• 제목/요약/키워드: multi-detector computed tomography

검색결과 85건 처리시간 0.021초

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

간 이식편의 체적 예측을 위한 2점 이용 간 분리 (Liver Splitting Using 2 Points for Liver Graft Volumetry)

  • 서정주;박종원
    • 정보처리학회논문지B
    • /
    • 제19B권2호
    • /
    • pp.123-126
    • /
    • 2012
  • 본 논문은 생체간이식 전에 복부 MDCT(Multi-Detector Computed Tomography) 영상에서 간 이식편의 체적을 간단하고 정확하게 계산하기 위하여 좌간과 우간을 나누는 방법을 제안하였다. 본 알고리즘은 기증자와 수혜자의 안전을 보장하기 위하여 시스템과 의료진의 상호작업을 최소화 하여 의료진이 수술 전 이식편의 판단을 정확하게 처리할 수 있도록 하였다. 간이 추출된 영상에 좌간과 우간을 나눌 수 있는 2점(중간 정맥(MHV: Middle Hepatic Vein) 내부의 한 점과 좌우문맥(PV: Portal Vein) 분지부에서 한 점)을 선택한다. 선택된 중간정맥 내부의 점을 이용하여 중간정맥을 자동 인식한 후 중간정맥을 기준으로 절개선을 결정하여 문맥 분지부의 한 점을 연결하는 절개면을 형성한다. 좌간과 우간의 체적과 간 전체에 대한 좌우간의 비율을 계산한다. 계산된 체적의 정확성을 입증하기 위해 진단 방사선과 의사가 수동으로 처리하여 계산한 체적과 함께 수술 중 획득한 실측무게와 비교하였다. 실측무게와 수동으로 예측된 체적 사이의 오차에 대한 평균${\pm}$표준편차는 $162.38cm^3{\pm}124.39$이고, 실측무게와 2점을 이용하여 예측된 체적과의 오차에 대한 평균${\pm}$표준편차는 $107.69cm^3{\pm}97.24$이다. 실측무게와 수동으로 예측된 체적의 상관관계는 0.79이고, 실측무게와 2점을 이용하여 예측된 체적의 상관관계는 0.87이다. 그리고 2점을 선택한 후 좌우간을 분할하여 체적을 계산하는 시간을 측정하여 수술실에서 실시간으로 처리 가능한지의 여부를 확인하였다. 한 데이터세트($149.17pages{\pm}55.92$) 당 처리 시간의 평균${\pm}$표준편차는 $57.28sec{\pm}32.81$이다.

두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가 (Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.131-140
    • /
    • 2003
  • 3차원 영상의 해부학 구조에 대한 정확한 거리 측정은 중요한 역할을 하고 있으므로, 인체 두개골 팬텀을 사용하여 다검출기 CT에서의 슬라이스 두께별 획득 변수에 따른 3차원 영상의 정량적 특성에 관하여 거리 측정방법에 의한 정확도 평가를 실시하였다. 두개골 팬텀의 외부에 임상적으로 중요한 의미를 갖는 21 개의 위치를 표시하고 각 점간의 거리를 실측하였다. 실측한 데이터는 3차원 재구성 영상의 계측값과 비교평가 하기 위한 기준으로 삼았다. 다검출기 CT를 사용하여 200 mA, 120 kVp의 X-선 튜브 조건과 갠트리 회전 당 스캔(scan) 시간 1초로 단면영상을 획득하였다. 축형 모드와 나선형 모드(pitch 3:1, 6:1)에서 각각 1.25 mm, 2.50 mm, 3.75 mm, 5.00 mm의 슬라이스 두께로 획득하였고, 나선형 모드에서 획득된 단면영상을 다시 1.25 mm로 획득하였다. 영상분석 소프트웨어를 이용하여 3차원 영상 재구성 및 거리측정을 하고 통계분석을 실시하였다. 1.25 mm, 2.50 mm, 3.75 mm, 5.00 mm의 계측값의 정확도는 각각 48%, 33%, 23%, 14%로 나타났으며 1.25 mm로 재구성한 3차원 영상의 정확도는 각각 53%, 41%, 43%, 36%로 나타났다. 그러나, 1.25 mm로 재구성한 3차원영상들 간의 거리측정의 정확도 사이에서 통계적으로 유의할 만한 수준(P-value<0.05)의 차이는 보이지 않았다. 다검출기 CT의 영상획득 변수에 따른 3차원 재구성 영상에서의 각 점간의 거리측정 결과는 피치나 스캔 모드에서 보다 슬라이스 두께와 재구성 슬라이스 두께에 따른 영향이 더욱 크다는 것을 나타내었다.

  • PDF

폐색전증이 의심된 환자에서 두 가지 폐색전증 진단 예측 모형의 평가 (Assessment of Two Clinical Prediction Models for a Pulmonary Embolism in Patients with a Suspected Pulmonary Embolism)

  • 박재석;최원일;민보람;박지혜;채진녕;전영준;유호정;김지영;김경주;고성민
    • Tuberculosis and Respiratory Diseases
    • /
    • 제64권4호
    • /
    • pp.266-271
    • /
    • 2008
  • 연구배경: 급성 폐색전증의 발생을 예측하는 Wells 및 Geneva 예측 모형은 서구에서 잘 확립되어 있다. 폐색전증의 역학이 서구와 다를 것으로 보이는 국내에서의 예측모형의 유용성에 대해서 평가 하고자 한다. 방법: 단일 의료기관에서 폐색전증 의심 하에 multi-detector computed tomography (MDCT)를 시행한 환자 210명을 대상으로 후향적으로 조사하였다. 성별 구성은 남자 90명(42.9%), 여자 120명(57.1%)이었고, 평균 연령은 $63.3{\pm}15.9$세였다. 의무기록을 바탕으로 Wells 및 개정된 Geneva 예측 모형으로 폐색전증의 가능성에 대해 저위험군, 중등도 위험군, 고위험군으로 분류하였다. 결과: 폐색전증으로 진단된 환자는 210명 중 41명(19.5%)이었다. Wells 예측 모형을 적용한 폐색전증 발병 가능성 평가에서는, 2명(1%)이 저위험군, 137명(62.5%)이 중등도 위험군, 71명(3.8%)이 고위험군으로 분류되었고, 각 군에서 폐색전증의 발생률은 10%, 18.2%, 19.7%였다. 개정된 Geneva 예측 모형을 적용할 경우 44명(21%)이 저위험군, 160명(76.2%)이 중등도 위험군, 6명(2.8%)이 고위험군으로 분류되었고, 각 군에서 폐색전증의 발생률은 4.5%, 2.5%, 50%로 나타났다. Receiver operating characteristic (ROC) 곡선 분석에서 개정된 Geneva 예측 모형이 Wells 예측 모형에 비해 정확도가 높았다. 두 예측 모형 사이의 일치율은 불량했다($\kappa$ coefficient=0.06). 결론: 본 연구에서는 폐색전증이 의심되는 환자에서 개정된 Geneva 예측모형과 Wells 예측 모형으로 평가하여 두 모형 사이에 일치율이 불량하였으며, 개정된 Geneva 모형이 Wells 모형에 비해 폐색전증 진단 예측이 더 정확하였다.

MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가 (The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography))

  • 류귀복;김현수;유광열;동경래;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.127-132
    • /
    • 2010
  • 본 연구의 목적은 MDCT의 iso-center에서 detector의 Z-축 범위 이외에서 발생하는 산란선을 측정하고 산란선을 경감하기 위한 기준설정에 기초 자료를 제시하고자 하는 것이다. MDCT의 발전은 환자 Z-축으로의 빔의 확대를 가져오게 되었으며 이는 산란선의 증가로 이어져 피폭선량의 증가에 기여하게 되었다. 또한 MDCT는 SDCT에 비하여 빔 두께의 차이에 따라 최고 4배까지 산란선이 증가하고 있다. MDCT에서 빔 두께 변화에 따른 산란선을 평가하기 위하여 16-slice CT 1대, 64-slice CT 2대의 장비를 이용하여 다배열검출기(MDCT)의 Z-축의 넓이에 따른 산란선을 측정하였다. 측정 장비로는 이온챔버 60 ml 2026C를 사용하였다. 측정결과 장비 별 빔 두께에 따른 산란선의 변화는 동일한 kVp에서 빔 두께가 2배 증가함에 따라 평균 1.7~1.8배의 산란선의 증가가 있었다. 또한 관전압에 따른 산란선의 변화를 평가한 결과 관전압이 80 kVp에서 120 kVp로 40 kVp 증가함에 따라 64 slice 장비에서는 평균 3.47~3.79배의 산란선 증가가 있었고 16 slice 장비에서는 평균 2.47배의 산란선 증가가 있었다. 마지막으로 iso-center로부터의 거리변화에 따른 산란선을 측정한 결과 이온챔버의 거리가 2배 증가함에 따라 2.11~2.25배의 산란선 감소가 있었다. 본 연구는 의료영상 진단 장비인 CT 장비의 Z-축 빔 두께 증가와 관전압, 거리에 따른 산란선을 평가하는데 있다. 이에 따라 뇌 CT 검사 시 갑상선, 안구 등의 차폐문제와 복부 CT 검사 시 갑상선, 생식선 등의 차폐문제가 무시할 수 없음을 알 수 있었다. 현재 슬라이스 내의 선량에 대한 연구가 주로 이루어지고 있는 시점에서 본 연구를 통하여 detector의 Z-축빔 두께 증가에 따른 Z-축 범위 이외의 산란선의 증가를 이해하고, 검사목적 부위 이외의 산란선 연구에 대한 필요성과 MDCT를 이용한 CT 검사 시 차폐의 중요성을 인식하여야 한다.

MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정 (Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT)

  • 이창래;전성수;남소라;조효민;정지영;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.139-143
    • /
    • 2007
  • 본 연구는 MDCT (multi-detector computed tomography) 파라미터 변화에 따른 환자선량을 측정하고 평가 하고자 하였다. MDCT 파라미터의 다양한 변화에 의한 환자선량은 MDCT (GE light speed plus 4 slice, USA)와 model 2026C electrometer (RADICAL 2026C, USA), 그리고 head와 body의 CT선량 표준팬텀(standard polymethylmethacrylate)을 사용하여 측정 하였다. 그 결과 환자선량 $CTDI_w$ 값은 관전압과 관전류가 증가할수록 선형적으로 증가하였고 beam collimation이 증가 할수록 감소하였다. 따라서 관전압, 관전류는 환자의 피폭선량에 직접적인 영향을 주고 슬라이스 두께는 영향이 적은 것을 알 수 있었다. 임상의 전형적인 MDCT 복부 scan에서 120 kVp, 180 mAs, 20 mm collimation과 0.75 pitch의 조건하에 $CTDI_w$$CTDI_{vol}$의 측정값은 각각 20.2 mGy, 26.9 mGy이었고 스캔 길이가 271.3 mm인 환자의 DLP와 유효선량은 각각 $729.1\;mGy{\cdot}cm$, 10.9 mSv였다.

  • PDF

과급 횡복직근피판술(Supercharged TRAM)을 이용한 유방재건술 (Supercharged Technique in TRAM flap Breast Reconstruction)

  • 양정덕;송재민;이상윤;정호윤;조병채;박호용;정진향
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.577-582
    • /
    • 2010
  • Purpose: When reconstruction for patients who have the large contralateral breast or a following large defect after mastectomy is required, conventional pedicled TRAM flap shows the unpredictable occurrence of fat necrosis and skin flap loss in a relatively high percentage due to insufficient blood supply. In an effort to obtain more stable TRAM flap blood circulation, we have performed a supercharged technique using deep inferior epigastric perforators (DIEP) with conventional pedicled TRAM flap. Methods: From September of 2006 to December of 2008, Fourteen supercharged TRAM flap were performed for breast reconstruction after modified radical mastectomy. The contralateral DIEP was anastomosed to the internal mammary vessels in contralateral pedicled TRAM flap or thoracodorsal vessels in ipsilateral pedicled TRAM flap. Nutrient vessels were selected by Multi-Detector Computed tomography (MD-CT) modalities. For the nutrient vessel, we used deep inferior epigastric vessels (DIEV) of the ipsilateral side in 8 patients, DIEV of the contralateral side in 6 patients. In addition, for the recipient vessel, we used thoracodorsal vessels in 8 patients, internal mammary vessels in 5 patients, intercostals artery perforators in 1 patient. Results: The mean age was 46.8 years and the average follow-up interval was 14 months. There were 11 immediate and 3 delayed breast reconstructions. Fat necrosis incidence rate in supercharged TRAM group was lower than in conventional TRAM flap group. There were no differences of the incidences of abdominal hernia in both groups. Conclusion: The supercharged TRAM flap produces an improvement in vascularity that permits use of all four zones of the flap. The breast reconstruction with supercharged technique is reliable and valuable methods which provide sufficient soft tissue from abdomen without significant complications.

The preliminary study for three-dimensional alveolar bone morphologic characteristics for alveolar bone restoration

  • Cho, Hyun-Jae;Jeon, Jae-Yun;Ahn, Sung-Jin;Lee, Sung-Won;Chung, Joo-Ryun;Park, Chang-Joo;Hwang, Kyung-Gyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.33.1-33.7
    • /
    • 2019
  • Background: The concept of the ideal morphology for the alveolar bone form is an important element to reconstruct or restore the in maximizing esthetic profile and functional alveolar bone restoration. The purpose of this preliminary study is to evaluate the normal alveolar bone structure to provide the standard reference and guide template for use in diagnosing for implant placement, determining the correct amount of bone augmentation in actual clinical practice and producing prostheses based on three-dimensional imaging assessment of alveolar bone. Methods: This study was included 11 men and 11 women (average age, 22.6 and 24.5 years, respectively) selected from among 127 patients. The horizontal widths of alveolar bone of maxilla and mandible were measured at the crestal, mid-root, and root apex level on MDCT (multi-detector computed tomography) images reconstructed by medical imaging software. In addition, tooth dimensions of the central incisors, canines, second premolars, and first molars of maxilla and mandible, including the horizontal width of the interdental alveolar bone crest, were also measured and statistically analyzed. Results: The horizontal alveolar bone width of the palatal side of maxilla showed a distinct increment from the alveolar bone crest to the apical region in both anterior and posterior areas. The average widths of the maxillary alveolar ridge were as follows: central incisor, 7.43 mm; canine, 8.91 mm; second premolar, 9.57 mm; and first molar, 12.38 mm. The average widths of the mandibular alveolar ridge were as follows: central incisor, 6.21 mm; canine, 8.55 mm; second premolar, 8.45 mm; and first molar, 10.02 mm. In the buccal side, the alveolar bone width was not increased from the crest to the apical region. The horizontal alveolar bone width of an apical and mandibular border region was thinner than at the mid-root level. Conclusions: The results of the preliminary study are useful as a clinical guideline when determining dental implant diameter and position. And also, these measurements can also be useful during the production of prefabricated membranes and customized alveolar bone scaffolds.

MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가 (Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography)

  • 이후민;유병규;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.71-81
    • /
    • 2008
  • CT 영상은 커널의 종류와 재구성 방법에 따라 다양하게 나타나며, 관심 영역의 CT감약계수 및 노이즈는 정밀도에 영향을 준다. 커널의 종류에 따른 노이즈, 공간분해능 및 MTF를 측정하여 영상을 평가하였다. 다중채널CT 스캐너를 이용하여 팬텀 및 복부를 스캔 하였고, 커널은 B10(very smooth), B20(smooth), B30(medium smooth), B40(medium), B50(medium sharp), B60(sharp), B70(very sharp), B80(ultra sharp)으로 재구성하여 물, 공기, 간의 실질 조직, 근육, 지방 부위를 ROI 기능을 이용하여 평균의 CT감약계수와 표준편차인 노이즈를 정량적으로 측정하여 영상을 비교하였다. 그 결과CT 감약계수는 물($1.1{\sim}1.8\;HU$), 공기($-998{\sim}-1,000\;HU$)이고, 물에서의 노이즈($5.4{\sim}44.8\;HU$), 공기($3.6{\sim}31.4\;HU$)이다. 인체에서 간 실질 조직과 지방, 근육의 CT 감약계수와 노이즈를 커널에 따라 측정하였다. 지방의 CT 감약계수($-2.2{\sim}0.8\;HU$), 간의 실질 조직에서 CT감약계수($60.4{\sim}62.2\;HU$), 노이즈($7.6{\sim}63.8\;HU$), 근육의 CT감약계수($53.3{\sim}54.3\;HU$), 노이즈($10.4{\sim}70.7\;HU$) 사이에서 분포하였고, 커널이 높아질수록 노이즈도 증가하였다. 영상의 질을 높이기 위해서는 검사부위에 따라 노이즈를 감소하기 위해 적절한 커널을 선택하여 CT 검사를 하여야 한다.

  • PDF

반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험 (Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols)

  • 하성민;정성희;장혁재;박은아;심학준
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.28-35
    • /
    • 2015
  • 본 논문에서는 반복적 구성 기법과 관전류 노출자동조절 기법이 영상의 화질과 방사선량에 미치는 영향을 관상동맥 전산화단층촬영 혈관조영 영상(coronary computed tomography angiography, CCTA)을 대상으로 팬텀 실험에 기반하여 평가하고자 한다. 이를 위하여 미국 의학물리학회(American Association of Physics in Medicine) 표준의 성능 평가 팬텀을 320 다중검출열 CT로써 촬영하였다. 80 kVp, 100 kVp, 120 kVp의 관전압에 있어서, 관전류 노출자동조절 기법은 저선량 목표 표준편차(SD=44)와 고선량(목표 표준편차=33)의 두 가지 설정으로써 촬영하였다. 재구성 변수로서는 필터보정 역투영(FBP)와 반복적 재구성 방법을 설정하여, 전부 12개의 재구성 영상을 획득하였다(12=3 (80, 100, 120 kVp)${\times}2$ (저선량(목표SD=44), 고선량(목표SD=33))${\times}2$ (필터보정역투영, 반복적 재구성). 영상의 화질은 잡음의 세기(표준편차), 변조전달함수, 대조대잡음비(CNR)에 의하여 평가하였으며, 관전압과 관전류 노출자동조절 기법에서의 목표 선량과 대소 및 재구성 기법의 선택이 화질과 방사선량에 미치는 영향을 관찰하였다. 반복적 재구성 기법은 필터보정역투영 기법보다 영상 잡음을 대폭 감소시켰으며 이는 저선량의 경우 더욱 뚜렷하였다. 즉, 잡음의 세기는 관전류 노출자동조절의 설정이 고선량 (목표SD=33)과 저선량(목표SD=44)인 경우, 각각 평균 38%와 평균 46% 감소하였다. 반복적 재구성 기법에 의하여, 변조전달 함수에 의한 공간적 해상도의 평가에 있어서 미약한 감소를 보였으나, 이로써 잡음 저감과 대조대잡음비(CNR)에 있어서의 현저한 개선을 상쇄할 정도의 영향에는 미치지 못 하였다. 결과적으로, 관상동맥 전산화단층촬영 혈관조영 영상의 획득에서 있어서, 반복적 재구성 기법과 관전류 노출자동조정 기법을 동시에 사용하는 것은 영상의 화질을 개선하면서 공간적 해상도의 저하 등 그 부작용은 최소화함으로써, 합리적으로 획득 가능한 한 최소한의 선량 (ALARA)의 원칙에 충실한 실제 임상적 효과를 의미한다고 기대할 수 있다.