• Title/Summary/Keyword: myocardial perfusion score

Search Result 24, Processing Time 0.026 seconds

Lung/Heart Uptake Ratio in Dipyridamole $^{99m}Tc-MIBI$ Myocardial Perfusion Scan in Coronary Artery Disease (관상동맥질환에서 디피리다몰 부하 $^{99m}Tc-MIBI$ 심근스캔의 폐/심장 섭취율)

  • Kang, Keon-Wook;Lee, Dong-Soo;Choi, Chang-Woon;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Jung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.218-222
    • /
    • 1993
  • Lung/heart uptake ratio (L/H R) in $^{201}Tl$ myocardial perfusion scan is a reliable marker for long-term prognosis in patients with coronary artery disease. However, the value of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan is controversial in determining the prognosis and severity of the coronary artery disease. The purpose of this study was to determine the clinical implications of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan. Forty five patients who received $^{99m}Tc-MIBI$ myocardial perfusion scan were divided into control group and coronary artery disease (CAD) group by their clinical findings, EKGs, and $^{99m}Tc-MIBI$ myocardial perfusion scans. Twenty five patients in CAD group were divided into ischemic group and infarct group according to their results from $^{99m}Tc-MIBI$ myocardial perfusion scan. L/H R was calculated on the anterior planar view, 60 minutes after infusion of dipyridamole. Two regions of interest (ROI) were placed on the left lung area 8 pixel above the left ventricle and on the myocardial area which had the highest radioactivity. In the control group, there were no significant differences of L/H R according to sex and age. No significant difference of L/H R was found between the control and CAD group ($0.26{\pm}0.06,\;0.29{\pm}0.05$, p>0.05). In the CAD group, there was also no significant difference of L/H R between the ischemic group and infarct group ($0.29{\pm}0.07,\;0.30{\pm}0.04$, p>0.05). L/H R in CAD group did not show correlations with the defect area of stress polar map (r=0.18, p >0.05) and with the sum of severity weighted extent score or reversibility score which represent severity and extent of myocardial perfusion defect area in stress (r=0.18, p>0.05). We conclude that it is difficult to use L/H R as a marker for severity of CAD in dipyridamole $^{99m}Tc-MIBI$ myocardial perfusion scan.

  • PDF

Evaluation of Result of Coronary Artery Bypass Graft Surgery by Using Pre and Postoperative Myocardial SPECT (관동맥우회술 전후의 심근 SPECT를 이용한 수술 결과의 평가)

  • 이장훈;한승세
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1083-1091
    • /
    • 1997
  • This study was purposed to assess the result of coronary artery bypass graft surgery by analyzing and comparing the pre and postoperative myocardial perfusion state quantitatively by using myocardial SPECT. Twenty patients who received coronary artery bypass graft surgery since 1993 underwent both preoperative and postoperative myocardial SPECT and the result were analyzed. The mean age was 56.4$\pm$9.0 years, and the patients were composed of thirteen males and seven females. For quantitative analysis, we used polar maps of SPECT generated by Cedars-Sin i Medical Center program and we calculated perfusion scores, ischemic myocardial area ratios and reperfusion scores from polar maps. Preoperative mean stressfrest perfusion score was 7.3$\pm$ 1.117.7$\pm$ 1.0 and postoperative score was 8.1 $\pm$ 1 118.3$\pm$ 1.1. Preoperative mean stress ischemic myocardial area ratio was 0.32$\pm$0.2 and postoperative ratio was 0.15 $\pm$0.1. Postoperative mean perfusion score was significantly increased but, on the other hand, mean ischemic myocardial area ratio was significantly decreased as compared with preoperative values(p<0.01). Preoperative mean perfusion score of patients with postoperative roper(usion score more than 1.5 was significantly higher(p<0.01) than that of patients with postoperative reperfusion score less than 1.5. Preoperative perfusion scores of coronary artery territories that had fixed perfusion defect at myocardial SPECT were significantly low(4.3 $\pm$0.514.6$\pm$0.6, stresslrest), nevertheless it proved quantitatively that there was improvement in myocardial perfusion after surgery by showing improved perfusion scores postoperatively. In conclusion, myocardial SPECT is useful method for quantitative analysis of the myocardial perfusion state after coronary artery bypass grafting surgery.

  • PDF

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Myocardial Perfusion Scoring System in Coronary Bypass Grafting - Estimation of Completeness - (관상동맥우회술 환자에서의 심근관류점수제에 대한 연구: 완전혈관재생술의 평가)

  • Chae, Hurn;Baek,Wan-Ki;Ahn, Hyuk;Kim, Yong-Jin;Rho, Joon-Ryang;Kim, Chong-Whan;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.24 no.9
    • /
    • pp.881-889
    • /
    • 1991
  • The ideal goal of the coronary artery bypass surgery is complete revascularization. To estimate the numerical degree of completeness of revascularization, the following formula was used in 50 patients having aorta-coronary bypass grafting for the treatment of unstable angina. myocardial perfusion score of revascularized area Degree of Completeness = ----------------------------------------------------------------------------- x100[%] preoperative myocardial perfusion score Randomized patients who underwent revascularization procedures in 19Hb were compared with the patients who received similar elective operation each year from 1988 through 1991. To obtain these data, the patients aged 38 ~ 75[mean 54$\pm$9.1years], composed of 31 males and 19 females were randomly sampled. The number of grafts per patient increased from 2.30 in 1986, to 3.07 in 1988 - 89, to 3.21 in 1990, and to 3.50 in 1991. [0.05 The degree of completeness improved from 75.4% to 81.4%, 91.6% and 88.6% respectively. It improved significantly in the last two years, [P<0.05, Mann-Whitney U test] At a follow-up of three months, 90 percent[45/50] of patients remained angina, free, 6 percent[3/50] had residual angina, and 4 percent[2/50] died. The last two patients degree of completeness corresponded to 43% and 30% respectively As a conclusion, the degree of completeness seems to improve year by year, and to have close relationship with the clinical results.

  • PDF

Comparison of Polar Maps of Dipyridamole Stress/Rest MIBI Myocardial SPECT and Coronary Angiography in Coronary Artery Disease (관동맥질환에서 디피리다몰부하 $^{99m}Tc$-MIBI 심근 SPECT 극성지도와 관동맥 조영소견의 비교)

  • Lee, Myung-Chul;Lee, Dong-Soo;Lee, Myung-Yong;Choi, Chang-Woon;Sohn, Dae-Won;Chung, June-Key;Lee, Myong-Mook;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • We have anlayzed the polar maps of dipyridamole stress/rest $^{99m}Tc$-MIBI SPECT and compared the quantitated perfusion defects of dipyridamole stress polar map and the findings of coronary angiography in 56 pateints with coronary artery diseases. We performed the same day dipyridamole stress-rest myocardial SPECT, reconstructed the polar maps according to Cedars-Sinai method and quantitated perfusion detects of total myocardium and the territory of each artery, comparing the polar maps of patients with normal files. Stenosis more than 50 percent was considered significant and myocardial ischemic score was calculated as summed score of percents of main coronary arteries. Positive concordance of myocardial SPECT with coronary angiography were 82.6% with left anterior descending artery (LAD), 85.7% with left circumflex artery (LCx) and 78.6% with right coronary artery (RCA). Perfusion defect of SPECT polar map and the stenosis of coronary artery showed the contingency phi of 0.55 (p<0.0001) with total atreries, 0.38 (p = 0.016) with LAD, 0.50 (p<0.0001) with LCx and 0.40 (p = 0.007) with RCA. Dipyridamole stress percent defect of polar map was correlated with myocardial ischemic score with Spearman's rho of 0.47 (p = 0.001) in total arteries, 0.48 (p=0.001) in LAD, 0.56 (p < 0.001) in LCx and 0.38 (p=0.002) in RCA. These findings revealed that defect of the dipyridamole stress myocardial $^{99m}Tc$-MIBI SPECT and the percent extent of this defect were related with significant artery stenosis of individual arteries and the degree of stenosis. We thought that we could use the defects in the polar map of dipyridamole stress $^{99m}Tc$-MIBI SPECT for the quantification of myocardiasl perfusion decrease.

  • PDF

Role of Redistribution and 24 Hour Reinjection Images to assess Myocardial Viability in Patients with Acute Myocardial Infarction (급성심근경색환자의 심근생존능 평가에 있어서 T1-201 재분포영상과 24시간 재주사영상의 역할)

  • Yoon, Seok-Nam;Pai, Moon-Sun;Park, Chan-H.;Yoo Myung-Ho;Choi, Byung-Il William
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.325-331
    • /
    • 1998
  • Purpose: We evaluated the importance of redistribution and 24 hour reinjection images in T1-201 SPECT assessment of myocardial viability after acute myocardial infarction (AMI). Materials and Methods: We performed dipyridamole stress-4 hour redistribution-24 hour reinjection T1-201 SPECT in 43 patients with recent AMI (4-16 days). The myocardium was divided into 16 segments and perfusion grade was measured visually with 4 point score from 0 to 3 (absent uptake to normal uptake). A perfusion defect with stress score 2 was considered moderate. A defect was considered severe if the stress score was 0 or 1 (absent uptake or severe perfusion decrease). Moderate defect on stress image were considered viable and segments with severe defect were considered viable if they showed improvement of 1 score or more on redistribution or reinjection images. We compared the results of viability assessment in stress-redistribution and stress-reinjection images. Results: On visual analysis, 344 of 688 segments (50%) had abnormal perfusion. Fifty two (15%) had moderate perfusion defects and 292 (85%) had severe perfusion defects on stress image. Of 292 severe stress defects, 53 were irreversible on redistribution and reversible on reinjection images, and 15 were reversible on redistribution and irreversible on reinjection images. Two hundred twenty four of 292 segments (76.7%) showed concordant results on stress-redistribution and stress-reinjection images. Therefore 24 hour reinjection image changed viability status from necrotic to viable in 53 segments of 292 severe stress defect (18%). However, myocardial viability was underestimated in only 5% (15/292) of severe defects by 24 hour reinjection. Conclusion: The 24 hour reinjection imaging is useful in the assessment of myocardial viability. It is more sensitive than 4 hour redistribution imaging. However, both redistribution and reinjection images are needed since they complement each other.

  • PDF

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

Predictive Values of Early Rest/24 Hour Delay T1-201 Perfusion SPECT for Wall Motion Improvement in Patients with Acute Myocardial Infarction After Reperfusion (급성 심근 경색 환자에서 재관류 후 조기에 시행한 휴식/24시간 지연 T1-201 심근 SPECT의 심근벽 운동 호전 예측능)

  • Hyun, In-Young;Kwan, June
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.259-265
    • /
    • 1998
  • Purpose: We studied early rest/24 hour delay T1-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Materials and Methods: Among 17 patients (male/female= 11/6, age: $59{\pm}13$) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay: 11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct-related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest T1-201 perfusion SPECT less then 6 hours after reperfusion and delay T1-201 perfusion SPECT next day. T1-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest T1-201 uptake ${\le}2$ or combination of rest T1-201 uptake ${\le}2$ or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ${\ge} 1$ grade in follow up echo compared with the baseline values. Results: Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest T1-201 uptake were 99%, and 54%. PPV and NPV of rest T1-201 uptake were 100% and 52% respectively. Predictive values of combination of rest T1-201 uptake and late reversibility were not significantly different compared with predictive values of rest T1-201 uptake only. Conclusion: We conclude that early T1-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative predictive values in patients with acute myocardial infarction after reperfusion.

  • PDF

The Clinical Efficacy of Lung to Heart Ratio in 1 Hour Delayed Tc-99m Tetrofosmin Gated Myocardial SPECT after Adenosine Stress: Comparison with Coronary Angiography (아데노신 부하 1시간 지연 Tc-99m tetrofosmin 게이트 심근 SPECT에서 관찰되는 심장 대 폐 섭취비의 임상적 유용성: 관상동맥조영술과의 비교)

  • Won, Kyoung-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.362-368
    • /
    • 2008
  • Purpose: It is well known that lung to heart ratio (LHR) is one of the high risk findings in TI- 201 myocardial perfusion SPECT. We evaluated the clinical efficacy of LHR to identify severe coronary artery disease in adenosine stress Tc-99m tetrofosmin gated myocardial perfusion SPECT (gSPECT). Materials and Methods: The study population was 157 patients who underwent both adenosine stress Tc-99m gSPECT and coronary angiography (CAG) within one month. According to the results of CAG and gSPECT LHR and the incidence of increased LHR were compared. Results: Among 53 patients with normal coronary arteries increased LHR was found in 2 patients (3.8%) and 0 in 44 patients (0%) with one vessel disease, 2 in 27 with two vessel disease (7.4%) and 8 in 33 with triple vessel disease (24.2%). Significant differences were found in LHR between subgroups of summed stress score, summed rest score and LV ejection fraction (LVEF). There were weak negative correlation between LHR and LVEF and weak positive correlation between LHR and SSS and SRS. Conclusion: Increased LHR had higher incidence in patients with triple vessel disease, severe LV dysfunction and/or extensive perfusion defect than those of normal group. Although its sensitivity might be low to identify severe coronary artery disease, LHR could be helpful in abnormal myocardial perfusion SPECT to stratify risk and prognosis.

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF