• 제목/요약/키워드: multi-story buildings

검색결과 120건 처리시간 0.021초

The Application of Resettable Device to Semi-Active Tuned Mass Damper Building Systems for Multi-level Seismic Hazard Mitigation

  • Chey, Min-Ho
    • Architectural research
    • /
    • 제14권3호
    • /
    • pp.99-108
    • /
    • 2012
  • An innovative multi-story Semi-Active Tuned Mass Damper (SATMD) building system is proposed to control seismic response of existing structures. The application of adding new stories as large tuned mass and semi-active (SA) resettable actuators as central features of the control scheme is derived. For the effective control of the structures, the optimal tuning parameters are considered for the large mass ratio, for which a previously proposed equation is used and the practical optimal stiffness is allocated to the actuator stiffness and rubber bearing stiffness. A two-degree-of freedom (2-DOF) model is adopted to verify the principal efficiency of the suggested structural control concept. The simulations for this study utilizes the three ground motions, from SAC project, having probability of exceedance of 50% in 50 years, 10% in 50 years, and 2% in 50 years for the Los Angeles region. 12-story moment resisting frames, which are modified as '12+2' and '12+4' story structures, are investigated to assess the viability and effectiveness of the system that aims to reduce the response of the buildings to earthquakes. The control ability of the SATMD scheme is compared to that of an uncontrolled and an ideal Passive Tuned Mass Damper (PTMD) building system. From the performance results of suggested '12+2' and '12+4' story retrofitting case studies, SATMD systems shows significant promise for application of structural control where extra stories might be added.

전단파괴모드를 고려한 철근콘크리트 보통전단벽-골조 건물의 붕괴메커니즘 (Collapse Mechanism of Ordinary RC Shear Wall-Frame Buildings Considering Shear Failure Mode)

  • 추유림;김태완
    • 한국지진공학회논문집
    • /
    • 제25권1호
    • /
    • pp.1-9
    • /
    • 2021
  • Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.

Effective number of mega-bracing, in order to minimize shear lag

  • Zahiri-Hashemi, Rouzbeh;Kheyroddin, Ali;Farhadi, Basir
    • Structural Engineering and Mechanics
    • /
    • 제48권2호
    • /
    • pp.173-193
    • /
    • 2013
  • In this paper, influence of geometric configurations of multi-story bracing on shear lag behaviour of braced tube structures is investigated. The shear lag of 24-, 36- and 72-story braced tube structures are assessed considering all possible configurations of overall X and Chevron bracing types. Based on the analytical results, empirical equations, useful for the preliminary design phase, are proposed to provide the optimum number of stories that braced, in order to exert minimum shear lag on structures. Studying the interaction behaviour of a tube and different bracing types along with paying attention to the shear lag behaviour, a better explanation about the reasons behind the efficiency of a specific bracing module in decreasing the shear lag is developed. The analytical results show that there are distinct differences between the anatomy of braced tube structures with X and Chevron bracing regarding the shear lag behaviour.

다층 공동주택의 중량충격원 전파 특성 해석 (Heavy-weight floor impact noise propagation in a multi-story building)

  • 이신엽;황덕영;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.225-226
    • /
    • 2014
  • In multi-story buildings, heavy-weight floor impact noise propagates through multiple layers. In order to evaluate the influence of structural vibration and propagation, the actual twelve-story building was excited by an impact ball. Sound and vibration responses of each floor was measured using accelerometers and a microphone. Vibration characteristics and its transfer paths were different depending on the excitation floor locations due to differences in the structural characteristics. From the measurement result, transfer characteristics were quantified by statistical energy analysis. It was confirmed that the heavy-weight floor impact noise influence not only adjacent floor. The impact noise transferred and affected multiple layers.

  • PDF

공유형 동조질량감쇠기를 이용한 인접건물의 지진응답제어 (Seismic Response Control of Adjacent Buildings Using Shared Tuned Mass Damper)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제14권3호
    • /
    • pp.75-84
    • /
    • 2014
  • When adjacent tall buildings experience earthquake excitation, structural pounding may happen. In order to mitigate seismic pounding damage to adjacent structures, many studies have been done to date. Tuned mass dampers (TMD) are widely used for reduction of dynamic responses of building structures subjected to earthquake excitations. If a TMD is shared between adjacent buildings and it shows good control performance, it will be effective and economic means to reduce seismic responses of adjacent structures. In this study, control performance of a shared tuned mass damper (STMD) for seismic response reduction of adjacent buildings has been evaluated. For this purpose, two 8-story example buildings were used and multi-objective genetic algorithms has been employed for optimal design of the stiffness and damping parameters of the STMD. Based on numerical analyses, it has been shown that a STMD can effectively control dynamic responses and reduce the effect of pounding between adjacent buildings subjected to earthquake excitations in comparison with a traditional TMD.

Stability of multi-step flexural-shear plates with varying cross-section

  • Xu, J.Y.;Li, Q.S.
    • Structural Engineering and Mechanics
    • /
    • 제16권5호
    • /
    • pp.597-612
    • /
    • 2003
  • In this paper, multi-story buildings with shear-wall structures and with narrow rectangular plane configuration are modeled as a multi-step flexural-shear plate with varying cross-section for buckling analysis. The governing differential equation of such a plate is established. Using appropriate transformations, the equation is reduced to analytically solvable equations by selecting suitable expressions of the distribution of stiffness. The exact solutions for buckling of such a one-step flexural-shear plate with variable stiffness are derived for several cases. A new exact approach that combines the transfer matrix method and closed from solution of one-step flexural-shear plate with continuously varying stiffness is presented for stability analysis of multi-step non-uniform flexural-shear plate. A numerical example shows that the present methods are easy to implement and efficient.

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

Mushroom skeleton to create rocking motion in low-rise steel buildings to improve their seismic performance

  • Mahdavi, Vahid;Hosseini, Mahmood;Gharighoran, Alireza
    • Earthquakes and Structures
    • /
    • 제15권6호
    • /
    • pp.639-654
    • /
    • 2018
  • Rocking motion have been used for achieving the 'resilient buildings' against earthquakes in recent studies. Low-rise buildings, unlike the tall ones, because of their small aspect ratio tend to slide rather than move in rocking mode. However, since rocking is more effective in seismic response reduction than sliding, it is desired to create rocking motion in low-rise buildings too. One way for this purpose is making the building's structure rock on its internal bay(s) by reducing the number of bays at the lower part of the building's skeleton, giving it a mushroom form. In this study 'mushroom skeleton' has been used for creating multi-story rocking regular steel buildings with square plan to rock on its one-by-one bay central lowest story. To show if this idea is effective, a set of mushroom buildings have been considered, and their seismic responses have been compared with those of their conventional counterparts, designed based on a conventional code. Also, a set of similar buildings with skeleton stronger than code requirement, to have immediate occupancy (IO) performance level, have been considered for comparison. Seismic responses, obtained by nonlinear time history analyses, using scaled three-dimensional accelerograms of selected earthquakes, show that by using appropriate 'mushroom skeleton' the seismic performance of buildings is upgraded to mostly IO level, while all of the conventional buildings experience collapse prevention (CP) level or beyond. The strong-skeleton buildings mostly present IO performance level as well, however, their base shear and absolute acceleration responses are much higher than the mushroom buildings.

바닥충격음 평가를 위한 고무공 충격원의 타당성 검토 (Investigating the adequacy of Rubber Ball Impactor for Floor Impact Noise Evaluation)

  • Hyung Joon, Moon;Jeong Ho, Jeong;Sung Chan, Lee;Jin Yong, Jeon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.350.2-350
    • /
    • 2002
  • The purpose of this study was to present the possible use of a new standard impactor, the rubber ball (so-called, impact ball), and to assess its evaluation method as fur heavy-weight impact in multi-story residential buildings. Several experiments were carried out to investigate the effect of the impactor on noise propagation in reinforced concrete buildings. Then, the noise from the impact ball was psychoacoustically evaluated. (omitted)

  • PDF

Vulnerability curves of masonry constructions Algiers case study

  • Djaalali, F.;Bensaibi, M.;Bourahla, N.;Davenne, L.
    • Structural Engineering and Mechanics
    • /
    • 제42권5호
    • /
    • pp.609-629
    • /
    • 2012
  • This study deals with the assessment of low and mid rise multi-story buildings made of stone and /or brick, composite steel and masonry slabs from the sixties, known to be vulnerable to seismic hazard using the "vulnerability index" method based on buildings survey following Ain Temouchent (1999) and Boumerdes (2003) earthquakes, from where vulnerability curves are constructed using the translation method. The results obtained for the case study confirm what has been observed in situ.