• Title/Summary/Keyword: multiple measurements

Search Result 801, Processing Time 0.031 seconds

Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm (Pencil Beam 알고리즘 기반의 상용 치료계획 시스템을 이용한 전자선 회전 치료 계획의 구현 및 정확도 평가)

  • Kang, Sei-Kwon;Park, So-Ah;Hwang, Tae-Jin;Cheong, Kwang-Ho;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.304-310
    • /
    • 2010
  • Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode, no commercial planning systems for the electron arc plan are available at this time. In this work, with the expectation that an easily accessible planning system could promote electron arc therapy, a commercial planning system was commissioned and evaluated for the electron arc plan. For the electron arc plan with use of a Varian 21-EX, Pinnacle3 (ver. 7.4f), with an electron pencil beam algorithm, was commissioned in which the arc consisted of multiple static fields with a fixed beam opening. Film dosimetry and point measurements were executed for the evaluation of the computation. Beam modeling was not satisfactory with the calculation of lateral profiles. Contrary to good agreement within 1% of the calculated and measured depth profiles, the calculated lateral profiles showed underestimation compared with measurements, such that the distance-to-agreement (DTA) was 5.1 mm at a 50% dose level for 6 MeV and 6.7 mm for 12 MeV with similar results for the measured depths. Point and film measurements for the humanoid phantom revealed that the delivered dose was more than the calculation by approximately 10%. The electron arc plan, based on the pencil beam algorithm, provides qualitative information for the dose distribution. Dose verification before the treatment should be mandatory.

Comparison of IVF-ET Outcomes between GnRH Antagonist Multiple Dose Protocol and GnRH Agonist Long Protocol in Patients with High Basal FSH Level or Advanced Age (높은 기저 난포 자극 호르몬 수치를 가지는 환자와 고령 환자의 체외수정시술을 위한 과배란 유도에서 GnRH antagonist 다회 투여법과 GnRH agonist 장기요법의 효용성에 대한 연구)

  • Kim, JY;Kim, NK;Yoon, TK;Cha, SH;Kim, YS;Won, HJ;Cho, JH;Cha, SK;Chung, MK;Choi, DH
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.32 no.4
    • /
    • pp.315-324
    • /
    • 2005
  • Objectives: To compare the efficacy of GnRH antagonist multiple dose protocol (MDP) with that of GnRH agonist long protocol (LP) in controlled ovarian hyperstimulation for in vitro fertilization in patients with high basal FSH (follicle stimulating hormone) level or old age, a retrospective analysis was done. Methods: Two hundred ninety four infertile women (328 cycles) who were older than 41 years of age or had elevated basal FSH level (> 8.5 mIU/mL) were enrolled in this study. The patients had undergone IVF-ET after controlled ovarian hyperstimulation using GnRH antagonist multiple dose protocol (n=108, 118 cycles) or GnRH agonist long protocol (n=186, 210 cycles). The main outcome measurements were cycle cancellation rate, consumption of gonadotropins, the number of follicles recruited and total oocytes retrieved. The number of fertilized oocytes and transferred embryos, the clinical pregnancy rates, and the implantation rates were also reviewed. And enrolled patients were divided into three groups according to their age and basal FSH levels; Group A - those who were older than 41 years of age, Group B - those with elevated basal FSH level (> 8.5 mIU/mL) and Group C - those who were older than 41 years of age and with elevated basal FSH level (> 8.5 mIU/mL). Poor responders were classified as patients who had less than 4 retrieved oocytes, or those with $E_2$ level <500 pg/mL on the day of hCG injection or those who required more than 45 ampules of exogenous gonadotropin for stimulation. Results: The cancellation rate was lower in the GnRH antagonist group than in GnRH agonist group, but not statistically significant (6.8% vs. 9.5%, p=NS). The amount of used gonadotropins was significantly lower in GnRH antagonist group than in agonist group ($34.8{\pm}11.3$ ampules vs. $44.1{\pm}13.4$ ampules, p<0.001). The number of follicles > 14 mm in diameter was significantly higher in agonist group than in antagonist group ($6.7{\pm}4.6$ vs. $5.0{\pm}3.4$, p<0.01). But, there were no significant differences in clinical pregnancy rate (24.5% in antagonist group vs. 27.4% in agonist group, p=NS) and implantation rate (11.4% in antagonist group vs. 12.0% in agonist group, p=NS) between two groups. Mean number of retrieved oocytes was significantly higher in GnRH agonist LP group than in GnRH antagonist MDP group ($5.4{\pm}3.5$ vs. $6.6{\pm}5.0$, p<0.0001). But, the number of mature and fertilized oocytes, and the number of good quality (grade I and II) and transferred embryos were not different between two groups. In each group A, B, and C, the rate of poor response did not differ according to stimulation protocols. Conclusions: In conclusion, for infertile women expected poor ovarian response such as who are old age or has elevated basal FSH level, a protocol including a controlled ovarian hyperstimulation using GnRH antagonist appears at least as effective as that using a GnRH agonist, and may offer the advantage of reducing gonadotropin consumption and treatment period. However, much work remains to be done in optimizing the GnRH antagonist protocols and individualizing these to different cycle characteristics.

A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field (다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구)

  • Kim Joo-Ho;Lee Sang-Gyu;Shin Hyun-Kyung;Lee Suk;Na Soo-Kyung;Cho Jung-Hee;Kim Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Purpose : Many authors have been introduced field in field technique and 3-D conformal radiotherapy that increased the tumor dose as well as decreased the dose of abutting critical organ. These technique have multiple beam direction and small beam segments even below 10 MU(monitor unit)for each field. we have confirmed the influence of low MU on dose output and beam stability. Materials and Methods : To study the dose output, the dose for each field was always 90MU, but it divided into different segment size: 1, 2, 3, 5, 10, 15 segments, 90, 45, 30, 18, 9, 6 MU the measurements were carried out for X-ray energy 4 MV, 6 MV, 10 MV of three LINAC(Varian 600C, 2100C, 2100C, 2100C/D), in addition each measurement was randomly repeated three times for each energy. To study the field symmetry and flatness, X-omat V films were irradiated. After being developed, films were scanned and analyzed using densitometer. Results : Influence of low MU on dose is slightly more increase output about $1.2{\sim}2.9%$ in cGy/mu than 90MU, but may not changed beam quality(flatness or symmetry), Output stability depends on dose rate(PRF)rather than beam energy, field size. Conclusion : Presented result are under the limits(out put<3%, flatness<${\pm}3%$, symmetry<2%). The 3 accelerators are safe to use and to perform conformal radiotherapy treatments in small segments, small MU around 10MU. but Even if the result presented here under the limits, continuous adjustments and periodic QA should be done for use of small MU

  • PDF

Growth Temperature Effects of In0.5Al0.5As Buffer Layer on the Optical Properties of In0.5Ga0.5As/In0.5Al0.5As Multiple Quantum Wells Grown on GaAs (GaAs 기판 위에 성장한 In0.5Ga0.5As/In0.5Al0.5As 다중양자우물의 광학적 특성에 대한 In0.5Al0.5As 버퍼층 성장온도의 영향)

  • Kim, Hee-Yeon;Oh, H.J.;Ahn, S.W.;Ryu, Mee-Yi;Lim, J.Y.;Shin, S.H.;Kim, S.Y.;Song, J.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.211-216
    • /
    • 2010
  • The luminescence properties of $In_{0.5}Ga_{0.5}As/In_{0.5}Al_{0.5}As$ multiple quantum wells (MQWs) grown on $In_{0.5}Al_{0.5}As$ buffer layers have been studied by using photoluminescence (PL) and time-resolved PL measurements. A$1-{\mu}m$ thick $In_{0.5}Al_{0.5}As$ buffer layers were deposited on a 500 nm thick GaAs layer, followed by the deposition of the InGaAs/InAlAs MQWs. In order to investigate the effects of InAlAs buffer layer on the optical properties of the MQWs, four different temperature sequences are used for the growth of InAlAs buffer layer. The growth temperature for InAlAs buffer layer was varied from 320^{\circ}C to $580^{\circ}C$. The MQWs consist of three $In_{0.5}Ga_{0.5}$As wells with different well thicknesses (2.5 nm, 4.0 nm, and 6.0 nm thick) and 10 nm thick $In_{0.5}Al_{0.5}$As barriers. The PL spectra from the MQWs with InAlAs layer grown at lower temperature range ($320-580^{\circ}C$) showed strong peaks from 4 nm QW and 6 nm QW. However, for the MQWs with InAlAs buffer grown at higher temperature range ($320-480^{\circ}C$), the PL spectra only showed a strong peak from 6 nm QW. The strongest PL intensity was obtained from the MQWs with InAlAs layer grown at the fixed temperature of $480^{\circ}C$, while the MQWs with buffer layer grown at higher temperature from $530^{\circ}C$ to $580^{\circ}C$ showed the weakest PL intensity. From the emission wavelength dependence of PL decay times, the fast and slow decay times may be related to the recombination of carriers in the 4 nm QW and 6 nm QW, respectively. These results indicated that the growth temperatures of InAlAs layer affect the structural and optical properties of the MQWs.

M-mode Ultrasound Assessment of Diaphragmatic Excursions in Chronic Obstructive Pulmonary Disease : Relation to Pulmonary Function Test and Mouth Pressure (만성폐쇄성 폐질환 환자에서 M-mode 초음파로 측정한 횡격막 운동)

  • Lim, Sung-Chul;Jang, Il-Gweon;Park, Hyeong-Kwan;Hwang, Jun-Hwa;Kang, Yu-Ho;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.736-745
    • /
    • 1998
  • Background: Respiratory muscle interaction is further profoundly affected by a number of pathologic conditions. Hyperinflation may be particularly severe in chronic obstructive pulmonary disease(COPD) patients, in whom the functional residual capacity(FRC) often exceeds predicted total lung capacity(TLC). Hyperinflation reduces the diaphragmatic effectiveness as a pressure generator and reduces diaphragmatic contribution to chest wall motion. Ultrasonography has recently been shown to be a sensitive and reproducible method of assessing diaphragmatic excursion. This study was performed to evaluate how differences of diaphragmatic excursion measured by ultrasonography associate with normal subjects and COPD patients. Methods: We measured diaphragmatic excursions with ultrasonography on 28 healthy subjects(l6 medical students, 12 age-matched control) and 17 COPD patients. Ultrasonographic measurements were performed during tidal breathing and maximal respiratory efforts approximating vital capacity breathing using Aloka KEC-620 with 3.5 MHz transducer. Measurements were taken in the supine posture. The ultrasonographic probe was positioned transversely in the midclavicular line below the right subcostal margin. After detecting the right hemidiaphragm in the B-mode the ultrasound beam was then positioned so that it was approximately parallel to the movement of middle or posterior third of right diaphragm. Recordings in the M-mode at this position were made throughout the test. Measurements of diaphragmatic excursion on M-mode tracing were calculated by the average gap in 3 times-respiration cycle. Pulmonary function test(SensorMedics 2800), maximal inspiratory(PImax) and expiratory mouth pressure(PEmax, Vitalopower KH-101, Chest) were measured in the seated posture. Results: During the tidal breathing, diaphragmatic excursions were recorded $1.5{\pm}0.5cm$, $1.7{\pm}0.5cm$ and $1.5{\pm}0.6cm$ in medical students, age-matched control group and COPD patients, respectively. Diaphragm excursions during maximal respiratory efforts were significantly decreased in COPD patients ($3.7{\pm}1.3cm$) when compared with medical students, age-matched control group($6.7{\pm}1.3cm$, $5.8{\pm}1.2cm$, p< 0.05}. During maximal respiratory efforts in control subjects, diaphragm excursions were correlated with $FEV_1$, FEVl/FVC, PEF, PIF, and height. In COPD patients, diaphragm excursions during maximal respiratory efforts were correlated with PEmax(maximal expiratory pressure), age, and %FVC. In multiple regression analysis, the combination of PEmax and age was an independent marker of diaphragm excursions during maximal respiratory efforts with COPD patients. Conclusion: COPD subjects had smaller diaphragmatic excursions during maximal respiratory efforts than control subjects. During maximal respiratory efforts in COPD patients, diaphragm excursions were well correlated with PEmax. These results suggest that diaphragm excursions during maximal respiratory efforts with COPD patients may be valuable at predicting the pulmonary function.

  • PDF

A Study on the Indoor-Outdoor $NO_2$ Levels and Personal Exposures to $NO_2$ with Analysis of factors Affecting the $NO_2$ Concentrations - Centering on Urban Homes and Housewives - (실내외 $NO_2$농도 및 $NO_2$개인폭로량과 이들에 영향을 미치는 요인에 관한 연구 -도시지역 주택 및 주부를 대상으로-)

  • Chun, Jin-Ho;Lee, Chae-Un;Kim, Joon-Youn;Chung, Yo-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.132-151
    • /
    • 1988
  • This study was conducted to establish the control program for preventing unfavorable health effects of nitrogen dioxide($NO_2$) exposure in homes by preparing the fundamental data for evaluation of relation-ships between $NO_2$ levels and influencing factors through measurements of indoor-outdoor $NO_2$ levels and personal $NO_2$ exposures for housewives with questionnaire survey on 172 homes in Pusan area from April to June, 1987 $NO_2$ measurements were made by using diffusion tube samplers(Palmes tube $NO_2$ sampler) for one week at 4 sites in homes ; kitchen(KIT), bedroom(BED), living room(LIV), outdoor(OUT) and near the collar of housewives(personal exposure livel, PNO). The details of questionnaire were number of household members(FAM), number of regular smokers (SMOKER), daily number of meals eaten(MEAL), type of housing units(HOUSE), location of house with distance from the heavy traffic roads as walking time(DIST), and of kitchen(KAREA), kind of cooking fuels(FUEL), cooking time of each meal(CTIME), usage of kitchen fan for cooking(FAN), type of heating facilities(HEAT) and so on of subject homes. The Obtained results were as fellows : 1) The mean $NO_2$ level was significantly higher at indoors than outdoors(p<0.01) and the kitchen $NO_2$ level was the highest with $33.7{\pm}13.6ppb$(9.5-81.5ppb). The mean personal exposure level of $NO_2$ for housewives was $20.6{\pm}8.8ppb$(3.1-46.9ppb). 2) The mean indoor $NO_2$ level was significantly higher in the group of household members above 5 than below 4(p<0.05), in detached dwellings than apartments(p<0.001), within 5 minutes of distance than over 5 minutes(p<0.001), in the group of unusing fan(p<0.001), in the group of longer cooking time(p<0.001), and it was in order of coal briquette, gas, electricity and oil by kind of cooking fuels(p<0.05). 3) Variables showing significant correlation(p<0.001) with indoor $NO_2$ level were kitchen $NO_2$ level(r=0.8677), cooking time(r=0.5921), outdoor $NO_2$ level(r=0.5192), personal $NO_2$ exposure level(r=0.4615), usage of kitchen fan(r=0.3573) and location of house(r=-0.2988) 4) As a result of multiple regression analysis, the most significant influencing variable to the kitchen $NO_2$ level was cooking time[KIT=$-0.378{\pm}11.772$(CTIME)+0.298(OUT)+3.102(FAN)], it was kitchen $NO_2$ level to the indoor $NO_2$ level[IND=6.996+0.458(KIT)+0.230(OUT)-1.127(KAREA)], and it was indoor $NO_2$ level to the personal $NO_2$ exposure level[PNO=15.562+0.729(IND)-4.542(DIST)-0.200(KIT)] 5) It was recognized that aritificial ventilation in the kitchen, suppression of unnecessary combustion and replacement of cooking fuel, as much as possible, were effective means for decreasing indoor $NO_2$ levels in homes.

  • PDF

Prevalence of Arthritis and Health Behavior Related Risk Factors of the Older Residents in Andong Rural Area (안동 농촌지역 중년 및 노인 주민의 관절염 유병율과 건강습관 관련 위험요인 분석)

  • Lee, Hye-Sang;Kwon, Chong-Suk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1187-1194
    • /
    • 2009
  • This study was performed to estimate the prevalence and the risk factors of arthritis in Andong rural area in 2003. The subjects were 1,462 people (544 males, 818 females) aged 45 years and over. The arthritis group was composed of 322 people (72 males, 250 females), diagnosed by doctor or self-diagnosed by the symptoms. Prevalence of arthritis was higher in female (27.2%) compared to male (13.2%). Mean age of arthritis group was significantly higher than that of normal group (male 66.2 vs 62.8, female 62.6 vs 60.1, p<0.001). The anthropometric measurements, such as % body fat, body mass index (BMI), and waist circumference, and the biochemical measurements, such as plasma triglyceride and total cholesterol level, were significantly higher only in female (not in male) arthritis group than those in normal group. Health related lifestyle factors, such as smoking, alcohol drinking, and exercise, were not different between both groups. The risk factors for arthritis were analyzed using the multiple logistic regression method and expressed as odds ratio (OR). The results showed that female compared to male (OR=1.983), over 65 years compared to 45$\sim$64 years (male OR=2.769 and female OR=1.461), and obese female subjects (not for male) by % body fat ($\geq$32% OR=2.035) or BMI ($\geq$25 kg/$m^2$ OR=1.556) showed significantly higher risk factors for arthritis. Regarding nutrient intakes, higher intakes of fat (OR=1.443), calcium (OR=1.503), iron (OR=1.518) and vitamin A (OR=1.390) in female seemed to be risk factors. In contrast to female, higher intakes of vitamin A (OR=0.526) and riboflavin (OR=0.582) seemed to decrease the risk for arthritis in male. This study revealed that the prevalence of arthritis was significantly higher in female and aged individuals. Also, in order to decrease the prevalence and/or prevention of arthritis, female should prevent overfatness and decrease some nutrient intakes, while male should increase their intakes.

The Effect of Information Service Quality on Customer Loyalty: A Customer Relationship Management Perspective (정보서비스품질이 고객로열티에 미치는 영향에 관한 연구: 고객관계관리 관점)

  • Kim, Hyung-Su;Gim, Seung-Ha;Kim, Young-Gul
    • Asia pacific journal of information systems
    • /
    • v.18 no.1
    • /
    • pp.1-23
    • /
    • 2008
  • As managing customer relationship gets more important, companies are strengthening information service using multi-channels to their customers as a part of their customer relationship management (CRM) initiatives. It means companies are now accepting such information services not as simple information -delivering tools, but as strategic initiatives for acquiring and maintaining customer loyalty. In this paper, we attempt to validate whether or not such various information services would impact on organizational performance in terms of CRM strategy. More specifically, our research objective is to answer the next three questions: first, how to construct the instruments to measure not information quality but information service quality?; second, which attributes of information service quality can influence corporate image and customer loyalty?; finally, does each information service type have unique characteristics compared with others in terms of influencing corporate image and customer loyalty? With respect to providing answers to those questions, the previous studies had been limited in that those studies failed to consider the variety of types of information service or restricted the quality of information service to information quality. An appropriate research model answering the above questions should consider the fact that most companies are utilizing multi channels for their information services, and include the recent strategic information service such as customer online community. Moreover, since corporate information service could be regarded as a type of products or services delivered to customer, it is necessary to adopt the criteria for assessing customer's perceived value when to measure the quality of information service. Therefore, considering both multi-channels and multi-traits may enable us to tell the detailed causal routes showing which quality attributes of which information service would affect corporate image and customer loyalty. As information service channels, we include not only homepage and DM (direct mail), which are the most frequently applied information service channels, but also online community, which is getting more strategic importance in recent years. With respect to information service quality, we abstract information quality, convenience of information service, and timeliness of information service through a wide range of relevant literature reviews. As our dependant variables, we consider corporate image and customer loyalty that both of them are the critical determinants of organizational performance, and also attempt to grasp the relationship between the two constructs. We conducted a huge online survey at the homepage of one of representative dairy companies in Korea, and gathered 367 valid samples from 407 customers. The reliability and validity of our measurements were tested by using Cronbach's alpha coefficient and principal factor analysis respectively, and seven hypotheses were tested through performing correlation test and multiple regression analysis. The results from data analysis demonstrated that timeliness and convenience of homepage have positive effects on both corporate image and customer loyalty. In terms of DM, its' information quality was represented to influence both corporate image and customer loyalty, but we found its' convenience have a positive effect only on corporate image. With respect to online community, we found its timeliness contribute significantly both to corporate image and customer loyalty. Finally, as we expected, corporate image was revealed to provide a great influence to customer loyalty. This paper provides several academic and practical implications. Firstly, we think our research reinforces CRM literatures by developing the instruments for measuring information service quality. The previous relevant studies have mainly depended on the measurements of information quality or service quality which were developed independently. Secondly, the fact that we conducted our research in a real situation may enable academics and practitioners to understand the effects of information services more clearly. Finally, since our study involved three different types of information service which are most frequently applied in recent years, the results from our study might provide operational guidelines to the companies that are delivering their customers information by multi-channel. In other words, since we found that, in terms of customer loyalty, the key areas would be different from each other according to the types of information services, our analysis would help to make decisions such as selecting strengthening points or allocating resources by information service channels.

Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship (함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향)

  • Hyun, Kwang-Chul;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF

A Study on the standardization of ETCS (Focused on RF) (자동요금징수시스템(ETCS) 표준화 연구(주파수방식을 중심으로))

  • Kwon, Han-Joon;Lee, Ki-Hyun;Kim, Yong-Deak
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.3
    • /
    • pp.62-73
    • /
    • 2008
  • In this paper, domestic standard revision plan of dynamic frequency method which is used both in unmanned automatic toll collection system and manned collection system of the express highway is presented. For such ETCS, the infrared rays (870 nm) of active frequency method and the frequency integrated method (5.8 GHz) are adopted and extended to be operated to the all around the Toll Gate. This standardization plan is based on inter connection reference model between OSI (Open System Interconnection) in process of ITS short range radio communication standardization of 5.8 GHz bandwidth to support traffic information and control system service, and the derived revision plan by starting from physical layer which support interoperability for multiple access between RSE (Road Side Equipment) and OBE (On Board Equipment), in which is categorized into physical layer, data link layer, and application layer. In case of radiation power, existing standard is divided by class1 (within 10 m) and Class2 (within 100 m) according to transmission lengthwhile it is operated with just single standard 'Class1' because of notification of Ministry of Information and Communication in 2004. In the case of the limitation value of incident power in communication area, considering operation plan of ETCS that is on actuality operation the measurements are reflected to the standard. In other wort this paper proposed the improvement standard of incident power, pseudo response in the communication area and radiated power in order to secure stability and compatibility among operator systems about the needed part on ETCS operation.

  • PDF