• 제목/요약/키워드: motor handpiece

검색결과 13건 처리시간 0.028초

Battery type 외과수술용 핸드피스 구동 드라이브 시스템 (Development of Battery Type Powered Handpiece Drive System for Surgical Operation)

  • 하정준;윤용호
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

Air-jet기능을 장착한 멀티형 복합유닛 핸드피스의 사용 만족도 조사 (A study on the usage satisfaction of multi-type handpieces with equipped air-jet function)

  • 김임선;최병환
    • 대한치과기공학회지
    • /
    • 제37권3호
    • /
    • pp.169-178
    • /
    • 2015
  • Purpose: This study was to investigate usage satisfaction of multi type handpiece with equipped air-jet function Methods: The subjects of this study through the survey was conducted for fifty-nine dental technicians in Daegu and Gyeongsangbukdo from the May 7 to 19, after the June 23 to July 4 2014. The survey was about the function and quality through user testing environment by cutting zirconia specimens using appliance for zirconia. The collected date was analyzed by the statistical program SPSS Win Ver 19.0 for the satisfaction of handpiece and control system. To test for significance on each item, p<0.05 had been decided a standard. General characteristics and relationship between the handpiece and control system was performed correlation analysis. Results: The results of this study is as follows. 35 dental technicians had 1~2 years career in zirconia part as the highest 59.3%, 95% of subjects expected that the prospects for the zirconia material have bright prospects. The satisfaction of multi type handpiece and control system design and function showed a significant difference. Subjects satisfied with the design and function of the multi type showed negative correlation with those of Standard. The satisfaction of multi type handpiece showed 3.37 points of air jet, 3.05 points of noise level, 2.69 points of water flow rate, and 1.98 points of cruise function. Sample differences in all parameters showed a statistically higher difference. Conclusion: High-speed cutting mechanism of multi-type is recommended working with zirconia materials and the multi-type unit combined handpiece motor, air-turbine and air-gun will be expected the increase of user due to the high satisfaction of air jet.

마이크로 모터 핸드피스를 위한 BLDC 전동기 제어시스템 개발 (A Development of the Control System of BLDC Motor for Micro Motor Handpiece)

  • 백원식;송현직;김민회;김동희;이헌욱;황돈하
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 2008
  • The permanent magnet BLDC motors are increasingly being used in high performance applications due to the high torque density and simplicity in their control. In this paper, the control system of the BLDC motor is developed which can be used for the micro motor handpiece, and position sensorless control is realized using back EMF measurement scheme, The validity and practical applications of the developed slotless BLDC motor and drive system are verified through the experimental results.

  • PDF

핸드피스용 BLDC 모터 속도 제어시스템의 설계 (Design of Brushless DC Motor Speed Control System for Handpieces)

  • 곽성우;양정민
    • 한국전자통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.597-604
    • /
    • 2016
  • 본 논문에서는 미용 목적의 핸드피스에 사용가능한 BLDC 모터의 속도 제어 시스템을 구현한다. 저비용 개발을 위해 모터 내부의 홀 센서 값을 속도 제어에 이용하였다. 모터 전원 회로와 드라이버 회로는 가정용 220V 전원을 입력으로 사용하도록 설계하였으며 별도의 다른 전원은 필요로 하지 않는다. 핸드피스 작업 시 발생하는 부하 변동에 따른 급속한 속도 증가를 방지하기 위해 별도의 과속 방지 제어기를 탑재하였다. 개발된 제어 시스템은 5,000~30,000 RPM 구간에서 운용 가능하다. 본 연구에서 개발된 핸드피스 모듈에서 부하 변동이 있음에도 불구하고 모터의 속도가 일정하게 유지됨을 실험으로 입증한다.

치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구 (Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality)

  • 손재환;한창우;최상일;김용중;최창진
    • 한국산업융합학회 논문집
    • /
    • 제9권3호
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF

두가지 피에조 엔진의 사용자 만족도 비교 (A comparative study on the user satisfaction between two different piezoelectric engines)

  • 임현미;이규복;이완선;최소영
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.269-277
    • /
    • 2017
  • 목적: 치과의사의 사용 만족도 비교를 통해 두 가지 피에조 엔진의 성능을 비교평가 하고자 한다. 연구 재료 및 방법: 본 연구에서는 두 가지의 피에조 엔진을 평가하였다:TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). 20명의 치과의사가 11개 평가항목에 답하였고, 평가결과는 Likert의 5점 척도를 적용하여 수치화하였다. 핸드피스 소음평가는 10초 동안 5회 측정하여 최고소음을 비교하였다. 핸드피스 발열평가는 세 부위에서 3분동안의 발열량을 측정하였다. 결과: 평가항목 중 '주수펌프 모터의 소음'에서 TRAUS XUS10이 PIEZOSURGERY touch보다 유의하게 만족도가 높았다. 반면, '기능key의 만족도'와 '핸드피스 발열정도'는 PIEZOSURGERY touch가 더 우수했다. 소음 최대값은 TRAUS XUS10이 56.6 dB, PIEZOSURGERY touch는 56.0 dB였다. 두 기기 모두 3분 작동 후 $41^{\circ}C$ 미만의 열을 발생시킴으로써 안전기준을 만족하였다. 결론: TRAUS XUS10는 '기능 key' 및 '핸드피스 발열정도'에서 약간의 개선을 한다면 그 외 대부분의 평가항목에서는 PIEZOSURGERY touch과 견줄만한 성능을 보인다.

왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교 (Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation)

  • 전영주;김진우;조경모;박세희;장훈상
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브 (Battery Type Surgical Handpiece Using Brushless DC Motor Drive)

  • 유재성;박종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.128-130
    • /
    • 2007
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진 수술 기법인 인공관절 대체 수술 시 뼈(Bone)절단, 다듬질 구멍 등, 초 섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF

배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브 (Battery Type Surgical Handpiece Using Brushless DC Motor Drive)

  • 박상훈;윤용호;이병국;원충연;전재홍;안일순
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.334-337
    • /
    • 2006
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진수술 기법인 인공관절대체수술 시 뼈(Bone) 절단, 다듬질, 구멍등 초섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF