Performance Characteristics of a Liquid-Metal Heat Pipe for igh-temperature Solar Thermal Devices Depending on the Operating Conditions (고온 태양열기기용 액체금속 히트파이프의 작동조건에 따른 성능 특성)

  • Park, Cheol-Min;Lee, Jung-Ryun;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.247-250
    • /
    • 2009
  • Sodium heat pipe for high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Total length of the heat pipe was 650 mm and the outer diameter was 12.7 mm. Thermal performance was compared experimentally for two different cooling methods of the forced and the natural convection cooling in the heat pipe condenser. During the experiment, the maximum temperature was about 1300K, and different cooling methods were applied to the condenser region to charge the operating temperature. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and operating temperature.

  • PDF

THERMO-MECHANICAL ANALYSIS OF OPTICALLY ACCESSIBLE QUARTZ CYLINDER UNDER FIRED ENGINE OPERATION

  • Lee, K.S.;Assanis, D.N.
    • International Journal of Automotive Technology
    • /
    • v.1 no.2
    • /
    • pp.79-87
    • /
    • 2000
  • Analytical approach was followed in this work under both the steady state and transient operating conditions to find optimum boundary conditions, where the optically accessible quartz engine can run safely without breaking. Temperature and stress distribution was predicted by FEM analysis. In order to validate thermal boundary condition, model reliability and constraint, outside cylinder temperature was measured and previous study was also followed up numerically. To reduce thermal stress level, three types of outside cooling (natural, moderate forced and intensive forced convection) were considered. Effects of clamping force and combustion pressure were conducted to investigate mechanical stress level. Cylinder thickness, was changed to fine the optimum cylinder thickness. The versatile results achieved from this work can be basic indication, which is capable of causing a sudden quartz cylinder breaking during fired operation.

  • PDF

Ionic Wind Generator With Third Electrode (3전극형 이온풍 발생장치)

  • Hwang, Deok-Hyun;Jung, Hoi-Won;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.139-140
    • /
    • 2008
  • Cooling systems for electronic equipments are becoming more important. Cooling technologies using natural and forced convection are limited and operated in very low efficiency. A corona discharge is utilized as the driving mechanism for anair pump, which allows for airflow generation with low noise and no moving parts. However they do not enhance the flow rate and overcome the control mechanism of the pump. In this study a point-mesh type air pump, with a third electro de installed near the corona point, has been proposed and investigated by focusing on elevating the ionic wind velocity and power yield. As a result, the significantly enhanced ionic wind velocity and tremendously increased power yield can be obtained with the proposed air pump system.

  • PDF

Numerical Analysis of Heat Transfer of a Printed Circuit Boards for Safety Design of Electronic Equipment at Each Design Stage (전자장비 안전설계를 위한 PCB의 설계단계별 열전달 해석)

  • 김재홍;김종일
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.22-29
    • /
    • 1998
  • The natural convection cooling of simulated electronic chips located on a printed circuit board(PCB) has been studied by Computer Aided Engineering(CAE). In CAE, 3-dimensional finite element model of simulated electronic chip was made to accomplish heat transfer analysis at each design stage of a printed circuit boards for thermal optimization. The simulated electronic chips are installed protrudent from the plate about 3mm. The materials the plates are epoxy and aluminum. The results show that the chip with relatively high heat generation rates should not be close to each other. It is found, as well that cooling effect for the aluminum plate is superior to the epoxy plate and location of maximum temperature is significantly influenced by the structure variation of PCB. In developing PCB and electronic chips, it's recommended that CAE is very useful to estimate to the distribution of temperature.

  • PDF

Transient heat transfer analysis of functionally graded CNT reinforced cylinders with various boundary conditions

  • Moradi-Dastjerdi, Rasool;Payganeh, Gholamhassan
    • Steel and Composite Structures
    • /
    • v.24 no.3
    • /
    • pp.359-367
    • /
    • 2017
  • In this work, transient heat transfer analysis of functionally graded (FG) carbon nanotube reinforced nanocomposite (CNTRC) cylinders with various essential and natural boundary conditions is investigated by a mesh-free method. The cylinders are subjected to thermal flux, convection environments and constant temperature faces. The material properties of the nanocomposite are estimated by an extended micro mechanical model in volume fraction form. The distribution of carbon nanotube (CNT) has a linear variation along the radial direction of axisymmetric cylinder. In the mesh-free analysis, moving least squares shape functions are used for approximation of temperature field in the weak form of heat transform equation and the transformation method is used for the imposition of essential boundary conditions. Newmark method is applied for solution time depended problem. The effects of CNT distribution pattern and volume fraction, cylinder thickness and boundary conditions are investigated on the transient temperature field of the nanocomposite cylinders.

Improvement of Case Design for Underground Power Distribution Facilities (지중배전기기용 외함 디자인 개선)

  • Jeong, Yeon-Ha;Park, Chul-Bae;Chun, Sung-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.362-365
    • /
    • 2007
  • In this paper we present development process and results of some cases for underground pad transformer and switchgear. Some characteristic factors was considered and tested to improve the functions of the case, such as natural convection of cooling air between the internal and external cases, properties of material that used as external panel etc. Proposed designs and functional characteristics will be adapted to making the cases of underground facilities after the elaborated tests. The results obtained from this study will improve the scenery of a street.

  • PDF

Simulation of buoyant turbulent flow in a stairwell (건물 계단통에서의 부력에 의한 난류유동 해석)

  • 명현국;진은주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.217-226
    • /
    • 1998
  • A numerical study has been carried out for two- and three-dimensional buoyant turbulent flow in a stairwell model. The Reynolds-averaged Navier-Stokes and energy equations are solved with the authors'own computer program. Two models by the Boussinesq approximation and the density-gradient form are used for buoyancy terms in the governing equations. Two- and three-dimensional predictions of the velocity and temperature fields are presented and the results are compared with experimental data. Comparisons have also been made in detail with two-dimensional predictions. Two-dimensional and three-dimensional simulations have predicted the overall features of the flow satisfactorily. A better agreement with experiment is achieved with three-dimensional simulations.

  • PDF

PCCS Analysis Model for the Passively Cooled Steel Containment

  • Hwang, Y.D.;Chung, B.D.;Cho, B.H.;Chang, M.H.;Jeong, Ik
    • Nuclear Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.26-39
    • /
    • 1998
  • The containment pressure and temperature transient analysis computer code CONTEMPT4/MOD5 is modified to incorporate the passive containment cooling models. The correlations are selected from the existing experimental heat transfer correlations to model the natural and mixed convection in annular space between the containment shell and the shield building. The evaporative heat transfer of the water film on the outer shell of the containment is modeled using the correlations derived from the analogy between the heat and mass transfer. The modified code is applied to the Ap600 containment transient analysis for the model verification and the results are compared to the results of GOTHIC calculation done by Westinghouse. Also, d series of parametric sensitivity studies of heat transfer correlations, water film ratio and delay time of the wet cooling on the containment peak pressure and temperature following LOCA are performed for the containment of 1000MWe passive plant, KP1000.

  • PDF

APPLICATIONS OF ELECTROPLATING METHOD FOR HEAT TRANSFER STUDIES USING ANALOGY CONCEPT

  • Ko, Sang-Hyuk;Moon, Deok-Won;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.251-258
    • /
    • 2006
  • This study presents an idea of using analogy concept to the heat transfer studies regarding the HTGR development. Theoretical backgrounds regarding the idea were reviewed. In order to investigate the predictability of a mass transfer system for heat transfer system phenomenology, an electroplating system coupled with a limiting current technique was adopted. Test facilities for laminar forced convection and natural convections under laminar and turbulent conditions were constructed, for which heat transfer correlations are known. The test results showed a close agreement between mass transfer and heat transfer systems, which is an encouraging indication of the validity of the analogy theory and the experimental methodology adopted. This paper shows the potential of the experimental method that validates the little-understood heat transfer phenomena, even in complex geometries such as HTGR.

Effects of Natural Convection Instability on Membrane Fouling Control in Ultrafiltration (한외여과에서 자연대류 불안정성의 막오염 제어 효과)

  • 김태곤;염경호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.101-104
    • /
    • 1997
  • 1. 서론 : 한외여과(ultrafiltration; UF)는 장치 및 조작이 간단하고, 열의 사용없이 물질을 분리 정제를 할 수 있기 때문에 생물제품 등을 비롯한 거대분자들의 분리에 널리 활용되고 있다. 그러나 한외여과 공정의 운전시 가장 큰 문제점은 막에 의해 분리된 물질들이 필연적으로 막표면에 가역적으로 누적되는 농도분극(concentration polarization)과 이 누적된 물질이 막과의 상호작용에 의해 막표면에 비가역적으로 침적되는 막오염(membrane fouling)현상을 유발시킨다는 것이다. 일반적으로 한외여과는 막세공과 분리 대상물의 크기차에 의한 sieve effect에 의해 분리가 이루어지는데 막오염이 발생되면 세공의 일부 또는 전체가 막히게 되어 결국에는 투과선속(permeate flux)이 감소하고, 막의 세공분포가 달라져 막 본래의 분리성능에 변화가 초래된다.(생략)