• 제목/요약/키워드: multiple measurements

검색결과 803건 처리시간 0.025초

전방 모노카메라 기반 SLAM 을 위한 다양한 특징점 초기화 알고리즘의 성능 시뮬레이션 (Performance Simulation of Various Feature-Initialization Algorithms for Forward-Viewing Mono-Camera-Based SLAM)

  • 이훈;김철홍;이태재;조동일
    • 제어로봇시스템학회논문지
    • /
    • 제22권10호
    • /
    • pp.833-838
    • /
    • 2016
  • This paper presents a performance evaluation of various feature-initialization algorithms for forward-viewing mono-camera based simultaneous localization and mapping (SLAM), specifically in indoor environments. For mono-camera based SLAM, the position of feature points cannot be known from a single view; therefore, it should be estimated from a feature initialization method using multiple viewpoint measurements. The accuracy of the feature initialization method directly affects the accuracy of the SLAM system. In this study, four different feature initialization algorithms are evaluated in simulations, including linear triangulation; depth parameterized, linear triangulation; weighted nearest point triangulation; and particle filter based depth estimation algorithms. In the simulation, the virtual feature positions are estimated when the virtual robot, containing a virtual forward-viewing mono-camera, moves forward. The results show that the linear triangulation method provides the best results in terms of feature-position estimation accuracy and computational speed.

Properties of ZnO:Al Films Prepared by Spin Coating of Aged Precursor Solution

  • Shrestha, Shankar Prasad;Ghimire, Rishi;Nakarmi, Jeevan Jyoti;Kim, Young-Sung;Shrestha, Sabita;Park, Chong-Yun;Boo, Jin-Hyo
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권1호
    • /
    • pp.112-115
    • /
    • 2010
  • Transparent conducting undoped and Al impurity doped ZnO films were deposited on glass substrate by spin coat technique using 24 days aged ZnO precursor solution with solution of ethanol and diethanolamine. The films were characterized by UV-Visible spectroscopy, X-ray diffraction (XRD), scanning electron microscope (SEM), electrical resistivity ($\rho$), carrier concentration (n), and hall mobility ($\mu$) measurements. XRD data show that the deposited film shows polycrystalline nature with hexagonal wurtzite structure with preferential orientation along (002) crystal plane. The SEM images show that surface morphology, porosity and grain sizes are affected by doping concentration. The Al doped samples show high transmittance and better resistivity. With increasing Al concentration only mild change in optical band gap is observed. Optical properties are not affected by aging of parent solution. A lowest resistivity ($8.5 \times 10^{-2}$ ohm cm) is observed at 2 atomic percent (at.%) Al. With further increase in Al concentration, the resistivity started to increase significantly. The decrease resistivity with increasing Al concentration can be attributed to increase in both carrier concentration and hall mobility.

뇌졸중 환자의 앉은 자세에서 일어서기 동작 수행에 영향을 주는 다리 근 활성 비교 (A Comparison of Lower Limb Muscle Activity Affecting Sit-to-Stand Movement of Stroke Patients)

  • 박인석;주성광
    • PNF and Movement
    • /
    • 제16권1호
    • /
    • pp.59-66
    • /
    • 2018
  • Purpose: This study aimed (1) to identify asymmetry observed in electromyography (EMG) activity patterns of lower limb muscles between affected and unaffected sides of stroke patients during sit to stand (STS) movement and (2) to identify the muscles of the paretic lower limb that affected STS performance in stroke patients. Methods: This study consisted of 27 patients (15 males and 12 females) with poststroke hemiparesis. The activation of the rectus femoris (RF), tibialis anterior (TA), and gastrocnemius (GCM) of the affected side and unaffected side during STS movement were recorded using surface EMG. In addition, EMG lower limb muscle activation patterns were measured in the all section, pre-thigh off (pre-TO), and post-thigh off (post-TO) section. All measurements were obtained during five repetitions of the STS (FTSTS) movement. An independent t-test was performed to compare the affected side and unaffected side of the lower limb during the STS movement. A stepwise linear regression analysis was conducted to identify the muscles that affected STS performance. Results: Activation of both the RF and TA significantly affected the lower limb during the STS movement (p<0.05). Two muscles showed a difference on the post-TO section. The results of the stepwise multiple regression analysis showed that the RF and TA muscles of the affected lower limb were affected in FTSTS. Conclusion: These results provide a basis for reinforcement training, focusing on the RF and TA muscles of the affected side of stroke patients to improve asymmetric movement and performance in STS movement.

분절형 PC침목의 안전성 확보를 위한 성능평가 시험 (Performance Measurement of Split PC Sleepers for Safety in Maintenance Work)

  • 엄기영;엄주환;신승권;이창훈
    • 한국방재학회 논문집
    • /
    • 제6권4호통권23호
    • /
    • pp.1-6
    • /
    • 2006
  • 세계적으로 기존선 속도향상을 위해 분기기 개량 연구가 진행되어 왔다. 분기기는 선로시스템에서 구조적으로 가장 복잡한 장치로써 안정적인 구조가 필요하다. 이에 분기기 부설시 정확한 조립은 승차감과 열차주행 안전성에 크게 영향을 끼친다. 이러한 문제점 해결을 위해 최근 철도 선진국에서는 분절 PC침목을 이용한 공장에서의 사전 일체화 정밀조립 후 현장까지 운반한다. 본 연구에서는 우리나라에서 처음으로 도입된 분절형 PC침목의 안전성 평가를 위해 실내 성능평가시험을 실시하였다. 시험조건으로 현장에서 STT, MTT와 같은 유지보수 작업시 발행 가능한 최악의 조건을 고려하여 분절침목의 구조적 안전성을 검토하였다.

뇌졸중 환자의 재활참여가 기능회복에 미치는 영향 (Impact of Patients' Level of Participation in Rehabilitation on Functional Outcome in Patients With Stroke)

  • 원종임
    • 한국전문물리치료학회지
    • /
    • 제27권1호
    • /
    • pp.63-69
    • /
    • 2020
  • Background: Stroke recovery is a long and complex process. Successful stroke recovery seems to be strongly associated with patients' high motivation and committed participation. Patients' motivation is a key determinant of successful rehabilitation outcomes, but it is difficult in defining and measuring. Patients' participation is defined as the degree or extent to which subjects take part in rehabilitation activities and can be measured by observable behavior. Objects: The purpose of this study was to investigate the impact of patients' level of participation in rehabilitation on functional outcomes in patients with stroke. Methods: Forty post-stroke inpatients participated in this study. The level of rehabilitation participation was measured by the Hopkins Rehabilitation Engagement Rating Scale (HRERS). Other measures used for the evaluation were the Rivermead Mobility Index (RMI) and Korean version of the Modified Barthel Index (K-MBI). Overall measurements were made at early intervention and late intervention. Spearman correlation and multiple regression were used to measure the relationships between HRERS, RMI, and K-MBI. Results: The correlation found between HRERS total scores at early intervention and RMI total scores of late intervention was above moderate (r = 0.607, p < 0.01). RMI total scores at early intervention (p < 0.000), HRERS total scores at early intervention (p < 0.001), and disease duration (p < 0.003) were significant predictors of RMI total scores at late intervention. Conclusion: The level of participation at early intervention was associated with improvement in mobility. The level of mobility at early intervention, disease duration, and patients' participation at early intervention were important determinants of functional outcome. These findings suggest that patients' participation should be encouraged in order to achieve successful stroke recovery.

Tacrolimus의 혈중농도측정법 비교 및 간이식환자에서의 집단 약동학 (Comparison of Analytical Methods of Tacrolimus in Plasma and Population Pharmacokinetics in Liver Transplant Recipients)

  • 김은영;강원구;곽혜선
    • 한국임상약학회지
    • /
    • 제18권1호
    • /
    • pp.60-67
    • /
    • 2008
  • This study aimed to compare a microparticle enzyme immunoassay (MEIA) with a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for the measurement of tacrolimus concentrations in adult liver transplant recipients, to investigate how the assay choice influenced the population pharmacokinetics of tacrolimus and to identify patient characteristics that affected pharmacokinetic parameters in each assay. Tacrolimus concentrations from 29 liver (n=52 paired-samples) transplant recipients measured by both MEIA and LC/MS/MS were used to evaluate the performance of these methods in the clinical setting. Tacrolimus pharmacokinetics was studied independently using MEIA and LC/MS/MS data in 70 adult patients using a population approach performed with NONMEM. Patient characteristics which influenced pharmacokinetic parameters in each assay were compared. The relation between LC/MS/MS and MEIA measurements was best described by the regression equation MEIA=1.465*LC/MS/MS-1.336 (r=0.91). Multiple linear regression analysis showed significant inverse relationships between assay difference and hematocrit (Hct) (p<0.025) in liver graft recipients. In MEIA, the population estimate of tacrolimus CL/F and apparent volume of distribution (Vd/F) were found to be 10.1 L/h and 226 L, and in LC/MS/MS, 13 L/h and 305 L respectively. Neither patient's age, weight, gender, grafted hepatic weight, albumin concentration, nor markers of liver function influenced tacrolimus CL/F The final model of CL/F was found to be 10.1+(Hct/Hct mean)$^{12.0}$ in MEIA and 13+(1+Hct/578) in LC/MS/MS indicating that CL/F was influenced by hematocrit.

  • PDF

상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향 (Effect of the slice thickness and the size of region of interest on CT number)

  • 이지연;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권2호
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

간호 대학생의 의료관련감염 관리에 대한 표준주의 인지도와 표준주의 수행도: 내적 건강통제위의 매개효과 (Awareness and Performance on Standard Precautions of Hospital-acquired Infection Control in Nursing Students: The Mediating Effect of Internal Health Locus of Control)

  • 양선이;임효남
    • 한국간호교육학회지
    • /
    • 제23권4호
    • /
    • pp.378-388
    • /
    • 2017
  • Purpose: The aim of this study was to identify the status of performance on standard precautions among nursing students and to examine the mediating effects of internal health locus of control on the relationship between awareness and performance on standard precautions of hospital-acquired infection control. Methods: The participants in this study were 134 nursing students. The measurements included a standard precautions awareness and performance scale, and a multidimensional health locus of control scale. Data were analyzed using independent t-test, one-way ANOVA, $Scheff{\acute{e}}$ test, Pearson correlation coefficient, and simple and multiple regression techniques. Mediation analysis was performed by the Baron and Kenny's method and Sobel test. Results: The mean score of standard awareness, standard performance, and internal health locus of control about standard precaution were $174.30{\pm}9.08$; $169.48{\pm}12.04$; and $20.43{\pm}2.82$; respectively. There was a positive correlation between standard awareness and performance (r=.414, p<.001). Also, standard awareness was significantly correlated with internal health locus of control (r=.413, p=.014). Internal health locus of control showed partial mediating effects in the relationship between awareness and performance. Conclusion: The results indicate a need to improve the internal health locus of control of nursing students. Therefore, an internal health locus of control improvement program should improve performance on standard precautions for patients and themselves.

GaN 기반 LED구조의 p-GaN층 성장온도에 따른 광학적, 결정학적 특성 평가 (Optical and microstructural behaviors in the GaN-based LEDs structures with the p-GaN layers grown at different growth temperatures)

  • 공보현;김동찬;김영이;한원석;안철현;최미경;조형균;이주영;김홍승
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.144-144
    • /
    • 2008
  • Blue light emitting diode structures consisting of the InGaN/GaN multiple quantum wells were grown by metalorganic chemical vapor deposition at different growth temperatures for the p-GaN contact layers and the influence of growth temperature on the emission and microstructural properties was investigated. The I-V and electroluminescence measurements showed that the sample with a p-GaN layer grown at $1084^{\circ}C$ had a lower electrical turn-on voltage and series resistance, andenhanced output power despite the low photoluminescence intensity. Transmission electron microscopy (TEM) revealed that the intense electro luminescence was due to the formation of a p-GaN layer with an even distribution of Mg dopants, which was confirmed by TEM image contrast and strain evaluations. These results suggest that the growth temperature should be optimized carefully to ensurethe homogeneous distribution of Mg as well as the total Mg contents in the growth of the p-type layer.

  • PDF