• Title/Summary/Keyword: multi-physics

Search Result 671, Processing Time 0.025 seconds

Evaluation of neutronics parameters during RSG-GAS commissioning by using Monte Carlo code

  • Surian Pinem;Wahid Luthfi;Peng Hong Liem;Donny Hartanto
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1775-1782
    • /
    • 2023
  • Several reactor physics commissioning experiments were conducted to obtain the neutronic parameters at the beginning of the G.A. Siwabessy Multi-purpose Reactor (RSG-GAS) operation. These parameters are essential for the reactor to safety operate. Leveraging the experimental data, this study evaluated the calculated core reactivity, control rod reactivity worth, integral control rod reactivity curve, and fuel reactivity. Calculations were carried out with Serpent 2 code using the latest neutron cross-section data ENDF/B-VIII.0. The criticality calculations were carried out for the RSG-GAS first core up to the third core configuration, which has been done experimentally during these commissioning periods. The excess reactivity for the second and third cores showed a difference of 510.97 pcm and 253.23 pcm to the experiment data. The calculated integral reactivity of the control rod has an error of less than 1.0% compared to the experimental data. The calculated fuel reactivity value is consistent with the measured data, with a maximum error of 2.12%. Therefore, it can be concluded that the RSG-GAS reactor core model is in good agreement to reproduce excess reactivity, control rod worth, and fuel element reactivity.

A Variable Protostar, EC 53

  • Lee, Yong-Hee;Lee, Jeong-Eun;Johnstone, Doug;Herczeg, Gregory J.;Mairs, Steve;Varricatt, Watson;Contreras, Carlos
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.68.2-68.2
    • /
    • 2019
  • Most of the stellar mass accretes during the early evolutionary stage of protostars. However, the accretion process in protostars is in a veil of the thick envelope. Monitoring the submillimeter emission from the envelope is a way to trace the accretion process in protostars since the submillimeter emission linearly responses to the temperature of the envelope, which is heated by the accretion process at the center. In the JCMT transient Survey, we detected a submillimeter variable, EC 53. EC 53 is a Class 1 protostar that was known to have a periodic variation at NIR. EC 53 has been monitored with United Kingdom InfraRed Telescope (UKIRT), Liverpool telescope, and JCMT/SCUBA-2 since we detected the 850 ㎛ flux enhancement in the JCMT transient survey. We also adopt the photometric data sets of Wide-field Infrared Survey Explorer (WISE). Over all wavelengths from NIR to submillimeter, we see two modes of variation, a 1.5-years periodic variation and a long-term increase. We present the light curves of EC 53 at multi-wavelengths and discuss the cause of variability in EC 53.

  • PDF

Study on improving passive sonar detection using acoustic vibration matching method for front and rear signal of complex sensor (복합센서의 전후방 신호에 대한 음향진동 정합기법을 이용한 수동소나 탐지성능 향상에 대한 연구)

  • Dongwan Seo;Woosuk Chang;Donghyeon Kim;Eunghwy Noh;Jeongeun Yang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.145-151
    • /
    • 2024
  • Recently, ship hull-mounted passive sonar system solution is needed in the perspective of improving target detection and elimination of vibration-induced noise. Our research team suggests acousticvibration matching method using front and rear signal of a sensor as the improvement of the problem above. Thus in this paper, theoretical background about matching method and its application on finite element method based multi-physics simulation are described. Furthermore, it is shown that target detection and hull vibration performance are improved by using matching method under the condition of our sensor system. Finally, practicality and future research are discussed.

Implementation of Saemangeum Coastal Environmental Information System Using GIS (지리정보시스템을 이용한 새만금 해양환경정보시스템 구축)

  • Kim, Jin-Ah;Kim, Chang-Sik;Park, Jin-Ah
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.128-136
    • /
    • 2011
  • To monitor and predict the change of coastal environment according to the construction of Saemangeum sea dyke and the development of land reclamation, we have done real-time and periodic ocean observation and numerical simulation since 2002. Saemangeum coastal environmental data can be largely classified to marine meteorology, ocean physics and circulation, water quality, marine geology and marine ecosystem and each part of data has been generated continuously and accumulated over about 10 years. The collected coastal environmental data are huge amounts of heterogeneous dataset and have some characteristics of multi-dimension, multivariate and spatio-temporal distribution. Thus the implementation of information system possible to data collection, processing, management and service is necessary. In this study, through the implementation of Saemangeum coastal environmental information system using geographic information system, it enables the integral data collection and management and the data querying and analysis of enormous and high-complexity data through the design of intuitive and effective web user interface and scientific data visualization using statistical graphs and thematic cartography. Furthermore, through the quantitative analysis of trend changed over long-term by the geo-spatial analysis with geo- processing, it's being used as a tool for provide a scientific basis for sustainable development and decision support in Saemangeum coast. Moreover, for the effective web-based information service, multi-level map cache, multi-layer architecture and geospatial database were implemented together.

HVPE growth of GaN/InGaN heterostructure on r-plane sapphire substrate (R-plane 사파이어 기판위의 GaN/InGaN 이종접합구조의 HVPE 성장)

  • Jeon, H.S.;Hwang, S.L.;Kim, K.H.;Jang, K.S.;Lee, C.H.;Yang, M.;Ahn, H.S.;Kim, S.W.;Jang, S.H.;Lee, S.M.;Park, G.H.;Koike, M.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.1
    • /
    • pp.6-10
    • /
    • 2007
  • The a-plane GaN layer on r-plane $Al_2O_3$ substrate is grown by mixed-source hydride vapor phase epitaxy (HVPE). The GaN/InGaN heterostructure is performed by selective area growth (SAG) method. The heterostructure consists of a flown over mixed-sourec are used as gallium (or indium) and nitrogen sources. The gas flow rates of HCl and $NH_3$ are maintained at 10 sccm and 500 sccm, respectively. The temperatures of GaN source zone is $650^{\circ}C$. In case of InGaN, the temperature of source zone is $900^{\circ}C$. The grown temperatures of GaN and InGaN layer are $820^{\circ}C\;and\;850^{\circ}C$, respectively. The EL (electroluminescence) peak of GaN/InGaN heterostructure is at nearly 460 nm and the FWHM (full width at half maximum) is 0.67 eV. These results are demonstrated that the heterostructure of III-nitrides on r-plane sapphire can be successfully grown by mixed-source HVPE with multi-sliding boat system.

Exploration of Optimal Multi-Core Processor Architecture for Physical Modeling of Plucked-String Instruments (현악기의 물리적 모델링을 위한 최적의 멀티코어 프로세서 아키텍처 탐색)

  • Kang, Myeong-Su;Choi, Ji-Won;Kim, Yong-Min;Kim, Jong-Myon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.281-294
    • /
    • 2011
  • Physics-based sound synthesis usually requires high computational costs and this results in a restriction of its use in real-time applications. This motivates us to implement the sound synthesis algorithm of plucked-string instruments using multi-core processor architectures and determine the optimal processing element (PE) configuration for the target instruments. To determine the optimal PE configuration, we evaluate the impacts of a sample-per-processing element (SPE) ratio that is defined as the amount of sample data directly mapped to each PE on system performance and both area and energy efficiencies using architectural and workload simulations. For the acoustic guitar, the highest area and energy efficiencies are achieved at a SPE ratio of 5,513 and 2,756, respectively, for the synthesis of musical sounds sampled at 44.1 kHz. In the case of the classical guitar, the maximum area and energy efficiencies are achieved at a SPE ratio of 22,050 and 5,513, respectively. In addition, the synthetic sounds were very similar to original sounds in their spectra. Furthermore, we conducted MUSHRA subjective listening test with ten subjects including nine graduate students and one professor from the University of Ulsan, and the evaluation of the synthetic sounds was excellent.

TRIO (Triplet Ionospheric Observatory) CINEMA

  • Lee, Dong-Hun;Seon, Jong-Ho;Jin, Ho;Kim, Khan-Hyuk;Lee, Jae-Jin;Jeon, Sang-Min;Pak, Soo-Jong;Jang, Min-Hwan;Kim, Kap-Sung;Lin, R.P.;Parks, G.K.;Halekas, J.S.;Larson, D.E.;Eastwood, J.P.;Roelof, E.C.;Horbury, T.S.
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.42.3-43
    • /
    • 2009
  • Triplets of identical cubesats will be built to carry out the following scientific objectives: i) multi-observations of ionospheric ENA (Energetic Neutral Atom) imaging, ii) ionospheric signature of suprathermal electrons and ions associated with auroral acceleration as well as electron microbursts, and iii) complementary measurements of magnetic fields for particle data. Each satellite, a cubesat for ion, neutral, electron, and magnetic fields (CINEMA), is equipped with a suprathermal electron, ion, neutral (STEIN) instrument and a 3-axis magnetometer of magnetoresistive sensors. TRIO is developed by three institutes: i) two CINEMA by Kyung Hee University (KHU) under the WCU program, ii) one CINEMA by UC Berkeley under the NSF support, and iii) three magnetometers by Imperial College, respectively. Multi-spacecraft observations in the STEIN instruments will provide i) stereo ENA imaging with a wide angle in local times, which are sensitive to the evolution of ring current phase space distributions, ii) suprathermal electron measurements with narrow spacings, which reveal the differential signature of accelerated electrons driven by Alfven waves and/or double layer formation in the ionosphere between the acceleration region and the aurora, and iii) suprathermal ion precipitation when the storm-time ring current appears. In addition, multi-spacecraft magnetic field measurements in low earth orbits will allow the tracking of the phase fronts of ULF waves, FTEs, and quasi-periodic reconnection events between ground-based magnetometer data and upstream satellite data.

  • PDF

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.