• 제목/요약/키워드: monitoring module

검색결과 834건 처리시간 0.028초

자동차 ECU 자기진단 신호의 원격계측 시스템 (Remote Measuring System for Automobile′s ECU Self Diagnostic Signal)

  • 정진호;윤여흥;이영춘;권대규;이성철
    • 한국정밀공학회지
    • /
    • 제19권5호
    • /
    • pp.159-167
    • /
    • 2002
  • In this paper. we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and designed terminal according to the IOS, SAE regulation of communication protocol standard. Micro-processor 80C196KC is used for communicating ECU's self diagnositc signals and the results are sent to the wireless terminal and PC monitoring system. Wireless terminal is also developed by 80C196KC, LCD, RF module, and keypad. The command from the keypad is sent to ECU through RF module and the result show on the Graphic LCD in real time. Software on PC is developed to monitor the ECU's self diagnostic signals using the Visual C++ complier in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor both ECU and portable terminal state. At the same time, the information to fix the vehicle's problem can be shown on the developed software. The possibility for remote measurement of ECU self diagnostic signal is verified through the developed systems and algorithms.

레이저 미세가공 공정 요소 모니터링 기술 (Laser Micro-machining Process-monitoring Technologies)

  • 손현기;이제훈;한재원;김호상
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.34-39
    • /
    • 2010
  • In order to achieve and maintain dimensional accuracy in laser micro-machining, dominant parameters such as laser power and laser focus position need to be monitored and controlled real time. Also, in order to selectively machine multi-layered materials, the material being presently machined need to be recognized. This paper presents an auto-focusing (AF) module to keep laser focus on a large-area surface; a real-time laser power stabilizing module based on optical attenuation; and a laser-induced breakdown spectroscopy (LIBS) module. With these monitoring modules, position error in laser focus on a 4" silicon wafer was kept below $4{\mu}m$, initially $51{\mu}m$, and laser power stability of a UV laser source was improved from 1.6% to 0.3%. Also, the material transition from polyimide to copper in machining of FCCL (flexible copper clad laminate) was successfully observed.

전기자동차 배터리 모듈용 직접 셀 전하 균등화 회로 (A Direct Cell-to-Cell Charge Balancing Circuit for the EV Battery Module)

  • 팜반롱;응웬킴헝;간 압둘바싯;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.401-402
    • /
    • 2015
  • In this paper a direct cell-to-cell charge balancing circuit which can transfer the charge from any cell to any cell in the battery string is introduced. In the proposed topology the energy in the high voltage cell is transferred to the low voltage cell through the simple operation of a dc-dc converter to get fast equalization. Furthermore, the charge equalization can be performed regardless of the battery module operation whether it is being charged, discharged or relaxed. The monitoring circuit composed of a DSP and a battery monitoring IC is designed to monitor the cell voltage and protect the battery. In order to demonstrate the advantages of the proposed topology, a prototype circuit was designed and applied to 12 Lithium-Ion battery module. It has been verified with the experiments that the charge equalization time of the proposed method was shortest compared with those of other methods.

  • PDF

장기간 소자 모니터링이 용이한 소형 무선랜 무선송신 계측장치 개발 (Development of Portable Measurement Unit with Wireless Transmission by Wireless LAN for Long-term Monitoring)

  • 박소정;박일후;문영선;이국진;김규태
    • 반도체디스플레이기술학회지
    • /
    • 제17권1호
    • /
    • pp.45-49
    • /
    • 2018
  • Portable microcontroller based measurement unit is demonstrated using digital-to-analog convertor module, analog-to-digital convertor module and additional preamplifier circuit with low-budget but excellent performances. Using the designed measurement unit, the measurement of current below 1 nA with applying voltage up to 5 V is successfully carried out. With the WiFi module in microcontroller, measured data is transferred to the user's computer. To evaluate the performance of the measurement unit, the transfer curve of a commercial N-type field effect transistor was measured with the measurement unit and the results is well consistent with that measured using commercial characterization system.

Implementation of Falling Accident Monitoring and Prediction System using Real-time Integrated Sensing Data

  • Bonghyun Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권11호
    • /
    • pp.2987-3002
    • /
    • 2023
  • In 2015, the number of senior citizens aged 65 and over in Korea was 6,662,400, accounting for 13.1% of the total population. Along with these social phenomena, risk information related to the elderly is increasing every year. In particular, a fall accident caused by a fall can cause serious injury to an elderly person, so special attention is required. Therefore, in this paper, we implemented a system that monitors fall accidents and informs them in real time to minimize damage caused by falls. To this end, beacon-based indoor location positioning was performed and biometric information based on an integrated module was collected using various sensors. In other words, a multi-functional sensor integration module was designed based on Arduino to collect and monitor user's temperature, heart rate, and motion data in real time. Finally, through the analysis and prediction of measurement signals from the integrated module, damage from fall accidents can be reduced and rapid emergency treatment is possible. Through this, it is possible to reduce the damage caused by a fall accident, and rapid emergency treatment will be possible. In addition, it is expected to lead a new paradigm of safety systems through expansion and application to socially vulnerable groups.

Embedded Linux 기반 무인비행로봇의 저가 고정밀 위치 모니터링 시스템 구현 연구 (An Implementation Study on a Low-cost High-accuracy Position Monitoring System for Unmanned Flying Robots)

  • 임준후;김희성;이제영;최광호;조정호;이형근
    • 제어로봇시스템학회논문지
    • /
    • 제20권12호
    • /
    • pp.1196-1203
    • /
    • 2014
  • Recently, UFRs (Unmanned Flying Robots) have begun to be utilized in various areas for civilian and military applications. Due to this increased utilization, accidents involving UFRsare also increasing. To prevent or monitor accidents caused by UFRs, high-accuracy positioning information is one of the most important technical elements. This paper proposes an efficient UFR monitoring system which provides accurate UFR positioning information with low-cost onboard elements; a small ARM module based on an embedded Linux operating system, a low-cost single frequency GPS receiver with a cheap patch antenna, and a versatile wireless network interface module. The ground monitoring system employs a dual frequency GPS receiver to generate exact UFR coordinates with cm-level accuracy. By processing the UFR measurements based on the Inverse RTK (Real Time Kinematic) method, the ground monitoring system determines the cm-level accurate coordinates of the UFR. The feasibility of the proposed UFR monitoring system was evaluated by three experiments in terms of data loss and accuracy.

Implementation of a bio-inspired two-mode structural health monitoring system

  • Lin, Tzu-Kang;Yu, Li-Chen;Ku, Chang-Hung;Chang, Kuo-Chun;Kiremidjian, Anne
    • Smart Structures and Systems
    • /
    • 제8권1호
    • /
    • pp.119-137
    • /
    • 2011
  • A bio-inspired two-mode structural health monitoring (SHM) system based on the Na$\ddot{i}$ve Bayes (NB) classification method is discussed in this paper. To implement the molecular biology based Deoxyribonucleic acid (DNA) array concept in structural health monitoring, which has been demonstrated to be superior in disease detection, two types of array expression data have been proposed for the development of the SHM algorithm. For the micro-vibration mode, a two-tier auto-regression with exogenous (AR-ARX) process is used to extract the expression array from the recorded structural time history while an ARX process is applied for the analysis of the earthquake mode. The health condition of the structure is then determined using the NB classification method. In addition, the union concept in probability is used to improve the accuracy of the system. To verify the performance and reliability of the SHM algorithm, a downscaled eight-storey steel building located at the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark structure. The structural response from different damage levels and locations was collected and incorporated in the database to aid the structural health monitoring process. Preliminary verification has demonstrated that the structure health condition can be precisely detected by the proposed algorithm. To implement the developed SHM system in a practical application, a SHM prototype consisting of the input sensing module, the transmission module, and the SHM platform was developed. The vibration data were first measured by the deployed sensor, and subsequently the SHM mode corresponding to the desired excitation is chosen automatically to quickly evaluate the health condition of the structure. Test results from the ambient vibration and shaking table test showed that the condition and location of the benchmark structure damage can be successfully detected by the proposed SHM prototype system, and the information is instantaneously transmitted to a remote server to facilitate real-time monitoring. Implementing the bio-inspired two-mode SHM practically has been successfully demonstrated.

Implementation of Air Pollutant Monitoring System using UAV with Automatic Navigation Flight

  • Shin, Sang-Hoon;Park, Myeong-Chul
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권8호
    • /
    • pp.77-84
    • /
    • 2022
  • 본 논문에서는 자동항법 비행이 가능한 무인기를 활용하여 미세먼지 등의 대기 오염물질을 모니터링 하는 시스템을 제안한다. 기존 대기 질 관리 시스템은 고정된 센서 박스를 통한 관제나 조종장치를 이용한 드론의 측정 센서를 통하여 정보를 취득하는 방식을 사용했다. 이는 한정된 공간과 모니터링을 위한 별도의 데이터 수집 및 전송들의 추가적인 절차가 진행되어야 하는 단점을 가진다. 본 논문에서 이러한 문제점을 극복하기 위하여 비행정보 지정을 통한 자율항법 비행이 가능한 무인기에 위치 정보를 위한 GPS 모듈과 미세먼지 측정을 위한 PMS7003 모듈을 내장하고 수집된 정보는 SD 모듈에 저장하고 비행 종료 후 전송버튼을 통해 블루투스로 연결된 스마트폰 앱을 통하여 원격 데이터베이스에 저장되는 원스톱 구조의 시스템을 구성한다. 또한, 실시간 모니터링을 위한 HTML5 기반의 웹 모니터링 페이지를 구성하여 관심 사용자에게 제공된다. 본 연구의 결과는 무인 비행체를 통한 환경 모니터링 시스템에 활용될 수 있으며, 향후 아황산가스 및 이산화탄소 등의 다양한 오염물질 측정 센서를 추가하여 토털 환경 관제 시스템으로 발전시키고자 한다.

무선센서 네트워크에 의한 지하 통신구 터널 모니터링 연구 (Cable Tunnel Monitoring System by Wireless Sensor Network)

  • 김형우;문태균
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.549-552
    • /
    • 2008
  • In this study, we deployed the cable tunnel inspection and monitoring system by wireless sensor network. It is shown that the wireless sensor network which is composed of sensor, wireless communication module, and gateway can be applied to cable tunnel monitoring system. Sensors considered herein are flame detection sensor, flood detection sensor, intruder detection sensor, and temperature sensor, etc. It is also found that the wireless sensor network can deliver sensing data reliably by wireless sensing technology. The gateway system that can transmit sensed data to server by CDMA is developed. Monitoring system is constructed by web service technology, and it is observed that this system can monitor the present state of tunnel without difficulties. The system provides an alternative to inspecting and monitoring the tunnel efficiently where the conventional wired system is infeasible.

  • PDF

모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양 (Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications)

  • 우응제;박승훈;전병문;문창욱;이희철;김승태;김형진;서재준;채경명;박종찬;최근호;이왕진;김경수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF