• Title/Summary/Keyword: monitering

Search Result 229, Processing Time 0.032 seconds

A Study on IoT Monitering Technology of Power Converter for E-Mobility (E-Mobility용 전력변환기의 IoT 모니터링 기술에 대한 연구)

  • Lee, In-Seok;Lee, Ju;Kang, Ja-Yoon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.39-44
    • /
    • 2018
  • In this paper, we propose a monitoring method of smartphone to integrate IoT technology to monitor the state of the vehicle for fault diagnosis of E-Mobility power converter. In China, EV regulations are being implemented to promote technological development and market changes in electric vehicles. To meet this trend, E-Mobility should study suitable monitoring technology. The OBD-II method used in existing automobiles is a wired / wireless communication method. In order to apply it to E-Mobility, additional interface and communication link are required. In this paper, we propose a technology to monitor the status information of power converter for E-Mobility by combining existing technology with IoT. This technology simplifies the existing network protocol and hardware interface, and confirms that the E-Mobility power converter and smartphone can be interworked for easy user monitoring. And we have done research to make high value product design from the aspect of function.

The Web Viewer System Development of Real-Time Patient Monitering using HL7(Healthy Level Seven) Protocol (HL7(Healthy Level Seven) 프로토콜을 이용한 실시간 환자 모니터링 웹 뷰어시스템 개발)

  • Kim, Gwang-Jun;Lim, Se-Jung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.546-555
    • /
    • 2009
  • HL7 is well-known standard protocol for text data generated in hospital information systems. Vital sign information web viewer systems is also the standard protocol for medical image and transfer. In this paper, we have to design to obtain useful vital sign information, which is generated at data receiver modulor of HIS, that is offered by the central monitor. Vital sign informations of central monitor is composed of the row data of several bedsite patient monitors. We are willing to maintain vital sign information of real time and continuity that is generated from the bedsite patient monitor. It is able to apply to remote medical examination and treatment. we proposed integration method between vital sign database systems and hospital information systems. Through the proper exchange and management of patient vital sign information, real time vital sign information management will offer better workflow to all hospital employee.

Implementation of the Disaster Monitering System with PLC/CDMA Environments (PLC/CDMA 환경에서의 재난 감시 시스템 구현)

  • Park, Sang-Hwan;Kim, In-Min;Yoon, Seon-Tae;Park, Ki-Won;Go, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.824-830
    • /
    • 2010
  • PLC_Zigbee system, implemented in a previous study, uses ZigBee Node based on PLC (Power Line Communication). The weak point of the system is that the long distance powerline communication and PLC is impossible to use in the areas where the powerline is not installed. In this paper, we added CDMA (Code Division Multiple Access) module using a data transfer method of SMS (Short Message Service) and XBee of WSN (Wireless Sensor Network) module to the previous system, and got around the restriction of place and environment of PLC system through the interfacing of each communication media. We, thus, implemented a wide range of real monitoring system.

Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry (전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구)

  • Kim, ByeongMan;Lee, KilSong;Yang, YeonWon;Shin, HyunWoo;Kim, EuiHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF

SE Appication of Smart UAV Development Program (스마트 무인기 개발프로그램의 시스템엔지니어링의 적용)

  • Lee, Jeong-Jin;Kim, Jae-Mu;Im, Cheol-Ho
    • 시스템엔지니어링워크숍
    • /
    • s.4
    • /
    • pp.108-112
    • /
    • 2004
  • The Smart UAV Program was motivated by a huge potential market, a various application and future core technologies. The Smart UAV system is defined as the advanced air vehicle with the smart technology such as collision awareness and avoidance, healthy monitering and self-recovering, intelligent active control. Due to the broad interest by government, industry and academia, Smart UAV development center and government steering committee were established. The organization of Smart UAV program consists of domestic/international companies and academia. in this paper, the process and application of system engineering was introduced for Smart UAV development program.

  • PDF

Development of the Noncontact Vibrometer for the Monitering System of Infrastructures (시설물 모니터링을 위한 비접촉식 진동측정시스템의 개발)

  • Jeong, Yo-Chan;Kwark, Jong-Won;Choi, Eun-Seok;Chin, Won-Jong;Lee, Jung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.563-566
    • /
    • 2005
  • This study deals with the development of noncontact vibration measuring system for monitoring the safety of structures as bridges, buildings, stadiums, tall chimneys, and dams where vibration measurements are very difficult because of various restrictions. Final object is to develope the system and be commercial by theoretical and experimental studies using IT technology for three years.

  • PDF

Application of Hydrological Monitoring System for Urban Flood Disaster Prevention (도시홍수방재를 위한 수문모니터링시스템의 적용)

  • Seo, Kyu-Woo;Na, Hyun-Woo;Kim, Nam-Gil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1209-1213
    • /
    • 2005
  • It reflects well feature of slope that is characteristic of city river basin of Pusan local. Process various hydrological datas and basin details datas which is collected through basin basis data. weather satellite equipment(EMS-DEU) and automatic water level equipment(AWS-DEU) and use as basin input data of ILLUDAS model, SWMM model and HEC-HMS model In order to examine outflow feature of experiment basin and then use in reservoir design of experiment basin through calibration and verification about HEC-HMS model. Inserted design rainfall for 30 years that is design criteria of creek into HEC-HMS model and then calculated design floods according to change aspect of the impermeable rate. Capacity of reservoir was determined on the outflow mass curve. Designed imagination reservoir(volume $54,000m^3$) at last outlet upper stream of experiment basin, after designing reservoir. It could be confirmed that the peak flow was reduced resulting from examining outflow aspect. Designing reservoir must decrease outflow of urban areas.

  • PDF

A study on Compare Characteristics of Nonpoint Source in Storm-water versus Steepness of Field Slope (밭경사에 따른 강우유출수 내의 비점오염물질 특성 비교 분석)

  • Kim, Gi-Cheol;Choe, Yong-Hun;Won, Cheol-Hui;Choe, Jung-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1093-1102
    • /
    • 2009
  • This study was focused on analyse Nonpoint source characteristics from Flat slope field and Steep slope field. We performed Storm-water monitering for obtain flow data and concentration data. Totally, eleven times Event was occurred. We calculated EMC(Event Mean Concentration) and Pollutants Loads using data we obtained. As a result, steep slope field has more discharge than flat field. SS value, one of the water quality contents, has largest variation and T-N has least variation. There is runoff differences even though events has same rainfall. We assume that not only amount of Rainfall, but also Rainfall Duration Times, Intensity, Number of Previous Non-precipitation days can affect to Run-off.

  • PDF

A monitering reference model construction of MOP foundation (MOP 기반 모니터링 참조 모델 구축)

  • Oh, Jeong-Jin;Cho, Sang-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2009.01a
    • /
    • pp.129-134
    • /
    • 2009
  • 본 연구에서는 모니터링 정보의 생성, 처리, 분산 및 표현에 수반되는 사양을 정형화된 주석으로 표현하여 구현이 함께 이루어질 수 있는 하나의 자동 코드 생성 알고리즘을 제안하는데 있다. 일반적인 패러다임은 언어 및 사양 독립적이지만, 제안되는 패러다임은 모니터링 지향 프로그래밍 영역에 속하는 것으로 하나의 프로타입 형태의 모니터링 지향 환경이 구현되고 제안된다. 입력으로 하나의 공식을 취하는 프로그램을 제공하는 방식으로 모니터링 지향 프로그래밍 환경에 대한 새로운 로직을 추가하고 미리 정의된 서식으로 출력이 이루어지도록 하는데 있다.

  • PDF

A Design of DC-MOTOR Realtime Monitering System in gas Control for Variable and Controllable (원격제어가 가능한 Gas 조절용 DC-Motor의 실시간 모니터링 시스템 구현)

  • Cho, Hyun-Seob;Min, Jin-Kyoung;Roh, Yong-Gi;Jung, Byung-Jo;Jang, Sung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1945-1946
    • /
    • 2006
  • 본 논문에서는 단결정($Al_2O_3$) 성장을 DC-Motor로 제어하여 양질의 결정을 얻도록 하는 자동 가스 조절용 DC-Motor의 운영 시스템과 실시간 모니터링 시스템을 구현 하였다.

  • PDF