• Title/Summary/Keyword: molecular sieve 5A

Search Result 51, Processing Time 0.027 seconds

A Study on the Separation of n-Hexane by Molecular Sieve 5A and the Purification for HPLC use (분자체 5A를 이용한 n-헥산의 분리와 HPLC급으로의 정제에 관한 연구)

  • Choi, Beom Suk;Kim, Young Man;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 1993
  • Technical grade n-hexane whose purity is 54% has been purified for HPLC use. Methylcyclopentane, 2-methylpentane, and 3-methylpentane which are hardly isolated by fractional distillation were separated by the liquid-solid chromatography using molecular sieve 5A. UV and fluorescence impurities whose contents are critically regulated for HPLC solvent were removed by the adsorptive separation with alumina and silica gel. The present method also reduced the impurities of color(APHA), acidity, water, residue after evaporation, sulfur, and thiophene content, and the impurity contents were well within the specifications of HPLC solvent.

  • PDF

A Facile Synthesis of SAPO-34 Molecular Sieves with Microwave Irradiation in Wide Reaction Conditions

  • Jun, Jong-Won;Lee, Ji-Sun;Seok, Hwi-Young;Chang, Jong-San;Hwang, Jin-Soo;Jhung, Sung-Hwa
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1957-1964
    • /
    • 2011
  • Various reaction conditions uding temperature, time and type and concentration of templates have been changed in order to facilely synthesize, especially with microwave (MW) heating, SAPO-34 molecular sieves. SAPO-34 molecular sieve can be synthesized rapidly with microwave irradiation from a gel containing tetraethylammonium hydroxide (TEAOH) as a template. However, other several templating molecules lead to SAPO-5 molecular sieve under microwave irradiation even though SAPO-34 is obtained by conventional electric synthesis from the same reactant gels. Moreover, SAPO-34 can be obtained more easily by increasing the TEAOH or silica concentration or by increasing the reaction temperature. SAPO-34 can be obtained within 5 min in a selected condition (high temperature of 210 $^{\circ}C$) with microwave heating, which may lead to a continuous production of the important material. SAPO-34 synthesized by microwave irradiation is homogeneous and small in size and shows acidity and a stable performance in the dehydration of methanol and 2-butanol to olefins, suggesting potential applications in acid catalysis.

Hierarchical 5A Zeolite-Containing Carbon Molecular Sieve Membranes for O2/N2 Separation (산소/질소 분리를 위한 다층구조 제올라이트 5A를 함유한 탄소분자체 분리막 제조)

  • Li, Wen;Chuah, Chong Yang;Bae, Tae-Hyun
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.260-268
    • /
    • 2020
  • Mixed-matrix carbon molecular sieve membranes containing conventional and hierarchically structured 5A were synthesized for application in oxygen (O2)/nitrogen (N2) separation. In general, incorporating 5A fillers into porous carbon matrices dramatically increased the permeability of the membrane with a marginal decrease in selectivity, resulting in very attractive O2/N2 separation performances. Hierarchical zeolite 5A, which contains both microporous and mesoporous domains, improved the separation performance further, indicating that the mesopores in the zeolite can serve as an additional path for rapid gas diffusion without sacrificing O2/N2 selectivity substantially. This facile strategy successfully and cost-effectively pushed the performance close to the Robeson upper bound. It produced high performance membranes based on Matrimid® 5218 polyimide and zeolite 5A, which are inexpensive commercial products.

A New Gas-Chromatograghic Method of Organic Elemental Analysis (가스크로마토그래피에 依한 微量元素分析)

  • Kim, You-Sun;Son, Youn-Soo;Choi, Q.Won
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.4
    • /
    • pp.188-191
    • /
    • 1964
  • A new gas-chromatographic method for determining carbon and hydrogen in organic compounds has been developed. After sample combustion was performed in a regular analytical combustion tube with an internal oxidant (a mixture of silver oxide and manganese dioxide) under a helium flow, the water produced was converted to acetylene by passing through a calcium carbide tube. The carbon dioxide and acetylene were trapped by a molecular sieve 5A column at room temperature. The trapped gases were released under programmed temperature raise up to $340^{\circ}C$ and the released gases were passed through a silica gel column. The adsorption of $CO_2$ and $C_2H_2$ in the molecular sieve 5A trapping column were found to be quantitative and the silica gel column showed an excellent resolution of $CO_2$ and $C_2H_2$ for analytical purpose. The analytical results for various known compounds based on the out-put of the thermal conductivity cell calibrated for the amounts of carbon and hydrogen contents in benzoic acid, showed average errors ${\pm}0.5%$ and ${\pm}0.33%$ for carbon and hydrogen, respectively.

  • PDF

Separation of Freon-12 and Air Mixture by Adsorption Process (흡착공정을 이용한 프레온-12와 공기혼합가스의 분리)

  • 강석호;이태진;안희관;김윤갑
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to separate the Freon-12 and air mixture$(CF_2Cl_2/Air=0.1/99.9 vol.%)$ by pressure swing adsorption (PSA), the breakthrough curve was experimentally observed in a fixed bed adsorption column. A single adsorber was packed with various adsorbents such as, the activated carbon(S-AC, W-AC) and the molecular sieve(MS-5A, MS-13X). The order of appearance of breakthrough curve is MS-5A > MS-13X > W-AC > S-AC. The activated carbon was found to be more effective adsorbent for separating Freon-12 from the mixture than the molecular sieve was. From the experimental data obtained by the separation of Freon-12 gas out of the air stream in the steady-state PSA process cycle, whose size is the same one of column used for the breakthrough curve observation, it has been confirmed that Freon-rich gas could be obtained from the purge step of PSA and Freon-free air could be obtained from the adsorption step of PSA cycle.

  • PDF

Study on Carbon Dioxide Control by Using Dry Sorbent in Fludized Bed (유동층에서 dry sorbent를 이용한 CO2 제어에 관한 연구)

  • Lee, Sang-Sup;Kim, Min-Choul;Yoo, Jeong-Seok;Moon, Gil-Ho;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.9 no.4
    • /
    • pp.179-187
    • /
    • 2003
  • The technology of fluidized bed to use dry sorbent can be new technology that reduce the operating cost and make efficient operation. Therefore, this study investigated $CO_2$ control by dry sorbents with operating variables in a fluidized bed, compared with fixed bed for $CO_2$ adsorption capacity and pressure drop, and presented the $CO_2$ adsorption capacity of activated carbon, molecular sieve 5A, molecular sieve 13X, and activated alumina. As the results of this study, the basic data could be achieved for operation of fluidized bed process, and fluidized bed process presented relatively high $CO_2$ adsorption capacity and low pressure drop with the increase of gas velocity. In addition, molecular sieve 5A showed 1.1~3.0-fold later breakthrough point and 1.1~2.7-fold higher adsorption capacity than the other dry sorbents.

  • PDF

Fixed Bed Study for a Detritiation Adsorber

  • Kim K. R.;Lee M. S.;Paek S.;Yim S. P,;Ahn D. H.;Chung H.;Shim M. H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.119-125
    • /
    • 2005
  • A method of predicting the tritium concentration in the air leaving an atmospheric detritiation dryer was modeled for designing a fixed bed dryer and preparing an advanced dryer control. In order to quantify the bed utilization and the dynamic capacity against an inlet humidity and a flow rate, a series of quantitative tests based on the break-through behavior were carried out in an isothermal fixed bed of synthetic zeolites such type as molecular sieve 4A, 5A, 13X and mordenite. The amount of water vapor breaking during the adsorption was estimated to give a breakthrough capacity at the various inlet flow rates and humidity conditions. The molecular sieve 13X exhibited a better adsorption performance at a given bed height.

  • PDF

Synthesis of Functional Lipid from Glyceryl Monooleate and Conjugated Linoleic Acid by Enzymatic Reaction (Glyceryl Monooleate와 Conjugated Linoleic Acid로부터 효소적 반응을 이용한 기능성 유지 합성)

  • Jeon, Mi-Sun;Lee, Ki-Teak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.8
    • /
    • pp.1062-1068
    • /
    • 2009
  • Diacylglycerol (DAG) were synthesized by enzymatic esterification of glyceryl monooleate (GMO) and conjugated linoleic acid (CLA) in a shaking water bath. The reaction was catalyzed by Lipozyme TLIM (immobilized lipase from Thermomyces lanuginosa). Effects of reaction time, molar ratio, enzyme road and molecular sieves were studied. Results of normal-phase high performance liquid chromatography (NP-HPLC) analysis were performed. At 1:1, 2:1 and 3:1 (GMO : CLA) molar ratio and Lipozyme TLIM of 20% amount, DAG were produced in 42.6, 54.4 and 54.6 area% in 1 hr, respectively. When different Lipozyme TLIM amounts (2, 5, 10, 20%) were used with 2:1 (GMO : CLA) molar ratio, DAG were produced 21.4 (24 hr), 51.7 (12 hr), 56.2 (6 hr) and 54.4 (1 hr) area%, respectively. The reaction in the absence of molecular sieves increased DAG contents. The maximum DAG concentration conditions were obtained with molar ratio of 2:1 (GMO : CLA), lipase concentration of 10% (of substrate), 10% molecular sieves and reaction time of 6 hours at 55$^{\circ}C$. Under this reaction condition, produced DAG-rich oil was composed of 69 area% DAG, 7.9 area% TAG, 2 area% FFA, and 21.1 area% MAG.

Estimation of Internal Motion for Quantitative Improvement of Lung Tumor in Small Animal (소동물 폐종양의 정량적 개선을 위한 내부 움직임 평가)

  • Yu, Jung-Woo;Woo, Sang-Keun;Lee, Yong-Jin;Kim, Kyeong-Min;Kim, Jin-Su;Lee, Kyo-Chul;Park, Sang-Jun;Yu, Ran-Ji;Kang, Joo-Hyun;Ji, Young-Hoon;Chung, Yong-Hyun;Kim, Byung-Il;Lim, Sang-Moo
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • The purpose of this study was to estimate internal motion using molecular sieve for quantitative improvement of lung tumor and to localize lung tumor in the small animal PET image by evaluated data. Internal motion has been demonstrated in small animal lung region by molecular sieve contained radioactive substance. Molecular sieve for internal lung motion target was contained approximately 37 kBq Cu-64. The small animal PET images were obtained from Siemens Inveon scanner using external trigger system (BioVet). SD-Rat PET images were obtained at 60 min post injection of FDG 37 MBq/0.2 mL via tail vein for 20 min. Each line of response in the list-mode data was converted to sinogram gated frames (2~16 bin) by trigger signal obtained from BioVet. The sinogram data was reconstructed using OSEM 2D with 4 iterations. PET images were evaluated with count, SNR, FWHM from ROI drawn in the target region for quantitative tumor analysis. The size of molecular sieve motion target was $1.59{\times}2.50mm$. The reference motion target FWHM of vertical and horizontal was 2.91 mm and 1.43 mm, respectively. The vertical FWHM of static, 4 bin and 8 bin was 3.90 mm, 3.74 mm, and 3.16 mm, respectively. The horizontal FWHM of static, 4 bin and 8 bin was 2.21 mm, 2.06 mm, and 1.60 mm, respectively. Count of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.10, 4.83, 5.59, 5.38, and 5.31, respectively. The SNR of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.18, 4.05, 4.22, 3.89, and 3.58, respectively. The FWHM were improved in accordance with gate number increase. The count and SNR were not proportionately improve with gate number, but shown the highest value in specific bin number. We measured the optimal gate number what minimize the SNR loss and gain improved count when imaging lung tumor in small animal. The internal motion estimation provide localized tumor image and will be a useful method for organ motion prediction modeling without external motion monitoring system.

Finite Element Analysis on the Strength Safety of a Fuel Tank for Highly Compressed Gas Vehicle (수술실 내의 아산화질소($N_2O$) 노출평가)

  • Baek, Jong-Bae;Uhm, Min-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.34-38
    • /
    • 2009
  • Nitrous oxide, which is used as an anesthetic gas, has been shown to be a chronic health hazard. It is necessary to monitor and control the nitrous oxide exposure of the operating theaters staff. In this study, N2O exposure level of the operating nurses is assessed with a GC-ECD. The nitrous oxide gas is collected on a molecular sieve 5A contained in a glass tube and desorbed for 12 hours at $100^{\circ}C$ in heating block. As a result of the test using GC-ECD, calibration curve's $R^2$ of $N_2O$ is 0.9992, LOD is $0.96{\mu}g$/injection, LOQ is $3.21{\mu}g$/injection, desorption efficiency is 94.78 4.50% in average and break through is within 10% compared with the concentration. The average concentration before operation is 5.12ppm and it is 42.3ppm during operation. There are a significant difference showing that the P value is lower than 0.05. Assessing exposure level to nitrous oxide based on nurses' working positions, the exposure levels do not show significant difference( P>0.005). And $N_2O$ in active sampling method is higher than passive sampling method(P<0.05).

  • PDF