• Title/Summary/Keyword: natural / forced convection

Search Result 89, Processing Time 0.02 seconds

Numerical Study on Combined Heat Transfer in NIR Dryer for Agricultural and Marine Products (근적외선 농수산물 건조기의 복합열전달특성에 관한 수치적 연구)

  • Choi, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.395-402
    • /
    • 2006
  • Mixed heat transfer in an indirected NIR (Near Infrared Ray) dry chamber was investigated numerical analysis. It is Important that the miked heat transfer effects on double parameters which the Reynolds number and the position of emit lamp. Reynolds number are based on the outer diameter of the cylinder range from 103 to $30{\times}105$. Four difference heat transfer regimes of behavior are apparent: forced convection and radiation on the outer surface of the cylinder, pure conduction, pure natural convection and radiation between lamp surface and inner surface of the cylinder. The temperature and flow patterns are illustrated by iso-contour lines for the double parameters. Also presented are results on the convective heat transfer flux and the radiative heat transfer flux as increased with Reynolds number.

THERMO-MECHANICAL ANALYSIS OF OPTICALLY ACCESSIBLE QUARTZ CYLINDER UNDER FIRED ENGINE OPERATION

  • Lee, K.S.;Assanis, D.N.
    • International Journal of Automotive Technology
    • /
    • v.1 no.2
    • /
    • pp.79-87
    • /
    • 2000
  • Analytical approach was followed in this work under both the steady state and transient operating conditions to find optimum boundary conditions, where the optically accessible quartz engine can run safely without breaking. Temperature and stress distribution was predicted by FEM analysis. In order to validate thermal boundary condition, model reliability and constraint, outside cylinder temperature was measured and previous study was also followed up numerically. To reduce thermal stress level, three types of outside cooling (natural, moderate forced and intensive forced convection) were considered. Effects of clamping force and combustion pressure were conducted to investigate mechanical stress level. Cylinder thickness, was changed to fine the optimum cylinder thickness. The versatile results achieved from this work can be basic indication, which is capable of causing a sudden quartz cylinder breaking during fired operation.

  • PDF

Characteristics Maintenance Internal Temperature of Apple and Portable Low-Temperature Container by Using Phase Change Materials (잠열재를 이용한 이동식 저온 컨테이너 및 사과의 내부온도 유지특성)

  • Kwon, Ki-Hyun;Kim, Jong-Hoon;Jeong, Jin-Woung
    • Food Science and Preservation
    • /
    • v.15 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • By considering the storage temperatures of agricultural products, three types of PCMs $(K_1$, $K_2$, $K_3$) were developed to be used in temperature ranges of $0{\sim}5^{\circ}C$, $5{\sim}10^{\circ}C$ and $10{\sim}15^{\circ}C$, $K_1$ PCM for $0{\sim}5^{\circ}C$ was developed by mixture of $C_{14}H_{30}$ and soduim polyacrylate, and $K_2$ PCM for $5{\sim}10^{\circ}C$ and $K_3$ PCM for $10{\sim}15^{\circ}C$ were mixture of $C_{14}H_{30}$, $C_{18}H_{38}$ and soduim polyacrylate with different composition ratio. 'The target temperatures of cold chain system were set at $7^{\circ}C$, $13^{\circ}C$, and $17^{\circ}C$ with $K_{1-3}$, $K_{2-3}$ and $K_{3-1}$ PCMs, respectively. The times to reach the target temperatures in the storage chamber were 21 hours, 18 hours, and 61 hours with $K_1$, $K_2$, and $K_3$ PCMs, respectively. The performances of natural convection type and forced convection of the temperature controlled portable container were analyzed Apples were stored in the portable container of $5^{\circ}C$, and temperatures at surface and center were measured. The initial temperature of the apple was $25^{\circ}C$. The temperatures of apple at the surface and the center were $15^{\circ}C$ and $16^{\circ}C$, respectively, after 5 hours with natural convection type. However, the temperatures at the surface and the center were already reached to $7^{\circ}C$ within 1 hour with forced convection type. The forced convection type showed the better performance and the temperatures of portable container were maintained more than 15 hours.

Heat Transfer Characteristics of Coil Tube Heat Exchanger for Hot Water Heating of Greenhouse Thermal Tunnel (보온터널 난방을 위한 온수난방용 코일튜브 열교환기의 열전달 특성)

  • Ryou, Y.S.;Kang, K.C.;Kim, Y.J.;Paek, Y.;Kang, Y.G.;Lee, H.M.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.430-435
    • /
    • 2006
  • Greenhouse horticulture in South Korea covered about 52,000 ha in 2005. Greenhouse area of about 12,000 ha has been heated during winter season with heating cost of $20{\sim}40%$ of total Production cost. Farmers engaged in greenhouse horticulture were changed into aged people. Therefore the laborsaving of working process and the saving of greenhouse heating cost should be accomplished simultaneously to increase income of greenhouse horticulture. The best method for saving of greenhouse heating cost is to install thermal tunnels into greenhouse. Then hot air heaters using fossil fuel should be changed into hot water heaters. In other words air heating using forced convection should be changed into natural convection system. In this research coil tube made of flexible PE pipe was designed as hot water heat exchanger and its heat exchanging characteristics were analyzed. This new heat exchanger has been adopted as a natural convection system for hot water heating of greenhouse horticulture.

Development of Thermal Design Program for an Electronic Telecommunication System Using Heat Sink (히트싱크를 이용한 전자통신 시스템의 방열설계 프로그램 개발)

  • Lee, Jung-Hwan;Kim, Jong-Man;Chun, Ji-Hwan;Bae, Chul-Ho;Suh, Myung-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.256-263
    • /
    • 2007
  • The purpose of this study is to investigate the cooling performance of heat sinks for an electronic telecommunication system by adequate natural convection. Heat generation rates of electronic components and the temperature distributions of heat sinks and surrounding air are analyzed experimentally and numerically. In order to perform the heat transfer analysis for the thermal design of telecommunication system a program is developed. The program used the graphic user interface environment to determine the arrangement of heat sources, interior fan capacity, and heat sink configuration. The simulation results showed that the heat sinks were able to achieve a cooling capacity of up to 230W at the maximum temperature difference of $19^{\circ}C$. To verify the results from the numerical simulation, an experiment was conducted under the same condition as the numerical simulation, and their results were compared. The design program gave good prediction of the effects of various parameters involved in the design of a heat sinks for an electronic telecommunication system.

Prediction of Penetration and Heat Affected Zone by Using Finite Element Method in $CO_2$ Arc Welding (유한 요소법을 이용한 $CO_2$아아크 용접부의 용입깊이와 열영향부 크기 예측)

  • 이정익;박일철;박기영;엄기원
    • Journal of Welding and Joining
    • /
    • v.10 no.4
    • /
    • pp.222-229
    • /
    • 1992
  • A prediction of penetration and heat affected zone by using Finite Element Method in CO$_{2}$ Arc Welding has been discussed this paper. The temperature distribution of a base metal produced by the CO$_{2}$ arc welding processing is analyzed by using a three dimensional finite element model. The common finite element program ANSYS 4.4A was employed to obtain the numerical results. Temperature dependent material properties, effect of latent heat, and the convective boundary conditions are included in the model. Numerically predicted sizes of the penetration and the heat affected zone are compared with the experimentally observed values. As a result, there was a slight difference between numerical analysis values and experimentally observed values. For in the case of heat affected zone, it was not considered a precise forced convective coefficient value, and in the case of penetration, it was not, considered a arc force.

  • PDF

Three-Dimensional Numerical Study on the Vortex Flow in a Horizontal Channels with High Viscous Fluid(2) (수평채널 내 고 점성유체의 볼텍스 유동에 관한 3차원 수치해석(2))

  • Piao, Ri-Long;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.36-42
    • /
    • 2015
  • TMixed convective flow in a bottom heated and top cooled rectangular channel can be significantly affected by the channel aspect ratio, Prandtl number, Reynolds number, Rayleigh number and angle of inclination. In such a mixed convection, the flow pattern plays an important role in various technological processes. In this study, a numerical investigation is carried out to explore mixed convection in a three-dimensional rectangular channel with bottom heated and top cooled uniformly. The three-dimensional governing equations are discretized using the finite volume method. In the range of low Reynolds number($0{\leq}Re{\leq}9.6{\times}10^{-2}$), the effects of the aspect ratio($2{\leq}AR{\leq}12$) and Gr/Re are presented and discussed. The longitudinal roll number in the channel is increased with increasing aspect ratio, and the roll number induced, regardless of the aspect ratio number, is even in the range of aspect ratios between 2 and 12, New vortex flow structure containing inclined longitudinal rolls is found, which is affected by aspect ratio and Reynolds number. The ratio Gr/Re is used to check the relative magnitudes of forced and natural convection in the mixed convective flow of high viscous fluid.

Analysis on the Cooling Characteristics of the Swindle with High Frequency Motor (고주파 모터 내장형 주축의 냉각특성 해석)

  • 김수태;창원대;최대봉
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.278-283
    • /
    • 2002
  • Cooling characteristics for the three type spindles with high frequency motor are studied. For the analysis, three dimensional models are built considering heat transfer characteristics such as natural and forced convection coefficients. Unsteady-state temperature distributions and thermal deformations according to the cooling conditions are analyzed by using the finite element method.

  • PDF

A Study on the Thermal Characteristics of the Spindle System with Built-in Motor according to Spindle type (모터내장형 주축계의 구조에 따른 열특성 해석에 관한 연구)

  • 서창범;김수태;최대봉
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.105-110
    • /
    • 2001
  • Unsteady-state temperature distributions for spindle system with built-in motor according to spindle type are studied. For the analysis, three dimensional model is built considering heat transfer characteristics such as natural and forced convection coefficients. Temperature distributions are analyzed by using the finite element method. Results of analysis are compared.

  • PDF

A Study on the Thermal Characteristics of the High Speed Spindle considering Heat Transfer (열전달을 고려한 고속 주축계의 열특성 해석에 관한 연구)

  • 백경근;김수태;최대봉;김태형
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.285-290
    • /
    • 2000
  • Unsteady-state temperature distributions and thermal deformations in high speed spindle are studied. For the analysis, three dimensional model is built considering heat transfer characteristics such as natural and forced convection coefficients Temperature distributions and thermal deformations are analyzed by using the finite element method. Results of analysis are compared with the measured data.

  • PDF