• Title/Summary/Keyword: national statistical system

Search Result 1,563, Processing Time 0.031 seconds

Bioequivalence of Levopid Tablet to Levopride Tablet (Levosulpiride 25 mg) (레보프라이드 정(레보설피리드 25 mg)에 대한 레보피드 정의 생물학적 동등성)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2002
  • Levosulpiride is the 1evo-enantiomer form of racemic sulpiride, a benzamide derivative selectively inhibiting dopaminergic $D_2$ receptors at the trigger zone both in the central nervous system and in the gastrointestinal tract. The purpose of the present study was to evaluate the bioequiva1ence of two levosulpiride tablets, Levopride (SK Pharmaceutical Co., Ltd.) and Levopid (Dae Won Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The levosulpiride release from the two levosulpiride tablets in vitro was tested using KP VII Apparatus II method with various different kinds of dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty eight normal male volunteers, $23.82{\pm}3.26$ years in age and $69.13{\pm}8.58$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 25 mg of levosulpiride was orally administered, blood was taken at predetermined time intervals and the concentrations of levosulpiride in serum were determined using HPLC method with fluorescence detector. The dissolution profiles of two levosulpiride tablets were very similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t\;and\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on the Levopride were -1.17%, 1.20% and -1.09%, respectively. There were no sequence effects between two tablets in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) $(e.g.,\;log(0.93){\sim}log(1.07)\;and\;log(0.90){\sim}log(1.14)\;for\;AUC_t\;and\;C_{max}$, respectively). The 90% confidence interval using untransformed data was within ${\pm}20%$ $(e.g.,\;-19.47{\sim}16.20\;for\;T_{max})$. All parameters met the criteria of KFDA guideline for bioequivalence, indicating that Levopid tablet is bioequivalent to Levopride tablet.

An Estimation of Probable Precipitation and an Analysis of Its Return Period and Distributions in Busan (부산지역 확률강수량 결정에 따른 재현기간 및 분포도 분석)

  • Lim, Yun-Kyu;Moon, Yun-Seob;Kim, Jin-Seog;Song, Sang-Keun;Hwang, Yong-Sik
    • Journal of the Korean earth science society
    • /
    • v.33 no.1
    • /
    • pp.39-48
    • /
    • 2012
  • In this study, a statistical estimation of probable precipitation and an analysis of its return period in Busan were performed using long-term precipitation data (1973-2007) collected from the Busan Regional Meteorological Administration. These analyses were based on the method of probability weighted moments for parameter estimation, the goodness-of-fit test of chi-square ($x^2$) and the probability plot correlation coefficient (PPCC), and the generalized logistics (GLO) for optimum probability distribution. Moreover, the spatial distributions with the determination of probable precipitation were also investigated using precipitation data observed at 15 Automatic Weather Stations (AWS) in the target area. The return periods for the probable precipitation of 245.2 and 280.6 mm/6 hr with GLO distributions in Busan were estimated to be about 100 and 200 years, respectively. In addition, the high probable precipitation for 1-, 3-, 6-, and 12-hour durations was mostly distributed around Dongrae-gu site, all coastal sites in Busan, Busanjin and Yangsan sites, and the southeastern coastal and Ungsang sites, respectively.

A Study on the Application of the Korean Valuation Weights for EuroQoL-5 Dimension (EuroQoL-5 Dimension 한국 가중치 모형의 적용 연구)

  • Lee, Young-Hoon;Choi, Jin-Su;Rhee, Jung-Ae;Ryu, So-Yeon;Shin, Min-Ho;Kim, Jin-Hee
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.1
    • /
    • pp.1-13
    • /
    • 2009
  • Objectives: This study was conducted to estimate the health-related quality of life (HRQOL) using EuroQoL-5 Dimension (EQ-5D) and to identify its related factors among urban-dwelling adults. Methods: The data for this study were obtained from 1,134 subjects aged $20\sim91$, who participated in 'Survey on the health status and demand for health' in two cities of Korea (Dong-gu, Gwangju and Suncheon-si, Jeollanamdo). The HRQOL was measured using the EQ-5D instrument and EQ-5D index scores were calculated by two Korean valuation study model using time trade-off method. Results: The mean EQ-5D index scores for all subjects were $0.865{\pm}0.218$ (model A), and $0.921{\pm}0.170$ (model B). The EQ-5D index score was significantly different according to demographic and socioeconomic characteristics (gender, age, marital status, education, occupation, income, and health security system), self-rated health condition, health-related psychological assessments (enough sleep, fatigue rate, stress rate, and degree of satisfaction on the residence). The results of multiple linear regression showed that age, marital status, income, coverage of medical insurance, self-rated health condition, and fatigue rate were significantly related common statistical factors of HRQOL in two Korean valuation study model. Conclusion: Among the adults residing in urban environment, the HRQOL was significantly lower on the subjects with following conditions: higher age, being alone without a spouse as a result of death, divorce or separation, low income, medical aid program, poor self-rated health condition, and chronic fatigue. In order to improve the urban adults' quality of life, healthcare policy and health promotion program must be developed with considerations to factors related to the HRQOL.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

Determination of Hot Air Drying Characteristics of Squash (Cucurbita spp.) Slices

  • Hong, Soon-jung;Lee, Dong Young;Park, Jeong Gil;Mo, Changyeun;Lee, Seung Hyun
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2017
  • Purpose: This study was conducted to investigate the hot air drying characteristics of squash slices depending on the drying conditions (input air velocity, input air temperature, and sample thickness). Methods: The developed drying system was equipped with a controllable air blower and electric finned heater, drying chamber, and ventilation fan. Squash (summer squash called Korean zucchini) samples were cut into slices of two different thicknesses (5 and 10 mm). These were then dried at two different input air temperatures (60 and $70^{\circ}C$) and air velocities (5 and 7 m/s). Six well-known drying models were tested to describe the experimental drying data. A non-linear regression analysis was applied to determine model constants and statistical indices such as the coefficient of determination ($R^2$), reduced chi-square (${\chi}^2$), and root mean square error (RMSE). In addition, the effective moisture diffusivity ($D_{eff}$) was estimated based on the curve of ln(MR) versus drying time. Results: The results clearly showed that drying time decreased with an increase in input air temperature. Slice thickness also affected the drying time. Air velocity had a greater influence on drying time at $70^{\circ}C$ than at $60^{\circ}C$ for both thicknesses. All drying models accurately described the drying curve of squash slices regardless of slice thickness and drying conditions; the Modified Henderson and Pabis model had the best performance with the highest R2 and the lowest RMSE values. The effective moisture diffusivity ($D_{eff}$) changes, obtained from Fick's diffusion method, were between $1.67{\times}10^{-10}$ and $7.01{\times}10^{-10}m^2/s$. The moisture diffusivity was increased with an increase in input air temperature, velocity, and thickness. Conclusions: The drying time of squash slices varied depending on input temperature, velocity, and thickness of slices. The further study is necessary to figure out optimal drying condition for squash slices with retaining its original quality.

A Study on the Comparative Analysis of Fire-Fighting Ambulances about the Aspects of Safety and Efficiency using the Question Investigation (설문조사를 이용한 국내 소방 구급자동차의 안전성과 효율성 측면에서의 비교 분석에 관한 연구)

  • Shin, Dong-Min;Kim, Seung-Yong;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.44-53
    • /
    • 2015
  • This study is a survey research to improve the fire-fighting ambulance interior design safer and more efficient to identify the type of structure and functional problems 119 ambulance. When the paramedics and four degrees to over 755 people modify the target report and related literature on the future development of an ambulance for patient safety at the 2007 British National Patients Safety Agency (NPSA) and was used as a complementary tool. General characteristics questionnaire was composed of items for your design improvements for ambulance promote safety and efficiency. The data were collected by distributing a questionnaire e-mail or in person. The collected data were processed using the SPSS 20.0 statistical program, the general characteristics as frequency analysis, percentage, ambulance interior design improvement-related items were analyzed using the chi-square verified. As a result, this research elicited that vans converted fire ambulance cars have a problem with the narrow interior space and truck converted fire ambulance cars should be comfortable to drive in ride quality. In addition, we also found that the improvement of paramedics treatment position and the paramedic's personnel safety belt are required. Based on these results, we propose that a number of improvements are needed in the fire-fighting ambulance car.

COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES (학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교)

  • Kang, Mun-Seong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose of this study was to compare the shaping ability of three Ni-Ti file systems used by dental students or the experts and consequently to aid in choosing a proper systems for educational courses of dental students and beginners. Fifty students and ten dentists who have clinical experience over two years prepared 180 simulated root canals in resin blocks with three Ni-Ti systems; $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$. After preparation, the Ni-Ti files were evaluated for distortion and canal preparation time was recorded. The images of pre- and post-instrumented canals were scanned and superimposed. Amounts of increased canal widths, deviation, and centering ratio were calculated at apical 1, 3 and 5 mm levels and statistical analysis was performed The results were as follows : 1. HS showed the shortest preparation time and instrumented canal width in K3 was significantly larger than other groups (P<0.05). 2. At 1 and 3mm levels, all groups had outward deviation. In student group, at the 1mm level, PF had the least deviation (P<0.05). 3. In the centering ratio, the PF had the best centering ability compared to the others at 5mm level. At 1 and 3mm levels, HS and PF had better abilities than K3. Student group had better ratio than the expert at 3mm level with PF (P<0.05). Based on the results, it is surmised that the $ProFile^{(R)}$ is the safest and most ideal instrument for students and beginners.

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

The Search of Pig Pheromonal Ordorants for Biostimulation Control System Technology: IV. Comparative Molecular Similarity Indices Analyses (CoMSIA) on the Binding Affinities between Ligands of 2-(Cyclohexyloxy)-tetrahydrofurane Derivatives and Porcine Ordorant Binding Protein (생물학적 자극 통제 수단으로 활용하기 위한 돼지 페로몬성 냄새 물질의 탐색: IV. 2-(Cyclohexyloxy)tetrahydrofurane 유도체와 Porcine Odorant Binding Protein 사이의 결합 친화력에 관한 비교분자 유사성 지수분석(CoMSIA))

  • Sung, Nack-Do;Park, Chang-Sik;Jang, Seok-Chan;Choi, Kyung-Seob
    • Reproductive and Developmental Biology
    • /
    • v.30 no.3
    • /
    • pp.169-174
    • /
    • 2006
  • To search of a new porcine pheromonal odorants, the comparative molecular similarity indices analysis(CoMSIA) between porcine odorant binding protein(pOBP) as receptor and ligands of green odorants 2-(Cyclohexyloxy)tetrahydrofurane derivatives as substrate molecule were conducted and disscused quantitatively. In the optimized CoMSIA model(I-AI) with chirality($I:\;C_{1'}(R),\;C_2(S)$) in substrate molecules and atom based fit alignment(AE) of the odorants the statistical PLS results showed the best predictability of the binding affinities based on the LOO cross-validated value ${r^2}_{cv.}\;(q^2=0.856)$ and non cross-validated conventional coefficient(${r^2}_{ncv.}=0.964)$). The structural distinctions of the highest active molecules were able to understand from the interaction between pOBP and green odorants in the contour maps with CoMSIA model.

Is the Spinal Instability Neoplastic Score Accurate and Reliable in Predicting Vertebral Compression Fractures for Spinal Metastasis? A Systematic Review and Qualitative Analysis

  • Lee, Chang-Hyun;Hong, Jae Taek;Lee, Sun-Ho;Yi, Seong;Sohn, Moon-Jun;Kim, Sung Hwan;Chung, Chun Kee;Korean Spine Oncology Research Society
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.4-12
    • /
    • 2021
  • Spinal metastases can present with varying degrees of mechanical instability. The Spinal Instability Neoplastic Score (SINS) was developed as a tool to assess spinal neoplastic-related instability while helping to guide referrals among oncology specialists. Some previous papers suggested that the SINS was accurate and reliable, while others disagreed with this opinion. We performed a systematic review regarding the SINS to evaluate its accuracy and precision in predicting vertebral compression fractures (VCFs). The 21 included studies investigated a total of 2118 patients. Thirteen studies dealt with the accuracy of SINS to predict post-radiotherapy VCFs, and eight dealt with the precision. Among 13 studies, 11 agreed that the SINS categories showed statistically significant accuracy in predicting VCF. Among eight studies, body collapse was effective for predicting VCFs in six studies, and alignment and bone lesion in two studies. Location has no statistical significance in predicting VCFs in any of the eight studies. The precision of SINS categories was substantial to excellent in six of eight studies. Among the six components of the SINS, the majority of the included studies reported that location showed near perfect agreement; body collapse, alignment, and posterolateral involvement showed moderate agreement; and bone lesion showed fair agreement. Bone lesion showed significant accuracy in predicting VCFs in half of eight studies, but displayed fair reliability in five of seven studies. Although location was indicated as having near perfect reliability, the component showed no accuracy for predicting VCFs in any of the studies and deleting or modifying the item needs to be considered. The SINS system may be accurate and reliable in predicting the occurrence of post-radiotherapy VCFs for spinal metastasis. Some components seem to be substantially weak and need to be revised.