• Title/Summary/Keyword: monitoring device

Search Result 1,402, Processing Time 0.031 seconds

Development of Moving and Attaching Diagnosis Device Using IoT (IoT 활용 이동착탈식 열화 진단 장치 개발)

  • Ka, Chool-Hyun;Lee, Dong-Gyu;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.596-601
    • /
    • 2017
  • The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.

System Hardening and Security Monitoring for IoT Devices to Mitigate IoT Security Vulnerabilities and Threats

  • Choi, Seul-Ki;Yang, Chung-Huang;Kwak, Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.2
    • /
    • pp.906-918
    • /
    • 2018
  • The advent of the Internet of Things (IoT) technology, which brings many benefits to our lives, has resulted in numerous IoT devices in many parts of our living environment. However, to adapt to the rapid changes in the IoT market, numerous IoT devices were widely deployed without implementing security by design at the time of development. As a result, malicious attackers have targeted IoT devices, and IoT devices lacking security features have been compromised by attackers, resulting in many security incidents. In particular, an attacker can take control of an IoT device, such as Mirai Botnet, that has insufficient security features. The IoT device can be used to paralyze numerous websites by performing a DDoS attack against a DNS service provider. Therefore, this study proposes a scheme to minimize security vulnerabilities and threats in IoT devices to improve the security of the IoT service environment.

Realization of Communication and Sensor Signal Processing Technique for Condition Monitoring of Check Valve (Check Valve 상태감시를 위한 통신 및 센서신호처리 기능 구현)

  • Jeon, Jeong-Seop;Jo, Jae-Geun;Kim, Jeong-Su;Yu, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.223-226
    • /
    • 2003
  • This paper presents a realization of sensor signal processing(noise filtering) and Fieldbus based communication for condition monitoring of check valve. we first acquired the AE(Acoustic Emission) sensor data at the KAERI check valve test loop, and their frequencies were analyzed to find the informative band. To reject background noises, bandpass filters have been designed. Also, to send the processed data to a remote site, wired communication facility has been realized via DeviceNet.

  • PDF

The Correlation between the Ultrasonic Backscattered Energy and the Applied Stress in Al material (Al재료(材料)에서 Ultrasonic Backscattered Energy와 Stress와의 상호관계(相互關係))

  • Park, J.H.;Park, C.S.;Lim, H.T.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.1
    • /
    • pp.32-41
    • /
    • 1987
  • As a new device of stress monitoring method, ultrasonic backscattering method has been used to aluminium samples with various grain sizes at rayleigh critical angle in order to observe the relationships between applied stress and ultrasonic backscattered energy. It was found that the ultrasonic backscattered energy was observed to decrease as the grain size increased at the given applied stress. At the same grain size, the ule ultrasonic backscattered energy increased with increasing the applies stress. Through this study, we provided some possibility to evaluate stresses in materials under loads nondestructively, and this method is expected to be used as a new stress monitoring device.

  • PDF

Study on the MQTT protocol design for the application of the real-time HVAC System

  • Jung, Hun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, the existing domestic HVAC systems, devices TCP / IP does not support the most, thereby, not performed remote management, it is necessary to regularly field service, inefficiency and cost bring a burden. This is through a comparison of the IoT-based primary, real-time protocol of what has become a hot topic recently, to be able to control and real-time monitoring through the CCU device in the HVAC system. Compare for this Internet of Things device for real-time monitoring and control of the XMPP, CoAP, MQTT main real-time protocol is used on. Finally, flexibility, light weight, based on MQTT a two-way messaging protocols with reliable message delivery, implements the protocol on the real-time HVAC system in the cloud platform.

Research of operators and patients exposed to electromagnetic field in the hospital (병원에서의 환자, 의료진의 전자파 노출 실태 조사)

  • Ji, Hyo-Chul;Hong, Hyun-Ki;Kim, Sung-Woo;Lee, Ju-Hyung;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.70-72
    • /
    • 2007
  • In this study, electromagnetic fields emitted from the various environment in the hospital were measured. Measurement spot was patients' head. To monitor how much magnetic fields are emitting from operation room, monitoring device was attached to 19 anesthesiologist and monitoring lasted 8 hours. We also took a measurement from various medical devices. Devices include ESWL, PET, MRI, CT, Gamma knife, X-ray, Angiogram, Echocardiogram, Upper GI and Linear Accelerator. Electromagnetic fields were measured from 10 spots from each of 5 patient waiting room. As a results, there were no places showing risk of high exposure. All the measurement values were below the reference levels for general public exposure to time varying electric and magnetic fields which is issued by ICNIRP.

  • PDF

Analysis & Design of Cooling System for Electric Propulsion System (전기추진시스템의 냉각시스템에 관한 분석 및 설계)

  • Yu, Byong-Rang;Oh, Jin-Seok;Jin, Sun-Ho;Lim, Myoung-Kyu;Kwak, Jun-Ho;Jo, Kwan-Jun;Kim, Jang-Mok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1113-1119
    • /
    • 2005
  • The power electric system is one of the most concerning factor for the reliability of the electric propulsion ship. operation in higher temperature decreases the device's reliability and power efficiency. the management of power loss and temperature of switching devices is indispensable for the reliability fo the power electric system. In this paper, IGBT chip of the switching devices is modeled and MIIR(Motor with Inverter Internal to Rotor)type of the propulsion motors is used. these parts interact with each other to calculate the loss and temperature of device. calculated Results is modeled and designed of the control and monitoring system for the electric propulsion system.

  • PDF

An Experimental Study on the Light Transmission Characteristics with Oil Contamination (윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • Changes in light transmission characteristics caused by various types of oil contaminations were experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon duct, two kinds of solutions and grease were used for the test contaminants in this work. Light intensity of the transmitted light was measured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and poly-meric fibers in terms of the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change in lubricating oils.

Analysis & Design of Cooling System for Electric Propulsion System (전기 추진 시스템의 냉각시스템에 관한 분석 및 설계)

  • Oh, Jin-Seok;Jo, Kwan-Jun;Kwak, Jun-Ho;Lee, Ji-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.596-602
    • /
    • 2008
  • The cooling system is one of the most concerning factor for the reliability of the electric propulsion ship. Generally, a drive system operation in higher temperature decreases the device's reliability and power efficiency. The management of power loss and temperature of switching devices is indispensable for the reliability of the power electric system. In this paper, the switching devices are molded by IGBT, and the propulsion system is consisted of MIIR(Motor with Inverter Internal to Rotor). The system composition interacts with each other to calculate the loss and temperature of device. The calculation result is used for modeling and designing of the control and monitoring system for the electric propulsion system.

The Field Test of Heat Pump Cooling & Heating System using the water-purifying device (수도시설을 이용한 지열냉난방시스템의 실증연구)

  • Hwang, Ki-Sup;Jung, Woo-Sung;Ahn, Young-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.629-634
    • /
    • 2007
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, field test of facility for using the geothermal energy source from water-purifying device was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connecting a heat pump system into the existing pumping well in site of water-purifying in Cheongju. One set of monitoring results during summer was presented and analyzed.

  • PDF