• Title/Summary/Keyword: multi-detector computed tomography

Search Result 85, Processing Time 0.039 seconds

Evaluation of Surface Radiation Dose Reduction and Radiograph Artifact Images in Computed Tomography on the Radiation Convergence Shield by Using Sea-Shells (전산화단층영상장비에서 패각을 이용한 방사선 융합차폐체의 표면 방사선량 감소율과 방사선 인공물 영상 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2017
  • The purpose of this present study was to evaluate the surface radiation dose reduction and radiograph artifact images in computed tomography (CT) for the manufactured radiation shields by using sea-shells. The radiation convergence shields were made from silicons, sea-shells, barium powders, producted circle types of diameter 50 mm, thickness 3.5 mm for 5 kinds (only silicon shield, only barium shield, mixed sea-shells with silicon shield, mixed barium with silicon shield, mixed sea-shells with barium and silicon shield). Radiation generation and acquisition were used 4-channel multi-detector CT. The results of this study showed that mixed sea-shells with silicon shields could reduce the surface dose of 5.3% without radiograph artifact images. In the future, we will expect the radiation convergence shield as environmentally friendly materials by using the recycling of sea-shells with the advantages of silicon which can make various shapes.

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.

  • PDF

Comparison of dental radiography and computed tomography: measurement of dentoalveolar structures in healthy, small-sized dogs and cats

  • Lee, Seunghee;Lee, Kichang;Kim, Hyeona;An, Jeongsu;Han, Junho;Lee, Taekwon;Jeong, Hogyun;Cho, Youngkwon
    • Journal of Veterinary Science
    • /
    • v.21 no.5
    • /
    • pp.75.1-75.8
    • /
    • 2020
  • Background: Dental diseases are common in dogs and cats, and accurate measurements of dentoalveolar structure are important for planning of treatment. The information that the comparison computed tomography (CT) with dental radiography (DTR) is not yet reported in veterinary medicine. Objectives: The purpose of this study was to compare the DTR with CT of dentoalveolar structures in healthy dogs and cats, and to evaluate the CT images of 2 different slice thicknesses (0.5 and 1.0 mm). Methods: We included 6 dogs (2 Maltese and 1 Spitz, Beagle, Pomeranian, mixed, 1 to 8 years, 4 castrated males, and 2 spayed female) and 6 cats (6 domestic short hair, 8 months to 3 years, 4 castrated male, and 2 spayed female) in this study. We measured the pulp cavity to tooth width ratio (P/T ratio) and periodontal space of maxillary and mandibular canine teeth, maxillary fourth premolar, mandibular first molar, maxillary third premolar and mandibular fourth premolar. Results: P/T ratio and periodontal space in the overall dentition of both dogs and cats were smaller in DTR compared to CT. In addition, CT images at 1.0 mm slice thickness was generally measured to be greater than the images at 0.5 mm slice thickness. Conclusions: The results indicate that CT with thin slice thickness provides more accurate information on the dentoalveolar structures. Additional DTR, therefore, may not be required for evaluating dental structure in small-sized dogs and cats.

Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning (3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가)

  • Chung, Gi-Chung;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

The Effects of a Vasodilator on Transluminal Attenuation Gradient at Coronary Computed Tomography Angiography

  • Moon Sung Kim;Eun-Ju Kang;Hyun Jin Kim;Moo Hyun Kim;Ki-Nam Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1285-1293
    • /
    • 2020
  • Objective: To evaluate the effects of vasodilators on contrast enhancement and transluminal attenuation gradient (TAG) of coronary arteries at coronary computed tomography angiography (CCTA). Materials and Methods: We retrospectively reviewed CCTA scans of patients who underwent double-acquisition CCTA; CCTA without a vasodilator, and CCTA during a intravenous (IV) infusion of nitrate. Among them, we enrolled 19 patients who had no significant atherosclerotic lesions or coronary spasms. In the control group, 28 patients were enrolled who showed normal coronary arteries on CCTA, which was acquired by a conventional method (sublingual vasodilator). We measured the TAG and Hounsfield units for each of the three major epicardial coronary arteries (reported as 'ProxHU') and then compared the results between the nitrate administration methods (CT without vasodilator [CTpre], CT with IV vasodilator [CTiv], and CT with sublingual vasodilator [CTsub]). Results: The mean TAG showed a significant difference between the coronary arteries (right coronary artery [RCA] > left anterior descending artery [LAD] > left circumflex artery [LCX], p < 0.05), while there was no difference in ProxHU of each coronary artery in all three types of nitrate administration methods (p > 0.05). The TAG of CTpre group showed steeper slope than those of vasodilator groups (CTiv and CTsub) on LAD and LCX ([LAD: CTpre = -22.1 ± 6.66, CTiv = -16.76 ± 5.78, and CTsub = -16.47 ± 5.78, p = 0.005], [LCX: CTpre = -31.26 ± 17.43, CTiv = -23.74 ± 14.06, and CTsub = -20.94 ± 12.15, p = 0.051]), while that of RCA showed no significant differences (p = 0.600). When comparing proxHU, CTiv showed higher proxHU than that of CTpre or CTsub, especially on LCX (CTpre = 426.7 ± 68.3, CTiv = 467.9 ± 84.9, and CTsub = 404.9 ± 63.3, p = 0.013). ProxHU showed a negative correlation with TAG on all three of methods (r = -0.280, p < 0.001). Conclusion: TAG in CCTA was significantly affected by vasodilator administration. Both TAG and ProxHU of coronary arteries tend to increase with vasodilator administration on CCTA.

Imaging Diagnosis using Computed Tomography in Three Dogs with Giant Bullous Emphysema (컴퓨터단층촬영을 이용한 거대 낭포성 폐기종의 진단 3례)

  • Choi, Soo-Young;O, I-Se;Kang, Jong-Il;Lee, In;Song, Yu-Mi;Jeong, Woo-Chang;Lee, Ki-Ja;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.241-245
    • /
    • 2014
  • A miniature pinscher and two Maltese dogs were present with dyspnea, and radiography and computed tomography (CT) were performed. All dogs were diagnosed with giant bullous emphysema of the massive, hyperexpanded, and hypoattenuating bulla causing contralateral mediastinal shift. Giant bullous emphysema, the rarest form of bullous lung disease, is defined as a bulla that fills more than 30% of the hemithorax, and multi-detector CT scanning could provide the useful information to confirm a diagnosis of giant bullous emphysema in older dogs. The radiographic and computed tomographic features for giant bullous emphysema were described.

A Study on the Skull Injury Using MDCT image and ADINA F.E.M. Program (MDCT 영상과 ADINA 유한요소해석 프로그램을 활용한 두개골 손상 평가에 관한 연구)

  • Kim, Eui Soo;Kim, Jong Hyuk;Yang, Kyung Moo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • In this paper, the finite element analysis using ADINA has performed to investigate an accident that a man's head was damaged by the falling object. The simulation condition has defined by the point of forensic medicine view and the CCTV image analysis. From the CCTV image analysis, we expected that the sphere diameter of object is 15cm and object color is white. Assuming the falling mass is the ice mass, the results of the ADINA simulation show that a man's head can be broken by the falling ice mass.

Hybrid Approach for Treatment of Multiple Traumatic Injuries of the Heart, Aorta, and Abdominal Organs

  • Kim, Seon Hee;Song, Seunghwan;Cho, Ho Seong;Park, Chan Yong
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.372-375
    • /
    • 2019
  • A 55-year-old man was admitted to the trauma center after a car accident. Cardiac tamponade, traumatic aortic injury, and hemoperitoneum were diagnosed by ultrasonography. The trauma surgeon, cardiac surgeon, and interventional radiologist discussed the prioritization of interventions. Multi-detector computed tomography was carried out first to determine the severity and extent of the injuries, followed by exploratory sternotomy to repair a left auricle rupture. A damage control laparotomy was then performed to control mesenteric bleeding. Lastly, a descending thoracic aorta injury was treated by endovascular stenting. These procedures were performed in the hybrid-angio room. The patient was discharged on postoperative day 135, without complications.

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.