• Title/Summary/Keyword: molecular magnet

Search Result 21, Processing Time 0.027 seconds

The design and fabricationt for ion fraction measurement of plasma generator (플라즈마발생기의 이온분율 측정 장치 설계 및 제작)

  • Lee, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

THE EFFECT OF STATIC MAGNETIC FIELDS ON MOLECULAR AND CELLULAR ACTIVITIES (정자기장이 효소와 세포 활성에 미치는 영향)

  • Park, Jae-Gu;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.929-941
    • /
    • 1997
  • Optimal force for orthodontic treatment is the force that produces a rapid rate of tooth movement without discomfort to the Patient or ensuing tissue damage. Recently considerable interest has been generated in the application of magnets as a way to obtain an optimal force. The purpose of the present study was to investigate the effect of static magnetic fields of Sm-Co magnets on molecular and cellular activities. The distance of erythrocyte sedimentation was measured directly, and the activities and the syntheses of $Fe^{2+}$-related enzymes (catalase and NO synthase) and non $Fe^{2+}$-related enzyme (lactic dehydrogenase) were assayed by the spectrophotometer. The growth and the proliferation of osteoblast-like cells $MC_3T_3-E_1$ were determined by the crystal violet staining and the ${^3}H$-thymidine incorporation. The erythrocytes were exposed to the pole face flux density of 1,400 G (gauss), and the enzymes and osteoblast-like cells $MC_{3}T_3-E_1$ were exposed to the flux density of 7,000 G. The results obtained were as follows: 1. The distance of sedimentation of erythrocyte was not affected by the static magnetic fields. 2. The activities of catalase and lactic dehydrogenase were not affected by the static magnetic fields. 3. The intracellular syntheses of NO synthase and lactic dehydrogenase were not affected by the static magnetic fields. 4. The growth and the proliferation of cultured osteoblast-like cells $MC_{3}T_3-E_1$ were not affected by the static magnetic fields. These results suggested that the molecular and cellular activities were not significantly influenced by the static magnetic fields.

  • PDF

Development of UBMS(Unbalanced Magnetron Sputtering) System and Ion Current Density Measurement of Copper Target (UBM 마그네트론 스퍼터 시스템을 이용한 구리 타겟의 이온전류밀도 향상 연구)

  • Kang, Chunghyeon;Joo, Junghoon
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.3
    • /
    • pp.192-197
    • /
    • 2017
  • A 6-way-cross consisting of a 2.75-inch CF flange was used as a main chamber on a PFEIFFER VACUUM TMP station based on a 67 l / sec turbo molecular pump and a diaphragm pump to produce a magnet array with a volume ratio of 5.5: 1.A 1-inch diameter copper target and graphite target were fabricated using MDX-1.5K from Advanced Energy Industries, Inc as a DC power supply. Ion current density of copper target and graphite target was measured by unbalanced magnetron sputtering. The basic pressure condition was $6.3{\times}10^{-7}mbar$ and the process pressure was Ar 50 sccm at $1.0{\times}10^{-2}mbar$ (7.5 mTorr) in the Ar atmosphere. Therefore, the relative density of copper ions reaching the substrate with the measured ion current density was derived.

Electronic Structure Calculations of Cubane-type Cu4 Magnetic Molecule (Cubane 구조를 가진 Cu4 분자자성체의 전자구조 계산)

  • Park, Key Taeck
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.119-123
    • /
    • 2016
  • We have studied electronic and magnetic structure of cubane-type Cu magnetic molecule using density functional method. The calculated density of states show that Cu has 3d $x^2-y^2$ hole orbital because of short distances between Cu atom and in-plane 4 ligand atoms. The calculated total energy with in-plane antiferromagnetic spin configuration is lower than those of ferromagnetic configurations. The calculated exchange interaction J between in-plane Cu atoms is much larger than those between out-plane Cu atoms, since the $x^2-y^2$ hole orbital ordering of Cu 3d orbitals induces strong super-exchange interaction between in-plane Cu atoms.

Species Diversity and Seasonal Distribution of Culicoides spp. (Diptera: Ceratopogonidae) in Jeju-do, Republic of Korea

  • Kim, Heung Chul;Bellis, Glenn A.;Kim, Myung-Soon;Klein, Terry A.;Gopurenko, David;Cai, Du-Cheng;Seo, Hyun-Ji;Cho, In-Soo;Park, Jee-Yong
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.4
    • /
    • pp.501-506
    • /
    • 2015
  • Biting midges belonging to the genus Culicoides (Diptera: Ceratopogonidae) were collected by Mosquito $Magnet^{(R)}$ and black light traps at 5 sites on Jeju-do, Republic of Korea (Korea), from May-November 2013 to determine species diversity and seasonal distribution. A total of 4,267 specimens were collected, of which 99.9% were female. The most common species was Culicoides tainanus (91.8%), followed by C. lungchiensis (7.2%) and C. punctatus (0.6%), while the remaining 4 species accounted for <0.5% of all Culicoides spp. that were collected. High numbers of C. tainanus were collected in May, followed by decreasing numbers through August, and then increasing numbers through November when surveillance was terminated. Peak numbers of C. lungchiensis were collected during September, with low numbers collected from May-August and October-November. The presence of C. lungchiensis in Korea was confirmed by morphological and molecular analyses.

Electronic and Magnetic Structure Calculations of Cubane-type Co4 Magnetic Molecule (Cubane 구조를 가진 Co4 분자자성체의 전자구조 및 자기구조계산)

  • Park, Key Taeck
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.4
    • /
    • pp.140-144
    • /
    • 2017
  • We have studied electronic and magnetic structure of cubane-type Co magnetic molecule using density functional method. The calculated density of states show $Co^{+2}$ ionic state and high-spin state because of large exchange interaction between inside Co 3d electrons. The exchange interaction J between Co atoms depends Co-O-Co angle. The calculated J is ferromagnetic with right angles. On the other hand J is antiferromagnetic with large angles since super-exchange interactions between $Co^{+2}$ atoms. It induces that Co cubane has a antiferromagnetic spin structure of AFM1 = [${\uparrow}{\uparrow}{\downarrow}{\downarrow}$]

Electronic and Magnetic Structure Calculations of Cubane-type Mn4 Cluster (Cubane-type Mn4 클러스터의 전자구조 및 자기구조 계산)

  • Park, Key-Taeck
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.121-124
    • /
    • 2012
  • We have studied electronic and magnetic structure of cubane-type Mn4 cluster using OpenMX method based on density functional method. The calculated density of states shows that the octahedron of O atoms split $e_g$ and $t_{2g}$ energy levels like bulk MnO with cubic structure. Total energy with antiferromagnetic spin configuration is lower than those of other spin configurations because of super exchange interaction. Calculated exchange interaction J between Mn atoms with anti-parallel spin is larger than between Mn atoms with parallel spin.

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

Electronic and Magnetic Structure Calculations of Diiron Enzymes (이중 철 효소의 전자구조 및 자기구조 계산)

  • Park, Key Taeck
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.106-110
    • /
    • 2015
  • We have studied electronic and magnetic structure of 2 kinds of diiron molecules using OpenMX method based on density functional method. The calculated density of states of diiron-2 is similar with that of diiron-4 because of equal number of 6 ligand atoms. The calculated total energy with antiferromagnetic spin configuration is lower than those of ferromagnetic configurations for both of them. The exchange interaction J of diiiron-4 between $Fe^{+3}$ atoms is one order larger than that of diiron-2, and the calculated J matches well with the experimental one. That comes from the short distance of Fe-O and the high O 2p energy levels. It derives a strong super exchange interaction. The angle of diiron-4 between Fe atoms is bigger than that of diiron-2. It also derives a strong super exchange interaction because of the ${\sigma}$-bond between Fe and O atoms.

Effect of the magnetism(neodymium magnet) on growth factor receptors of osteoblasts (희토류 자석의 자성이 골모세포 성장인자 수용체의 증가에 미치는 영향에 관한 연구)

  • Lee, Sang-Min;Lee, Sung-Bok;Choi, Boo-Byung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.87-96
    • /
    • 2003
  • The purposes of this study were to find out the optimum intensity of magnetic field where magnetism could promote the activity of osteoblast, and to discover the possibility of clinical application in the areas of dental implants and bone grafts by confirming the effect of clinically increasing bone formation. In this experiment, we used the Neodymium magnet, which had magnetic power six times as strong as the current ones and enabled the resistances against the demagnetization up to 20 to 50 times to be minimized with the size of 1mm in sight. In order to culture cells, a specially designed device was used. It was made to adjust the distance and accordingly to control the intensity of the magnetic field, by placing the cell culture plate in the center with a magnet of 1mm long and thick installed on the both ends. Using MC3T3-E1 cell, a kind of osteoblast-like cell, we cultured, for 24 hours, not only the test group which had been cultured under the magnetic fields with different intensity of 5, 10, 50, 100, 500, and 1000 Gauss, but also the control group excluding the influences of the magnetic field. After observing the cell's form and the density of the culture medium through an inverted microscope, we made a series of proceedings needed for the immunofluoroscence staining, such as fixation, normal serum reaction, primary antibody reaction, and secondary antibody reaction. And with a fluorescence microscope, we observed those-above and compared the frequency of expression of IFG-1 receptor. To make a Western immunoblotting analysis, the cells cultured under the same condition as the above had the procedure of the lysis buffer and the acrylamide gel electrophoresis was carried out. Protein transferred into the nitrocellulose membrane and tested on the primary and the secondary antibody reactions was observed and compared. The results were as follows: When observed through an inverted microscope, the nuclear divisions of the cells under the magnetic field of 10 Gauss were the most active, and the density of the cells could be observed the most enormously. As the result of an immunofluoroscence staining of IGF-1 receptor, the expression of IFG-1 was the most frequently observed under the magnetic field of 10 Gauss. On the other hand, few differences of consideration were made between the test group cultured under the magnetic fields of 5, 500, and 1000 Gauss and the control group. In respect of the expression of IFG-1 receptor, the test group cultured under the magnetic fields of 50 and 100 Gauss were higher than the control group, and lower than that cultured under the magnetic field of 10 Gauss.(p<0.05) According to the Western immunoblotting analysis, the band of IFG-1 receptor which had 85KDa of molecular weight was the darkest. Judging from the above-mentioned results, the growth factor receptor of an osteoblast cell which was an important criterion for the bone formation was increased in maximum under the magnetic field of 10 Gauss. Moreover it was observed that the optimum intensity of magnetic field in which magnetism made the activity of the osteoblast cell increase was about 10 Gauss.