• Title/Summary/Keyword: multi-unit

Search Result 1,328, Processing Time 0.024 seconds

The Changes of Housing Characteristics Occupied by Two or More Households from 1995-2005 in Korea

  • Cho, Jae-Soon;Kwak, In-Sook
    • International Journal of Human Ecology
    • /
    • v.9 no.1
    • /
    • pp.53-62
    • /
    • 2008
  • This paper examines the changes in housing characteristics occupied by two or more households from 1995-2005, as a replicated follow-up study done by the previous decade of 1985-1995. The data analyzed were based on the Population and Housing Census in 1995, 2000, and 2005 by the Korean National Statistical Office. Results showed decreasing trends in the percentages of housing units occupied by multi-households and of households sharing a housing unit, while the average number of households for a shared housing unit was increasing. Detached dwellings in dongs (neighborhood) including ordinarily single-family detached ones, mainly multi-family houses, were the most often shared with other households even in the trend of the decreasing number of the detached housing. Further research is suggested to focus on housing circumstances of households sharing a detached dwelling in Dongs by the type of detached dwellings.

Topology Optimization for End Plate of Fuel Cell Stack (연료전지스택 바깥판의 위상최적설계)

  • Choi, Woo-Seok;Oh, Sung-Jin;Kim, Sung-Jong;Hong, Byung-Sun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.456-461
    • /
    • 2003
  • A fuel cell is an electrochemical device in which the energy of a chemical reaction is converted directly into electricity. By combining hydrogen fuel with oxygen from air, electricity is formed, without combustion of any form. Water and heat are the only by-products when hydrogen is used as the fuel source. Fuel cell stack consists of multi-layered unit cells. A unit cell consists of MEA and bipolar plates. The end plate of fuel cell stack should give a uniform distributed pressure to multi unit cell layers so as to reduce the contact resistance and to prevent the leakage of reactant gases and the damage of multi layer components. The current end plate is redundantly large and heavy. It makes the power per unit volume reduced. Topology optimization of end plate is conducted for mass reduction and enhancement of bending rigidity. The evaluation of the current design and the recommendation for the future design is remarked.

  • PDF

Implementation of Security Policies of ONSU-MF(One Network Security Unit-Multi Function) and OSD-MD(One Security Device-Multi Defense) (ONSU-MF(One Network Security Unit-Multi Function)기법과 OSD-MD(One Security Device-Multi Defense)기법 기반의 보안정책 구현)

  • Seo, Woo-Seok;Lee, Gyn-An;Jun, Moon-Seog
    • The KIPS Transactions:PartC
    • /
    • v.18C no.5
    • /
    • pp.317-326
    • /
    • 2011
  • This study is meaningful in that it standardizes various security and defense policies and devices, newly defines characteristics of defense policies and defense techniques, and specify and report various kinds of security polities and devices in order for administrators or users to add and apply the policies when introducing new security policies including the implementation of existing network infra and applying additionally. Therefore, this study aims to divide the policies into ONSU-MF(One Network Security Unit-Multi Function) that classifies one network security device-based policies and OSD-MD(One Security Device-Multi Defense), which implements various security methods by using one security device, and suggest network security infra improvement mechanism through the standardization implementation technique integrating the two methods.

The Analysis of Space in the Multi-housing unit of the Winners in the German architectural competition since 1990 (최근 20년간 독일 공동주택설계경기 당선작의 단위세대 공간 구조 분석)

  • Cho, Ja-Yeon;Choi, Chan-Hwan
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.163-173
    • /
    • 2012
  • In this study, the spatial analysis of the multi-housing unit plans was investigated since 1990 for the winners at the architectural competition which was held nationwide in Germany. The investigation was carried out from January in 1990 to December in 2010. 201Unit plans were analyzed. Space syntax model is used as analyzing tool of the Unit plans. The results of the study indicate followings: 1) The interior spaces in 3LDK types and 4LDK types, ordered by high value of integration are; (1) corridor, (2) entrance hall, (3) living room, (4) dining room. 2) The value of integration for the kitchen is higher in L/DK type than in LD/K type, and that for the living room is higher in LD/K type than in L/DK type. The mean value of integration for L/DK type is higher than that for LD/K type. This means that traffic line efficiency of L/DK type is higher than that of LD/K type. 3) The value of integration for corridor and entrance hall is gradually lower in recent years. That is, the type of Unit plans are changing from corridor types to hall types.

  • PDF

Design of a Load/store Unit for ARM-SMI Microprocessors (ARM-SMI용 Load/store Unit(LSU) 설계)

  • 김재억;이용석
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1387-1390
    • /
    • 2003
  • The superscalar architecture shows limit in performance improvement recently. While, SMT(Simultaneous Multi-Threading) architecture is receiving remark. The purpose of SMT architecture is to improve the performance of superscalar microprocessors by executing multi threads at the same time. In this paper, a load/store unit(LSU) suitable for ARM-compatible SMT microprocessors is presented. This LSU supports load instructions and store instructions of ARM ISA. This LSU keeps away the degradation of SMT by cache miss.

  • PDF

Analysis of the steady state and transient characteristics of a multi-type refrigeration system (멀티형 냉동 시스템의 정상상태 및 과도응답 특성 해석)

  • Lee, Gil-Bong;Yoo, Keun-Joong;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.439-444
    • /
    • 2005
  • Steady state simulation and dynamic simulation were performed to analyze the operational characteristics of a multi-type refrigeration system, Fully distributed model was adopted to simulate the steady state and transient responses of the system. The main aim was to see the effect of one indoor unit on the other unit. Numerical simulations were carried out for various operation conditions of an indoor unit - secondary fluid inlet temperature, mass flow rate and expansion valve opening. The results showed that the inlet temperature and mass flow rate of the secondary fluid of one indoor unit had minor effect on the operation of the other unit. However, the opening of the expansion valve had significant effect on the performance of the other unit.

  • PDF

Study on the Operation Strategy of A Building with Multi-Complex Spaces (복합 공간 구성 건물의 공조구역 운영 전략에 따른 에너지부하 특성 연구)

  • Yook, In-Soo;Kim, Min-Hwan;Nam, Hyeon-Jin;Kim, Dong-Ho;Seol, Dong-Mun;Lee, Geon-Tae;Kim, Jin-Ho S.;Kim, Jae-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.108-113
    • /
    • 2009
  • Buildings with multi-complex spaces designed for architectural values and functional requirements give rise to technical challenges in terms of energy efficiency and thermal comfort. Since spaces in such buildings are connected with openings with geometrical complexity, it is hard to define zoning plan and to control heating/cooling loads effectively. This paper presents a case study on the evaluation of operation strategy for a building with multi-complex spaces using computer simulation. The modelling methodology and the results of the simulations are also described.

  • PDF

Analyzing the Weight of Assessment Criteria in Korea Green Building Certification System - Focused on Certification Standards for Multi-unit Apartment Projects - (국내 친환경 건축물 인증제도 평가항목의 중요도 분석 - 공동주택 인증심사기준 중심으로 -)

  • Choi, Yeo-Jin;Lhee, Sang-Choon
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.83-90
    • /
    • 2012
  • Over the world, social demands and concerns of energy and resource depletions and environmental conservation have resulted in many researches and applications on sustainable development and construction. In order to support these demands and concerns, international green building certification systems such as LEED(Leadership in Energy and Environmental Design) and BREEAM(Building Research Establishment Environmental Assessment Method) were developed. In Korea, the green building certification system was introduced in 2000 and widely applied to all types of new buildings in order to induce the diffusion of sustainable buildings on May, 2010. This paper investigates the importance of assessment criteria on multi-unit apartment projects among certification rating systems using the AHP(Analytic Hierarchy Process) method and suggests a new direction on certification assessment standards. For applying the AHP method, the survey of staffs in green building certification consulting companies and architectural design companies was conducted via e-mail. As a result, criteria like energy, indoor environment, land use, pollution control, and ecological environment among 9 main ones turned out important on assessing green building certification at multi-unit apartment projects, while criteria like water resource, transportation, maintenance management, and material and resource did relatively unimportant.

Analysis of Living Noise in a Multi-unit Dwelling using Acoustic Simulation

  • Yang, Ginam;Ann, Joon-suk;Kim, Daewon;Kim, Gwang-Hee;Shin, Yoonseok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.87-96
    • /
    • 2016
  • More than half of Korea's urban population currently lives in multi-unit dwellings. This particular residence structure inevitably positions the living spaces of residents in close proximity to one another. Because of this proximity, the sounds of a particular household will transfer to other residents' units creating conflict between tenants. Efforts to alleviate this problem have been made in both the public and private sector. A prominent method of noise analysis between living units has been to make an actual sound measurement and obtain qualitative measurements from questionnaires. Although this method has been most widely used, such analysis requires a large amount of human effort and time. In addition, the questionnaire method fails to provide the objective information needed to accurately assess the noise situation. To overcome the inadequacies of this previous method, this study seeks to evaluate the applicability of an acoustic simulation method. Three types of living noises were analyzed to assess the noise levels passed between multi-unit dwellings. The acoustic simulation method was found to be more economical, efficient, and adaptable in information processing. The results of this study can be further applied to design and control living-noise through procedures such as acoustic absorption or space redesign.

A Study on the Spatial Characteristics of the Multi-housing Units in Seoul and Kyung-gi Area - Focused on the Unit Size of over $165m^2$- (최근 분양된 수도권 공동주택 단위세대의 공간계획 특성에 관한 연구 - 전용면적 $165m^2$ 이상의 대형규모를 중심으로 -)

  • Kim, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.6
    • /
    • pp.116-124
    • /
    • 2007
  • The purpose of this study is to find out the spatial characteristics of the multi-housing units in Seoul and Kyung-gi area since 2006. Literature review and content analysis were used for this study and 82units of the big size over $165m^2$ were analyzed to review such design characteristics as spatial composition, layout and linkage. Through this study, the following conclusions have been reached; 1) Most unit plans had 4LDK and 3bath types including family room as a public space. This results shows that family-room and bathroom has recently become more important than number of rooms in multi-housing units planning. 2) Diversity of plan figures such as mass-mixing, mass-separation and polygons(L, V-type)was showed in most unit plan, breaking from the standardized forms of box types. 3) Intermediated spaces such as foyers and halls in entrance zone were planned and sub-entrance into kitchen were planned for the various types of circulation and work-efficiency. Cases had private space separated from public space, the dispersion of rooms with the increase of connection by corridors, L-DK meaning the living room isolated from the dining and kitchen, partially located living room for a view in area distribution. The spatial planning of master-zone mostly consists of the types of two-rooms and an entry into a foyer(library, dress-powder room, bathroom and master bedroom). This study has a significant meaning on grasping current trend in Korean multi-housing and to provide information for future direction on housing-unit design.