• Title/Summary/Keyword: multiple CT images

Search Result 60, Processing Time 0.026 seconds

A Design and Implementation of Image Maintenance Using Base on Grid of the Decentralized Storage System (GRID 기반의 분산형 의료영상 저장시스템 설계 및 구현)

  • Kim, Sun-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Modern hospitals have been greatly facilitated with information technology (IT) such as hospital information system (HIS). One of the most prominent achievements is medical imaging and image data management so-called Picture Archiving and Communication Systems (PACS). Due to inevitable use of diagnostic images (such as X-ray, CT, MRI), PACS made tremendous impact not only on radiology department but also nearly all clinical departments for exchange and sharing image related clinical information. There is no doubt that better use of PACS leads to highly efficient clinical administration and hospital management. However, due to rapid and widespread acceptance of PACS storage and management of digitized image data in hospital introduces overhead and bottleneck when transferring images among clinical departments within and/or across hospitals. Despite numerous technical difficulties, financing for installing PACS is a major hindrance to overcome. In addition, a mirroring or a clustering backup can be used to maximize security and efficiency, which may not be considered as cost-effective approach because of extra hardware expenses. In this study therefore we have developed a new based on grid of distributed PACS in order to balance between the cost and network performance among multiple hospitals.

  • PDF

Diffuse Hemangiomatosis in the Intra-Abdominal Cavity Mimicking Peritoneal Metastasis: A Case Report (복강 내 전이와 유사한 복강 내 생긴 해면 혈관종증: 증례 보고)

  • Won Ik Ahn;Ji Yeol Shin;Ju Wan Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1182-1188
    • /
    • 2022
  • We call hemangiomatosis if hemangioma arises multifocally from single or multiple organs. It develops predominantly on liver, and there are just few cases of hemangiomatosis from greater omentum and mesentery. Herein, we present the imaging and histopathological findings including CT and MRI images of a 62-year-old male patient with a hemangiomatosis on liver, greater omentum and mesentery.

Usability of 2D/2D Match for Image Guided Radiotherapy (IGRT) of Prostate Cancer with Fiducial Markers (전립선 암 환자의 영상유도 방사선 치료 시 Fiducial Marker를 이용한 2D/2D Match의 유용성에 대한 연구)

  • Bae, Sun-Myung;Yang, Oh-Nam;Song, Heung-Kwon;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: To study the efficacy of marker match with using kilovoltage (KV) X-ray among multiple image guidance that referring tree fiducial marker in radiation therapy for prostate cancer patients. Materials and Methods: KV two-dimantional images (anterior-posterior, right-left) and cone-beam CT volumetric images were acquired after setup for patients with three fiducial markers. Compare the position of the fiducial marker of reference plan computed tomography (CT) and of KV, CBCT images; then decide the shift score of X, Y, and Z. This study executed 5 times on 10 patients and analyzed the shift value. Results: In the radiation therapy using fiducial marker, The function of marker match showed the same direction tendency as the CBCT, and showed X, Y, Z difference of about 0.6, 0.7, and 0.8 (unit: mm). Conclusion: Comparing to this, the result of shift value using 2D marker match showed less than 1.0 mm difference. The function of marker match is considered more useful in time-wise and effective dose rather than CBCT. Therefore, Both methods are used to treat patients for prostate cancer.

  • PDF

Clinical Investigation of Pediatric Blunt Thoracic Trauma (소아 흉부 둔상 환자의 임상적 고찰)

  • Chung, Tae Kyo;Hyun, Sung Youl;Kim, Jin Joo;Ryoo, EeIl;Lee, Kun;Cho, Jin Seung;Hwang, Sung Yun;Lee, Suk Ki
    • Journal of Trauma and Injury
    • /
    • v.18 no.2
    • /
    • pp.119-126
    • /
    • 2005
  • Background: Blunt thoracic trauma in children has a high morbidity and mortality. In this study, we assessed the significance of the injury pattern, mechanism and initial status in emergency department on severity and prognosis in pediatric blunt thoracic trauma patients. Method: We retrospectively reviewed medical records and chest X-ray and CT images of 111 pediatric blunt thoracic trauma patients from October 2000 to June 2005. Data recorded age, gender, season, injury mechanism, injury pattern, associated injury, length of hospital stay and cause of death. Result: Of all 111 patients, 68 patients were injured by motor vehicle accidents, 30 were falls, 5 were motorcycle accidents, 3 were sports accidents and 5 were miscellaneous. In thoracic trauma, single injury of lung contusion were 35 patients and 32 patients had multiple thoracic injuries. Hospital stay in school age group were longer than preschool age group. The causes of death were brain injury in 9, respiratory distress in 4, and hypovolemic shock in 2 patients. Emergently transfused and mechanically ventilated patients had higher mortality rates than other patients. Patients required emergency operation and patients with multiple thoracic injuries had higher mortality rates. Conclusion: In this study, patients with combined injury, emergency transfusion, mechanical ventilation, emergency operation, multiple injuries in chest X-ray had higher mortality rates. Therefore in these pediatric blunt thoracic trauma patients, accurate initial diagnosis and proper management is required.

Volume measurement of limb edema using three dimensional registration method of depth images based on plane detection (깊이 영상의 평면 검출 기반 3차원 정합 기법을 이용한 상지 부종의 부피 측정 기술)

  • Lee, Wonhee;Kim, Kwang Gi;Chung, Seung Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.818-828
    • /
    • 2014
  • After emerging of Microsoft Kinect, the interest in three-dimensional (3D) depth image was significantly increased. Depth image data of an object can be converted to 3D coordinates by simple arithmetic calculation and then can be reconstructed as a 3D model on computer. However, because the surface coordinates can be acquired only from the front area facing Kinect, total solid which has a closed surface cannot be reconstructed. In this paper, 3D registration method for multiple Kinects was suggested, in which surface information from each Kinect was simultaneously collected and registered in real time to build 3D total solid. To unify relative coordinate system used by each Kinect, 3D perspective transform was adopted. Also, to detect control points which are necessary to generate transformation matrix, 3D randomized Hough transform was used. Once transform matrices were generated, real time 3D reconstruction of various objects was possible. To verify the usefulness of suggested method, human arms were 3D reconstructed and the volumes of them were measured by using four Kinects. This volume measuring system was developed to monitor the level of lymphedema of patients after cancer treatment and the measurement difference with medical CT was lower than 5%, expected CT reconstruction error.

Minute Pulmonary Meningothelial-Like Nodules Simulating Hematogenous Lung Metastasis: A Case Report

  • Lee, Sang Kook;Kim, Gi Jeong;Kim, Young Jae;Leem, Ah Young;Hwang, Eu Dong;Kim, Se Kyu;Chang, Joon;Kang, Young Ae;Kim, Song Yee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.2
    • /
    • pp.67-70
    • /
    • 2013
  • A 52-year-old man was referred to our clinic for an 11.3 mm nodule in the left lower lobe that was discovered on a chest computed tomography (CT) scan. Eleven small nodules were subsequently found in both lungs. Initially, we performed a transthoracic needle aspiration using CT scan guidance. The pathologic report showed a few clusters of atypical cells that were suspicious for malignancy. The positron emission tomography images revealed multiple lung nodules scattered throughout both lungs. The largest nodule (11.3 mm) in the left lower lobe did not have any discernible fludeoxyglucose uptake. For pathologic confirmation, we consulted a thoracic surgeon to perform the video-assisted thoracoscopic surgery. The final diagnosis was minute pulmonary meningothelial-like nodules (MPMNs). MPMNs are benign in nature, and only a few cases require treatment. However, when clinicians are suspicious of potential malignancy, a pathological correlation is essential, even if the final diagnosis is MPMNs.

Generation Method of 3D Human Body Level-of-Detail Model for Virtual Reality Device using Tomographic Image (가상현실 장비를 위한 단층 촬영 영상 기반 3차원 인체 상세단계 모델 생성 기법)

  • Wi, Woochan;Heo, Yeonjin;Lee, Seongjun;Kim, Jion;Shin, Byeong-Seok;Kwon, Koojoo
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.4
    • /
    • pp.40-50
    • /
    • 2019
  • In recent years, it is important to visualize an accurate human body model for the low-end system in the medical imaging field where augmented reality technology and virtual reality technology are used. Decreasing the geometry of a model causes a difference from the original shape and considers the difference as an error. So, the error should be minimized while reducing geometry. In this study, the organ areas of a human body in the tomographic images such as CT or MRI is segmented and 3D geometric model is generated, thereby implementing the reconstruction method of multiple resolution level-of-detail model. In the experiment, a virtual reality platform was constructed to verify the shape of the reconstructed model, targeting the spine area. The 3D human body model and patient information can be verified using the virtual reality platform.

Volume difference in upper central incisor preparation according to the changes of restorative design and marginal location (상악 중절치 삭제 시 수복 디자인과 변연부 위치에 따른 부피 변화)

  • Kim, Chong-Hyun;Park, Young-Bum;Kim, Sung-Tae;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the volumetric change of teeth after preparation for various designs and margin locations through Micro CT analysis (Skyscan 1076: SKYSCAN, Konitch, Belgium). Materials and methods: The 36 artificial teeth were used to determine reduction volume of upper central incisor. According to the restorative design these 36 teeth were divided into 4 groups and according to the marginal location each group was divided into 3 subgroups. The volume of unprepared teeth was obtained by using Micro CT and the volume of prepared teeth was obtained in the same method. The CT scanned images before and after preparation were superimposed. Results: The volume difference was significantly increased as follows: traditional laminate veneer < full laminate veneer < all ceramic crown < metal ceramic crown. One-way ANOVA and Tukey multiple comparison analyses were used to analyze the data in this study. In each group the volume difference was significantly increased as follows: 1 mm above CEJ < CEJ < 1 mm below CEJ (P<.05). The % volume difference of all ceramic crown and metal ceramic crown was 31 - 48% and that of laminate veneer was 14 - 30%. The volume difference of the traditional laminate veneer was 1/3 of that of metal ceramic crown. The full laminate (1 mm below CEJ) and all ceramic crown (1 mm above CEJ) showed a similar volume difference. Metal ceramic crown showed 13.7% more volume difference than all ceramic crown. Conclusion: There exists the difference in volumetric change according to designs of restoration and margin locations of preparation.

A NEW MEASUREMENT METHOD OF FEMORAL ANTEVERSION BASED ON THREE DIMENSIONAL MODELING (3차원 모델링을 이용한 대퇴 전염각의 측정)

  • Kim, June-S.;Park, Hee-J.;Choi, Kwang-S.;Choi, Kui-W.;Kim, Sun-I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.141-144
    • /
    • 1997
  • Femoral neck anteversion is the angle between the neck and the knee axis projected on a plane perpendicular to the longitudinal axis. Conventional methods that use cross-sectional Computed Tomography(CT) images to estimate femoral anteversion have several problems because of the complex 3D structure of the femur. These are the ambiguity of defining the longitudinal axis, the femoral neck axis and condylar line, and the dependence on patient positioning. Especially the femoral neck axis that is known as a major source of error is hard to determine from a single or multiple 2D transverse images. So we developed a new method for measuring femoral anteversion by 3D modeling method. In this method, femoral head is modeled as a sphere. The center of femoral neck is the mid-point of the 2D reconstructed oblique image in the femoral neck part. Then neck axis is a line connecting foregoing two centers. We model the longitude of femur as a cylinder, and the long axis is defined from the fitted cylinder. The knee axis which is tangent to the back of the femoral condyles is easily determined by table-top method. By the definition of femoral anteversion, the femoral anteversion is easily calculated from this model.

  • PDF

Genetic Algorithm based B-spline Fitting for Contour Extraction from a Sequence of Images (연속 영상에서의 경계추출을 위한 유전자 알고리즘 기반의 B-spline 적합)

  • Heo Hoon;Lee JeongHeon;Chae OkSam
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.5
    • /
    • pp.357-365
    • /
    • 2005
  • We present a B-spline fitting method based on genetic algorithm for the extraction of object contours from the complex image sequence, where objects with similar shape and intensity are adjacent each other. The proposed algorithm solves common malfitting problem of the existing B-spline fitting methods including snakes. Classical snake algorithms have not been successful in such an image sequence due to the difficulty in initialization and existence of multiple extrema. We propose a B-spline fitting method using a genetic algorithm with a new initial population generation and fitting function, that are designed to take advantage of the contour of the previous slice. The test results show that the proposed method extracts contour of individual object successfully from the complex image sequence. We validate the algorithm by false-positive/negative errors and relative amounts of agreements.