대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구 (Numerical study for performance analysis and design of a counterflow type cooling tower)

  • 이상윤;이정희;최영기;유홍선
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

온돌의 연탄개스유량에 관한 연구(1) (함습저온열기류의 굴뚝통풍력) (Study on the Flow of Briquette Gas in the Ondol Heating System (Chimney Draft of Low Temperature Moist Air))

  • 민만기
    • 대한설비공학회지:설비저널
    • /
    • 제4권2호
    • /
    • pp.119-128
    • /
    • 1975
  • Natural draft and flow which low temperature moist gas produces in the chimney of an Ondol heating system were numerically analysed. Among several factors involved inlet gas temperature has the strongest influence on the chimney performance and then next specific humidity of the gas. Thermal conductivity of the chimney wall, however, has little influence on the performance of such a low temperature chimney. Under given flow conditions there exists an optimum chimney height which gives a maximum flow rate for a given chimney diameter. This optimum value of chimney height inereases with increase in chimney diameter, inlet gas temperature and specific humidity.

  • PDF

수동형 격납용기 냉각계통에서의 열전달 (Heat Transfer in the Passive Containment Cooling System)

  • Cha, Jong-Hee;Jun, Hyung-Gil;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.281-291
    • /
    • 1995
  • 이 연구의 목적은 수동형 격납용기 냉각계통의 용기 바깥표면이 건조 및 습한 조건일때 격납용기 내, 외벽에서 일어나는 열전달과정에 대한 실험적 자료를 얻는데 있다. 시험모델은 AP 600구조에 근거하여 격납용기의 둘레중 60$^{\circ}$부분만을 취하였다. 시험모델의 주요치수는 원형의 값을 대략 10분의 1로 축소한 것이다. 붕괴열을 모의하기 위하여 전기적으로 가열되는 증기발생기를 시험모델내에 설치하였다. 최대열유속은 8.91 kW/$m^2$ 이었다. 두 가지 형식의 시험이 수행되었다. 하나는 수막유동없이 공기만의 자연대류에 관한 시험이고 다른 하나는 수막유동과 공기의 자연대류가 동반된 증발열전달 시험이다. 시험결과 수막유동이 없는 경우 공기만의 자연대류 열전달 능력은 약 1.48 kW/$m^2$ 열유속에서 제한되고 있음을 알게 되었다 또한 수막유동과 공기의 자연대류가 동시에 일어나는 시험에서 열제거 능력은 현저히 향상됨을 알게 되었다 이들 열전달 측정치들을 기존 관계식들과 비교하였다.

  • PDF

FGR 시스템 공력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향 (Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in Power Plant Boilers with FGR System)

  • 배명환;정광호;최승철;조용수;김이석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1686-1691
    • /
    • 2004
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air(OFA) damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_{x}$ emissions. To activate the combustion, the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$ , and the OFA with 0 to 20% into the flame is supplied, as the combustion air supplied to burner is reduced. It is found that the fuel consumption rate divided by evaporation rate does not show an obvious tendency to increase or decrease with rising the FOR rate, and $NO_{x}$ emissions are decreased, at the same OF A damper opening, as FOR rates are elevated and boiler loads are dropped.

  • PDF

오염하천 정화를 위한 호기성 인공습지의 운영인자 평가 (Parameter Estimation of the Aerated Wetland for the Performance of the Polluted Stream Treatment)

  • 김둘선;이동근
    • 청정기술
    • /
    • 제25권4호
    • /
    • pp.302-310
    • /
    • 2019
  • 호기조와 혐기/무산소조를 직렬로 연결한 인공습지를 이용하여 크게 오염된 하천수를 처리하였다. 호기조는 자연 공기 배출 시스템을 통하여 공기가 연속적으로 공급되어 호기성 상태가 유지되었다. 인공습지의 성능에 영향을 미치는 최적의 영향인자를 조사하기 위하여 체류시간을 다르게 한 5개의 파일럿 플랜트를 사용하였다. 호기조에서 BOD (biochemical oxygen demand)와 COD (chemical oxygen demand)의 제거율은 1차 반응 속도식을 나타내었고, COD 제거 속도 상수는 BOD보다 약간 낮았다. 온도 의존성은 COD (θ = 1.0079)와 BOD (θ = 1.0083)제거에 대한 값이 거의 동일했으나 T-N 제거의 온도 의존성(θN)은 1.0189로 다소 높게 나타났다. SS제거율은 98%로 높았고 수력학적 부하 속도(Q/A)가 증가함에 따라 제거 효율이 증가하는 경향을 보였다. 혐기/무산소조에서 BOD와 COD 제거의 주요 메커니즘은 호기조와 완전히 다르게 나타났다. 혐기/무산소조에서 COD와 COD는 생물학적 탈질을 위한 탄소원으로 공급되었고 T-P는 혐기/무산소조 내의 orthophosphate와 자갈 사이의 양이온 교환에 의해 제거되는 것으로 조사되었다. 인공습지는 여과된 고형물에 의해 막힘 없이 성공적으로 운영되었고 고형물들은 매우 빠르게 연속적으로 분해되었다.

바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구 (Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant)

  • 신재석;김성철;조광주;최충호;최인욱;박정자;박구현
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.115-121
    • /
    • 2009
  • 생물산업 연구단지에서 발생되는 폐수를 처리하기 위해 건설된 폐수처리장의 3차 처리시설로 hybrid 인 공습지 시스템을 적용하여 최종 방류수의 재이용가능성을 평가하였다. 폐수처리를 위한 1차 처리공정은 화학적 처리(약품 응집)이며, 2차 처리공정은 생물학적 처리(표준활성슬러지법)로 구성되어 있다. 3차 처리시설로서 hybrid 인공습지는 자연통풍시스템이 구비된 호기성 인공습지와 혐기/무산소성 인공습지가 순차적으로 연결된 시스템이다. Hybrid 인공습지로 유입되는 2차 생물학적 처리공정의 처리수 농도는 BOD, SS, T-N 및 T-P의 평균 농도가 각각 53mg/L, 48mg/L, 34mg/L 및 3mg/L로 나타났으며, hybrid 인공습지에서의 최종방류수의 BOD, SS, T-N 및 T-P의 평균농도는 각각 2.3mg/L, 1.2mg/L, 7.95mg/L 및 0.83mg/L로 나타나 하수처리수의 재이용권고수질기준과 비교할 때 조경용수나 세척용수 등의 용도로 직접 재이용이 가능한 수질이 확보될 수 있었다. Hybrid 인공습지는 반응조를 호기 및 혐기/무산소 조건으로 기능화 함으로서 높은 효율로 오염물질이 제거될 수 있었으며, 이러한 결과로부터 다양한 하수 및 폐수의 3차 처리시설로서 활용이 가능한 것으로 평가되었다.

  • PDF

FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구 (A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System)

  • 배명환;정광호;박성범
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.263-273
    • /
    • 2016
  • 자연순환식 압입 송풍식 수관보일러에 FGR시스템을 설치하여 보일러 부하 및 공기량 댐퍼개도를 파라미터로 해서 FGR률에 따른 성능 및 배기 배출물에 미치는 재순환 배기의 영향을 조사하였다. 본 연구의 목적은 $NO_x$ 배출물을 저감시키기 위하여 동력플랜트 보일러에 FGR시스템을 적용하는 것이다. 연소를 활성화시키기 위해 0 ~ 20%의 연소용 공기를 화염 내에 공급한다. 공기상자 상부에 설치된 2단 연소시스템의 흡입댐퍼를 $0^{\circ}{\sim}90^{\circ}$ 사이에서 레버를 조작하여 열면, 버너로 공급되는 연소용 공기가 변화된다. 증발률당의 연료소비율은 FGR률의 증가에 따라 증가 혹은 감소의 명확한 경향을 나타내지 않았고, 동일 공기량 댐퍼개도에서는 FGR률이 증가할수록, 또한, 보일러 부하가 감소할수록 $NO_x$ 배출물이 감소되었다. 매연 배출물은 전기 집진기에서 86.7%의 포집효율로 매연이 제거되었기 때문에, 보일러 부하, 공기량 댐퍼 개도 및 FGR률의 운전조건에 관계없이 극소량의 매연이 배출되었다.