• Title/Summary/Keyword: multi-pulse

Search Result 478, Processing Time 0.03 seconds

Discrimination of Multi-PD sources using wavelet 2D compression for T-F distribution of PD pulse waveform (부분방전 펄스파형의 시간-주파수분포의 웨이블렛 2D 압축기술을 이용한 복합부분방전원의 식별)

  • Lee, K.W.;Kim, M.Y.;Baik, K.S.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1784-1786
    • /
    • 2004
  • PD(Partial Discharge) signal emitted from PD sources has their intrinsic features in the region of time and frequency. STFT(Short Time Fourier Transform) shows time-frequency distribution at the same time. 2-Dimensional matrices(33${\times}$77) from STFT for PD pulse signals are a good feature vectors and can be decreased in dimension by wavelet 2D data compression technique. Decreased feature vectors(13${\times}$24) were used as inputs of Back-propagation ANN(Artificial Neural Network) for discrimination of Multi-PD sources(air discharge sources(3), surface discharge(1)). They are a good feature vectors for discriminating Multi-PD sources.

  • PDF

On the Performance of Multi-User 2PPM-TH-UWB SIMO Systems in Multipath Channels

  • Baek, Sun-Young;Kang, Yun-Jeong;Kim, Sang-Choon
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.286-291
    • /
    • 2009
  • In this paper, the performance of ultra-wideband (UWB) single input multiple output (SIMO) systems to achieve high data rate communications is studied in dense multipath environments. The effects of spatial and temporal diversities on the performance of multi-user time-hopping UWB systems using binary pulse position modulation (2PPM) are analyzed. The reduced-complexity Rake receivers based on the selective combining (called SRake) and partial combining (called PRake) are considered. The theoretical and simulation results show that the BER performance of the UWB system can be enhanced as the number of array elements and/or Rake fingers increases. Moreover, we observe that SRake is more effective for the IR-UWB systems to achieve a good BER performance, as compared with PRake.

Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor (어레이 압저항 센서를 활용한 체질맥 임상연구)

  • Lee, Si-Woo;Joo, Jong-Cheon;Kim, Kyung-Yo;Kim, Jong-Yeol
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.1
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

3-D High Resolution Ultrasonic Transmission Tomography and Soft Tissue Differentiation

  • Kim Tae-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.55-63
    • /
    • 2005
  • A novel imaging system for High-resolution Ultrasonic Transmission Tomography (HUTT) and soft tissue differentiation methodology for the HUTT system are presented. The critical innovation of the HUTT system includes the use of sub-millimeter transducer elements for both transmitter and receiver arrays and multi-band analysis of the first-arrival pulse. The first-arrival pulse is detected and extracted from the received signal (i.e., snippet) at each azimuthal and angular location of a mechanical tomographic scanner in transmission mode. Each extracted snippet is processed to yield a multi-spectral vector of attenuation values at multiple frequency bands. These vectors form a 3-D sinogram representing a multi-spectral augmentation of the conventional 2-D sinogram. A filtered backprojection algorithm is used to reconstruct a stack of multi-spectral images for each 2-D tomographic slice that allow tissue characterization. A novel methodology for soft tissue differentiation using spectral target detection is presented. The representative 2-D and 3-D HUTT images formed at various frequency bands demonstrate the high-resolution capability of the system. It is shown that spherical objects with diameter down to 0.3㎜ can be detected. In addition, the results of soft tissue differentiation and characterization demonstrate the feasibility of quantitative soft tissue analysis for possible detection of lesions or cancerous tissue.

A study on Intention Pulse Forming Network Generation of Pulse Nd:YAG Laser adopting Multi -Alienation Discharge (다중분할 방전방식을 적용한 펄스형 Nd:YAG 레이저의 임의 펄스성형 연구)

  • Whi-Young Kim
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.7
    • /
    • pp.975-982
    • /
    • 2001
  • In this study, a solid-state laser system adopting a new real time multi-discharge (RTMD) method in which three flashlamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp rum-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC one-chip microprocessor. With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and the real-time control is possible with an external keyboard, enabling various pulse shapes. In addition, longer pulses can be more widely used for industrial processing and lots of medical purposes

  • PDF

An Analysis of the Distortions of High Speed Pulse Signal on the Microstrip Lines of the Single and Coupled Structures (단일 및 결합형 구조의 마이크로 스트립 전송선로에서 고속 펄스 신호의 왜곡 특성 분석)

  • 김기래
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.529-534
    • /
    • 2002
  • Recently, As the higher frequency in clock of digital system being demanded and the density of circuits gets high for purpose of making light and minimizing system, the study for solution of digital signal distortion being interested. In this paper, the distortion of square pulse caused by dispersion as it propagates along a single microstrip line and crosstalk between lines on the Multi-Transmission Lines (MTL) is investigated. The dispersion and crosstalk of pulse signals is analyzed regarding to the structure of transmission line such as relative permittivity, substrate height, strip width of the microstrip line and pulse width of signal pulse.

Maximum Likelihood Based Doppler Estimation and Target Detection with Pulse Code Modulated Waveform (ML 기법을 이용한 PCM 파형에서의 표적 탐지 및 도플러 추정)

  • Yang, Eunjung;Lee, Heeyoung;Song, Junho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1275-1283
    • /
    • 2014
  • Characteristics of PCM(Pulse Code Modulation) waveform are suitable for target tracking. Especially in terms of dwell time, it is desirable to detect and track a moving target with the single PCM waveform for a MFR(Multi-Function Radar) which carries out multiple tasks. General PCM waveform processing includes Doppler filter bank caused by the characteristics of ambiguity function, to detect target and estimate Doppler frequency, which induces hardware burden and computational complexity. We propose a ML(Maximum Likelihood) based Doppler estimator for a PCM waveform, which is the closed form suboptimal solution and computationally efficient to estimate Doppler frequency and detect a moving target.

A Study on Multi-Pulse Speech Coding Method by Using V/S/TSIUVC (V/S/TSIUVC를 이용한 멀티펄스 음성부호화 방식에 관한 연구)

  • Lee See-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.9
    • /
    • pp.1233-1239
    • /
    • 2004
  • In a speech coding system using excitation source of voiced and unvoiced, it would be involved a distortion of speech qualify in case coexist with a voiced and an unvoiced consonants in a frame. This paper present a new multi-pulse coding method by using V/S/TSIUVC switching, individual pitch pulses and TSIUVC approximation-synthesis method in order to restrict a distortion of speech quality. The TSIUVC is extracted by using the zero crossing rate and individual pitch pulse. And the TSIUVC extraction rate was 91% for female voice and 96.2% for male voice respectively. The important thing is that the frequency information of 0.347kHz below and 2.813kHz above can be made with high quality synthesis waveform within TSIUVC. I evaluate the MPC use V/UV and the FBD-MPC use V/S/TSIUVC. As a result, I knew that synthesis speech of the FBD-MPC was better in speech quality than synthesis speech of the MPC.

  • PDF

Multiple Access Scheme Using Modified Hermite Polynomial Pulse and Ternary code for Out-Body WBAN (신체 외부 통신에서 MHP 펄스와 터너리 코드를 이용한 다중접속 기법)

  • Shim, Jae-Joon;Hwang, Jae-Ho;Kim, Jae-Moung
    • Journal of Internet Computing and Services
    • /
    • v.12 no.1
    • /
    • pp.27-38
    • /
    • 2011
  • In this paper, we propose a multiple access scheme using MHP(Modified Hermite Polynomial) pulse and ternary code for high-data and low-data rate for Out-body WBAN(Wireless Body Area Network). To satisfy the requirement of WBAN system, UWB-IR has been considered as a promising candidate for Out-body WBAN. The proposed multiple access scheme, using orthogonal MHP pulse and ternary code sets, reduces multi-user interference and distinguishes user signal from multi-user signals. We propose two algorithms for synchronous and asynchronous WBAN system. The symbol is constructed by MHP pulses and time hopping duration to reduce multi-user interference in the synchronous WBAN system. The symbol also is constructed by ternary code to avoid collision between pulse trains in the asynchronous WBAN system. The results of the proposed multiple access scheme show a clear improvement of BER.

A Study on the RF performance analysis for Multi-band Ultra Wide Band Systems (멀티밴드 UWB 시스템의 무선성능 분석에 관한 연구)

  • Choi, Seok;Kim, Gil-Gyeom;Kwack, Jun-Ho;Kim, Hak-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12A
    • /
    • pp.951-957
    • /
    • 2003
  • The analysis of RF performance requirement conditions on communication system is critical indicator to predict the performance of system. UWB(Ultra Wide Band) system which the standard is not established yet is difficult to derive the precise system performance requirement condition. Also, there are differences between conventional UWB system and multi-band system about RF performance requirement condition. In this thesis, the differences are analyzed and performance requirement conditions of multi-band UWB system are described on the basis of the differences. Throughput, maximum transmit power, and sensitivity of multi-band UWB system is varied with respect to the number of Sub-Bands. In addition, because of Multi-path effect, if PRF(Pulse Repetition Frequency) is changed, the Multi-path link margin is happened to compensate for Multi-path Energy Loss which is contributed by increasing of the Link Margin. According to Multi-path Margin, the variation of the resistance with respect to sensitivity and interference signal is observed and analyzed through the simulation.