• 제목/요약/키워드: multi-level damper

검색결과 20건 처리시간 0.018초

다목적 유전자 알고리즘을 이용한 퍼지제어기의 설계 (Design of Fuzzy Controller using Multi-objective Genetic Algorithm)

  • 김현수;;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2005
  • The controller that can control the smart base isolation system consisting of M damper and friction pendulum systems(FPS) is developed in this study. A fuzzy logic controller (FLC) is used to modulate the M damper force because the FLC has an inherent robustness and ability to handle non-linearities and uncertainties. A genetic algorithm (GA) is used for optimization of the FLC. When earthquake excitations are applied to the structures equipped with smart base isolation system, the relative displacement at the isolation level as well as the acceleration of the structure should be regulated under appropriate level. Thus, NSGA-II(Non-dominated Sorting Genetic Algorithm) is employed in this study as a multi-objective genetic algorithm to meet more than two control objectives, simultaneously. NSGA-II is used to determine appropriate fuzzy control rules as well to adjust parameters of the membership functions. Effectiveness of the proposed method for optimal design of the FLC is judged based on computed responses to several historical earthquakes. It has been shown that the proposed method can efficiently find Pareto optimal sets that can reduce both structural acceleration and base drift from numerical studies.

  • PDF

High-rise Reinforced-concrete Building Incorporating an Oil Damper in an Outrigger Frame and Its Vibration Analysis

  • Omika, Yukihiro;Koshika, Norihide;Yamamoto, Yukimasa;Kawano, Kenichi;Shimizu, Kan
    • 국제초고층학회논문집
    • /
    • 제5권1호
    • /
    • pp.43-50
    • /
    • 2016
  • The reinforced-concrete multi-story shear-wall structure, which can free a building from beams and columns to allow the planning of a vast room, has increasingly been used in Japan as a high-rise reinforced-concrete structure. Since this structural system concentrates the seismic force onto multi-story shear walls inside, the bending deformation of the walls may cause excessive deformation on the upper floors during an earthquake. However, it is possible to control the bending deformation to within a certain level by setting high-strength and rigid beams (outriggers) at the top of the multi-story shear walls; these outriggers restrain the bending behavior of the walls. Moreover, it is possible to achieve high energy dissipation by placing vibration control devices on the outriggers and thus restrain the bending behavior. This paper outlines the earthquake response analysis of a high-rise residential tower to demonstrate the effectiveness of the outrigger frame incorporating vibration control devices.

와전류 제동장치 설계검증을 위한 동역학적 해석 (Dynamic analysis of eddy current brake system for design evaluation)

  • 정경렬;김경택;백진성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.110-115
    • /
    • 2002
  • In this paper, the results of an analysis of the dynamic behavior of the eddy current brake(ECB) system are presented. The measured irregularity of the track in Korean high speed line and the track irregularity given by ERRI(high level) were used for simulation. The wheel-rail profile combination were analyzed with different rail gauges. A model of the bogie with an substitute body for the carbody was implemented in the Multi-body-Simulation Program SIMPACK. The ECB frame was modelled both as flexible body and as rigid body. Four different driving conditions were analyzed. In this study dynamic behavior in general were performed to evaluate the design of eddy current brake system and specially the effect of damper was also studied. A comparison of simulations with and without damper shows that the damper have most effect for lower speed. The simulation results will be verified by comparison with measured data from on line test and also used for improving design.

  • PDF

벽체-감쇠 복합시스템을 갖는 건물의 지진취약도 분석 (Seismic Fragility Analysis of Buildings With Combined Shear Wall-Damper System)

  • 라지불 이슬람;수딥타 차크라보르티;공병진;김두기
    • 한국지진공학회논문집
    • /
    • 제27권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.

Evaluation of the effect of smart façade systems in reducing dynamic response of structures subjected to seismic loads

  • Samali, Bijan;Abtahi, Pouya
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.983-1000
    • /
    • 2016
  • To date the engineering community has seen facade systems as non-structural elements with high aesthetic value and a barrier between the outdoor and indoor environments. The role of facades in energy use in a building has also been recognized and the industry is also witnessing the emergence of many energy efficient facade systems. This paper will focus on using exterior skin of the double skin facade system as a dissipative movable element during earthquake excitation. The main aim of this study is to investigate the potential of the facade system to act as a damper system to reduce earthquake-induced vibration of the primary structure. Unlike traditional mass dampers, which are usually placed at the top level of structures, the movable/smart double skin facade systems are distributed throughout the entire height of building structures. The outer skin is moveable and can act as a multi tuned mass dampers (MTMDs) that move and dissipate energy during strong earthquake motions. In this paper, using a three dimensional 10-storey building structure as the example, it is shown that with optimal choice of materials for stiffness and damping of brackets connecting the two skins, a substantial portion of earthquake induced vibration energy can be dissipated which leads to avoiding expensive ductile seismic designs. It is shown that the engineering demand parameters (EDPs) for a low-rise building structures subjected to moderate to severe earthquakes can be substantially reduced by introduction of a smart designed double skin system.

Performance-based seismic design of a spring-friction damper retrofit system installed in a steel frame

  • Masoum M. Gharagoz;Seungho Chun;Mohamed Noureldin;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제51권2호
    • /
    • pp.173-183
    • /
    • 2024
  • This study investigates a new seismic retrofit system that utilizes rotational friction dampers and axial springs. The retrofit system involves a steel frame with rotational friction dampers (RFD) at beam-column joints and linear springs at the corners, providing energy dissipation and self-centering capabilities to existing structures. The axial spring acts as a self-centering mechanism that eliminates residual deformations, while the friction damper mitigates seismic damage. To evaluate the seismic performance of the proposed retrofit system, a series of cyclic loading tests were carried out on a steel beam-column subassembly equipped with the proposed devices. An analytical model was then developed to validate the experimental results. A performance point ratio (PPR) was presented to optimize the design parameters of the retrofit system, and a performance-based seismic design strategy was developed based on the PPR. The retrofit system's effectiveness and the presented performance-based design approach were evaluated through case study models, and the analysis results demonstrated that the developed retrofit system and the performance-based design procedure were effective in retrofitting structures for multi-level design objectives.

Robust multi-objective optimization of STMD device to mitigate buildings vibrations

  • Pourzeynali, Saeid;Salimi, Shide;Yousefisefat, Meysam;Kalesar, Houshyar Eimani
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.347-369
    • /
    • 2016
  • The main objective of this paper is the robust multi-objective optimization design of semi-active tuned mass damper (STMD) system using genetic algorithms and fuzzy logic. For optimal design of this system, it is required that the uncertainties which may exist in the system be taken into account. This consideration is performed through the robust design optimization (RDO) procedure. To evaluate the optimal values of the design parameters, three non-commensurable objective functions namely: normalized values of the maximum displacement, velocity, and acceleration of each story level are considered to minimize simultaneously. For this purpose, a fast and elitist non-dominated sorting genetic algorithm (NSGA-II) approach is used to find a set of Pareto-optimal solutions. The torsional effects due to irregularities of the building and/or unsymmetrical placements of the dampers are taken into account through the 3-D modeling of the building. Finally, the comparison of the results shows that the probabilistic robust STMD system is capable of providing a reduction of about 52%, 42.5%, and 37.24% on the maximum displacement, velocity, and acceleration of the building top story, respectively.

하지 절단자를 위한 다축 회전이 가능한 인공발의 개발 (Development of Multi-rotational Prosthetic Foot for Lower Limb Amputee)

  • 신현준;박진국;조현석;류제청;김신기
    • 재활복지공학회논문지
    • /
    • 제10권4호
    • /
    • pp.305-313
    • /
    • 2016
  • 두 발을 번갈아 옮기며 몸을 앞으로 움직이는 단순한 동작의 반복으로 보이는 보행이란 과정은 실제 인체 내의 대부분의 근육 및 인대, 뼈가 연관되어 이루어지는 복잡한 행동이다. 신체 일부가 소실된 하퇴 절단자의 경우 생체조직이 온전히 보전되어 있는 일반인과는 달리 남은 생체 부위와 의지의 공학적인 성능에만 의존해 보행을 해야 한다는 어려운 상황에 직면하게 된다. 따라서 하퇴절단자를 위한 하퇴의지는 우선 환자가 기본적인 보행이 가능케 함과 동시에 최대한 복잡한 지면 상태에 적응할 수 있도록 설계가 되어야 한다. 원활한 보행을 위해서는 배/저굴 방향의 발목의 회전이 매우 중요하고 고르지 못한 지면 상태를 극복하기 위해서는 내/외전 방향의 족부의 회전 기능이 요구된다. 최근 생체역학적인 연구를 접목한 다양한 하퇴의지가 개발되고 있으나, 이러한 고가의 고성능 하퇴의지의 경우 주로 활동성이 높은 하지절단 환자들에 초점이 맞춰져 있다. 본 연구에서는 하퇴의지 착용자의 대다수인 활동성이 낮은 K2 레벨의 환자들을 위한 하퇴의지를 개발했다. 기본적인 보행 능력 향상을 위해서 배/저굴 방향으로의 회전이 가능한 유압식 발목을 개발했고, 이를 통해서 배/저굴 방향으로 각각 $2.5^{\circ}$$4^{\circ}$의 회전이 가능함을 확인했다. 또한 수동 조절이 가능한 유압 노즐을 탑재해 환자 개개인에 적합한 발목 회전 저항력을 설정할 수 있도록 설계했다. 내/외전 방향으로의 족부의 회전이 가능하도록 이중고무 방식의 중간재를 삽입해 각각 $3.6^{\circ}$$4.1^{\circ}$의 회전이 가능하도록 설계되어 측경사나 작은 장애물들을 극복할 수 있도록 제작했다. 본 연구를 통해 개발된 하퇴의지는 K2 레벨의 하퇴절단자들이 일상생활 중에 겪게 되는 다양한 지면 환경을 극복하는데 도움을 줄 것이다.

퍼지관리제어기법을 이용한 스마트 면진 벤치마크 건물의 제어 (Control of Smart Base-isolated Benchmark Building using Fuzzy Supervisory Control)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권4호
    • /
    • pp.55-66
    • /
    • 2005
  • 본 논문에서는 스마트 면진장치를 효과적으로 제어하기 위하여 퍼지관리제어기를 개발하였고 그 효율성을 검토하였다. 이를 위하여 1세대 스마트 면진 벤치마크 건물을 이용하여 수치해석을 수행하였다. 대상 벤치마크 구조물은 부정형의 평면을 가지고 있는 8층 건물이고 탄성베어링과 MR 감쇠기로 이루어진 스마트 면진장치가 설치되어 있다. 본 논문에서는 다목적 유전자 알고리즘을 이용하여 원거리 지진과 근거리 지진에 대하여 각각 면진구조물을 효과적으로 제어할 수 있는 하위 퍼지제어기를 개발한다. 최적화과정에서는 구조물의 최대 및 RMS 가속도와 면진층 변위의 저감이 목적으로 사용된다. 벤지마크 건물에 지진하중이 가해지면 두 개의 하위 퍼지제어기에서는 각각 다른 명령전압이 제공되는데 이 명령전압들은 퍼지관리제어기의 추론과정에 기반하여 실시간으로 참여율이 조절되어 하나의 명령전압으로 조합된다. 수치해석을 통하여 제안된 퍼지관리제어기법을 사용함으로써 상부구조물의 응답과 면진층의 변위를 효과적으로 줄일 수 있음을 확인할 수 있다.

Landing Stability Simulation of a 1/6 Lunar Module with Aluminum Honeycomb Dampers

  • Pham, Van Lai;Zhao, Jun;Goo, Nam Seo;Lim, Jae Hyuk;Hwang, Do-Soon;Park, Jung Sun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권4호
    • /
    • pp.356-368
    • /
    • 2013
  • The Korea Aerospace Research Institute plans to launch a lunar module by 2025, and so is carrying out a preliminary study. Landing stability on the lunar surface is a key design factor of a lunar module. In this paper, a 1/6 scale model of a lunar module is investigated, for its landing stability on non-level surfaces. The lunar module has four tripod legs, with aluminum honeycomb shock absorbers in each leg strut. ADAMS$^{TM}$, the most widely used multi-body dynamics and motion analysis software, is used to simulate the module's lunar landing. Three types of dampers in the struts (rigid, viscous, and aluminum honeycomb dampers), and two types of lunar surfaces (rigid and elastic) are considered. The Sforce function is adopted, to model the aluminum honeycomb dampers. Details on the modeling and analysis of the landing stability of the 1/6 scale lunar module and the simulation results are provided in this paper.