• Title/Summary/Keyword: motion of the moon

Search Result 850, Processing Time 0.025 seconds

An Experimental Study for Predicting the Electric Power of the Coaxial Accelerator Type Wave Power Generator (동축 가속형 파력 발전장치의 전력량 예측을 위한 실험 연구)

  • Chung, Jaeho;Shin, Dong Min;Kim, Yuncheol;Moon, Byung Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.19-24
    • /
    • 2020
  • The interest in renewable energy is increasing due to the depletion of fossil fuels. In particular, active research on wave power, which is highly predictable and abundant, is being conducted. The coaxial accelerator-type wave power generator used in this study was designed to improve the power generation efficiency by converting bidirectional linear motion into a rotational force. In an offshore engineering basin, waves were generated, and case tests were performed according to the wave period and wave height. The experimental results were verified by the theoretical method related to the frequency response, and the overall trend was confirmed to be consistent. These results are expected to be useful in estimating the power of wave generators and designing parameters to improve the efficiency of wave energy in the design stage before manufacturing. In addition, the manufacturer can predict the wave energy efficiency of wave generators, which can reduce the development time and cost by preventing trial and error processes.

Analysis of Features of Korean Fourth Grade Students' TIMSS Science Achievement in Content Domains with Curriculum Change (교육과정 변화에 따른 우리나라 초등학교 4학년 학생들의 TIMSS 과학 내용영역별 성취 특성 분석)

  • Kwak, Youngsun
    • Journal of The Korean Association For Science Education
    • /
    • v.37 no.4
    • /
    • pp.599-609
    • /
    • 2017
  • The goal of this research is to analyze the trend of Korean fourth grade students' achievement in TIMSS 2011 and TIMSS 2015 science content domains and to suggest implications for science curriculum and teaching & learning improvement. With four elementary science teachers and three science educators, we analyzed Korean fourth grade students' percentage of correct responses in TIMSS 2015 science content and cognitive domains, and conducted item-curriculum matching analysis for test items. According to the results, Korean students performed relatively better in test topics covered in the science curriculum for 3-4 grades regardless of the science content domain (i.e., Life science, Physical science, or Earth science). Korean students showed low percentage of correct answers for items related to such topics as heat conduction, the action of electricity, the motion of the earth and the moon, etc., which were covered in the 5th-6th grades in the 2009 revised curriculum. For science cognitive domains, Korean students' achievement dropped significantly in reasoning between TIMSS 2011 and TIMSS 2015. Discussed in the conclusion are implications to reconstruct elementary school science curriculum, and ways to improve science teaching and learning.

Para-articular chondroma in the infrapatellar fat pad - A case report - (슬개하 지방체에 발생한 관절 주위 연골종 - 증례 보고 -)

  • Nam, Il-Hyun;Ahn, Gil-Yeong;Moon, Gi-Hyuk;Lee, Yeong-Hyeon;Choi, Seong-Pil;Kim, Jung-Hyun;Paik, Ae-Lan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.105-108
    • /
    • 2011
  • Extra-skeletal chondroma, characterized by its lack of connection with the adjacent bone, includes synovial chondromatosis, intra-articular and para-articular chondroma, and soft tissue chondroma. Among them, the last two lesions are extremely rare. This is the case about 20-year-old soldier, who had complained of tenderness of the knee, pain and fullness during knee flexion and limitation of motion after a hard military training. We found a mass in the x-ray and MRI and resect the mass surgically, which was a $5.5{\times}4{\times}3$ cm size hard solitary mass. On microscopic finding, it was consisted of lobulated hyaline cartilage and outer fibrous capsule, and we ascertained it as para-articular chondroma. We experienced a case of para-articular chondroma in the infrapatellar fat pad of the knee joint and present its clinical, radiologic and pathologic findings with literature review.

  • PDF

The Diagnostic Value of Dynamic US in the Extensor Tendon Dislocation at the Metacarpophalangeal Joint (중수지 관절부 신전건 탈구에서 실시간 표시 초음파의 진단적 가치)

  • Moon, Eun-Sun;Park, Yong-Cheol;Kim, Myung-Sun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Purpose: We studied the diagnostic value of dynamic US in the extensor tendon dislocation at the metacarpophalangeal joint. Materials and Methods: From January 2007 to October, we studied 6 cases that had been diagnosed and followed over 5 months (2-10) in average. US examination using a 10-MHz linear transducer were performed in three cases. The causes of dislocations were traumatic in 5 cases and congenital in one case. Results: In only 3 cases which could not be diagnosed clinically, we performed US. In dynamic US, all three cases showed the extensor tendon dislocation evidently. Operative findings were sagittal band rupture in 4 cases, capsular loosening in one case and sagittal band thinning in one case. Sagittal band repair was performed in 4 cases and capsular augmentation in one case. In case of congenital dislocation showing 4 digital extensor tendon dislocations in right hand, we operated only the second extensor by sagittal band repair with augmentation by looping. At last follow-up, no case showed recurrence or limitation of motion. Conclusion: In case of extensor tendon dislocation without apparent clinical finding, US with dynamic study has so great value that it can detect the dislocation in real time, which is superior to MRI.

  • PDF

A Study on the Traffic Simulation for Autonomous Vehicles Considering Weather Environment (기상 환경을 고려한 자율주행 차량용 교통 시뮬레이션에 관한 연구)

  • Seo-Young Lee;Sung-Jung Yong;Hyo-Gyeong Park;Yeon-Hwi You;Il-Young Moon
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.36-42
    • /
    • 2023
  • The development of autonomous vehicles are currently being actively carried out by various companies and research institutes. Expectations for commercialization in daily life as well as specific industries are also rising. Simulators for autonomous vehicles are an essential element in algorithm development and execution considering stability and cost. In this need, various simulators and platforms for simulators are emerging, but research on simulations that reflect various meteorological environmental factors in the real world is still insufficient. This paper proposes a traffic simulation for autonomous vehicles that can consider the weather environment. The weather environment that can be set is largely classified into four categories, and an improved collision prevention algorithm to apply them is presented. Simulation development was conducted through Carla's Python API, a development tool for autonomous driving, and the performance results were compared with existing collision algorithms. Through this, we tried to propose improvements for the development of advanced self-driving vehicle simulations that can reflect various weather environmental factors in real life.

Acutrak Screw Fixation for Radial Head Fracture -7 Cases Report- (Acutrak 나사를 이용한 요골두 골절의 치료 -7례 보고-)

  • Kim, Kwang-Yul;Lim, Moon-Sup;Shin, Heung-Sub;Choi, Shin-Kwon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: To evaluate the efficiency of Acutrak screw fixation for radial head fracture (Mason type 2) without considering the safe Bone of radial head. Materials and Methods: Consecutive seven radial head fracture of Mason type II underwent internal fixation with Acutrak screws from May 2001 to February 2003. The mean follow-up period was 1.2years (ranged, $6 months{\sim}2.5 years$). The mean age of patients was 47 years old (ranged, $36{\sim}60years$ old). The cause of injury were fall down -4 cases and traffic accident -3 cases. The results were evaluated by Mayo Clinic results scoring system. Results: Functional Rating Index of Mayo Clinic was excellent- 2 cases and good- 5 cases. There were no nonunion, loosening, heterotopic ossification, infection or degenerative changes. The postoperative range of motion in elbow joint is nearly full for flexion, extension, pronation and supination in this study Conclusion: Consideration of safe zone is not necessary when Acutrak screws are used for radial head fracture. It seems to be a useful method that Acutrak screw fixation for radial head fracture (Mason type II) could achieve good radiologic and clinical results without influencing proximal radio-ulnar joint and has powerful fixation.

  • PDF

Blind and Ultrasonography-guided Injection Therapy for Calcific Tendinitis of Supraspinatus (극상건 석회화 건염에 대한 맹검 주사요법과 초음파하 주사요법)

  • Moon, Young-Lae;Nam, Gi-Young;Noh, Kyung-Hwan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.86-90
    • /
    • 2008
  • Purpose: To evaluate the differences between blindly and ultrasonography (US)-guided during multiple needling and dextrose injection technique for calcific tendinitis of shoulder. Materials and Methods: We chose 36 symptomatic calcific tendinitis patients, whose age ranged from 27 to 69. Our procedures were multiple needling and injection of dextrose over the lesion of calcific deposits. The bind injection group were 19 patients whose age ranged from 27 to 64-year-old (mean 52.2), and the US-guided injection group were 17 patients ranged from 31 to 69-year-old (mean 49.0). We compare these groups by VAS (visual analogue scale) and range of motion before and after procedures. Results: There is no difference between two groups in VAS and ROM before procedure (p>0.05). Two groups revealed significant improvement without limitation of shoulder function, however, the group under US-guided revealed better results than under blind (VAS:p=0.001, Flexion:p=0.000, Abduction:p=0.000, External rotation: p=0.016). Conclusion: Ultrasonography-guided procedure showed better results than blind, so the use of ultrasonography is more promising procedure.

  • PDF

Array Bounds Check Elimination using Ineguality Graph in Java Just-in-Time Compiler (대소관계 그래프를 이용한 Just-in-Time 컴파일 환경에서의 배열 경계 검사 제거)

  • Choi Sun-il;Moon Soo-mook
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.12
    • /
    • pp.1283-1291
    • /
    • 2005
  • One of the problems in boosting Java performance using a Just-in-Time (JIT) compiler is removing redundant array bound checks. In conventional static compilers, many powerful algorithms have been developed, yet they are not directly applicable to JIT compilation where the compilation time is part of the whole running time. In the current JIT compilers, we tan use either a naive algorithm that is not powerful enough or an aggressive algorithm which requires the transformation into a static single assignment (SSA) form of programs (and back to the original form after optimization), thus causing too much overhead not appropriate for JIT compilation This paper proposes a new algorithm based on an inequality graph which can eliminate array bounds check codes aggressively without resorting to the SSA form. When we actually perform this type of optimization, there are many constraints in code motion caused by the precise exception rule in Java specification, which would cause the algorithm to miss many opportunities for eliminating away bound checks. We also propose a new method to overcome these constraints.

Design of a Low Noise 6-Axis Inertial Sensor IC for Mobile Devices (모바일용 저잡음 6축 관성센서 IC의 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.397-407
    • /
    • 2015
  • In this paper, we designed 1 chip IC for 3-axis gyroscope and 3-axis accelerometer used for various IoT/M2M mobile devices such as smartphone, wearable device and etc. We especially focused on analysis of gyroscope noise and proposed new architecture for removing various noise generated by gyroscope MEMS and IC. Gyroscope, accelerometer and geo-magnetic sensors are usually used to detect user motion or to estimate moving distance, direction and relative position. It is very important element to designing a low noise IC because very small amount of noise may be accumulated and affect the estimated position or direction. We made a mathematical model of a gyroscope sensor, analyzed the frequency characteristics of MEMS and circuit, designed a low noise, compact and low power 1 chip 6-axis inertial sensor IC including 3-axis gyroscope and 3-axis accelerometer. As a result, designed IC has 0.01dps/${\sqrt{Hz}}$ of gyroscope sensor noise density.

Prediction of Salvaged Myocardium in Patients with Acute Myocardial Infarction after Primary Percutaneous Coronary Angioplasty using early Thallium-201 Redistribution Myocardial Perfusion Imaging (급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상을 이용한 구조심근 예측)

  • Choi, Joon-Young;Yang, You-Jung;Choi, Seung-Jin;Yeo, Jeong-Seok;Park, Seong-Wook;Song, Jae-Kwan;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.219-228
    • /
    • 2003
  • Purpose: The amount of salvaged myocardium is an important prognostic factor in patients with acute myocardial infarction (MI). We investigated if early Tl-201 SPECT imaging could be used to predict the salvaged myocardium and functional recovery in acute MI after primary PTCA. Materials and Methods: In 36 patients with first acute MI treated with primary PTCA, serial echocardiography and Tl-201 SPECT imaging ($5.8{\pm}2.1$ days after PTDA) were performed. Regional wall motion and perfusion were quantified with on 16-segment myocardial model with 5-point and 4-point scaling system, respectively. Results: Wall motion was improved in 78 of the 212 dyssynergic segments on 1 month follow-up echocardiography and 97 on 7 months follow-up echocardiography, which were proved to be salvaged myocardium. The areas under receiver operating characteristic curves of Tl-201 perfusion score for detecting salvaged myocardial segments were 0.79 for 1 month follow-up and 0.83 for 7 months follow-up. The sensitivity and specificity of Tl-201 redistribution images with optimum cutoff of 40% of peak thallium activity for detecting salvaged myocardium were 84.6% and 55.2% for 1 month follow-up, and 87.6% and 64.3% for 7 months follow-up, respectively. There was a linear relationship between the percentage of peak thallium activity on early redistribution imaging and the likelihood of segmental functional improvement 7 months after reperfusion. Conclusion: Tl-201 myocardial perfusion SPECT imaging performed early within 10 days after reperfusion can be used to predict the salvaged myocardium and functional recovery with high sensitivity during the 7 months following primary PTCA in patients with acute MI.