• 제목/요약/키워드: monitoring integrity

검색결과 322건 처리시간 0.034초

CANDU형 원전 경년열화 감시시스템(Aging Monitor) 개발 (Development of CANDU Reactor Aging Monitor)

  • 김홍기;최영환;고한옥
    • 한국압력기기공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.13-19
    • /
    • 2009
  • As the operating time in nuclear power plants (NPPs) increases, the integrity of nuclear components may be continually degraded due to aging effects of systems, structures and components. Recently, a number of NPPs are being operated beyond their design life to produce more electricity without shutting down. The critical issue in extending a lifetime is to maintain the level of safety during the extended operation period while satisfying the international regulatory standards. Therefore, it is beneficial to build a monitoring system to measure an aging status. In this paper, the Aging Monitor (AM) based on lots of aging database obtained from the operating plants and research results on the aging effects was developed to monitor, manage and evaluate the aging phenomena systematically and effectively in NPPs. The AM for the CANDU is divided into 6 modules: (1) Aging Alarm/Coloring Monitor, (2) Aging Database, (3) Aging Document, (4) Real-time Integrity Monitor, (5) Surveillance and Inspection Management System, and (6) Continued Operation and Periodic Safety Review (PSR) Safety Evaluation. The proposed system is expected to provide the integrity assessment for the major mechanical components of an NPP under concurrent working environments.

  • PDF

KARI IMT 시스템의 GBAS 보정정보 검증시험 (Verification Test for GBAS Correction Information of KARI IMT)

  • 윤영선;임준후;조정호;허문범
    • 한국항공우주학회지
    • /
    • 제39권2호
    • /
    • pp.153-161
    • /
    • 2011
  • 한국항공우주연구원에서는 GBAS 기준국의 무결성 감시 알고리즘 개발을 위한 데이터 제공 및 시험을 위하여 무결성 감시 테스트베드를 구축하였다. 개발된 알고리즘의 정확한 구현 및 시험을 위해서는 기반이 되는 시설 및 소프트웨어의 기본 기능이 국제 표준에 부합하게 구현되어 있어야 하므로, 본 논문에서는 현재 구축된 테스트베드의 GBAS 기준국으로서의 기본 기능에 대한 검증시험을 수행한다. 이를 위해 국제적으로 신뢰받고 있는 프로그램인 PEGASUS와의 비교를 통하여 GBAS 보정 정보의 타당성을 확인하였으며, 이를 적용한 사용자 측면에서의 거리 영역 및 위치 영역에서의 데이터 분석을 통하여 시스템의 무결성 및 가용성 성능을 확인하였다.

Design of the Pseudolite Pulsing Scheme

  • Chang, Jae-Won;Cho, Deuk-Jae;Park, Chan-Sik;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.215-218
    • /
    • 2004
  • The pseudolites are ground-based transmitters that can be configured to emit GPS-like signals with the purpose of enhancing the GPS by providing increased accuracy, integrity, and availability. Although the use of the pseudolites offers many potentially significant benefits, a number of technical issues must also be addressed. One is the pseudolite signal power level which is related with near-far problem, and other issues include deployment requirements, signal data rate, signal integrity monitoring, and user antenna location and sensitivity. In order to solve the near-far problem, the frequency offset or the pulsing schemes is implemented in most the pseudolites. However, in the case of the previous pulsing scheme with the fixed code pattern, the near-far problem still remains. This paper aims to design a sequential pulsing scheme to avoid the near-far problem. A pulse mode pseudolite has less interference than the continuous mode.

  • PDF

한국형 가동헬기 임무탑재장비 요구항법성능 구현 (Required Navigation Performance Implementation of Mission Equipment Package for Korean Utility Helicopter)

  • 김성우;이병화;오우섭
    • 한국군사과학기술학회지
    • /
    • 제14권5호
    • /
    • pp.798-804
    • /
    • 2011
  • A number of navigation improvements are envisaged : Differential GPS - WAAS, LAAS, and Performance Based Navigation. The GPS receiver verifies the integrity(usability) of the signals received from the GPS constellation through a process called receiver autonomous integrity monitoring(RAIM) to determine if a satellite is providing corrupted information. This paper describe the RAIM function and Performance-Based Navigation implementation of Mission Equipment Package(MEP) for Korean Utility Helicopter.

무근 콘크리트에서 균열 발생원 탐사를 위한 AE 기법의 적용 (Application of Acoustic Emission Technique for Crack Source Location Search in Plain Concrete)

  • 한상훈;이웅종;조홍동;김동규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.793-798
    • /
    • 1999
  • This study was conducted to evaluate structural integrity and crack source location of plain concrete beams using acoustic emission. Three point bending tests were carried out plain concrete specimen under cyclic loadings. The variable is W/C of concrete. From the tests it was shown that a breakdown of the kaiser effect and high AE activities during unloading could be effective indices to estimate the level of deterioration in plain concrete structures. The time and location and propagation of crack could be easily determined by monitoring AE, which concludes that AE technique can be a very useful tool to evaluate structural integrity of concrete plain beams.

  • PDF

탄소섬유보강판으로 보강된 철근콘크리트보의 균열 발생원 탐사를 위한 Acoustic Emission의 적용 (The Application of Acoustic Emission to detect the Crack Source Location for RC Beams Strengthened With Carbon Fiber Reinforced Plates)

  • 한상훈;이웅종;조홍동;나승일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.423-428
    • /
    • 2000
  • This Study was conducted to evaluate structural integrity and crack source location of RC structures strengthened with Carbon Fiber Reinforced Plates using acoustic, Four pont bending tests were carried out RC reinforced with C.F.R.P for the several strengthening specimens, the process of fracture was monitored by Acoustic Emission and duration and energy in AE parameters were analyzed. The location and propagation of crack could be easily determined by monitoring AE, which concluded that AE technique could be a very useful tool to evaluate structural integrity of reinforced RC structure.

  • PDF

원자로냉각재계통 압력경계밸브 내부누설 평가 (Assessment of Internal Leak on RCS Pressure Boundary Valves)

  • 박준현;문호림;정일석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.322-327
    • /
    • 2001
  • The internal leaks of RCS pressure boundary valves may cause thermal fatigue crack because of the TASCS in RCS branch line. After experienced unisolable piping failures in several PWR plants, many studies have peformed to understand these phenomena and various methods were applied to ensure the structural integrity of piping. In this paper, the cause of unisolable piping failures and the alternatives to prevent recurrence of failure were reviewed. Also, the severity of piping failure including susceptibility of valve leaks was evaluated for the Westinghouse 2-loop plant. The length of turbulent penetration on RHR inlet piping was measured and, thermal fluid analysis and fatigue analysis was performed for this piping. As a means of ensuring the structural integrity, temperature monitoring and specialized UT and other alternatives were compared for the further application.

  • PDF

커널 기반 가상머신을 이용한 시스템 무결성 모니터링 시스템 (System Integrity Monitoring System using Kernel-based Virtual Machine)

  • 남현우;박능수
    • 정보처리학회논문지C
    • /
    • 제18C권3호
    • /
    • pp.157-166
    • /
    • 2011
  • 가상화 계층은 커널 보다 높은 권한 계층에서 수행되어 운영체제가 사용하고 있는 자원 정보를 모니터링 하는데 적합하다. 하지만 기존 가상화 기반 모니터링 시스템은 CPU나 메모리 사용률과 같은 기초적인 정보만을 제공하고 있다. 본 논문에서 메모리, 레지스터 GDT, IDT 그리고 시스템 콜과 같은 동적인 시스템 커널 객체를 모니터링하기 위하여 전가상화 방식의 모니터링 시스템을 제안한다. 모니터링 시스템을 검증하기 위해 커널의 수정 없이 바로 리눅스 커널에 적용된 전가상화 방식의 KVM을 기반으로 시스템을 구현하였다. 구현된 시스템은 KVM 내부 객체에 접근하기 위한 KvmAccess 모듈, 그리고 가상머신 모니터링 결과를 외부 모듈에서도 사용할 수 있도록 API를 제공하였다. 구현된 모니터링 시스템의 성능을 측정한 결과 1초 주기로 시스템을 모니터링을 하더라도 0.37% 정도의 CPU 점유율을 차지하여 그 성능 부하가 아주 작았다.

다종 센서간 위상 차이를 이용한 충격 위치추정 기법 (Source localization technique for metallic impact source by using phase delay between different type sensors)

  • 최경식;최영철;박진호;김환우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.687-692
    • /
    • 2008
  • In a nuclear power plant, loose part monitoring and its diagnostic technique is one of the major issues for ensuring the structural integrity of the reactor system. Typically, accelerometers are mounted on the surface of a reactor vessel to localize impact location caused by the impact of metallic substances on the reactor system. However, in some cases, the number of the accelerometers is not enough to estimate the impact location precisely. In such a case, one of alternative plan is to utilize another type sensors that can measure the vibration of the reactor structure even though the measuring frequency ranges are different from each others. The AE sensors installed on the reactor structure can be utilized as additional sensors for loose part monitoring. In this paper, we proposed a new method to estimate impact location by using both accelerometer signal and AE signal, simultaneously. The feasibility of the proposed method is verified by an experiment. The experimental results demonstrate that we can enhance the reliability and precision of the loose part monitoring.

  • PDF

Two-dimensional water seepage monitoring in concrete structures using smart aggregates

  • Zou, Dujian;Li, Weijie;Liu, Tiejun;Teng, Jun
    • Structural Monitoring and Maintenance
    • /
    • 제5권2호
    • /
    • pp.313-323
    • /
    • 2018
  • The presence of water inside concrete structures is an essential condition for the deterioration of the structures. The free water in the concrete pores and micro-cracks is the culprit for the durability related problems, such as alkali-aggregate reaction, carbonation, freeze-thaw damage, and corrosion of steel reinforcement. To ensure the integrity and safe operation of the concrete structures, it is very important to monitor water seepage inside the concrete. This paper presents the experimental investigation of water seepage monitoring in a concrete slab using piezoelectric-based smart aggregates. In the experimental setup, an $800mm{\times}800mm{\times}100mm$ concrete slab was fabricated with 15 SAs distributed inside the slab. The water seepage process was monitored through interrogating the SA pairs. In each SA pair, one SA was used as actuator to emit harmonic sine wave, and the other was used as sensor to receive the transmitted stress wave. The amplitudes of the received signals were able to indicate the water seepage process inside the concrete slab.