• 제목/요약/키워드: multi-pole algorithm

검색결과 24건 처리시간 0.021초

Optimal Rotor Shape Design of Asymmetrical Multi-Layer IPM Motors to Improve Torque Performance Considering Irreversible Demagnetization

  • Mirazimi, M.S.;Kiyoumarsi, A.;Madani, Sayed M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1980-1990
    • /
    • 2017
  • A study on the multi-objective optimization of Interior Permanent-Magnet Synchronous Motors (IPMSMs) with 2, 3, 4 and 5 flux barriers per magnetic pole, based on Genetic Algorithm (GA) is presented by considering the aspect of irreversible demagnetization. Applying the 2004 Toyota Prius single-layer IPMSM as the reference machine, the asymmetrical two-, three-, four- and five-layer rotor models with the same amount of Permanent-Magnets (PMs) is presented to improve the torque characteristics, i.e., reducing the torque pulsation and increasing the average torque. A reduction of the torque pulsations is achieved by adopting different and asymmetrical flux barrier geometries in each magnetic pole of the rotor topology. The demagnetization performance in the PMs is considered as well as the motor performance; and analyzed by using finite element method (FEM) for verification of the optimal solutions.

대용량 BLDC 전동기의 영구자석 형상 최적화를 통한 최적화 기법 연구 (A Study on the Optimization Strategy using Permanent Magnet Pole Shape Optimization of a Large Scale BLDC Motor)

  • 우성현;신판석;오진석;공영경;빈재구
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.897-903
    • /
    • 2010
  • This paper presents a response surface method(RSM) with Latin Hypercube Sampling strategy, which is employed to optimize a magnet pole shape of large scale BLDC motor to minimize the cogging torque. The proposed LHS algorithm consists of the multi-objective Pareto optimization and (1+1) evolution strategy. The algorithm is compared with the uniform sampling point method in view points of computing time and convergence. In order to verify the developed algorithm, a 6 MW BLDC motor is simulated with 4 design parameters (arc length and 3 variables for magnet) and 4 constraints for minimizing of the cogging torque. The optimization procedure has two stages; the fist is to optimize the arc length of the PM and the second is to optimize the magnet pole shape by using the proposed hybrid algorithm. At the 3rd iteration, an optimal point is obtained, and the cogging torque of the optimized shape is converged to about 14% of the initial one. It means that 3 iterations aregood enough to obtain the optimal design parameters in the program.

다입력-다출력 시스템의 가제어성 정준형에 관한 연구 (A Study on controllable canonical forms for multi-input multi-output systems)

  • 오세호;변증남
    • 대한전자공학회논문지
    • /
    • 제17권6호
    • /
    • pp.9-16
    • /
    • 1980
  • 상태 방정식으로 기술되는 다입력-다출fur 시스템에 대해 상태 궤환을 이용하여 전 시스템의 극(pole)을 S- 평면의 지정하는 곳으로 이동시킬 수 있다. 본 논문에서는 극배정 (pole assingnment)을 위한 상태 궤환이득 행열을 효과적으로 구할 수 있는 정준형(canonical form)에 대하여 논의하였으며 이러한 정준형이 주어진 경우 극을 원하는 곳에 배정하는 상태 궤환 이득 행열의 계산 방법에 대하여 논의하였다.

  • PDF

MLFMA for Capacitance Extraction using Adaptive Triangular Mesh

  • Kim, Han;Ahn, Chang-Hoi
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.78-82
    • /
    • 2001
  • For fast capacitance computation, a simple mesh refinement technique on MLFMA(Multi-Level Fast Multipole Algorithm) is proposed The triangular meshes are refined mainly in the area which has heavy charge density. The technique is applied to the capacitance extraction of three dimensional conductors. The results show good convergence with comparable accuracy. An adaptive technique concerned with MLFMA is useful to reduce computation time and the number of elements without additional computational efforts in large three dimensional problems.

  • PDF

극배치 제어기법을 이용한 자기부상열차용 전원장치에 관한 연구 (A Study on the Power Supply of a magnetic levitation system(MAGLEV) using pole placement technique)

  • 정춘병;이상현;김은기;조정민;전기영;강승욱;김용주;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.418-420
    • /
    • 2007
  • When the magnetic levitation system(MAGLEV) initially rise, The MAGLEV has a weak point that is very large variation of the electric current. In this paper, The author applied the multi-loop-control to stably control the magnetic levitation system(MAGLEV). The gains of the control algorithm were selected based on pole locations formulated from a prototype Bessel transfer function model. The design incorporate tradeoffs in DC-to-DC converter hard-ware para-meters and pole locations. In order to confirm the superiority of the proposed pole selection and controller, MATLAB simulation and experiment results are presented.

  • PDF

Seismic response of active or semi active control for irregular buildings based on eigenvalues modification

  • Pnevmatikos, Nikos G.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • 제6권6호
    • /
    • pp.647-664
    • /
    • 2014
  • A reduction of the response of irregular structures subjected to earthquake excitation by control devices equipped by suitable control algorithm is proposed in this paper. The control algorithm, which is used, is the pole placement one. A requirement of successful application of pole placement algorithm is a definition-selection of suitable poles (eigen-values) of controlled irregular structures. Based on these poles, the required action is calculated and applied to the irregular structure by means of control devices. The selection of poles of controlled irregular structure, is a critical issue for the success of the algorithm. The calculation of suitable poles of controlled irregular structure is proposed herein by the following procedure: a fictitious symmetrical structure is considered from the irregular structure, adding vertical elements, such as columns or shear walls, at any location where is necessary. Then, the eigen-values of symmetrical structure are calculated, and are forced to be the poles of irregular controlled structure. Based on these poles and additional damping, the new poles of the controlled irregular structure are calculated. By pole placement algorithm, the feedback matrix is obtained. Using this feedback matrix, control forces are calculated at any time during the earthquake, and are applied to the irregular structure by the control devices. This procedure results in making the controlled irregular structure to behave like a symmetrical one. This control strategy can be applied to one storey or to multi-storey irregular buildings. Furthermore, the numerical results were shown that with small amount of control force, a sufficient reduction of the response of irregular buildings is achieved.

자기회로 이론을 이용한 링형 다극 유도형 변위센서의 모델링 (Modelling of a Ring-type Multi-pole Inductive Position Sensor Using Magnetic Circuit Theory)

  • 김지미;노명규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.207-211
    • /
    • 2004
  • The performance of an inductive position sensor has approved by previous research papers. In this paper, magnetic circuit model of a ring-type multi-pole insuctive position sensor is described. The magnetic circuit model is required to design in ductive position sensor as well as draw a fault tolerance algorithm. Using the magnetic circuit theory, we derived the relationship between voltage applied and flux density in the normal air-gap. By idealizing the modulation/demodulation processes of signal processing circuit, sensor gain with respect to change of displacement is theoretically calculation using the magnetic circuit model, which validate the theoretical derivation.

  • PDF

손실을 고려한 영구자석형 다극 기기의 발전특성해석 (The Generating Characteristic Analysis of Permanent Magnet Machines with Multi-Pole Rotor Considering Losses)

  • 장석명;최장영;고경진;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.47-49
    • /
    • 2007
  • This paper deals with the generating characteristic analysis of permanent magnet (PM) machines with multi-pole rotor and 3-phase stator windings considering losses such as copper loss, iron loss and mechanical loss. First, using d-q transformation, dynamic equations of PM machines are established. And then, characteristic equations for losses, power and efficiency are also derived. On the basis of d-q dynamic equations and characteristic equations, dynamic simulation algorithm is achieved by the MATLAB/SIMULINK. The simulation results are validated extensively by finite element (FE) analyses.

  • PDF

극배치 자기-동조 안정기에 의한 다변수 제어계의 설계 (Computer Aided Design of Multivariable Control Systems by Pole-Assignment Self-Tuning Regulators)

  • 심재철;전상영;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.76-78
    • /
    • 1987
  • This paper describes the theory and application of a multi-input/multi-output self-tuning regulator where the control objective is the assignment of the closed-loop pole set to prespecified locations. The algorithm described In this paper has a 'self-tuning' property. This self-tuners are more robust than the tuners that are based on optimal control synthesis method. This paper demonstrate usefulness of the algorithms by means of some simulation studies.

  • PDF

부분 음영에서의 태양광 발전 효율을 높이기 위한 MPPT 전략 (MPPT Strategy to Improve Photovoltaic Power Generation Efficiency in Partial Shadows)

  • 허철영;김용래;이영권;이동윤;최익;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제39권2호
    • /
    • pp.1-9
    • /
    • 2019
  • In order to increase the power generation efficiency of the photovoltaic system, a new algorithm that can follow the maximum power point of the photovoltaic power generation system having nonlinear output characteristics is proposed. Conventional maximum power point tracking (MPPT) algorithms such as Perturbation and Observation (P&O) and InCond (Increment and Conductance) schemes can not find the global maximum power point at a plurality of pole points in the unmatched state of unbalanced PV modules. However, even if the global maximum power point is found at a plurality of pole points, the global maximum power that can not be the real maximum power by the photovoltaic generation system. In order to solve this problem, a few PV companies propose installing several small PV inverters instead of if big one. However, since this will require additional costs, we herein propose a Multi-MPPT system using individual 3-point MPPT to track true MPPT at a plurality of pole points in the unmatched state of unbalanced PV modules.