• Title/Summary/Keyword: monitoring area

Search Result 3,378, Processing Time 0.029 seconds

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area on Severe Unbalanced Pressure Condition (편토압이 심한 도심지 대심도 암반굴착공사에서의 계측사례)

  • Kim, Tae-Seob;Kim, Woong-Kyu;Jung, Chang-Won;Han, Chul-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1259-1267
    • /
    • 2008
  • One of the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway is displacement control of earth retaining wall. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained one of deep urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This study was researched in restricted one case site, so it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

APPLICATION OF SATELLITE IMAGERY FOR DROUGHTS MONITORING IN LARGE AREA

  • Shin Sha-Chul;Jeong Soo;Kim Kyung-Tak;Kim Joo-Hun;Park Jung-Sool
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.398-401
    • /
    • 2005
  • Droughts have been an important factor in disaster management in Korea because she has been grouped into nations of lack of water. Satellite imagery can be applied to droughts monitoring because it can afford periodic data for large area for long time. This study aims to develop a method to analyze droughts in large area using satellite imagery. We estimated evapotranspiration in large area using NDVI data acquired from satellite imagery. For satellite imagery, we dealt with MODIS data operated by NASA. As the result of this study, we improved the usability of satellite imagery, especially in drought analysis.

  • PDF

Real Time Wide Area Voltage Stability Index in the Korean Metropolitan Area

  • Han, Sang-Wook;Lee, Byong-Jun;Kim, Sang-Tae;Moon, Young-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.451-456
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability has become one of the achievements we can obtain from PMUs. It is very important to select the most appropriate method for the Korea Electric Power Corporation (KEPCO) system since there are many voltage stability indices. In this paper, we propose an advanced WAVI (Wide Area Voltage Stability) that is well suited for the purposes of monitoring the dynamic voltage stability of KEPCO's PMU installation plan. The salient features of the proposed index are: i) it uses only PMU measurements without coupling with EMS data; ii) it is computationally unburdened and can be applied to real-time situations. The proposed index is applied to the KEPCO test system and the results show that it successfully predicts voltage instability through comparative studies.

Design & Development of System Architecture for Wide Area Defense System (광역정전 Defense를 위한 System Architecture 설계 및 개발)

  • Kim, S.-Tae;Lee, Jeong-Hyun;Kim, Ji-Young;Lee, Dong-Chul;Moon, Young-Hwan;Kim, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.165-166
    • /
    • 2006
  • Recently, after Wide Area Outage of the North-Eastern United States occurred, many countries started to be concerned about WAMS (Wide Area Monitoring System), and Korean power system also experienced Wide Area outage according to typhoon Mae-Mi, and Haenam-Jeju HVDC line fault. Since it is too difficult to detect a symptom based on SCADA or EMS, a defense system of electric power infrastructure has required. In this research, the designed and developed system processes the time synchronized real time power system information based on GPS and shows the 2D/3D monitoring viewer using the phasor data and the results of three algorithms.

  • PDF

A Study for Spatial Distribution of Principal Pollutants in Daegu Area Using Air Pollution Monitoring Network Data (도시대기측정망 자료를 이용한 대구지역 대기오염물질의 공간분포에 관한 연구)

  • Ju, Jae-Hee;Hwang, In-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.545-557
    • /
    • 2011
  • The objective of this study was to estimate the trends of each pollutant using the air pollution monitoring networks data from January 2005 to December 2008 in Daegu area. Also, the spatial characteristics of each pollutant were determined using the Pearson correlation coefficients and COD (coefficients of divergence). In this study, the trends of hourly, monthly, seasonal, and total average concentrations of each pollutant for the 10 sites were analyzed. The Ihyeon site showed highest concentration for the $SO_2$, $NO_2$, and PM10}. In the case of $O_3$, the Jisan site showed highest concentration among the other sites. Also, industrial area presented highest concentration for the $SO_2$, CO, and PM10. On the other hand, $NO_2$ showed highest in commercial area. The IDW (inverse distance weighting) method was used to estimate characteristics of spatial distribution. The results provide identify spatial distribution for each pollutant. Also, the Pearson correlation coefficients and COD values provide spatial variability among the monitoring sites. The COD of each pollutant showed very low values for all of the sites pairs. On the other hand, the Pearson correlation coefficients showed high values for all of the sites pairs. Finally, analysis of spatial variability can be used to characterize the spatial uniformity and similarity of concentrations from each pollutant.

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

A Study on Local Area Weather Condition Monitoring System in WSN and CDMA (무선센서네트워크와 CDMA망을 이용한 국지적 기상모니터링 시스템)

  • Chung, Wan-Young;Jung, Sang-Joong;Kim, Jong-Jin;Kwon, Tae-Ha
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1713-1720
    • /
    • 2009
  • An local area weather condition monitoring system to minimize many disasters from the sudden change of weather condition in local and mountain ales is proposed. Firstly, the comparison of present state of the related monitoring systems and the possibility of realization with some merits are investigated. Moreover, this paper present direction of local area weather condition monitoring system based on integration of wireless sensor network and CDMA network following some case study. The sensor node for wireless sensor network and an interface dongle are fabricated for the system. The stand-alone software in cellular phone is also developed. Through the efficient integration of both networks, the measured weather condition data from sensors can be transmitted to the server or mobile to monitor with high reliability. The proposed monitoring system will guide new type of project in wireless sensor network and support alarm service of the sudden change of weather condition to mobile user from central official regulations.

Active monitoring of pipeline tapered thread connection based on time reversal using piezoceramic transducers

  • Hong, Xiaobin;Song, Gangbing;Ruan, Jiaobiao;Zhang, Zhimin;Wu, Sidong;Liu, Guixiong
    • Smart Structures and Systems
    • /
    • v.18 no.4
    • /
    • pp.643-662
    • /
    • 2016
  • The monitoring of structural integrity of pipeline tapered thread connections is of great significance in terms of safe operation in the industry. In order to detect effectively the loosening degree of tapered thread connection, an active sensing method using piezoceramic transducers was developed based on time reversal technique in this paper. As the piezoeramic transducers can be either as actuators or sensors to generate or detect stress waves, the energy transmission for tapered thread connection was analyzed. Subsequently, the detection principle for tapered thread connection based on time reversal was introduced. Finally, the inherent relationship between the contact area and tightness degree of tapered thread connection for the pipe structural model was investigated. Seven different contact area scenarios were tested. Each scenario was created by loosening connectors ranging from 3 turns to 4.5 turns in the right tapered threads when the contact area in the left tapered threads were 4.5 turns. The experiments were separately conducted with a highly noisy environment and various excitation signal amplitudes. The results show the focused peaks based on time reversal have the monotonously rising trend with the increase of the contact areas of tapered threads within an acceptable monitoring resolution for metal pipes. Compared with the energy method, the proposed time reversal based method to monitor tapered threads loosening demonstrates to be more robust in rejecting noise in Structural Health Monitoring (SHM) applications.

Assessment of PM-10 Monitoring Stations in Daegu using GIS Interpolation (공간 보간법을 이용한 도시지역 미세먼지 측정소의 배치 적절성 평가)

  • Kim, Hyo-Jeong;Jo, Wan-Kuen
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.2
    • /
    • pp.3-13
    • /
    • 2012
  • This study evaluated the feasibility of the location for PM-10 Monitoring Stations utilizing through GIS analysis. In addition, optimal sites were investigated to properly manage PM-10 which are closely related with public health. There are 11 PM-10 monitoring stations in Daegu area and the PM-10 data monitored at these stations are utilized to understand the overall status of PM-10 pollution. However, there are contrastive issues on the locations of current monitoring stations. Thus, this study prepared the map of PM-10 concentrations in Daegu area using IDW and Kriging techniques. Furthermore, average PM-10 concentrations were calculated using zonal statistical methods according to legal divisions and then, the current monitoring stations were evaluated whether their location is appropriate or not for PM-10 pollution distribution. It was found that, on the basis of yearly, seasonal and daily concentration analysis, the location of current PM-10 monitoring stations were not appropriate, particularly as they could not represent regional PM-10 pollution characteristics. In order to supplement this deficiency, seven sites(Namsandong, Namildong, Dongildong, Buksungro 1, Jongro 1, Hyangchondong and Haejeondong) commonly selected from each analytical step are suggested as additional PM-10 monitoring sites. It is further suggested that this kind of scientific evaluation for the location of PM-10 monitoring stations are needed in order to properly manage public heath in other cities as well as Daegu area.