• Title/Summary/Keyword: movement evaluation

Search Result 1,094, Processing Time 0.031 seconds

Functional Design Process of Coveralls for the Improvement of Mobility (동작기능성 향상을 위한 작업복 연구)

  • 홍경희;박길순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.2
    • /
    • pp.311-322
    • /
    • 1996
  • To accomodate workers with efficient mobility, coveralls were redesigned, construted and evaluated. In this study, especially, image processing techniques were applied to the evaluation stage, to quantify thE ease of body movement. For the initial observation stage, car-center workers were interviewed and their movements were videotaped. By analyzing the videotape, the area of stress and strains on the work clothes were marked on the figure chert and considered for the pattern making. 4DM cut pattern were applied to the upper part of the work clothes and other alternations were made throughout the problem area. Honey comb slashes were made on the problem area of the original and newly designed coveralls. Open areas of honey comb slashes due to body movement between the original and newly designed coveralls were analyzed by image processing techniques. Other objective and subjective evaluation of newly designed coveralls was compared with the original one. Overall evaluation of functionally designed coveralls was appered to be positive and the image processing techiques were useful methology to quantify the amount of stress in this study.

  • PDF

4-Dimensional dose evaluation using deformable image registration in respiratory gated radiotherapy for lung cancer (폐암의 호흡동조방사선치료 시 변형영상정합을 이용한 4차원 선량평가)

  • Um, Ki Cheon;Yoo, Soon Mi;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.83-95
    • /
    • 2018
  • Purpose : After planning the Respiratory Gated Radiotherapy for Lung cancer, the movement and volume change of sparing normal structures nearby target are not often considered during dose evaluation. This study carried out 4-D dose evaluation which reflects the movement of normal structures at certain phase of Respiratory Gated Radiotherapy, by using Deformable Image Registration that is well used for Adaptive Radiotherapy. Moreover, the study discussed the need of analysis and established some recommendations, regarding the normal structures's movement and volume change due to Patient's breathing pattern during evaluation of treatment plans. Materials and methods : The subjects were taken from 10 lung cancer patients who received Respiratory Gated Radiotherapy. Using Eclipse(Ver 13.6 Varian, USA), the structures seen in the top phase of CT image was equally set via Propagation or Segmentation Wizard menu, and the structure's movement and volume were analyzed by Center-to Center method. Also, image from each phase and the dose distribution were deformed into top phase CT image, for 4-dimensional dose evaluation, via VELOCITY Program. Also, Using $QUASAR^{TM}$ Phantom(Modus Medical Devices) and $GAFCHROMIC^{TM}$ EBT3 Film(Ashland, USA), verification carried out 4-D dose distribution for 4-D gamma pass rate. Result : The movement of the Inspiration and expiration phase was the most significant in axial direction of right lung, as $0.989{\pm}0.34cm$, and was the least significant in lateral direction of spinal cord, as -0.001 cm. The volume of right lung showed the greatest rate of change as 33.5 %. The maximal and minimal difference in PTV Conformity Index and Homogeneity Index between 3-dimensional dose evaluation and 4-dimensional dose evaluation, was 0.076, 0.021 and 0.011, 0.0 respectfully. The difference of 0.0045~2.76 % was determined in normal structures, using 4-D dose evaluation. 4-D gamma pass rate of every patients passed reference of 95 % gamma pass rate. Conclusion : PTV Conformity Index was more significant in all patients using 4-D dose evaluation, but no significant difference was observed between two dose evaluations for Homogeneity Index. 4-D dose distribution was shown more homogeneous dose compared to 3D dose distribution, by considering the movement from breathing which helps to fill out the PTV margin area. There was difference of 0.004~2.76 % in 4D evaluation of normal structure, and there was significant difference between two evaluation methods in all normal structures, except spinal cord. This study shows that normal structures could be underestimated by 3-D dose evaluation. Therefore, 4-D dose evaluation with Deformable Image Registration will be considered when the dose change is expected in normal structures due to patient's breathing pattern. 4-D dose evaluation with Deformable Image Registration is considered to be a more realistic dose evaluation method by reflecting the movement of normal structures from patient's breathing pattern.

  • PDF

Evaluation of Body Movement during Sleep with a Thermopile, Wavelets and Neuro-fuzzy Reasoning

  • Yoon, Young-Ro;Shin, Jae-Woo;Lee, Hyun-Sook;Jose C.Principe
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.5-10
    • /
    • 2004
  • Body movement is one of the important factors in sleep analysis. In this study, a thermopile detector with four channels was implemented as a non-contacting detector of body movement in sleep. Using a thermopile mathematical model and several frames of thermal images, the possibility of detecting body movement was evaluated. Instant body movement signals were evaluated for the upper, lower, and entire body using the Haar wavelet. This decomposition shows the points in time when the upper-body or lower-body movement occurred and the level of body movement. Additionally, partial body movement was decomposed in head-only, whole body, and leg-only movement using the ANFIS algorithm. Finally, three subject's data were evaluated for 60 minutes, and the detection rates of instant and partial body movement, on average, were 96.3% and 89.2%, respectively.

A Critical Review on the Government-driven Language Culture Improvement Projects: Focusing on the Pan-national Language Culture Improvement Movement 'Annyeong! Urimal(Hello! Our Language)' (정부 주도 언어문화개선 사업에 대한 비판적 고찰 -범국민 언어문화개선 운동 '안녕! 우리말'을 중심으로-)

  • CHO, TAE-RIN
    • Korean Linguistics
    • /
    • v.79
    • /
    • pp.145-169
    • /
    • 2018
  • The purpose of this paper is to review critically the validity and relevance of the pan-national language culture improvement movement, Annyeong! Urimal(Hello! Our Language) implemented for the last three years as part of the government-driven projects, and to seek for improvement direction or fundamental reorientation of this movement. In order to accomplish this purpose, this paper firstly points out abstract and conventional aspects of the diagnosis for background and the purpose of projects, and suggests that this movement focuses on verbal abuse rather than language destruction and pays attention to positive aspects of newly rising language use. Then, with reference to main agent, this paper argues that the government must lead actively formation of voluntary nongovernmental agent with indirect financial and institutional support. Thirdly, it is suggested that public language should be the top priority target sphere and the language used by the leaders of society and the older generation should be also included in the target spheres of this movement. Finally, this paper indicates that enlightenment/public relation projects end often in one time events, imposing unilaterally the normative contents, and also emphasizes the importance of survey/research projects and deliberation/evaluation projects.

Evaluation of the Identification method of Joint Mechanical Properties Using Isokinetic Movement (등속운동을 이용한 관절계 역학적 특성치 정량화 방법의 유용성 평가)

  • 이창한;허지운;김철승;엄광문
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1190-1193
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque, so that the estimation of damping property from the isokinetic movement is difficult.

  • PDF

유한 요소법을 이용한 중소하천 유역에서의 이동호우에 대한 유출특성 분석

  • Cho, Hyeon-Kyeong;Lee, Yeung-Hwa;Choi, Yun-Yeong
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.415-424
    • /
    • 1998
  • In the rainfalll-runoff relation, consideration of the spatial movement of storms is very unportant in designing a hydraulic structure or evaluating an environmental influence for land usage. Because of thins reason, this study has suggested the finite element model which consider the spatial movement of a storm and it was applied on a small river basin(Wi stream basin). In the application of the model, the basin was treated as a pivot point and the storms are simulated 10 movement in each directions. As a result, It shows that the storms moving from north to south have higher peak discharge and faster peak time than the storms moving in other directions. So these characteristics have to be considered In the designation of a hydraulic structure or evaluation of an environmental influence.

  • PDF

Clinical Evaluation of 3 patients with Paradoxical Vocal Cord Movement (역설적 성대운동을 보이는 3명의 환자에 대한 임상분석)

  • 최선명;임길채;한광우;남순열
    • Korean Journal of Bronchoesophagology
    • /
    • v.9 no.1
    • /
    • pp.83-86
    • /
    • 2003
  • Background and Objectives : Paradoxical vocal cord movement is a series of paroxysmal adduction of the anterior two-thirds of the vocal cords during respiration or during phonation. The choking, stridor, and wheezing in this condition occur primarily on inhalation, rather than on exhalation. The two pathognomonic diagnostic criterias that need to be assessed during an acute presentation are laryngoscopy with direct visualization of paradoxical adduction of the vocal cords and pulmonary function testing. Materials and Methods : A retrospective review of 3 patients who were referred to otolaryngologist from pulmonology department, and were confirmed by typical laryngoscopic findings with paradoxical adduction of the vocal cords was conducted. Results The patients were misdiagnosed as exercised-induced asthma, and unresponsive to corticosteroid and bronchodilators. Improvement was achieved only by diagnosis with paradoxial vocal cord movement. Biofeed back therapy, voice therapy, treatment for reflux laryngitis improved symptoms. Conclusion The etiology of paradoxical vocal cord movement is unknown. It may be functional or emotional. The functional factors that were proposed are neurologic deficit and gastroesophageal reflux. Management methods of this condition consist of psychological counselling, voice therapy, and antireflux medication.

  • PDF

The Evaluation of Performance of C-11 Radio Isotope Gas Target using Finite Element Method (FEM을 이용한 C-11 동위원소 기체표적의 성능평가)

  • Oh, Hwan-Sup;Hur, Min-Goo;Park, Sang-Pil;Jung, Hyo-Jin
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.3
    • /
    • pp.24-31
    • /
    • 2006
  • The energy degrader is the most fragile part of the security of a target, has been newly designed to improve the performance of the gas target. Also, the numerical analysis of the heat movement and mechanical movement during the operation of the target has been accomplished. The heat analysis and structure analysis which are using the cooling water flow and pressure in the energy degrader and the finite element analysis program, has been considered with the heat movement and mechanical movement according to the current capacity of proton beam which determines the production yield of the radioactive isotope. Also the possible use range has been determined and at the same time the most suitable running condition according to the current capacity of proton beam has been suggested.

Experimental Study of the Joint Movement Responsiveness Performance to the One-Component Silicon Sealants at Curing Phase (경화단계에서의 1성분형 실리콘 실란트의 거동대응성능에 관한 실험적 연구)

  • Son, Jong-Won;Ono, Tadashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.63-64
    • /
    • 2014
  • In this study, we has a purpose to estimate the joint movement responsiveness performance for the domestic products of one-component structural silicon sealants. For this purpose, we make a comparative study for the four domestic products focused on tensile properties after allowed the cyclic-movements for three days at initial step of curing phase. A joint movement range ±10% and the rate of compression and extension 3.2mm/h were assumed in those tests. As a result, the large space were induced inside the sealant by rupture, and then adhesion and cohesion failures were caused by stress concentration. The tensile properties were reduced by 15~60% in comparison with physical properties. In this case, the generating defect was caused and the service-life was decreased. Thus, further researches as relationship of test condition and products properties on this behavior would be studied.

  • PDF

A Study of the Single PPM Quality Innovation's Movement and Satisfaction in the Enterprise (싱글PPM 품질혁신 운동과 기업의 만족도에 관한 연구)

  • Kim, Tae-Sung;Koo, Il-Seob
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.11a
    • /
    • pp.145-152
    • /
    • 2008
  • Single PPM Quality Innovation Movement is originally developed quality program in Korea for supplier's quality level-up since 1995. The quality target is below the 10ppm(parts per million) in outgoing quality and delivered goods plus field claim. This Single PPM Quality Innovation Movement program was conducted to realize the anticipated results not only due to management result level's increasing, but also the company's confidence and competitiveness. This study attempted to find the mutual influences on the participation of the constituent members, satisfaction of the constituent members and results of the management from Single PPM Quality Innovation Movement. The reliance analysis for the measurement material on the questionnaire was verified by Cronbach's alpha coefficient. Participation of the constituent members, satisfaction of the constituent member and result of the management, the influences upon Single PPM improvement degree level were verified through the structural analysis by using SPSS statistic package. The influence evaluation among the groups was evaluated by the structure equation.

  • PDF