• Title/Summary/Keyword: monitor

Search Result 7,367, Processing Time 0.041 seconds

Forecasting the Future of the Desktop Monitor Market

  • Young, Ross
    • The Magazine of the IEIE
    • /
    • v.28 no.4
    • /
    • pp.89-96
    • /
    • 2001
  • The LCD monitor market enjoyed rapid growth in 1999 but only experienced modest growth in 2000. It is now poised for rapid growth from 2001 to 2005 as prices and costs decline. Price reductions will enable LCD monitors to move beyond limited vertical markets and extend into the broader consumer markets. This article will examine the future outlook for LCD monitors and provide a growth forecast.

  • PDF

The Implementation of Real-time Performance Monitor for Multi-thread Application (멀티스레드 어플리케이션을 위한 실시간 성능모니터의 구현)

  • Kim, Jin-Hyuk;Shin, Kwang-Sik;Yoon, Wan-Oh;Lee, Chang-Ho;Choi, Sang-Bang
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.3
    • /
    • pp.82-90
    • /
    • 2011
  • Multi-core system is becoming more general with development of microprocessors. Due to this change in performance improvement paradigm, switching conventional single thread applications with multi thread applications. Performance monitoring tools are used to optimize application performance because of complexity in development of multi thread applications. Conventional performance monitoring tools are focused on performance itself rather than user friendliness or real-time support. Real-time performance monitor identify the problem while multi-threaded applications should be performed as well as check real-time operating status of the application. So it can be used as an effective tool compared to non-real-time performance monitor that only with simple performance indicators to find the cause of the problem. In this paper, we propose RMPM(Real-time Multi-core Performance Monitor) which is real-time performance monitoring tool for multi-core system. Observation period is optimized by comparing relation between overhead due to performance evaluation period and accuracy. Our performance monitor shows not only amount of CPU usage of whole system, memory usage, network usage but also aspect of overhead distribution per thread of an application.

The Development of Pc Based EGG-NIBP Patient Monitor (PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.461-469
    • /
    • 1999
  • In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.

  • PDF

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

Neutron fluence measurement at HANARO using fluence monitor method (Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정)

  • Lee, Seung-Kyu;Jo, Kwang-Ho;Choo, Kee-Nam;Park, Jin-Suk;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.200-208
    • /
    • 2011
  • The neutron fluence measurement and evaluation technology is very important for material irradiation test. The most essential technology in this study is the neutron irradiation evaluation method using a fluence monitor. The fluence monitors were fabricated with metal wires of the purity ${\geq}$ 99.9%, whose dimensions were 0.1mm diameter, about 3 mm length, and around 150-200 ${\mu}g$ mass range. Three wire samples (Fe, Ni, Ti) were prepared for one irradiation aluminum capsule. Five capsules were irradiated in the OR5 hole of the HANARO reactor at 30 MW power for about 25 days. After irradiation tests, radiation activities were measured with the high purity germanium (HPGe) detector. The reaction rates were calculated by using the measured radiation activity data, and then neutron fluence were obtained from the reaction rates and the weighted neutron cross section with calculated neutron spectrum at the fluence monitor position.

Observation of Periodic and Transient Cosmic Ray Flux Variations by the Daejeon Neutron Monitor and the Seoul muon Detector

  • Oh, Suyeon;Kang, Jeongsoo
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.175-178
    • /
    • 2013
  • Recently, two instruments of cosmic ray are operating in South Korea. One is Seoul muon detector after October 1999 and the other is Daejeon neutron monitor (Kang et al. 2012) after October 2011. The former consists of four small plastic scintillators and the latter is the standard 18 NM 64 type. In this report, we introduce the characteristics of both instruments. We also analyze the flux variations of cosmic ray such as diurnal variation and Forbush decrease. As the result, the muon flux shows the typical seasonal and diurnal variations. The neutron flux also shows the diurnal variation. The phase which shows the maximum flux in the diurnal variation is around 13-14 local time. We found a Forbush decrease on 7 March 2012 by both instruments. It is also identified by Nagoya multi-direction muon telescope and Oulu neutron monitor. The observation of cosmic ray at Jangbogo station as well as in Korean peninsula can support the important information on space weather in local area. It can also enhance the status of Korea in the international community of cosmic ray experiments.

A Study on The Reduction of Cycle Time in Injection Molding Process of The Monitor Backcover (Monitor Backcover의 사이클 타임 단축에 관한 연구)

  • Yoon K. H.;Kim J. K.
    • Transactions of Materials Processing
    • /
    • v.14 no.4 s.76
    • /
    • pp.368-374
    • /
    • 2005
  • In the present study we used a diagrammatic analysis of 6 sigma quality control and Taguchi method for injection molding of monitor back-cover, evaluated the influence on the cycle time with part design, mold design, molding process and standardization activity involving design and molding, adopted analysis of sensitivity and effective factors of the part design and molding process conditions for productivity, identified main design molding factors. The contributing factors for the final cycle time could be enumerated as follows; the thickness of hot spot, main nominal part thickness, coolant inlet temperature, melt temperature and cooling line layout, etc.. As a first step, all the critical factors of design process applied to the current monitor housing were investigated through 6 sigma process. Thereafter, the optimal and better critical factors found in the first step were applied to new product design to prove that our process was correct. The Moldflow was used for injection molding simulation, and Minitab software for the statistical analysis, respectively. Finally, the productivity of new design was increased about 33 percents for our specific case.

Design of the backlight inverter for multi-lamp driving

  • Han Jae Hyun;Lim Young Cheol;Yang Seung Hak;Kweon Gie Hyoun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.80-83
    • /
    • 2001
  • As a LCD monitor is larger and thinner, a Cold Cathode Fluorescent Lamp (CCFL) for backlight in LCD monitor gradually becomes longer and thinner. The backlight of a large LCD monitor, however, has a limitation in its brightness. In this study, a parallel multi-lamp is used in order to supply enough brightness. Though the CCFLs are made through a detail and equal manufacturing process, they don't have exactly the same features individually in their brightness, frequency, voltage and current. Consequently, it is difficult to have equal brightness at an early lighting condition or during lighting time. In this paper, a parallel multi-lamp which can have the same output under the same condition is designed. For this, 18 inch LCD monitor with four lamps is used. An inverter for multi-lamp driving is also used in this study. The newly designed inverter shows more than $90\%$ efficiency in its brightness input and output. Besides, it is also available for a multi-drive of other lamps.

  • PDF

Design and Implementation of a Monitor Checking the Execution Time of Real-time Object-oriented Programs (실시간 객체지향 프로그램의 실행시간을 감시하는 모니터의 설계 및 구현)

  • Min, Byoung-Joon;Choi, Jae-Young;Kim, Jung-Guk;Kim, Moon-Hae
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.12
    • /
    • pp.3804-3814
    • /
    • 2000
  • This paper presents an efficient implementation of a run-time monitor which checks the satisfaction of the timing constraints of real-time object-oriented programs based on a real-time object model called TMO(Time-triggered Messagedtriggered Object). An execution environment of TMO programs on Windows as, WTMOS(Windows TMO System) has been utilized for the implementation and an experimental application for thermostatic control has been developed to analyze the performance of the run-time monitor. We suggest a methodology for application programmers to specify the target methods with the monitoring conditions and an implementation technique which incurs the small cost by effectively distributing the functions of the monitor into the WTMOS and a TMO object.

  • PDF

A Study on Occupational Nursing Services in Small Sacle Industry with Reference to Phenomenological Study (현상학적 방법에 의한 소규모 사업장 산업간호활동에 관한 연구)

  • Jung Moon-Hee;Cho Chung-Min;Lee Soo-Yeon
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.13-22
    • /
    • 1998
  • This study was conducted to find qualitative approaches to occupational reference to group health practices. In-depth interviewing was done on 8 subjects health monitor members, owners and occupational nurses, respectively). The major findings were as follows; 1. Visiting health management Useful services were 'health counseling', 'medical examination', 'providing informations about managing diseases', 'agency business in relation to Labour Ministry' and 'giving a recognition about occupational health service to owners'. Insufficiencies were 'lack of treatment service after medical examination' and 'lack of follow up services constantly'. 2. Occupational nursing service Useful services were 'providing health information' and 'counselling about health'. Major contents of occupational nursing services were 'management of occupational and adult diseases' and 'explanation of the results after medical examination'. Insufficiencies were 'deficiency of the place where group health education could be performed', 'lack of additional or closer examinations needed in counselling' and 'discontinuous selection of additional or more exact examinations'. 3. Health monitor members Health monitor members in industries were classified into two. Some were selected by owners and the others were selected simply by considering their administrative abilities such as proficient management of documents. Their major tasks were to connect workers with occupational health management agencies. This study suggests that programs should be developed which enable health monitor members to cooperate with occupational nurses.

  • PDF