Casting Layout Design Using CAE Simulation : Automotive Part(Oil Pan_BR2E) (CAE을 이용한 주조방안설계 : 자동차용 부품(오일팬_BR2E))

  • Kwon, Hong-kyu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.1
    • /
    • pp.35-40
    • /
    • 2017
  • A most important progress in civilization was the introduction of mass production. One of main methods for mass production is die-casting molds. Due to the high velocity of the liquid metal, aluminum die-casting is so complex where flow momentum is critical matter in the mold filling process. Actually in complex parts, it is almost impossible to calculate the exact mold filling performance with using experimental knowledge. To manufacture the lightweight automobile bodies, aluminum die-castings play a definitive role in the automotive part industry. Due to this condition in the design procedure, the simulation is becoming more important. Simulation can make a casting system optimal and also elevate the casting quality with less experiment. The most advantage of using simulation programs is the time and cost saving of the casting layout design. For a die casting mold, generally, the casting layout design should be considered based on the relation among injection system, casting condition, gate system, and cooling system. Also, the extent or the location of product defects was differentiated according to the various relations of the above conditions. In this research, in order to optimize the casting layout design of an automotive Oil Pan_BR2E, Computer Aided Engineering (CAE) simulation was performed with three layout designs by using the simulation software (AnyCasting). The simulation results were analyzed and compared carefully in order to apply them into the production die-casting mold. During the filling process with three models, internal porosities caused by air entrapments were predicted and also compared with the modification of the gate system and overflows. With the solidification analysis, internal porosities occurring during the solidification process were predicted and also compared with the modified gate system.

Investigation of the Filling Unbalance and Dimensional Variations in Multi-Cavity Injection Molded Parts (다수 캐비티의 사출성형품에서 충전의 불균형과 성형품 치수 편차의 교찰)

  • Kang, Min-A;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.501-508
    • /
    • 2008
  • Small injection molded articles such as lens and mobile product parts are usually molded in multi-cavity mold. The problem occurring in multi-cavity molding is flow unbalance among the cavities. The flow unbalance affects the dimensions and physical properties of molded articles. First of all, the origin of flow unbalance is geometrical unbalance of the delivery system. However, even the geometry of the delivery system is well balanced, cavity unbalance occurs. This comes from the temperature distributions in the cross-section of runner. Temperature distribution depends upon injection speed because heat generation near runner wall is high at high injection speed. Among the operational conditions, injection speed is the most significant process variable affecting the filling unbalances in multi-cavity injection molding. In this study, experimental study of flow unbalance has been conducted for various injection speeds and materials. Also, the filling unbalances were compared with CAE results. The dimensions and weights of multi-cavity molded parts were examined. The results showed that the filling unbalances vary according to the injection speeds and resins. Subsequently, the unbalanced filling and pressure distribution in the multi-cavity affect the dimensions and physical states of molded parts.

A Study on the Molding Analysis of IC Package in Transfer mold (트랜스퍼 금형에 있어서 IC 폐키지의 성형 유동 해석에 관한 연구)

  • 구본권
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.64-67
    • /
    • 1995
  • Transfer Molding is currently the most widely used process for encapsulation integrated circuits(;IC). Although the process has been introduced over 20 years ago, generating billions of parts each year, it is far from being optimized. With each new mold, epoxy mold, epoxy mold compound, and lead-frame, lengthy period and expensive qualification runs have to be performed to minimized defects ranging from wire sweep, incomplete fill, and internal voids etc. This studies describes how simulation can be applied to transfer molding to yield acceptable design and processing parameter. The non-isothermal filling of non-newtonian reactive epoxy molding compound(;EMC) in a multi-cavity mold is analyzed. Sensitivity analysis is conducted to investigate the influence of process deviations on the final molded profile. This study trend is carried out by following some heuristic process guidelines.

  • PDF

Development of a new injection mold structure for internal gears (새로운 내측기어 성형용 사출성형 금형구조의 개발)

  • Kwon, Youn-Suk;Je, Deok-Keun;Jeong, Yeong-Deug
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.129-133
    • /
    • 2008
  • As a rotating machine element, plastic gears are more and more widely used in such as industrial machine element, since plastic gear is lighter, higher wear-resistance, and higher vibration absorbing ability than metal gears. When operating plastic parts, tooth breakage and fatigue life shortened due to increasing number of applying load and tooth flank temperature rising, such that accuracy of plastic gears is divided from allowable range to cause vibration and noise. On this study, a internal plastic gears are developed which improved the filling balance molding process by a new injection mold structure. The new mold structure called HR3P(hot runner type 3plate mold). As the result from this studies, we obtained a very accurate roundness internal gears by using design of experiment.

  • PDF

Numerical analysis of injection molding for filling efficiency on ultrasonic process

  • Lee, Jae-Yeol;Kim, Nak-Soo;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.2
    • /
    • pp.79-88
    • /
    • 2008
  • In this study, we focus on the improvement of the filling efficiency in injection molding by application of ultrasonic vibration. While studies about the filling efficiency of typical filling processes in the injection molding have been widely performed, there have been only few studies about the filling efficiency of an ultrasonic process. The effect of the ultrasonic vibration is an important process condition, which influences the flow characteristics of polymer melt. This new condition even affects well-known injection conditions such as cavity pressure, injection temperature and mold temperature. For this study, we carried out a numerical analysis by appropriate modeling and analysis of the ultrasonic process in the filling process. To verify this numerical analysis, we compared the numerical results with the experimental data. Also, we analyzed the filling process in a thin cavity using this numerical analysis. To understand the flow characteristics of polymer melt in the ultrasonic process, we substituted real and complex vibration conditions with simplified and classified conditions according to the position of vibrating cavity surfaces and the phase difference between two opposing cavity surfaces. We also introduced MFR (melt flow ratio) as a new index to estimate the filling efficiency in the ultrasonic process.

Injection Mold Technology of Protein Chip for Point-of-Care (현장진단용 단백질 칩 사출금형기술)

  • Lee, Sung-Hee;Ko, Young-Bae;Lee, Jong-Won;Jung, Hae-Chul;Park, Jae-Hyun;Lee, Ok-Sung
    • Design & Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.74-78
    • /
    • 2012
  • A multi-cavity injection mold system of protein chip for point-of-care with cavity temperature and pressure sensors was proposed in this work. In advance of manufacturing for the multi-cavity injection mold system, a single cavity injection mold system to mold protein chip was considered. Injection molding analysis for the presented system was performed to optimize the process of the molding and suggest guides to design. On the basis of the results for the single cavity system, a multi-cavity injection mold system for protein chip was analyzed, designed and manufactured with cavity temperature and pressure sensors. Results of balanced filling for protein chip models were obtained from the presented mold system.

  • PDF

Development of Rapid Cooling System for Injection Mold (사출금형의 급속냉각시스템 개발)

  • Moon, Young-Bae;Choi, Youn-Sik;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.31-34
    • /
    • 2014
  • The Injection molding is used more than 70% of total production in plastic products. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The cooling system and time affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. In this study, the rapid cooling system was developed and performed a efficiency test. This system could refrigerate coolant to $1^{\circ}C$ and had to need 10 minutes for normal operating. However, if response time of temperature controller and sensor will be increased, the performance of this system will increase.

  • PDF

Prediction of Core Shift using Injection Molding CAE program (사출성형 CAE 프로그램을 이용한 코어 휨의 예측)

  • Moon, Jeong-Yeon;Kwak, Min-Hyuk;Park, Tae-Won;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.7-11
    • /
    • 2014
  • The Core-Shift is often generated on injection mold which have thin and long core. And Core-Shift brings out problems for thickness variation and product ejecting process. In this study, analysis of Core-Shift was performed according to change of materials of core(steel P-20, Be-Cu) and various polymers(PP, PC) by using MoldFolw MPI 6.1 which is commercial injection molding analysis program. As the results of analysis, the magnitude of Core-Shift was increased as being use polymer had lower fluidity and lower rigidity core. In the future, we will study the relationship between amount of Core-Shift and ejecting force.

  • PDF

A study on coupling effect during lifting (다수 캐비티 사출금형에서 충전 불균형 원인 분석 및 스크류 런너 디자인)

  • Kang, Min-A;Kim, Hae-Yeon;Lyu, Min-Young
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.155-158
    • /
    • 2008
  • Flow imbalance among the cavities was often observed in multi-cavity mold. The flow imbalance affects on the dimensions and physical properties of molded articles. First of all, the origin of flow imbalance is geometrical imbalance of delivery system. However, even the geometry of delivery system is balanced the cavity imbalance is being developed. This comes from the temperature distribution in the cross-section of runner, which is affected by the operational conditions. In this study, experimental study of flow imbalance has been conducted for various injection speeds. This study also suggests new runner design to eliminate flow imbalance in multi-cavity injection mold. Simulation and experimental results showed suggested new designed runner could eliminate or reduce flow imbalance in multi-cavity injection mold.

  • PDF

Study on the Fabrication of Mg Alloy Sheet by a Semi-Solid Forming Process (반고상 성형법에 의한 Mg 합금 박판재의 제조에 관한 연구)

  • Kim, Jeong-Min;Park, Bong-Koo;Kim, Ki-Tae;Jung, Woon-Jae
    • Journal of Korea Foundry Society
    • /
    • v.22 no.5
    • /
    • pp.245-251
    • /
    • 2002
  • Cast AZ91 and extruded AM50 alloys were isothermally heated as solid/liquid coexistent temperatures, and semi-solid formed into sheets. Mold filling ability of semi-solid slurry with different liquid fractions was investigated in relation to process variables such as injection speed and mold temperature. Relatively uniform distribution of solid particle size and liquid fraction were observed throughout the semi-solid formed sheet. AZ91 alloy sheets were also manufactured by conventional die casting and compared with the semi-solid formed. It was found that the surface was more smooth and the dimensional accuracy was higher in case of the semi-solid formed.