (HF; ${\geq}1Hz$) components, the root-mean-squared (RMS) amplitudes and power spectral densities (PSD) of the noise data were computed. The RMS amplitudes were larger on islands and near-shore stations, but also large RMS amplitudes were observed at inland stations in large cities only for HF components. The RMS amplitudes of HF components were larger in the daytime than at nighttime and during weekdays than on Sunday and holidays. This indicates the HF components are closely related to human activities. On the contrary, daily and weekly variations were not clear in the LF components while they showed seasonal variations with its maximum during the winter and a good correlation with significant wave height. Therefore, we interpret the mechanism of LF components is closely related to natural phenomena such as sea. The amplitude of LF components decreased as an exponential function of the distance to the center of typhoons. The exponential index of -0.76 suggested that ambient seismic noise included both surface and body waves. Peak frequencies of the PSD curves were near 0.34 Hz indicating the double frequency. No temporal variation in the peak frequency was clearly noticed.

Development of a New Lumped-Mass Stick Model using the Eigen-Properties of Structures (구조물의 동적 고유특성을 이용한 새로운 집중질량모델 개발)

  • Roh, Hwa-Sung;Youn, Ji-Man;Lee, Hu-Seok;Lee, Jong-Seh
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.19-26
    • /
    • 2012
  • For a seismic design or performance evaluation of a structure, an experimental investigation on a scale model of the structure or numerical analysis based on the finite element model is considered. Regarding the numerical analysis, a three-dimensional finite element analysis is performed if a high accuracy of the results is required, while a sensitivity or fragility analysis which uses huge seismic ground motions leads to the use of a lumped-mass stick model. The conventional modeling technique to build the lumped-mass stick model calculates the amount of the lumped mass by considering the geometric shape of the structure, like a tributary area. However, the eigenvalues of the conventional model obtained through such a calculation are normally not the same as those of the actual structure. In order to overcome such a deficiency, in this study, a new lumped mass stick model is proposed. The model is named the "frequency adaptive-lumped-mass stick model." It provides the same eigenvalues and similar dynamic responses as the actual structure. A non-prismatic column is considered as an example, and its natural frequencies as well as the dynamic performance of the new lumped model are compared to those of the full-finite element model. To investigate the damping effect on the new model, 1% to 5% of the critical damping ratio is applied to the model and the corresponding results are also compared to those of the finite element model.