• 제목/요약/키워드: moving imaging

검색결과 184건 처리시간 0.034초

SMC Full PACS로의 전환 및 System 구축

  • 김삼수
    • 대한디지털의료영상학회논문지
    • /
    • 제3권1호
    • /
    • pp.20-23
    • /
    • 1997
  • The purpose of this paper is to describe the transition of a 1,100 beds teritary hospital from 50% softcopy operation to full PACS operation. For the past 2 years, radiologists and clinicians have been using PACS to provide softcopy services to the outpatient clinics and inpatient wards of orthopedics surgery, neurosurgery and neurology as well as emergency room, surgical intensive care unit, medical intensive unit, pediatrics intensive care unit and neonatal intensive care unit. The examinations requested by these departments account for about 50% of hospital's radiological exams. In September 1996, we began the second phase of PACS implementation and installed additional workstations (102) in the remaining wards and clinics, interfaced to PACS additional imaging modalites, and increased the capacity of both the image server (256 Gbytes) and optical juke boxes (3 Tbytes). As of January 1997, we are in the final phase of moving away from conventional film system to full PACS operation.

  • PDF

복부 핵자기공명 영상에서 영상번짐의 교정을 위한 최적 호흡 정렬법 (Optimal Respiratory Ordering Scheme (OROS) for Correcting Blurring Artifacts in Abdominal Magnetic Resonance Imaging)

  • 정관진;안우연;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.15-18
    • /
    • 1990
  • In abdominal NMR imaging the respiratory ordering techniques have been successfully used to remove the ghosting artifacts arising from the respiratory motion. In the existing respiratory ordering schemes, however, it is generally accepted that blurring of the moving parts still remains as in the signal averaging technique. A new optimal respiratory ordering scheme which can correct the blurring as well as the ghosting artifacts is theoretically derived through the analysis of the phase encoding directional motion effects in Fourier imaging. The performance of the optimal respiratory ordering scheme is experimentally confirmed together with a suboptimal ordering scheme which is suggested as a compromise for the practicality.

  • PDF

Motion analysis using the normalization of motion vectors on MPEG compressed domain

  • Kim, N.W.;Kim, T.K.;Choi, J.S.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1408-1411
    • /
    • 2002
  • In this paper, we propose a method that converts motion vectors on MPEG coded domain as a uniform set, independent of the frame type and the direction of prediction, and directly utilizes these normalized motion vectors for understanding video contents. This frame-type-independent motion vectors are utilized as feature information for image retrieval or moving object tracking on compressed domain. By simulation, we evaluate the effectiveness of the proposed method and compare its performance to the conventional method.

  • PDF

동영상 화질 개선을 위한 Constant Luminance 적용에 관한 연구 (A Study on Applying Constant Luminance for Quality Enhancement of Moving Images)

  • 김진서;강병호;조맹섭
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2002년도 추계학술발표논문집 (상)
    • /
    • pp.735-738
    • /
    • 2002
  • 휘도 신호만을 이용한 흑백 TV 에서부터 오늘날의 디지털 HDTV 에 이르기까지의 TV 시스템에서 사용되어 온 영상 신호의 생성, 전송 및 재생 방법은 HDTV, 디지털 시네마 등 영상 시스템의 획기적인 발전과 더불어, 보다 고선명, 고화질을 요구하게 되었다. 본 논문에서는 기존의 TV 시스템에서의 영상재생 결과와, constant luminance방법에 의한 영상 재생 결과를 관찰자 평가 실험을 통해 비교 분석한 데이터를 제시한다.

  • PDF

The Mobile Terminal System Implementation of Medical Imaging based on Motion-JPEG

  • Kim, Jae-Joon;Jung, Dae-Wha
    • 한국멀티미디어학회논문지
    • /
    • 제12권12호
    • /
    • pp.1701-1709
    • /
    • 2009
  • The mobile terminal system plays a key role in medical industries which require in fast and accurate diagnosis from heterogeneous acquisition equipment. The demand for PACS (picture archiving and communication systems) has continued to increase in major hospitals and private clinics. Patient care depends on how fast the medical imaging system provides images and how accurately the images are interpreted by physicians. In this paper, we propose an efficient method to decipher the hundreds of images required by physicians to accurately diagnose patients. By exploring Motion- JPEG (M-JPEG), this paper has demonstrates the possibilities for efficient management of medical images with a newly designed image file format and improvement in imaging diagnoses through the replaying of moving pictures of a patient in a mobile environment.

  • PDF

Three Dimensional Volume Reconstruction of Polyhedral Objects Using X-ray Stereo Images

  • Roh, Young-Jun;Kim, Byung-Man;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.28.2-28
    • /
    • 2001
  • Three dimensional shape measurement techniques are widely needed in industries for product quality monitoring and control. X-ray imaging method is a promising technology to achieve three-dimensional Information, both the surface and inner structure of an object, since it can overcome the limitations of conventional visual or optical methods such as an occlusion problem or surface reflection properties. In this paper, we propose three dimensional volume reconstruction method based on x-ray stereo imaging technology. Here, the stereo images of an object from two different views are taken by changing the object pose rather than moving imaging plane as in conventional stereo vision method. We propose a series of image processing techniques to extract the features efficiently from x-ray images, where the occluded features in case of normal camera vision could be found ...

  • PDF

고기동 표적 추적 성능 개선을 위한 연구 (Performance Improvement for Tracking Small Targets)

  • 정윤식;김경수;송택렬
    • 제어로봇시스템학회논문지
    • /
    • 제16권11호
    • /
    • pp.1044-1052
    • /
    • 2010
  • In this paper, a new realtime algorithm called the RTPBTD-HPDAF (Recursive Temporal Profile Base Target Detection with Highest Probability Data Association Filter) is presented for tracking fast moving small targets with IIR (Imaging Infrared) sensor systems. Spatial filter algorithms are mainly used for target in IIR sensor system detection and tracking however they often generate high density clutter due to various shapes of cloud. The TPBTD (Temporal Profile Base Target Detection) algorithm based on the analysis of temporal behavior of individual pixels is known to have good performance for detection and tracking of fast moving target with suppressing clutter. However it is not suitable to detect stationary and abruptly maneuvering targets. Moreover its computational load may not be negligible. The PTPBTD-HPDAF algorithm proposed in this paper for real-time target detection and tracking is shown to be computationally cheap while it has benefit of tracking targets with abrupt maneuvers. The performance of the proposed RTPBTD-HPDAF algorithm is tested and compared with the spatial filter with HPDAF algorithm for run-time and track initiation at real IIR video.

PFA와 CDT 알고리즘을 이용한 2차원 ISAR 영상 생성 (2D ISAR Imaging using PFA and CDT Algorithms)

  • 유지희
    • 한국전자파학회논문지
    • /
    • 제15권9호
    • /
    • pp.906-913
    • /
    • 2004
  • 레이다 데이터로부터 ISAR(Inverse Synthetic Aperture Radar) 영상을 생성 할 때 가장 보편적으로 사용되는 것이 FFT 알고리즘이다. FFT 알고리즘을 넓은 방위각 데이터에 적용할 때는 MTRC(Moving Through Resolution Cell) 현상으로 영상의 번짐이 발생하는데 이를 보정하기 위하여 polar formatting 기법을 적용한다. 그러나 polar formatting도 적용할 수 있는 각도의 한계가 존재하며 만약 지나치게 넓을 경우 polar formatting을 적용하여도 원하는 영상을 얻을 수 없게 된다. 이 논문에서는 ISAR 영상 생성시 내삽법을 사용하는 polar formatting기법과 polar formatting의 단점인 내삽법을 사용하지 않는 CDT(Coherent Doppler Tomography) 기법을 비교하여 각각의 장단점을 분석하였다.

자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究) (A Study on Locational Control of Motion Ghost in Magnetic Imaging System)

  • 이후민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

MIMO 레이다 환경에서 Polar Format Processing 기반 이동표적 이미징 (Polar-Format-Processing-Based Moving Target Imaging in MIMO Radar Environment)

  • 최상현;양훈기
    • 한국전자파학회논문지
    • /
    • 제30권2호
    • /
    • pp.124-131
    • /
    • 2019
  • 본 논문은 여러 송수신 레이다들이 지상에 고정된 MIMO(multiple input multiple output) 레이다 환경에서 이동표적을 이미징할 수 있는 알고리즘을 제시한다. 제시된 알고리즘은 평면파 근사를 사용한 polar format processing에 기반한 것으로 수신 레이다 간 이격이 큰 경우에도 복수의 송신 레이다를 사용해서 앨리어싱(aliasing) 현상이 배제된 이동표적 이미지를 얻을 수 있음을 보인다. 앨리어싱 현상을 줄이면서 해상도를 높일 수 있는 송신 레이다 배치에 대한 조건을 제시하며, 또한 각 송신 레이다에 의한 표적 산란 신호를 수신 레이다에서 분리시킬 수 있는 방법을 제시한다. 마지막으로 시뮬레이션을 통해서 제시된 MIMO 레이다 시스템의 성능을 검증한다.