• 제목/요약/키워드: multi-mode design

검색결과 461건 처리시간 0.026초

Optimal Trajectory Generation for Biped Robots Walking Up-and-Down Stairs

  • Kwon O-Hung;Jeon Kweon-Soo;Park Jong-Hyeon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.612-620
    • /
    • 2006
  • This paper proposes an optimal trajectory generation method for biped robots for walking up-and-down stairs using a Real-Coded Genetic Algorithm (RCGA). The RCGA is most effective in minimizing the total consumption energy of a multi-dof biped robot. Each joint angle trajectory is defined as a 4-th order polynomial of which the coefficients are chromosomes or design variables to approximate the walking gait. Constraints are divided into equalities and inequalities. First, equality constraints consist of initial conditions and repeatability conditions with respect to each joint angle and angular velocity at the start and end of a stride period. Next, inequality constraints include collision prevention conditions of a swing leg, singular prevention conditions, and stability conditions. The effectiveness of the proposed optimal trajectory is shown in computer simulations with a 6-dof biped robot model that consists of seven links in the sagittal plane. The optimal trajectory is more efficient than that generated by the Modified Gravity-Compensated Inverted Pendulum Mode (MGCIPM). And various trajectories generated by the proposed GA method are analyzed from the viewpoint of the consumption energy: walking on even ground, ascending stairs, and descending stairs.

최적전류를 이용한 IPMSM 드라이브의 최대토크 제 (Maximum Torque Control of IPMSM Drive using Optimal Current)

  • 백정우;고재섭;최정식;강성준;장미금;문주희;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.57-58
    • /
    • 2010
  • This paper proposes maximum torque control of IPMSM drive using optimal current. This control method is applicable over the entire speed range which considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal d-axis current $i_d$ for maximum torque operation is derived. This paper considers the design and implementation of novel technique of high performance speed control for IPMSM using multi-MFC and ANN controller. Also, this paper proposes maximum control of IPMSM drive using approximation method. This method is decreased the burden of digital signal process(DSP) in calculation of optimal current. This paper proposes the analysis results to verify the effectiveness of the MFC and ANN controller. Also it verifies the validity of maximum torque control of IPMSM drive with optimal current.

  • PDF

8단자 가변 임피던스 전자파 발생 장치를 이용한 표준 복사 전자기장 조성 연구 (Study for generation of standard EM field using 8 ports-variable wave impedance generator)

  • 윤재훈
    • 한국통신학회논문지
    • /
    • 제21권3호
    • /
    • pp.771-783
    • /
    • 1996
  • 8단자 가변임피던스 전자파 발생장치(8P-VWIG:8Ports-Variable Wave Impedance Generator)에 대한 설계 기술에 대해 나타내고, 내부에서 유기뇌는 전자기장 및 특성임피던스에 대한 수치해석, 일정한 특성임피던스를 갖는 구조에 대해 간단하게 추적할 수 있는 수치알고리즘에 대해 나타내었다. 또한 특정 구조에 대한 균일도 평가결과와 내부 전자계 분포, 그리고 그 응용으로서 EMS 측정시스템에 대한 간단한 소개를 나타내었다. 8P-VWIG는 기존 간이 EMI/EMS 시설들에 비해 시험공간의 활용도가 좋고, 수직 수평 분극 조성이 자유로운 장점을 가지고 있다. 제작된 8P-VWIG는 정재파비로 측정된 제 1공진이 152.1MHz에서 발생하고, $50{\Omega}$ 임피던스 정합 시스템으로 동작하도록 한 8채널의 다중전송선로 구조를 갖는다.

  • PDF

CORDIC을 이용한 디지탈 Quadrature 복조기의 VLSI 구현 (VLSI Implementation of CORDIC-Based Digital Quadrature Demodulator)

  • 남승현;성원용
    • 한국통신학회논문지
    • /
    • 제23권7호
    • /
    • pp.1718-1731
    • /
    • 1998
  • 디지탈 quadrature 복조기는 디지탈 통신 시스템에서 변조된 신호의 정확한 위상 복조를 위해 꼭 필요하다. 기존의 방법들은 주로 DDFS(Direct Digital Frequency Synthsizer)를 이용하여 캐리어를 발생시킨 후에 승산기를 이용하여 복조를 수행하였다. 그리고, DDFS에는 주로 ROM(Read Only Memory)을 사용하였는데, 높은 속도와 정확도를 요구하는 경우 ROM의 속도와 크기가 제한이 될 수있다. 이러한 점을 극복하기 위하여 CORDIC(COordinate Rotation Digital Computer) 알고리듬을 사용하여 주파수 합성은 물론 캐리어 복조까지 수행하는 방식을 제안하였다. 최적의 하드웨어 구현을 위해 제한된 단어길이에 의한 영향을 분석하였으며, 하드웨어 비용면에서 ROM을 사용하는 방법과 비교한 결과 약 1/3 정도로 면적이 줄었다. 제안된 구조를 이요한 전주문형 VLSI 구현 결과를 보인다.

  • PDF

태양열 냉난방 부하산정을 위한 TRNSYS 동적 시뮬레이션 (TRNSYS Dynamic Simulation for Solar Heating and Cooling Load Estimations)

  • 최창용;고상철;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.1-6
    • /
    • 2006
  • This paper presents the heating and cooling load estimations for the library of a cultural center building located in Gwangju Korea by TRNSYS with Type 56 of multi-zone building components. In this study, energy rate control mode is selected and the design temperatures for heating and cooling are specified respectively as 20oC and 26oC. Reading rooms of the library are located on the third floor of the cultural center building, and this third floor space is modeled as the five thermal zones for the TRNSYS simulation. Among the five zones, attention is given to the two zones which are the reading rooms 1 and 2. Since these two zones are to be heated and cooled by the solar thermal system which is planned to be installed in the building, dynamic thermal behaviors of the two zones are analyzed by the heating and cooling load estimations.

MB-OFDM UWB System용 Fast Setting PLL 개발 (Development of the fast setting PLL for MB-OFDM UWB system)

  • 이영재;현석봉;탁금영;김천수;유현규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.607-608
    • /
    • 2006
  • A CMOS phase-locked loop (PLL) which synthesizes frequencies between $6.336{\sim}8.976GHz$ in steps of 528MHz and settles in approximately 150ns using the 528MHz reference clock is presented. Frequency hopping between the bands in the each mode is critical point to design the PLL in multi-band orthogonal frequency division multiplexing (OFDM) because frequency switching between each band is less than 9.5ns. To achieve the fast loop settling, integer-N PLL that operates with the high reference frequency to meet the settling requirement is implemented. Two PLLs that operate at 9GHz and 528MHz is integrated and shows the band hopping lower than 1ns.

  • PDF

Effect of higher modes and multi-directional seismic excitations on power plant liquid storage pools

  • Eswaran, M.;Reddy, G.R.;Singh, R.K.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.779-799
    • /
    • 2015
  • The slosh height and the possibility of water spill from rectangular Spent Fuel Storage Bays (SFSB) and Tray Loading Bays (TLB) of Nuclear power plant (NPP) are studied during 0.2 g, Safe Shutdown Earthquake (SSE) level of earthquake. The slosh height obtained through Computational Fluid dynamics (CFD) is compared the values given by TID-7024 (Housner 1963) and American concrete institute (ACI) seismic codes. An equivalent amplitude method is used to compute the slosh height through CFD. Numerically computed slosh height for first mode of vibration is found to be in agreement the codal values. The combined effect in longitudinal and lateral directions are studied separately, and found that the slosh height is increased by 24.3% and 38.9% along length and width directions respectively. There is no liquid spillage under SSE level of earthquake data in SFSB and TLB at convective level and at free surface acceleration data. Since seismic design codes do not have guidelines for combined excitations and effect of higher modes for irregular geometries, this CFD procedure can be opted for any geometries to study effect of higher modes and combined three directional excitations.

Classification of Grid Connected Transformerless PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families

  • Ozkan, Ziya;Hava, Ahmet M.
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.256-267
    • /
    • 2015
  • Grid-connected transformerless photovoltaic (PV) inverters (TPVIs) are increasingly dominating the market due to their higher efficiency, lower cost, lighter weight, and reduced size when compared to their transformer based counterparts. However, due to the lack of galvanic isolation in the low voltage grid interconnections of these inverters, the PV systems become vulnerable to leakage currents flowing through the grounded star point of the distribution transformer, the earth, and the distributed parasitic capacitance of the PV modules. These leakage currents are prohibitive, since they constitute an issue for safety, reliability, protection coordination, electromagnetic compatibility, and module lifetime. This paper investigates a wide range of multi-kW range power rating TPVI topologies and classifies them in terms of their leakage current attributes. This systematic classification places most topologies under a small number of classes with basic leakage current attributes. Thus, understanding and evaluating these topologies becomes an easy task. In addition, based on these observations, new topologies with reduced leakage current characteristics are proposed in this paper. Furthermore, the important efficiency and cost determining characteristics of converters are studied to allow design engineers to include cost and efficiency as deciding factors in selecting a converter topology for PV applications.

Broadband polarimetric Microstrip Antennas for Space-borne SAR

  • Hong, Lei;Qunying, Zhang;Guang, Fu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.465-470
    • /
    • 2002
  • A novel phased array antenna system for space-borne polarimetric SAR is proposed and completed in this paper.The antenna system assures polarimetric and multi-mode capability of SAR. It has broadband, high polarization isolation and high port to port isolation. The antenna system is composed of broadband polarimetric microstrip antenna, T/R modules and multifunction beam controller nit. The polarimetric microstrip antenna has more than 100MHz bandwidth at L-band with -30dB polarization isolation and high port to port isolation. The microstrip element and T/R module's structure and characteristics, the subarray's performances measuring results are presented in detail in this paper. A design scheme on beam controller of the phased array antenna is also proposed and completed, which is based on Digital Signal Processing (DSP) chip -TMS320F206. This beam controller unit has small size and high reliability compared with general beam controller. In addition, the multifunction beam controller unit can acquire and then send the T/R module's working states to detection system in real time.

  • PDF

A Receiver-Aided Seamless And Smooth Inter-RAT Handover At Layer-2

  • Liu, Bin;Song, Rongfang;Hu, Haifeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권10호
    • /
    • pp.4015-4033
    • /
    • 2015
  • The future mobile networks consist of hyper-dense heterogeneous and small cell networks of same or different radio access technologies (RAT). Integrating mobile networks of different RATs to provide seamless and smooth mobility service will be the target of future mobile converged network. Generally, handover from high-speed networks to low-speed networks faces many challenges from application perspective, such as abrupt bandwidth variation, packet loss, round trip time variation, connection disruption, and transmission blackout. Existing inter-RAT handover solutions cannot solve all the problems at the same time. Based on the high-layer convergence sublayer design, a new receiver-aided soft inter-RAT handover is proposed. This soft handover scheme takes advantage of multihoming ability of multi-mode mobile station (MS) to smooth handover procedure. In addition, handover procedure is seamless and applicable to frequent handover scenarios. The simulation results conducted in UMTS-WiMAX converged network scenario show that: in case of TCP traffics for handover from WiMAX to UMTS, not only handover latency and packet loss are eliminated completely, but also abrupt bandwidth/wireless RTT variation is smoothed. These delightful features make this soft handover scheme be a reasonable candidate of mobility management for future mobile converged networks.