Remote Measuring System for Automobile′s ECU Self Diagnostic Signal (자동차 ECU 자기진단 신호의 원격계측 시스템)

  • Jeong, Jin-Ho;Yun, Yeo-Heung;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.159-167
    • /
    • 2002
  • In this paper. we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and designed terminal according to the IOS, SAE regulation of communication protocol standard. Micro-processor 80C196KC is used for communicating ECU's self diagnositc signals and the results are sent to the wireless terminal and PC monitoring system. Wireless terminal is also developed by 80C196KC, LCD, RF module, and keypad. The command from the keypad is sent to ECU through RF module and the result show on the Graphic LCD in real time. Software on PC is developed to monitor the ECU's self diagnostic signals using the Visual C++ complier in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor both ECU and portable terminal state. At the same time, the information to fix the vehicle's problem can be shown on the developed software. The possibility for remote measurement of ECU self diagnostic signal is verified through the developed systems and algorithms.

Laser Micro-machining Process-monitoring Technologies (레이저 미세가공 공정 요소 모니터링 기술)

  • Sohn, Hyon-Kee;Lee, Jae-Hoon;Hahn, Jae-Won;Kim, Ho-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.34-39
    • /
    • 2010
  • In order to achieve and maintain dimensional accuracy in laser micro-machining, dominant parameters such as laser power and laser focus position need to be monitored and controlled real time. Also, in order to selectively machine multi-layered materials, the material being presently machined need to be recognized. This paper presents an auto-focusing (AF) module to keep laser focus on a large-area surface; a real-time laser power stabilizing module based on optical attenuation; and a laser-induced breakdown spectroscopy (LIBS) module. With these monitoring modules, position error in laser focus on a 4" silicon wafer was kept below $4{\mu}m$, initially $51{\mu}m$, and laser power stability of a UV laser source was improved from 1.6% to 0.3%. Also, the material transition from polyimide to copper in machining of FCCL (flexible copper clad laminate) was successfully observed.

A Direct Cell-to-Cell Charge Balancing Circuit for the EV Battery Module (전기자동차 배터리 모듈용 직접 셀 전하 균등화 회로)

  • Pham, Van-Long;Nguyen, Kim-Hung;Basit, Khan Abdul;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.401-402
    • /
    • 2015
  • In this paper a direct cell-to-cell charge balancing circuit which can transfer the charge from any cell to any cell in the battery string is introduced. In the proposed topology the energy in the high voltage cell is transferred to the low voltage cell through the simple operation of a dc-dc converter to get fast equalization. Furthermore, the charge equalization can be performed regardless of the battery module operation whether it is being charged, discharged or relaxed. The monitoring circuit composed of a DSP and a battery monitoring IC is designed to monitor the cell voltage and protect the battery. In order to demonstrate the advantages of the proposed topology, a prototype circuit was designed and applied to 12 Lithium-Ion battery module. It has been verified with the experiments that the charge equalization time of the proposed method was shortest compared with those of other methods.

  • PDF

Development of Portable Measurement Unit with Wireless Transmission by Wireless LAN for Long-term Monitoring (장기간 소자 모니터링이 용이한 소형 무선랜 무선송신 계측장치 개발)

  • Park, So Jeong;Park, Il-Hoo;Moon, Young-Sun;Lee, Kook Jin;Kim, Gyu-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.45-49
    • /
    • 2018
  • Portable microcontroller based measurement unit is demonstrated using digital-to-analog convertor module, analog-to-digital convertor module and additional preamplifier circuit with low-budget but excellent performances. Using the designed measurement unit, the measurement of current below 1 nA with applying voltage up to 5 V is successfully carried out. With the WiFi module in microcontroller, measured data is transferred to the user's computer. To evaluate the performance of the measurement unit, the transfer curve of a commercial N-type field effect transistor was measured with the measurement unit and the results is well consistent with that measured using commercial characterization system.

Implementation of Falling Accident Monitoring and Prediction System using Real-time Integrated Sensing Data

  • Bonghyun Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.2987-3002
    • /
    • 2023
  • In 2015, the number of senior citizens aged 65 and over in Korea was 6,662,400, accounting for 13.1% of the total population. Along with these social phenomena, risk information related to the elderly is increasing every year. In particular, a fall accident caused by a fall can cause serious injury to an elderly person, so special attention is required. Therefore, in this paper, we implemented a system that monitors fall accidents and informs them in real time to minimize damage caused by falls. To this end, beacon-based indoor location positioning was performed and biometric information based on an integrated module was collected using various sensors. In other words, a multi-functional sensor integration module was designed based on Arduino to collect and monitor user's temperature, heart rate, and motion data in real time. Finally, through the analysis and prediction of measurement signals from the integrated module, damage from fall accidents can be reduced and rapid emergency treatment is possible. Through this, it is possible to reduce the damage caused by a fall accident, and rapid emergency treatment will be possible. In addition, it is expected to lead a new paradigm of safety systems through expansion and application to socially vulnerable groups.

An Implementation Study on a Low-cost High-accuracy Position Monitoring System for Unmanned Flying Robots (Embedded Linux 기반 무인비행로봇의 저가 고정밀 위치 모니터링 시스템 구현 연구)

  • Lim, Joonhoo;Kim, Hee Sung;Lee, Je Yong;Choi, Kwang Ho;Cho, Jeongho;Lee, Hyung Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.12
    • /
    • pp.1196-1203
    • /
    • 2014
  • Recently, UFRs (Unmanned Flying Robots) have begun to be utilized in various areas for civilian and military applications. Due to this increased utilization, accidents involving UFRsare also increasing. To prevent or monitor accidents caused by UFRs, high-accuracy positioning information is one of the most important technical elements. This paper proposes an efficient UFR monitoring system which provides accurate UFR positioning information with low-cost onboard elements; a small ARM module based on an embedded Linux operating system, a low-cost single frequency GPS receiver with a cheap patch antenna, and a versatile wireless network interface module. The ground monitoring system employs a dual frequency GPS receiver to generate exact UFR coordinates with cm-level accuracy. By processing the UFR measurements based on the Inverse RTK (Real Time Kinematic) method, the ground monitoring system determines the cm-level accurate coordinates of the UFR. The feasibility of the proposed UFR monitoring system was evaluated by three experiments in terms of data loss and accuracy.

Implementation of a bio-inspired two-mode structural health monitoring system

  • Lin, Tzu-Kang;Yu, Li-Chen;Ku, Chang-Hung;Chang, Kuo-Chun;Kiremidjian, Anne
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.119-137
    • /
    • 2011
  • A bio-inspired two-mode structural health monitoring (SHM) system based on the Na$\ddot{i}$ve Bayes (NB) classification method is discussed in this paper. To implement the molecular biology based Deoxyribonucleic acid (DNA) array concept in structural health monitoring, which has been demonstrated to be superior in disease detection, two types of array expression data have been proposed for the development of the SHM algorithm. For the micro-vibration mode, a two-tier auto-regression with exogenous (AR-ARX) process is used to extract the expression array from the recorded structural time history while an ARX process is applied for the analysis of the earthquake mode. The health condition of the structure is then determined using the NB classification method. In addition, the union concept in probability is used to improve the accuracy of the system. To verify the performance and reliability of the SHM algorithm, a downscaled eight-storey steel building located at the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark structure. The structural response from different damage levels and locations was collected and incorporated in the database to aid the structural health monitoring process. Preliminary verification has demonstrated that the structure health condition can be precisely detected by the proposed algorithm. To implement the developed SHM system in a practical application, a SHM prototype consisting of the input sensing module, the transmission module, and the SHM platform was developed. The vibration data were first measured by the deployed sensor, and subsequently the SHM mode corresponding to the desired excitation is chosen automatically to quickly evaluate the health condition of the structure. Test results from the ambient vibration and shaking table test showed that the condition and location of the benchmark structure damage can be successfully detected by the proposed SHM prototype system, and the information is instantaneously transmitted to a remote server to facilitate real-time monitoring. Implementing the bio-inspired two-mode SHM practically has been successfully demonstrated.

Implementation of Air Pollutant Monitoring System using UAV with Automatic Navigation Flight

  • Shin, Sang-Hoon;Park, Myeong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.77-84
    • /
    • 2022
  • In this paper, we propose a system for monitoring air pollutants such as fine dust using an unmanned aerial vehicle capable of autonomous navigation. The existing air quality management system used a method of collecting information through a fixed sensor box or through a measurement sensor of a drone using a control device. This has disadvantages in that additional procedures for data collection and transmission must be performed in a limited space and for monitoring. In this paper, to overcome this problem, a GPS module for location information and a PMS7003 module for fine dust measurement are embedded in an unmanned aerial vehicle capable of autonomous navigation through flight information designation, and the collected information is stored in the SD module, and after the flight is completed, press the transmit button. It configures a system of one-stop structure that is stored in a remote database through a smartphone app connected via Bluetooth. In addition, an HTML5-based web monitoring page for real-time monitoring is configured and provided to interested users. The results of this study can be utilized in an environmental monitoring system through an unmanned aerial vehicle, and in the future, various pollutants measuring sensors such as sulfur dioxide and carbon dioxide will be added to develop it into a total environmental control system.

Cable Tunnel Monitoring System by Wireless Sensor Network (무선센서 네트워크에 의한 지하 통신구 터널 모니터링 연구)

  • Kim, Hyung-Woo;Moon, Tae-Gyun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.549-552
    • /
    • 2008
  • In this study, we deployed the cable tunnel inspection and monitoring system by wireless sensor network. It is shown that the wireless sensor network which is composed of sensor, wireless communication module, and gateway can be applied to cable tunnel monitoring system. Sensors considered herein are flame detection sensor, flood detection sensor, intruder detection sensor, and temperature sensor, etc. It is also found that the wireless sensor network can deliver sensing data reliably by wireless sensing technology. The gateway system that can transmit sensed data to server by CDMA is developed. Monitoring system is constructed by web service technology, and it is observed that this system can monitor the present state of tunnel without difficulties. The system provides an alternative to inspecting and monitoring the tunnel efficiently where the conventional wired system is infeasible.

  • PDF

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF