• Title/Summary/Keyword: multi-filtration

Search Result 75, Processing Time 0.031 seconds

An Experimental Study on the Performance of Multi-Diameter Lateral for Riverbed Filtration (하상여과용 다직경 수평집수관의 효능에 대한 실험연구)

  • Bae, Gha-Ram;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.359-364
    • /
    • 2012
  • In order to prevent the decrease in well efficiencies due to friction in the axial flow in long, large-diameter laterals, a multi-diameter lateral was devised and tested through lab-scale sand-box experiments to assess its performance. In the experiment, three different production rates were applied over the multi-diameter and the three single-diameter laterals to obtain the hydraulic head distributions for each, which was used to assess the performance of the laterals. Results elucidated that the multi-diameter lateral reduced the material cost by more than a third, in comparison to the single-diameter lateral, while maintaining the production rate at higher than 93%, proving its superiority. Furthermore, results indicated that exit velocities exceeding 0.8 m/sec in horizontal wells tended to distort the hydraulic head distribution near the exit, providing evidence of its inefficiency.

A Comparison of Performance Evaluations of Reusable Masks (다회용 마스크 유형에 따른 성능 비교연구)

  • Ryu, Hoe-Jin;Park, Won-Hee;Lee, Chun-Yeong;Jeong, Seon-Ok;Choi, Hee-Jin;Lee, Jeong-Mi;Hwang, In-Sook;Shin, Yong-Seung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.53-63
    • /
    • 2022
  • Objectives: This study was designed to evaluate the filtration efficiency, inhalation resistance, and liquid resistance of commercial reusable masks in comparison to the performance of KF-AD masks (reference masks). Methods: Thirty-six masks were purchased from an online market. Filtration efficiency and inhalation resistance were determined in the same manner as in MFDS certification testing, respectively using TIL/IL & Filter Test 1300S (SFP Services, UK) and Breathing Resistance Analyzer DA2001 (Lambda Ray, South Korea). Results: Most of the filtration efficiencies found for the 19 masks were far lower than the test standard for KF-certified masks. Four masks met KF94 and three masks even met KF80. Most inhalation resistances were also much lower than the standard, with many almost one-half of the standard. In addition, all the masks except KF-AD masks did not pass the liquid resistance test. Conclusions: Although most of the filtration efficiency performance results found in this study for the reusable masks, which emerged as an alternative, were lower than the standard for health masks, multi-use masks can be used with a replacement filter inserted.

Influences of Detention Time, Particle Size Distribution, and Filter Medium on Waterworks Sludges Dewatering (체류시간, 입도분포 및 여재가 정수 슬러지의 탈수에 미치는 영향)

  • Kim, Kwang-Soo;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.121-128
    • /
    • 2009
  • Objectives of this study were to investigate influencing factors of detention time, particle size distribution, and filter medium characteristics for waterworks sludge dewatering. The stepped pressure filtration was carried out with lab scale apparatus and the filter press pilot test for dewatering was conducted at the water treatment plant. Effects of filter medium and polymer dose were examined through observing water content and dewatering velocity and cyclic dewatering rate with filter press pilot test. Relationships among detention time, particle size distribution and filtration resistance were analyzed. Prolongation of sludge detention time was found to cause blinding phenomenon in cake and filter medium and to decrease dewatering process efficiency. The average specific resistance increased according to detention time. In pilot test of dewatering for thickened sludge with Nylon Multi-NY840D and Nylon Mono-100% filter media, dewatering velocities were 0.92 and $0.93kg\;DS/m^2{\cdot}hr$ according to 0.1% polymer dose of dried solids weight base. And cyclic dewatering rates were 2.45 and $2.50kg\;DS/m^2{\cdot}cycle$ cycle for the Nylon Multi-NY840D and Nylon Mono-100% media. Dewatering velocity of polymer dosed sludge was observed to be higher than that of non-polymer sludge.

Study of Multi-Walled Carbon Nanotube Synthesis Using Liquid Nitrogen and Post-Process Filtration

  • Sornsuwit, Nuttaphong;Maaithong, Worawut
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.18-21
    • /
    • 2008
  • The study deals with the effects of parameters in the synthesis of carbon nanotubes in liquid nitrogen to find the most appropriate conditions such as electrical voltage and time that give carbon nanotubes with large volume and less proportion of impurity, which is a non-nanotubed carbon. The experiment employed the method of arc-discharge between graphite cathode and anode which are immersed in liquid nitrogen. The electrical DC current of 60A and 70A were applied with the time period ranging from 10 seconds to 25 seconds. It was found that the electrical current of 60A and 13 seconds arc-discharge time allowed the largest volume of carbon nanotubes generation. The longer time leads to more impurities around the carbon nanotubes. By the filtration of CNTs-suspended solution using 0.2 micrometers porous paper filter and the characterization using TEM, the carbon nanotubes synthesized in the study were approximately 25 layers multi-walled nanotubes with the average diameter of 18.2 nanometers.

Fabrication of Porous Ceramic Materials for Biomedical and Environmental Applications

  • Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.18.2-18.2
    • /
    • 2009
  • Ceramics have some properties that are unmatched by other kind of materials like metals or polymers. The ability of high thermal and chemical resistance and in case of being superior in specific mechanical properties makes the ceramic materials suitable for arange of applications. The microstructure and morphology of a material arguably permit the use of many advanced application otherwise difficult to achieve.Porous structures have some important applications in biomedical and environmental field. For human hard tissue reconstruction and augmentation procedure suitable biomaterials are used with a desirable porosity. A range of porous bioceramics were fabricated with tailored design to meet the demand of specific applications. Channeled and interconnected porosity was introduced in alumina, zirconia, and hydroxyapatite or tri calcium phosphate ceramics by different methods like multi-pass extrusion process, bubble formation in viscous slurry,slurry dripping in immiscible liquid, sponge replica method etc. The detailed microstructural and morphological investigations were carried out to establish the unique features of each method and the developed systems. For environmental filters the porous structures were also very important. We investigated a range of channeled and randomly porous silicon based ceramic composites to enhance the material stability and filtration efficiency by taking advantage of the material chemistry of the element. Detailed microstructural and mechanical characterizations were carried out for the fabricated porous filtration systems.

  • PDF

Role of Detached Particles During Initial Filtration Phase (여과초기에서의 탈착된 입자의 거동)

  • Kim, Ja-Kyum;Tobiason, John E.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters (충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측)

  • Jang, Kyeong-Min;Jung, Eun-Sang;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

Design and operating parameters of multi-functional floating island determined by basic experiments of unit processes (단위공정별 기초실험을 통한 다기능 융복합부도의 설계·운전인자 도출)

  • Lim, Hyun-Man;Jang, Yeo-Ju;Jung, Jin-Hong;Yoon, Young-Han;Park, Jae-Roh;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.487-497
    • /
    • 2018
  • Water quality improvement processes for stagnant area consist mainly of technologies applying vegetation and artificial water circulation, and these existing technologies have some limits to handle pollution loads effectively. To improve the purification efficiency, eco-friendly technologies should be developed that can reinforce self-purification functions. In this study, a multi-functional floating island combined with physical chemical biological functions ((1) flotation and oxidization using microbubbles, (2) vegetation purification and (3) bio-filtration with improved adsorption capacity) has been developed and basic experiments were performed to determine the optimal combination conditions for each unit process. It has been shown that it is desirable to operate the microbubble unit process under conditions greater than $3.5kgf/cm^2$. In vegetation purification unit process, Yellow Iris (Iris pseudacorus) was suggested to be suitable considering water quality, landscape improvement and maintenance. When granular red-mud was applied to the bio-filtration unit process, it was found that T-P removal efficiency was good and its value was also stable for various linear velocity conditions. The appropriate thickness of filter media was suggested between 30 and 45 cm. In this study, the optimal design and operating parameters of the multi-functional floating island have been presented based on the results of the basic experiments of each unit process.

Study on Multi-Dimensional Simulation of the Flow and Filtration Characteristics in Diesel Particulate Filters (DPF의 배기가스 유동 및 포집에 관한 다차원 모델링 연구)

  • Kim, Dong-Kyun;Yoon, Cheon-Seog
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.3
    • /
    • pp.60-68
    • /
    • 2010
  • In order to understand the flow and filtration characteristics in a wall-flow type DPF(Diesel Particulate Filter), 0-D, 1-D, and 3-D simulations are preformed. In this paper, three model are explained and validated with each other. Based on the comparisons with 1-D and 3-D results for the steady state solution, 3-D CFD analysis is preferable to 1-D for the prediction of wall velocity at the inlet and exit plane. Because PM loading process is transient state phenomena, the combination of full 3-D and time dependent simulation is crucial for the configuration of wall channels. New coupling technique, which is the connection between calculated permeability from 0-D lumped parameter model and UDF(User Defined Functions) of main solver, is proposed for the realisti

Comparison of Evaluation Methods for Disinfection Efficacy of Contact Lens Care Products (콘택트렌즈 관리용품의 살균력 효능 검사법 비교)

  • Sung, Hyung Kyung;Byun, Hyun Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose: The present study was aimed to compare the results of disinfection efficacy tested by membrane filtration method with dilution-neutralization method to develop the standard methods for evaluating disinfection efficacy of contact lens care products and to provide the result of disinfection efficacy of commercially available contact lens care products in domestic market. Methods: The results of disinfection efficacy against Staphylococcus aureus, Pseudomonas aeruginosa, Serratia marcescens, Candida albicans evaluated by membrane filtration method as a FDA standard and dilution-neutralization method as newly being a KFDA standard were compared and the disinfection efficacy of 16 multi-purpose solutions was further evaluated. Results: The disinfectants and contact lens care products having strong disinfection efficacy showed same results in both membrane filtration method and dilution-neutralization method. In case of contact lens care products having weak disinfection efficacy, the number of micro-organisms was not able to count since the colony was aggregated when evaluated by membrane filtration method. However, the number of micro-organisms was able to exactly count when evaluated by dilution-neutralization method. In addition, some commercially available contact lens care products did not meet disinfection standard and especially, their disinfection effect was often weak against Serratia marcescen and Candida albicans. Conclusions: It is concluded that dilution-neutralization method will be useful to evaluate disinfection efficacy since it is possible to count micro-organisms more precisely even with small amount of sample and check the results faster compared with membrane filtration method.