• Title/Summary/Keyword: motor case

Search Result 1,425, Processing Time 0.027 seconds

Characteristics Analysis for Motor or Generator Operating of Induction Machine with Deep or Double Cage Rotor (심구 또는 이중 농형 회전자를 가진 유도기의 전동 또는 발전 운전시 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 2014
  • Both of induction generator and synchronous generator is available in the hydroelectric power plant. If the output of the power station is large, the synchronous generator is mainly used but when its output is low, the induction generator is often used. If the output capacity is small, there is a case in which induction motor is used as a generator. Torque at rated operation and start of the induction motor is different depending on the shape of the rotor. Small and medium-sized squirrel-cage induction motor is used primarily double cage rotor or deep bar. In this study, we attempt to interpret characteristics for double cage rotor or deep bar that occur when operating in the induction generator based on the parameters that have been designed and manufactured as an induction motor.

The Comparison of the Cerebral Motor Area Activation between Diagonal and Straight Exercises of the Lower Extremity -A Case Study- (하지의 대각선 운동과 직선 운동 시 대뇌 운동영역 활성도 비교 -사례연구-)

  • Lee, Seuong-Yun;Rhee, Min-Hyung
    • PNF and Movement
    • /
    • v.14 no.3
    • /
    • pp.231-236
    • /
    • 2016
  • Purpose: The purpose of this study was to compare cerebral motor area activation between the diagonal and straight movements of the lower extremity. Methods: The subjects of this study consisted of two right-handed adults. Functional magnetic resonance imaging was conducted to measure brain activation following the diagonal and straight movements of the lower extremity. The primary motor area, premotor area, and supplementary motor area, which are closely related to exercise, were set as the regions of interest. Results: The brain activation by diagonal movement was an average of $1036{\pm}75$ voxel, and brain activation by straight exercise was an average of $773{\pm}55$ voxel. Conclusion: Based on these results, we conclude that the activation of the cerebral motor area is more effective for diagonal movements than for straight movements.

An Equivalent Circuit for a Single-Phase Motor with Non-Quadrature Stator Windings (비대칭권선축단상전동기의 등가회로에 관해서)

  • Min Ho Park
    • 전기의세계
    • /
    • v.21 no.1
    • /
    • pp.7-12
    • /
    • 1972
  • General steady state equivalent circuits are derived for the family of single phase motor having two windings with non-quadrature. First, the fundamental voltage equations of motor are derived by Faraday-Krichhoff's low in the fiew of the flux distribution in the modified motor with Kron primitive machine. Those equations are arranged in to f-b equations by transformation matrix. To using the above equations for circuit; 1) The concept of current-source was much help to sove the realtions between matrix impedance equation and circuit analysis 2) The simplification of the circuit to the mutual impedance matrix elements is easy to considerations of motor characteristics in the case of inserted external auxiliary winding impedance. Finally, this equivalent circuit showing as a single phase induction motor with quadrature winding is described by each conditions.

  • PDF

The Study on the Characteristic Analysis of Controlled-PM LSM for Maglev Vehicle (제어-영구자석형 자기부상열차의 특성해석에 관한 연구)

  • Lee, Ju;Chun, Yon-Do;Lee, Kwan-Seop
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.450-457
    • /
    • 1998
  • Abstract - Linear Synchronous Motor has a large airgap comparing with rotary-type motor and especially, Permanent Magnet Linear Synchronous Motor(PM-LSM) which uses permanent magnet as a magnetic field, has a very large effective magnet airgap owing to permanent magnet structure. Accordingly, in case of 2-D analysis of the motor, the analysis error becomes large because leakage flux by which normal direction of the analysis region can not be considered, In this paper, the characteristic of PM-LSM for Maglev vehicle is analyzed exactly by 3-D Finite Element Method(3-D FEM). As the result, the effect of lateral-direction airgap magnetic flux density distribution on the analysis precision has been investigated and the motor characteristics according to primary motor parameter have been also made clear quantitatively. The accuracy of 3-D FEM has been confirmed by comparing the calculated results with the experimental results.

  • PDF

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

Failure Case-Study and Countermeasures of High-Voltage Motor with Inverter Drive System (인버터 구동에 따른 고압전동기 사고사례와 대책)

  • Choi Young-Chan;Woo Myung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.163-166
    • /
    • 2002
  • Recently, the insulation breakdown accident has been experienced at 6.6kV inverter driving motor. That brought about the reliability degradation of motor driving system.. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the Insulation system of motor which Is driven by inverter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of Insulation breakdown accidents.

  • PDF

An Analysis of Delayed Voltage Recovery Phenomenon according to the Characteristics of Motor Load in Korean Power System (모터부하 특성에 따른 국내 전력계통의 전압 지연 회복 현상 분석)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.178-182
    • /
    • 2016
  • FIDVR(Fault Induced Delayed Voltage Recovery) is a phenomenon that recovery of the system voltage level delays after the fault. Cause of FIDVR phenomenon is motor load characteristic about voltage and reactive power. In low voltage condition, the motor go to stall state that consume large amount of reactive power. As a result, the voltage recovery problem is that of repeated occurrences of sustained low voltage following faults on the system. In this paper, analysis the characteristics of the motor load. And using the korean power system actual data, perform a case studies to voltage delay recovery phenomenon alleviation method. Change of each parameters by analyzing the effect on system and selecting an influence parameter. In addition, dynamic characteristic analysis of the resulting difference in the proportion by the motor load in power systems, considering the effect on the voltage stability.

An Axial-type Self-bearing Motor for Small Vertical Axial-flow Pump (소형 수직형 축류 펌프를 위한 축방향 자기 부상 모터)

  • ;Yohji Okada
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.6
    • /
    • pp.223-232
    • /
    • 2001
  • Aiming at a small axial pump with a levitated rotor, an axial-type self-bearing motor is presented, which has a rotor wish four permanent magnets and two stators with two-pole three-phase windings. In this system, only the axial motion of rotor is actively controlled by two opposite self-bearing motors just like in the case of an axial magnetic bearing, while the other motions are passively stable. For rotation, It follows the theory of a four-pole three-phase synchronous motor. This paper Introduces schemes for design and control of the self-bearing motor and shows some experimental results to Prove the feasibility of application for the axial Pump.

  • PDF

Structure Design and Implementation of AC Servo Motor Control Program (AC 서보모터 제어 프로그램 구조 설계 및 구현)

  • Kyungah Kim;Joon-Young Choi
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.5
    • /
    • pp.209-215
    • /
    • 2023
  • This study proposes an AC servo motor control program structure and its implementation method to efficiently integrate 13 types of additional compensation algorithms into the basic FOC (field-oriented control) algorithm program. Various compensation algorithms are necessary to enhance the stability and performance of machine tools by compensating for interference from disturbances and vibrations. Each compensation algorithm is implemented as a separate, independent function and called from a switch-case statement in the ISR (interrupt service routine) of the PWM (pulse-width modulation) device. The advantages of this approach include facilitating not only debugging and testing but also reducing the possibility of errors during the program development phase. Thus, it is easy to add and activate each specific compensation algorithm for the program update during the program operation phase. The implemented motor control program was experimented with a single-axis feed shaft testbed driven by a commercial AC servo motor control drive board and a 750 Watts SPMSM (surface-mounted permanent magnet synchronous motor), and the results verified its normal operation and performance improvement.

A Case Report of Non-Motor Symptoms Evaluated Using the Non-Motor Symptom Scale in a Patient with Secondary Parkinsonism Presumed to be Probable Lewy Body Dementia and Improved with Combined Treatment with Herbal Medicine and Acupuncture (루이소체 치매로 추정되는 이차성 파킨슨증 환자의 Non-Motor Symptom Scale(NMSS)로 평가한 비운동성 증상을 한약과 침의 복합치료로 호전시킨 증례보고 1례)

  • Roh, Min-yeong;Lee, Ji-hyun;Han, Yang-hee;Leem, Jung-tae
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.833-845
    • /
    • 2021
  • Parkinson's syndrome is a degenerative brain disease that presents characteristic motor symptoms of tremor, rigidity, and gait disturbance. In addition to these motor symptoms, Parkinson's syndrome also presents non-motor symptoms (NMSs) such as sleep disturbance and cognitive decline. NMSs reduce patient's quality of life and psychosocial functioning and cause economic burden on the patient, so appropriate evaluation and treatment are required. Lewy body dementia is one of the several diseases belonging to Parkinson's syndrome. Its symptoms such as cognitive function, memory impairment, and hallucinations occur with Parkinsonism. Although drug therapy is being used with drug treatment to treat non-motor symptoms, it has limitations such as side effects, which stimulated interest in other complementary treatment methods such as oriental medicine treatment, dance, and yoga. The patient in this case complained of tremor in the right upper extremity, muscle hypertension and pain, and persistent vision, memory, and cognitive decline. The patient was diagnosed with probable Lewy body dementia. The patient was hospitalized for 4 months and received acupuncture and herbal medicines. After treatment, the patient's NMS scale scores decreased from 90 to 63, and the Unified Parkinson's Disease Rating Scale scores (summed I, II, and III) decreased from 17 points to 8 points. The Beck Depression Inventory score decreased from 22 points to 13 points. In addition, the patient's subjective evaluation revealed improvement. In this case, a patient diagnosed with probable Lewy body dementia who did not respond to the standard treatment and did not want to take medications showed improvement in not only motor symptoms but also NMSs after integrative Korean medicine treatment.