• 제목/요약/키워드: multichannel system

검색결과 192건 처리시간 0.021초

An Implementation of Acoustic-based MAC Protocol Multichannel Underwater Communication Network

  • Lim, Yong-Kon;Park, Jong-Won;Kim, Chun-Suk;Lee, Young-Chul
    • 한국정보통신학회논문지
    • /
    • 제1권1호
    • /
    • pp.105-111
    • /
    • 1997
  • This Paper Proposes a new efficient system design strategies for the acoustic-based underwater multiple modem and media access control protocol. The system aims to establish the acoustic-based communication network of an underwater vehicles for deep sea mining, which ensures a certain level of maximum throughput regardless of the propagation delay of acoustic and allows fast data transmission through the acoustic-based multiple channel. A media access control protocol for integrated communication network and it's acoustic-based communication modems that allows 'peer-to-peer' communication between a surface mining plant multiple underwater system is designed, and the proposed media access control protocol is implemented for its verification. Furthermore, a proposed design strategies which make it possible to control the multiple vehicle for an underwater mining is presented in this paper.

  • PDF

다중 채널 EEG신호 자동 해석에 관한 연구 (A Study on the Automated Analysis of Multichannel EEG Signal)

  • 조재희;장태규;양원영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.293-295
    • /
    • 1992
  • This Paper presents the design of an automated EEG analyzing system. The design considerations including processing speed, A/D conversion, filtering, and waveforms detection, are overviewed with the description of the associated EEG charateristics. The architecture of the currently implemented system consists of a -controller based front-end signal processing unit and a host computer system. The data acquisition procedures are described along with a couple of illustrations of the acquired EEG/EOG signal.

  • PDF

지구통계기법과 표면파 다중채널분석을 이용한 포항 지반의 SPT-N value 교차검증 (Cross-Validation of SPT-N Values in Pohang Ground Using Geostatistics and Surface Wave Multi-Channel Analysis)

  • 김경오;한희수
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.393-405
    • /
    • 2020
  • 지반 및 기초의 안정성 평가, 지진의 액상화 평가 등을 위해서 지반강도 및 지하수 높이 등 다양한 지반정보가 필요하다. 대한민국에서 행해지는 표준관입시험(Standard Penetration Test, SPT) 결과는 국토지반정보포털시스템에 등록하게 되어있다. 비시추지역의 지반정보가 필요할 경우, 지구통계기법(Geostatistics)들을 응용할 수 있다. 본 논문은 경험적 베이지안 크리깅(Empirical Bayesian Kriging, EBK)과 역거리 가중치법(Inverse Distance Weighting Method, IDWM)을 이용하여 비시추지역의 지반정보를 구할 경우의 타당성에 관한 것이다. 이 기법들을 이용하기 위해 공간 보간에 범용적으로 적용되는 Esri사의 ArcGIS Pro 프로그램을 사용하였다. 본 해석에 사용된 지구통계기법들의 정확성을 검토하기 위하여, 표준관입시험에서 구한 시추지역 지반의 강도 정수 및 지하수의 높이를 해석기법의 결과와 교차 검증하였다. 또한, 지구물리학적 기법인 표면파 다중채널분석(Multichannel Analysis of Surface Waves, MASW)조사를 추가 수행하여, 본 해석에 사용된 기법들을 재검증하였다. 포항 북구 지역을 1.0km×1.0km로 분할하여 총 111개의 구역으로 분할하였으며, 경험적 베이지안 크리깅(EBK) 및 역거리 가중치법(IDWM)을 통한 표준관입시험치 및 지하수위에 대한 교차검증을 수행한 결과, 두 기법 모두 적합한 것으로 나타났다. 표면파 다중채널분석(MASW)은 대략적인 구간 영역을 제시하여, SPT N값의 분포양상과 지하수위를 명확히 파악하기 곤란하였다.

QR 분해와 채널 분해법을 이용한 비선형 격자 알고리듬 (Nonlinear Lattice Algorithms using QRD and Channel Decomposition)

  • 안봉만;백흥기
    • 전자공학회논문지B
    • /
    • 제32B권10호
    • /
    • pp.1326-1337
    • /
    • 1995
  • In this paper, we transformed the bilinear filter into an equivalent linear multichannel filter and derived QR decomposition based recursive least squares algorithms for bilinear lattice filters. We also defined order update relation of the forward and the backward input vectors by using the channel decomposition. The forward and the backward data matrices were defined by using the forward and the backward input vectors and orthogonalized with the QR decomposition. we can obtain the lattice equations of the bilinear filters by using the channel decomposition. we can be derived the lattice equations of the bilinear filters using this decomposition process which are the same as the lattice equations derived by Baik, we can use the coefficient transformation algorithm proposed by Baik. We derived the equation error and the output error algorithm of the QRD based RLS bilinear lattice algorithm. Also, we evaluated the performance of the proposed algorithms through the system identification of the bilinear system.

  • PDF

수중 초음파 다중통신 네트워크를 위한 MAC 프로토콜에 관한 연구 (A Study on the Mac Protocol for Multichannel Network Underwater Acoustic Communication)

  • 김천석
    • 한국전자통신학회논문지
    • /
    • 제1권1호
    • /
    • pp.42-48
    • /
    • 2006
  • 본 논문에서는 해저의 이동체 사이의 효과적인 다중 초음파 데이타 통신을 위한다중 초음파 접속제어 프로토콜을 제안 하였다. 논리계층에서의 프로토콜은 모선과 수중 이동체간에 다중 채널 통신이 가능하고 논리계층간의 peer to peer 통신이 가능함을 확인하였다. 본 논문에서 제안된 접속제어 프로토콜은 수중 통신 시스템의 여러 가지 수중 물리적 환경에서 전파지연 시간에 무관하게 최대 수율을 보장하고 서로 다른 주파수 대역을 사용하는 다중 전송채널을 이용하여 수중에서 고속 데이터 전송의 가능함을 확인하였다.

  • PDF

범용 DSP를 이용한 MPEG-2 오디오 부호화기의 성능 개선 (An Enhancement of the MPEG-2 Audio Encoder Using General DSPs)

  • 오현오;김성윤;윤대희;차일환;이준용
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1997년도 학술대회
    • /
    • pp.63-67
    • /
    • 1997
  • The ISO(International Standard Organization) has standardized MPEG-2 audio. The MPEG-2 audio compression algorithm is based upon subband analysis and exploits the human auditory characteristics to achieve a low bit rate with minimum perceptual loss of audio signal quality. This thesis presents an enhanced MPEG-2 audio encoder using multiple TMS320C30 general purpose DSP's. The developed system is made up of five slave boards and one master board. Each slave board performs susband analysis psychoacoustic parameter calculation for one channel, and the master board manages bit allocation, quantization, and bit-stream formatting for all channels. Parallel processing and pipelining techniques are used in hardware structure and fast algorithms are applied in each subroutine to implement a real-time process. The implemented system supports multichannel up to 5.1 and various bitrates.

  • PDF

Microprocessor Based Laser Induced Fluorometry I. Development of System and Application to Liquid Chromatography

  • Kim, Ha-Suck;Park, Chan-Seung;Hwang, Eui-Jin;Chol, Q.-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제5권6호
    • /
    • pp.253-259
    • /
    • 1984
  • An analytical applicability of the fluorescence detection with an optical multichannel analyzer to organic dyes was studied in this work. Continuous acquisition of spectra was possible with the use of a microcomputer. The maximum acquisition rate of a spetrum with 70-point average was about 3 seconds. Floppy discs were used to store data for later use in processing. Laser induced fluorescence detector in High Performance Liquid Chromatography was chosen for an application. Fluorescein below $10^{-15}g$ was detected satisfactorily using this system. With the help of microcomputer, three dimensional chromatograms of time-wavelength-intensity were obtained.

Partial Principal Component Elimination Method and Extended Temporal Decorrelation Method for the Exclusion of Spontaneous Neuromagnetic Fields in the Multichannel SQUID Magnetoencephalography

  • Kim, Kiwoon;Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kang, Chan-Seok;Kim, In-Seon;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.114-120
    • /
    • 2003
  • We employed a method eliminating a temporally partial principal component (PC) of multichannel-recorded neuromagnetic fields for excluding spatially correlated noises from event-evoked signals. The noises in magnetoencephalography (MEG) are considered to be mainly spontaneous neuromagnetic fields which are spatially correlated. In conventional MEG experiments, the amplitude of the spontaneous neuromagnetic field is much lager than that of the evoked signal and the synchronized characteristics of the correlated rhythmic noise makes it possible for us to extract the correlation noises from the evoked signal by means of the general PC analysis. However, the whole-time PC of the fields still contains a little projection component of the evoked signal and the elimination of the PC results in the distortion of the evoked signal. Especially, the distortion will not be negligible when the amplitude of the evoked signal is relatively large or when the evoked signals have a spatially-asymmetrical distribution which does not cancel out the corresponding elements of the covariance matrix. In the period of prestimulus, there are only the spontaneous fields and we can find the pure noise PC that is not including the evoked signal. Besides that, we propose a method, called the extended temporal decorrelation method (ETDM), to suppress the distortion of the noise PC from remanent evoked signal components. In this study, we applied the Partial Principal component elimination method (PPCE) and ETDM to simulated signals and the auditory evoked signals that had been obtained with our homemade 37-channel magnetometer-based SQUID system. We demonstrate here that PPCE and ETDM reduce the number of epochs required in averaging to about half of that required in conventional averaging.

  • PDF

허혈에 의한 다채널 심자도의 ST-T 변화 (ST-T Changes of Multichannel Magnetocardiographic Pattern in Myocardial Ischemia)

  • 권혁찬;김기웅;이용호;김진목;임현균;박용기;정남식;고영국;정보영;김진배;조정래
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.35-39
    • /
    • 2007
  • Myocardial ischemia causes heterogeneity of ventricular repolarization and sometimes produces changes of the ST-T wave in ECG. Therefore, morphological changes of ST-T waveform in ECG have a clinical significance in diagnosing myocardial ischemia. In this study, we investigated the ST-T changes caused by myocardial ischemia in magnetocardiography (MCG). We analyzed MCG patterns of biphasic T, ST segment deviations from baseline, main current angle of $T_{peak}$ and $T_{peak}$ dispersion in 300 CAD patients without ST elevation in ECG, 122 symptomatic patients and 48 normal subjects. MCGs were recorded by multichannel SQUID system in a magnetically shielded room. As results, we found that appearances of the abnormality were strongly correlated with the severity of myocardial ischemia. Also we found that the percentage of the patients showing MCG changes were higher than those in ECG. These results show that morphological changes of ST-T waveform in MCG can be used as a marker of myocardial ischemia.

  • PDF

A Performance Assessment of Real-time Multichannel Audio Codec

  • Kim, Sunghan;Jang, Daeyoung;Hong, Jinwoo
    • The Journal of the Acoustical Society of Korea
    • /
    • 제16권3E호
    • /
    • pp.56-61
    • /
    • 1997
  • In this paper, we describe a real-time implementation of a multi-channel auido codec system that is based on the MPEG-1 audio algorithm. The major feature of this system is that it has a flexible multi-DSP system that can be adapted for various applications with using up to four TMS320C40 DSPs. The purpose of this paper is to present the problems of the system and is to describe the optimized methods to solve the problems in the view of hardware and software. Our audio codec is composed of an encoder an a decoder system and the bit rate of bitstream is up to 384 kbps. Fast input/output interfaces, DSP overloads, and inter-DSP communications methods with high speed are considered in multi-DSP H/W. Also, to run real-time in S/W, optimizing methods of algorithm are considered. After implementation of system, the subjective assessment method, and 'triple stimulus/hidden reference/double blind' that recommended by ITU-R TG10/3 is adopted for the quality of our system. All test items except one are awarded difference grades(diffgrade) better than 1-. Form the results, multi-channel audio system can be used for HDTV service.

  • PDF