• 제목/요약/키워드: moisture conditioning

검색결과 105건 처리시간 0.023초

대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구 (Numerical study for performance analysis and design of a counterflow type cooling tower)

  • 이상윤;이정희;최영기;유홍선
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

공조기가 설치된 고분 내에서의 열 및 음 환경 평가 (Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System)

  • 박진양;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

Numerical Study for the Performance Analysis and Design of a Crossflow- Type Forced Draft Cooling Tower

  • Choi, Young-Ki;Kim, Byung-Jo;Lee, Sang-Yun;Lee, Jung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.1-13
    • /
    • 2000
  • A numerical study for performance analysis of a crossflow-type forced draft cooling tower has been performed based on the finite volume method with non-orthogonal body fitted, and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy, moisture fraction, water enthalpy, and water mass balance equations are solved with Navier-Stoke's equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study. The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also performed.

  • PDF

자재 시공면의 온습도 측정을 위한 간이 온.습도 측정지의 성능 연구 (A Study on Performance of Thermo-Humidity Indicator Card for Measuring Thermo-Humidity of Work Surface)

  • 허정용;최창호;이윤규
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.236-242
    • /
    • 2009
  • In finishing work, defects are often taken place by many factors. One of them is the thermo-humidity condition on the work surface as coating and anointing adhesives. Thus, the condition of thermo-humidity on work surface should be checked prior to the finishing work. However, many construction companies show a tendency to overlook it because not only are measurement tools so expensive but they don't have skilled hands about those tools. Therefore, we propose the measurement method that makes it easy to recognize surface thermo-humidity condition so as to reduce constructional flaws. And then we test this product. The test progresses to four stages with various conditions. We evaluate its usefulness and application possibility of this product in the field.

곡류 및 버섯류의 평형함수율 및 박층건조방정식에 관한 연구(I) -벼의 박층건조방정식 - (Equilibrium Moisture Contents and Thin Layer Drying Equations of Cereal Grains and Mushrooms (I) - Thin Layer Drying Equations of Short Grain Rough Rice -)

  • 금동혁;박춘우
    • Journal of Biosystems Engineering
    • /
    • 제22권1호
    • /
    • pp.11-20
    • /
    • 1997
  • Thin layer drying tests of short gain rough rice were conducted in an experimental dryer equiped with air conditioning unit. The drying tests were performed in triplicate at three air temperatures of $35^circ$, $45^circ$, $55^circ$, and three relative humidities of 40%, 55%, 70%, respectively. Previously published thin layer equations were reviewed and four different models widely used as thin layer drying equations for cereal grains were selected. The selected four models were Pages, simplified diffusion, Lewis's and Thompson's models. Experimental data were fitted to these equations using stepwise multiple regression analysis. The experimental constants involved in tow equations were represented as a function of temperature and relative humidity of drying air. The results of comparing coefficients of determination and root mean square errors of miosture ratio for low equations showed that Page's and Thompsons models were found to fit adequately to all drying test data with coefficient of determination of 0.99 or better and root mean square error of moisture ratio of 0.025.

  • PDF

능이버섯의 건조 방정식 (Drying Equations of Sarcodon Aspratus)

  • 금동혁;노정근;정태영;홍성렬;박기문;김훈;한재웅
    • Journal of Biosystems Engineering
    • /
    • 제29권1호
    • /
    • pp.59-64
    • /
    • 2004
  • This study was performed to determine drying equations of sarcodon aspratus. Drying tests for sarcodon aspratus were conducted in an experimental dryer equiped with an air conditioning unit. The drying tests were performed at three air temperatures of 30$^{\circ}C$, 40$^{\circ}C$ and 50$^{\circ}C$, and two relative humidities of 30% and 50%. Measured moisture ratio data were fitted with the selected four drying models(Page, Thompson, Lewis and simplified diffusion models) using stepwise multiple regression analysis. When the coefficients of determination and root mean square errors of moisture ratio were evaluated for four drying models, the Page model was found to fit adequately to all the drying test data with coefficient of determination of 0.9996 and RMSE of 0.00523.

집성재 라미나용 낙엽송 재내 잔류 건조응력 변화 분석 (Analysis of residual drying stress in Larix Kaempferi wood used as glulam laminar)

  • 한연중;장윤성;박용건;정기영;홍정표;이전제;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.535-543
    • /
    • 2013
  • 본 연구에서 국산 낙엽송재의 공학목재로의 이용가능성, 특히 교호집성재 라미나로서의 이용가능성을 확인하기 위하여 열기건조 중과 건조 후 판재 내 잔류응력을 분석하였다. 연구결과를 통해 이쿼라이징 처리에 의한 함수율 동일화 효과가 증명되었고, 컨디셔닝 처리에 의한 잔류응력의 감소효과가 정량화되었다. 건조 중 목재 내 잔류응력 분석을 위하여 프롱법과 슬라이스법을 실시하였다. 프롱 제작 후 표면경화율을 측정하였고, 슬라이스의 절단 후 탄성변형량을 기준으로 표면으로부터 약 10 mm 깊이까지의 건조응력을 정량적으로 분석하였다. T10-C4와 T12-D5 열기건조 스케줄 적용 시 열기건조 중 판재 표면의 인장응력과 압축응력은 모두 2.2 MPa을 넘지 않음을 확인하였다. 낙엽송의 횡단방향 인장강도와 압축강도가 평균 2.65 MPa, 4.60 MPa인 점을 고려하면, 더욱 강한 건조스케줄 적용이 추천된다. 건조 후처리에 의해 폭굽음과 비틀림을 약 40% 줄일 수 있었다.

슬러지의 탈수 특성에 대한 마이크로파와 약품개량의 영향 (Effect of Microwave Irradiation and Chemical Conditioning for Dewatering Characteristics of Sludge)

  • 박상숙;강화영;왕승호
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.732-738
    • /
    • 2005
  • 본 연구는 슬러지의 효율적인 처리를 위하여 슬러지의 탈수 및 건조 효율에 미치는 마이크로파의 영향을 실험하여 마이크로파의 적정 처리 조건을 제시하는데 목적이 있다. 마이크로파를 이용하여 슬러지의 탈수 효율을 향상시키기 위해서는 슬러지 부피에 따른 적정 마이크로파의 조사시간의 결정이 매우 중요하며, 적정 시간 동안 마이크로파 처리된 농축슬러지의 경우 모세흡입시간이 52.3초에서 30.8초로 저감되어 탈수성이 상당히 향상되었고, 마이크로파에 의해 개량된 농축슬러지의 압력여과 후 함수율은 81.4%로 나타났다. 또한 마이크로파와 전기로의 탈수슬러지 건조 특성을 평가한 결과, 슬러지의 함수율을 55% 이하로 건조시키는데 마이크로파 가열 방식은 3분이 소요된 반면, 전기로를 이용하여 $105^{\circ}C$에서 건조한 경우에는 40분이 소요되었고, $170^{\circ}C$에서 건조한 경우는 20분이 소요되었으며, $300^{\circ}C$에서 건조한 경우는 9분이 소요되었다. 따라서 마이크로파를 이용하여 슬러지를 건조할 경우, 기존 가열 방식보다 훨씬 효율적으로 슬러지에서 수분을 제거할 수 있음을 알 수 있었다.

압출성형 공정변수가 압출성형 펠릿의 팽화에 미치는 영향 (Effects of Extrusion Process Parameters on Puffing of Extruded Pellets)

  • 김재현;류기형
    • 한국식품과학회지
    • /
    • 제33권1호
    • /
    • pp.55-59
    • /
    • 2001
  • 쌀의 팽화에 관한 연구는 팝콘에 관한 연구와 비교하면 매우 미흡한 편이다. 쌀을 팽화시킬 때 대부분 가압식 팽화기나 압출성형기를 이용하고 있다. 대부분의 쌀의 팽화에 관한 연구는 인도에서 이루어져 왔으며, 가공조건(수분함량, 가열온도) 등이 팽화쌀의 물리화학적 성질에 관한 연구가 대부분이다. 팝콘과 같은 인스턴트 팽화쌀의 팽화기작 및 개발에 관한 연구는 극히 제한되어 있다. 압출성형 팽화펠릿의 팽화에서 3일 수침 후 분쇄한 찹쌀을 이용하여 수분함량 $20{\sim}27%$, $CO_2$ 가스주입압력 2.8 MPa, 스크류회전속도 200 rpm으로 제조한 펠릿을 microwave oven에서 팽화시 밀도와 조직감이 비교적 낮게 나타나는 경향을 보였다. 또한 압출성형기로 제조된 펠릿의 팽화시 가장 큰 영향인자는 펠릿의 수분함량과 가스주입압력, 스크류회전속도의 조절에 의해 팽화 및 조직감을 최적화 할 수 있었다.

  • PDF

온도.종자수분함량 및 삼투처리가 콩의 발아 및 묘신장에 미치는 영향 (Effects of Temperature, Seed Water Content and Osmoconditioning on Germination and Seedling Elongation of Soybeans)

  • Rak Chun, Seong;Many C., Minor;Eun Hi, Hong
    • 한국작물학회지
    • /
    • 제31권4호
    • /
    • pp.447-453
    • /
    • 1986
  • 콩 품종(williams)의 발아와 묘신장을 두 온도, 세 종자, 수분함양 및 Polyethylene glycol-800(PEG) 처리와 무처리에서 측정하였다. 분할구배치법 사반복으로 실시하였으며 시료를 2시간부터 8일까지 각처리 조합에서 채취하였다. 콩 종자를 0.2% Thiram을 첨가한 30% PEG 여액에 놓아 15$^{\circ}C$에서 6 일간 침청후 증류수로 선정하여 25.5$^{\circ}C$에서 3 일간 건조하여 10개의 처리 또는 무처리 종자를 plastic petri-dish안의 9 cm 여과지에 놓아 수분함양에 정당한 증류수를 첨가하였다. Parafilm으로 밀봉하여 항온무광조건의 처리 온도에서 발아시켰다. 수분함양이 50% 또는 이하인 처리에서는 두 온도 모두 묘신장이 일어나지 않았다. PEG를 이용한 삼투처리는 15$^{\circ}C$에서는 묘수분 흡수와 체신장간에 정의 상관 효과를 보였으나 3$0^{\circ}C$에서는 거의 없었다. 종자 또는 묘수분함량은 발아기간동안 초기에 급속히 증가하여 15$^{\circ}C$에서는 56시간에, 그리고 3$0^{\circ}C$에서는 28시간에 60%에 도달하였다. 묘신장은 종자수분함양이 15$^{\circ}C$에서는 60%에서 시작되었지만 3$0^{\circ}C$에서는 20시간에 시작되었다. 콩묘는 15$^{\circ}C$에 비하여 3$0^{\circ}C$에서 사배 이상 신장되었다. 발아기간 동안의 수분흡수양상은 이 시험에서는 두 단계로 특정되었다.

  • PDF