• 제목/요약/키워드: movement time

Search Result 3,689, Processing Time 0.037 seconds

A Study on the Abdominal Diagnostic Method of Kitao Shunpo about the Movement Qi between kidneys (북미춘포(北尾春圃)의 신간동기(腎間動氣) 복진법(腹診法)에 대한 고찰(考察))

  • Kim, Hye-il;Baik, You-sang
    • Journal of Korean Medical classics
    • /
    • v.29 no.3
    • /
    • pp.113-132
    • /
    • 2016
  • Objectives : In this study, the Abdominal Diagnostic Method of Kitao Shunpo(北尾春圃) about Movement Qi between kidneys in Sanghauidam(桑韓醫談) and Jeonggisinron(精氣神論) are investigated for the purpose of understanding the definite technique of the method and the position in the context of abdominal diagnosis in Japan. Methods : The materials related to the abdominal diagnosis to Movement Qi between kidneys were selected from Sanghauidam and Jeonggisinron written by Kitao Shunpo, and analyzed to know the characteristics of the method. Results : Kitao Shunpo suggested the theoretical background of the Abdominal Diagnostic Method that Original Qi(元氣) is made from Original Essence(元精) when a person is born, and mentality(神) and body essence(精), qi(氣) and blood(血) are formed from those. Movement Qi between kidneys(腎間動氣), that is to say innate Original Qi can be diagnosed in abdominal region by the method in Japanese Medicine. Kitao Shunpo decided deficiency and excess of Original Qi and prognosis in clinical treatment by the method, and suggested the standard pulse condition of the Movement Qi between kidneys. Conclusions : After the theory about Movement Qi between kidneys appeared in Nanjing(難經), many doctors have not made attention to diagnose that for a long time, until Kitao Shunpo with other Japanese doctors established the theoretical background of the Abdominal Diagnostic Method, and applied the theory to clinical treatment.

Usefulness of Electrophysiological Tests in Movement Disorders (이상운동 질환에서의 신경생리적 검사법의 유용성)

  • Seo, Man-Wook;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.126-146
    • /
    • 1999
  • In clinical neurology various different electrophysiological tests are widely used to demonstrate the unsuspected malfunctioning in the nervous system and to monitor over time the clinical status of patients. In addition clinical neurologists and neurosurgeons take advantage of the intraoperative monitorings to increase the quality of neurosurgical operations in the posterior fossa, in the spinal cord, or in visual pathways. In the field of movement disorders, elecrophysiolgical tests provide neurologists with making accurate differential diagnoses with useful therapeutic stratergies as well as with investigating the pathophysiological machanisms. By using the electromyographic tests it could be possible for us to evaluate the types of blephalospasm, the extent of hemifacial spasm, the level of myoclonus, and the prime muscles of torticollis etc. Sometimes the myographic guidance may be critical for choosing the exact injecting site of botulinum toxin. These several decades various electroencephalographic and evoked potential tests has been utilized in the electrophysiological laboratories to understand the basic pathophysiology of myoclonus, spasticity and other central motor dysfunctions. It could be one of the breakthroughs in the area of behavorial neurology that the brain function can be mapped by the spontaneous or evoked electrical activities of nervous system since the movement related potentials (MRPs) had been studies for several decades. Various reflex tests such as masseter reflex, blink reflex, click evoked vestibulocollic reflex, facial reflex, stretch reflex, flexor reflex, H-reflex, H-reflex recovery curve, vestibular inhibition of H-reflex, reciprocal inhibition, recurrent or Renshaw reflex, Ib inhibition, cutaneous reflex have been also used to understand normal or abnormal physiology in movement disorders. Polysomnography, posturography and gait studies are also applied in clinical neurology in association with with movement disorders which are useful in deciding the treatment regimen.

  • PDF

The Effects of Trunk Movement and Ground Reaction Force during Sit to Stand Using Visual Feedback (시각 되먹임을 이용한 앉은 자세에서 일어서기 시 몸통의 동작과 지면 반발력에 미치는 영향)

  • Yeong-Geon Koh;Tae-Young Oh;Jae-Ho Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.207-219
    • /
    • 2023
  • Purpose : This study was conducted to investigate the changes in trunk movement and ground reaction during sit to stand motion using visual feedback. Methods : Fifteen adults (average age: 23.53±1.77 years) participated in this study. An infrared reflective marker was attached to the body each participant for motion analysis, and the participants performed sit to stand motion while wearing a hat attached with a laser pointer, which provided visual feedback. First, the sit to stand action was repeated thrice without obtaining any visual feedback, followed by a three minute break. Next, the laser pointers attached to hats were irradiated on a whiteboard, located at a distance of 5 m in front of the chairs, on which the participants sat; a baseline was set, and the participants performed stand up movements three times under this condition. A visual feedback was provided to the participants to prevent the laser pointers from crossing the set baseline. During each stand-up movement, the position of the reflective marker attached to the subject's body was recorded in real time using an infrared camera for motion analysis. The trunk movement and ground reaction force were extracted through recorded data and analyzed according to the presence or absence of visual feedback. Results : The results indicated that in the presence of a visual feedback during the sit-to-stand movements, the range of motion of the trunk and hip joints decreased, whereas that of the knee and ankle joints increased in the sagittal plane. The rotation angle of the trunk in the horizontal plane decreased. The left and right movement speed of the center of pressure increased, the pressing force decreased, and the forward and backward movement speed of the trunk decreased. Conclusion : The results suggest that the efficiency and stability of the stand up movement of a body increase when a visual feedback is provided.

Analysis of fluctuations in ex-core neutron detector signal in Krško NPP during an earthquake

  • Tanja Goricanec;Andrej Kavcic;Marjan Kromar;Luka Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.575-600
    • /
    • 2024
  • During an earthquake on December 29th 2020, the Krško NPP automatically shutdown due to the trigger of the negative neutron flux rate signal on the power range nuclear instrumentation. From the time course of the detector signal, it can be concluded that the fluctuation in the detector signal may have been caused by the mechanical movement of the ex-core neutron detectors or the pressure vessel components rather than the actual change in reactor power. The objective of the analysis was to evaluate the sensitivity of the neutron flux at the ex-core detector position, if the detector is moved in the radial or axial direction. In addition, the effect of the core barrel movement and core inside the baffle movement in the radial direction were analysed. The analysis is complemented by the calculation of the thermal and total neutron flux gradient in radial, axial and azimuthal directions. The Monte Carlo particle transport code MCNP was used to study the changes in the response of the ex-core detector for the above-mentioned scenarios. Power and intermediate-range detectors were analysed separately, because they are designed differently, positioned at different locations, and have different response characteristics. It was found that the movement of the power range ex-core detector has a negligible effect on the value of the thermal neutron flux in the active part of the detector. However, the radial movement of the intermediate-range detector by 5 cm results in 7%-8% change in the thermal neutron flux in the active part of the intermediate-range detector. The analysis continued with an evaluation of the effects of moving the entire core barrel on the ex-core detector response. It was estimated that the 2 mm core barrel radial oscillation results in ~4% deviation in the power and intermediate-range detector signal. The movement of the reactor core inside baffle can contribute ~6% deviation in the ex-core neutron detector signal. The analysis showed that the mechanical movement of ex-core neutron detectors cannot explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake.

Development of Videooculograph for Vestibular Function Test (전정 기능 평가를 위한 영상 안구 운동 측정 시스템의 개발)

  • 김수찬;남기창;이원선;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.189-198
    • /
    • 2003
  • Videooculography (VOG) is one of the eye-movement measurement methods used for objective evaluation of vestibule -ocular reflex. A key feature of VOG is to estimate accurately the center of pupil and ocular torsion with being less influenced by the upper eyelid droop, eyelashes, corneal reflection, and eye blinks. Especially, it Is important to find the accurate center of the pupil in 3-D VOG because the inaccurate pupil center causes significant errors on measuring torsional eye movement. A new algorithm was proposed to find the center of pupil which is a little influenced by factors mentioned above. In this study, real time three-dimensional VOG which can measure horizontal, vortical, torsional eye movements, and the diameter of pupil was implemented using the proposed method.

A Case Study on Learning of Fundamental Idea of Calculus in Constant Acceleration Movement (등가속도 운동에서 미적분의 기본 아이디어 학습 과정에 관한 사례연구)

  • Shin Eun-Ju
    • Journal of Educational Research in Mathematics
    • /
    • v.16 no.1
    • /
    • pp.59-78
    • /
    • 2006
  • As a theoretical background for this research, the literatures which focus on the rationale of teaching and learning of connecting with mathematics and science in calculus were investigated. And teaching and learning material of connecting with mathematics and science in calculus was developed. And then, based on the case study using this material, the research questions were analyzed in depth. Students could understand mean-velocity, instant-velocity, and acceleration in the experimenting process of constant acceleration movement. Also Students could understand fundamental ideas that instant-velocity means slope of the tangent line at one point on the time-displacement graph and rate of distance change means rate of area change under a time-velocity graph.

  • PDF

Development of a Human Motion Analyzer (인체 동작 분석기의 개발)

  • 김민기;김성호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.217-222
    • /
    • 1995
  • We propose some applications of image processing techniques to extract quantitative measurements by using a camera system developed in Korea university and Catholic Medical School. From now on the system will be called as KCMOTION. The purpose of this study is to provide basic kinematic and kinetic data for the analysis of human movements and to find the clinical usefulness and reliability of the proposed motion analysis system. Two tests, sit-to-stand (STS) movements and pendulum test, are conducted by the system. The aims of the tests are to identify variability and reliability of KCMOTION to give some quantitative comparisons to the other systems. The result of STS movement are compared to the LOCUS IIID motion analyzer by the ratio of maximum flexion movement per body weight to the actual maximum flexion extension torque per body weight. That result in 29 % and 33 % for hip and knee joint, respectively in KCMOTION and 27 % and 30 % in LOCUS IIID System. The results of the pendulum movements are compared to that of using Cybex and Electrogoniometer with relaxation index, amplitude ratio, swing number and swing time. The results of relaxation index and amplitude ratio of the KCMOTION are between those of the Cybex and Electrogoniometer. We also observed that the KCMOTION detect more natural movement, from the results of swing number and time.

  • PDF

Partially Asynchronous Task Planning for Dual Arm Manipulators (양팔 로봇을 위한 부분적 비동기 작업 계획)

  • Chung, Seong Youb;Hwang, Myun Joong
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • In the agricultural field, interests in research using robots for fruit harvesting are continuously increasing. Dual arm manipulators are promising because of its abilities like task-distribution and role-sharing. To operate it efficiently, the task sequence must be planned adequately. In our previous study, a collision-free path planning method based on a genetic algorithm is proposed for dual arm manipulators doing tasks cooperatively. However, in order to simplify the complicated collision-check problem, the movement between tasks of two robots should be synchronized, and thus there is a problem that the robots must wait and resume their movement. In this paper, we propose a heuristic algorithm that can reduce the total time of the optimal solution obtained by using the previously proposed genetic algorithm. It iteratively desynchronizes the task sequence of two robots and reduces the waiting time. For evaluation, the proposed algorithm is applied to the same work as the previous study. As a result, we can obtain a faster solution having 22.57 s than that of the previous study having 24.081 s. It will be further studied to apply the proposed algorithm to the fruit harvesting.

Analytical and Experimental Studies on the design of Electromagnetic Shock Absorber (전자기식 충격흡수구조의 설계를 위한 동특성 해석 및 실험)

  • Yi, Mi-Seon;Bae, Jae-Sung;Hwang, Jae-Hyuk;Im, Jae-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • A shock absorber with magnetic effects is suggested for a lunar space-ship expected to launch in 2025. The device consists of a copper steel combined tube, two magnets, and a piston. The piston is designed to move a magnet through the tube when it is pushed by an external impact. While the magnet is moving in the tube, it generates the eddy current force with the copper part of the tube and it also makes the large friction force with the steel part of the tube. Beside, it gets resistive forces against its movement such as the magnetic force with a steel-ring at the first time of the movement and the repulsive force with a same pole opposed magnet at the end time of the movement. In this thesis, results of analyses and experiments of each force are represented and the expected performance of the electromagnetic shock absorber is drawn from the results.

A Numerical Study on Smoke Movement in Longitudinal Ventilation Tunnel Fires Using a Zone Model (존 모델을 이용한 종류식 배연 터널 화재시 연기 거동에 대한 수치해석적 연구)

  • Kim, Hyun-Jeong;Roh, Jae-Seong;Kim, Dong-Hyeon;Jang, Yong-Jun;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1319-1324
    • /
    • 2007
  • Many researches have been performed to analyze the smoke movement in tunnel fires by using field model. Recently, FDS(Fire Dynamics Simulator) v.4, which is one of the field model and developed from NIST(National Institute of Standards and Technology), is widely used. In tunnel fires, FDS can show detail results in local point, but it has difficulties in boundary condition and taking long computing time as the number of grid increases. So, there is a need to use alternative method for tunnel fire simulation. A zone model is different kind of CFD method and solves ordinary differential equation based on conservation and auxiliary equations. It shows good macroscopic view in less computing time compared to field model. In this study, therefore, to confirm the applicability of CFAST in tunnel fire analysis, numerical simulations using CFAST are conducted to analyze smoke movement in longitudinal ventilation reduced-scale tunnel fires. Then the results are compared with experimental results. The differences of temperature and critical velocity between numerical results and experimental data are over $30^{\circ}C$ and 0.9m/s, respectively. These values are out of error range. It shows that CFAST 6.0 is hard to be used for tunnel fire simulation.

  • PDF