• Title/Summary/Keyword: monitoring module

Search Result 834, Processing Time 0.039 seconds

Case Study on 5kWp Transparent Thin-Film BIPV System (5kW급 투광형 박막 BIPV시스템의 실증연구)

  • An, Young-Sub;Kim, Sung-Tae;Lee, Sung-Jin;Song, Jong-Hwa;Hwang, Sang-Kun;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.29-35
    • /
    • 2010
  • This study has been carried out empirical research on Transparent Thin-film BIPV modules, BIPV modules installed on the exterior of the building are applied a laminated module 1kWp, double-glazing module 3kWp and triple-glazing module 1kWp. Applied to the total capacity of BIPV modules are 5kWp. In this study, design and construction process of BIPV systems is presented. In addition, through monitoring of the BIPV system, the temperature and the power characteristics of each module were analyzed. During the measurement period, the module temperature measurement results, the maximum surface temperature of $51.5^{\circ}C$ triple-glazing BIPV module showed the highest, followed by double-glazing BIPV module $49.1^{\circ}C$, $44.7^{\circ}C$ laminated modules, respectively. Power output results, the daily average double-layer modules showed 4.10kWh/day, triple-glazing module 1.57kWh, respectively 1.81kWh laminated modules. In particular, the power efficiency of triple-glazing BIPV module was lower than the power efficiency of the laminated BIPV module. This phenomenon is considered to be affected by the module temperature. In the future, BIPV modules in this study the relationship between module temperature and power characteristics plans to identify.

A Mobile Robot for Nuclear Power Plant Applications

  • Kim, Chang-Hoi;Seo, Yong-Chil;Cho, Jai-Wan;Choi, Young-Soo;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.803-807
    • /
    • 2003
  • Tele-operation and remote monitoring techniques are essential and important technologies for performing the inspection and repair tasks effectively in nuclear power plants. This paper presents the application of a mobile robot for the remote monitoring and inspection of the Calandria faces, where human access is limited because of the high-level radioactive environments during full power operation. The mobile robot was designed with reconfigurable crawler type of wheels attached on the front and rear side in order to pass through the ditch. The extendable mast, mounted on the mobile robot, can be extended up to 8 m vertically. This robot was also equipped a visible CCD/thermal infrared inspection head module and a stereo camera module for the enhancement of visual inspection.

  • PDF

Distributed NC with Tool Managenent System Under the Windows Environment (윈도우즈 환경하에서의 Distributed NC 및 공구관리 시스템)

  • Un, Yool;Shin, D. S.;Chung, S. C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.411-416
    • /
    • 1993
  • In order to achieve computer-oriented control and automation of manufacturing processec, a distributed NC (DNC_) system was developed for FMS under the Windows environment. The DNC system consists of conventional DNC, PMC interface and tool management modules. Real-time system conditon monitoring and control fuctions required for machine tools and machining processes were accomplished by developing a PMC interface module called MMC board. Tool condition monitoring and management was performed by the developed tool management module composed of a tool setting probe and softwares. Performance of the DNC system was confirmed on the horizontal and the vertical type machining center equipped with FANUC OMC for the large amount of experiments.

  • PDF

Fault Diagnosis in Gas Turbine Engine Using Fuzzy Inference Logic (퍼지 로직 시스템을 이용한 항공기 가스터빈 엔진 오류 검출에 대한 연구)

  • Mo, Eun-Jong;Jie, Min-Seok;Kim, Chin-Su;Lee, Kang-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2008
  • A fuzzy inference logic system is proposed for gas turbine engine fault isolation. The gas path measurements used for fault isolation are exhaust gas temperature, low and high rotor speed, and fuel flow. The fuzzy inference logic uses rules developed from a model of performance influence coefficients to isolate engine faults while accounting for uncertainty in gas path measurements. Inputs to the fuzzy inference logic system are measurement deviations of gas path parameters which are transferred directly from the ECM(Engine Control Monitoring) program and outputs are engine module faults. The proposed fuzzy inference logic system is tested using simulated data developed from the ECM trend plot reports and the results show that the proposed fuzzy inference logic system isolates module faults with high accuracy rate in the environment of high level of uncertainty.

A Novel Approach to Trojan Horse Detection in Mobile Phones Messaging and Bluetooth Services

  • Ortega, Juan A.;Fuentes, Daniel;Alvarez, Juan A.;Gonzalez-Abril, Luis;Velasco, Francisco
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.8
    • /
    • pp.1457-1471
    • /
    • 2011
  • A method to detect Trojan horses in messaging and Bluetooth in mobile phones by means of monitoring the events produced by the infections is presented in this paper. The structure of the detection approach is split into two modules: the first is the Monitoring module which controls connection requests and sent/received files, and the second is the Graphical User module which shows messages and, under suspicious situations, reports the user about a possible malware. Prototypes have been implemented on different mobile operating systems to test its feasibility on real cellphone malware. Experimental results are shown to be promising since this approach effectively detects various known malware.

DTS-based Temperature Monitoring and Analysis of Battery Cell Deterioration Characteristics by Temperature Condition (DTS 기반 온도 감시 및 온도 조건에서의 배터리 셀 열화 특성 분석)

  • SoonJong, Kwon;Soo-Yeon, Kim;Jin, Hwang;Sang-Kyun, Woo;Bong-Suck, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • As ESS safety issues increase recently, there is a need to more precisely monitor the temperature of the ESS. In this paper, DTS technology for temperature monitoring of ESS batteries is introduced and the temperature measurement principle is explained. The temperature of the battery module is measured using the DTS system, and the thermal deviation between battery cells inside the battery module is analyzed. In order to analyze how thermal imbalance affects the charging and discharging performance of the battery, an accelerated degradation test was conducted. Cycle life characteristics analysis, battery surface temperature change, and AC impedance characteristics were conducted to analyze how the performance of battery cells differs according to temperature conditions.

LTE Cat.M1 Communication Module for Fishing Gear Automatical Identification Monitoring System (어구 자동식별 모니터링을 위한 LTE Cat.M1 통신 모듈)

  • Kim, Seong-Yuel;Lee, Doo-Cheon;Kim, Kwang-On;Yim, Choon-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.682-685
    • /
    • 2021
  • The design and fabrication of LTE Cat.M1 (3GPP Release13 Standardization) modules of ships such as fishing boat and patrol boat are reported in this research. LTE cat.M1 modules are needed to expand the for broadening of IoT services through the ships used in fishing gear automatically identification monitoring system, which is one of applying ICT into the real name system of electric fishing gear.

  • PDF

An Integrated Sensor Module for Diagnosis of Closed Switchboards (수배전반 진단을 위한 통합형 센서모듈)

  • Cha, Sang-Wook;Cha, Hyeon-Kyu;Park, Dae-Won;Park, Hee-Chul;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2043-2048
    • /
    • 2011
  • According to the statistical report from National Emergency Management Agency (NEMA) in Korea, the accident rate of closed switchboards in power systems occupies over 40%. In this paper, an integrated sensor module for monitoring the condition of closed switchboards is described. The sensor module monitors electro-magnetic (EM) wave, ultra-violet (UV) ray, heat and smoke generated by electrical discharges or insulation breakdown. The effective detection ranges were decided from experiment results; 100 kHz~10 MHz for EM wave, 220 nm~395 nm for UV ray and 0~$150^{\circ}C$ for heat, respectively. The prototype sensor module includes all functions above-mentioned in one device.

  • PDF

Development of Low-Cost Automatic Flight Control System for Unmanned Target Drone

  • Lee, Jang-Ho;Ryu, Hyeok;Kim, Jae-Eun;Ahn, Iee-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.367-371
    • /
    • 2004
  • This paper describes development of automatic flight control system for an unmanned target drone which is operated by Korean army as for anti-air gun shooting training. Current target drone is operated by pilot control of on-board servo motor via remote control system. Automatic flight control system for the target drone greatly reduces work load of ground pilot and can increase application area of the drone. Most UAVs being operated now days use high-priced sensors as AHRS and IMU to measure the attitude, but those are costly. This paper introduces the development of low-cost automatic flight control system with low-cost sensors. The integrated automatic flight control system has been developed by integrating combining power module, switching module, monitoring module and RC receiver as an one module. The performance of automatic flight control system is verified by flight test.

  • PDF

RF front-end Module for On-Line UHF Partial-discharge Monitoring System

  • Lee June Young;Kim Bok Ki
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.776-779
    • /
    • 2004
  • A RF front-end module is designed for GIS(Gas Insulated Substation) which is employed for effective and efficient very high voltage transmission. Major advantage of the unit is improved PO detection sensitivity through minimizing the effect of surrounding interference signals, which is achieved by controlling the gain and the selection of the frequency band, for the precise detection of any UHF PO (Partial Discharge) disturbance occurred in the GIS due to some unwanted problems. For the development of the module, various switches for providing selected signal paths, wideband LNA, 3 BPF for selecting detection frequency band, and video detector are designed, fabricated and measured on 1 mm FR4 substrate with various RF components. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PO signals as low as 1 pC. It is believed that the value is enough to detect the signal occurred in GIS.

  • PDF